• 제목/요약/키워드: Current magnitude minimum

검색결과 27건 처리시간 0.023초

Variable-magnitude Voltage Signal Injection for Current Reconstruction in an IPMSM Sensorless Drive with a Single Sensor

  • Im, Jun-Hyuk;Kim, Sang-Il;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1558-1565
    • /
    • 2018
  • Three-phase current is reconstructed from the dc-link current in an AC machine drive with a single current sensor. Switching pattern modification methods, in which the magnitude of the effective voltage vector is secured over its minimum, are investigated to accurately reconstruct the three-phase current. However, the existing methods that modify the switching pattern cause voltage and current distortions that degrade sensorless performance. This paper proposes a variable-magnitude voltage signal injection method based on a high frequency voltage signal injection. The proposed method generates a voltage reference vector that ensures the minimum magnitude of the effective voltage vector by varying the magnitude of the injection signal. This method can realize high quality current reconstruction without switching pattern modification. The proposed method is verified by experiments in a 600W Interior permanent magnet synchronous machine (IPMSM) drive system.

Eliminating the Third Harmonic Effect for Six Phase Permanent Magnet Synchronous Generators in One Phase Open Mode

  • Liu, Jian;Yang, Gui-Jie;Li, Yong;Gao, Hong-Wei;Su, Jian-Yong
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.92-104
    • /
    • 2014
  • To insure stable operation and eliminate twice torque ripple, a topology for a six phase permanent magnet synchronous generator (SP-PMSG) with a neutral point connected together was analyzed in this paper. By adopting an extended transformation matrix, the mathematic model of the space vector control was established. The voltage and torque equations were deduced while considering the third harmonic flux and inductance. In addition, the suppression third harmonic method and the closed loop control strategy were proposed. A comparison analysis indicates that the cooper loss minimum method and the current magnitude minimum method can meet different application requirements. The voltage compensation amount for each of the methods was deduced which also takes into account the third harmonic effect. A simulation and experimental result comparison validates the consistency through theoretical derivation. It can be seen that all of the two control strategies can meet the requirements of post-fault.

계통전압 왜곡 및 불평형시 3상 계통연계인버터의 계통전류제어 기법 (Grid Current Control Scheme at Thee-Phase Grid-Connected Inverter Under Unbalanced and Distorted Grid Voltage Conditions)

  • ;전태원
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1560-1565
    • /
    • 2013
  • This paper proposes the control method for compensating for unbalanced grid current and reducing a total harmonic distortion (THD) of the grid current at the three-phase grid-connected inverter systems under unbalancd and distorted grid voltage conditions. The THD of the grid current caused by grid voltage harmonics is derived by considering the phase delay and magnitude attenuation due to the hardware low-pass filter (LPF). The Cauchy-Schwarz inequality theory is used in order to search more easily for a minimum point of THD. Both the gain and angle of a compensation voltage at the minimum point of THD of the grid current are derived. The negative-sequence components in the three-phase unbalanced grid voltage are cancelled in order to achieve the balanced grid current. The simulation and experimental results show the validity of the proposed control methods.

Control Method for Reducing the THD of Grid Current of Three-Phase Grid-Connected Inverters Under Distorted Grid Voltages

  • Tran, Thanh-Vu;Chun, Tae-Won;Lee, Hong-Hee;Kim, Heung-Geun;Nho, Eui-Cheol
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.712-718
    • /
    • 2013
  • This paper proposes a control method for reducing the total harmonic distortion (THD) of the grid current of three-phase grid-connected inverter systems when the grid voltage is distorted. The THD of the grid current caused by grid voltage harmonics is derived by considering the phase delay and magnitude attenuation due to the hardware low-pass filter (LPF). The Cauchy-Schwarz inequality theory is used in order to search more easily for the minimum point of the THD. Both the gain and angle of the compensation voltage at the minimum point of the THD of the grid current are derived with the variation of cut-off frequencies of the hardware LPF. Simulation and experimental results show the validity of the proposed control methods.

옥내배선 길이에 따른 단락 특성의 실험적 연구 (An Experimental Study on Short Circuit Characteristics by the Interior Wiring Length)

  • 송재용;김진표;조영진;최돈묵;오부열;길경석
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.38-42
    • /
    • 2012
  • This paper describes electrical fire on residential environment such as apartment and detached house caused by defect of interior wiring. We carried out experimental study on short circuit characteristics by the interior wiring length. We were measured arc current, arc energy and interrupting time of earth leakage current circuit breaker(ELB), when an interior wiring break out short circuit in residential environment. From the experiment results, the longer of the interior wiring, the magnitude of arc current decreased and the interrupting time of ELB increased. When applied the A maker's ELB, the strength of arc current and interrupting time of ELB was 254 A and 245 ms respectively at 30 m interior wiring length. In 3 m interior wiring length, arc current and interrupting time was 716 A and 4.24 ms respectively. Arc energy was dependent on the magnitude of arc current and the interrupting time of ELB, the longer the interrupting time, arc energy increasing. In this paper, minimum arc energy was 277 J using C maker's ELB and 3 m interior wiring length(arc current 283 A, interrupting time of breaker 6.28 ms). Therefore in the residential environment, short circuit caused by defect of the interior wiring lead to electrical fire.

상호정보 에너지와 델타함수 기반의 알고리즘에서 크기 조절된 입력의 전력변화에 대한 연구 (A Study on Power Variations of Magnitude Controlled Input of Algorithms based on Cross-Information Potential and Delta Functions)

  • 김남용
    • 인터넷정보학회논문지
    • /
    • 제18권6호
    • /
    • pp.1-6
    • /
    • 2017
  • 이 논문에서는 충격성 잡음환경에서 탁월한 성능을 보이는 CIPD 알고리즘에 대해, 오차에 대한 가우시안 커널로 입력이 보정된 MCI의 전력 추이를 가중치 갱신 방정식에 반영한 새로운 방식을 제안하였다. 제안한 알고리즘이 기존의 CIPD 알고리즘보다 우수한 성능을 가지는지 평가하기 위해, 각 알고리즘의 가중치 벡터 변화량이 얼마나 충격성 잡음에 강인한가를 충격성 잡음하에서 비교하였으며, 실험 결과에서 2배 이상의 정상상태 안정성 향상, 약 1.8배 빠른 수렴속도와 약 2dB 정도 더 낮은 최소 MSE 값을 나타냈다.

Critical current characteristic of various 2G HTS multi-stacked tapes depending on the low external magnetic field

  • Kim, J.;Lee, W.S.;Jin, H.;Ko, T.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권1호
    • /
    • pp.27-31
    • /
    • 2014
  • 2G HTS tapes are widely used for various electric machines. In addition, stacked or parallel connected HTS tapes are essentially used to raise transport current level for large capacity electric machines. Therefore, critical current characteristic of stacked tapes need to be studied. Recently developed 2G HTS tapes are fabricated with various defects doping so that tapes possess pinning center to improve the critical current characteristic. During this process, the critical current is determined minimum value in not perpendicular magnetic field but a specific magnetic field angle according to the reported research. However, the effects of magnetic field angle to critical current of multi-stacked 2G HTS tapes have not been examined. In this paper, field coil which is a race-track coil wound by using an HTS tape with iron-core was fabricated to apply angle adjustable magnetic field to the 2G HTS tape samples. We measured critical current of single and multi-stacked two tapes that have different characteristic depending on various magnetic field angle and magnitude in liquid nitrogen environment. Furthermore, results of single and multi-stacked tapes were compared and analyzed.

스마트 그리드 배전계통에서 인공신경회로망을 이용한 DSP 기반 실시간 고장 판단 방법론 기초 연구 (DSP based Real-Time Fault Determination Methodology using Artificial Neural Network in Smart Grid Distribution System)

  • 김진언;이유림;최정우;노병훈;고윤석
    • 한국전자통신학회논문지
    • /
    • 제18권5호
    • /
    • pp.817-826
    • /
    • 2023
  • 본 논문에서는 스마트 그리드 배전 계통에서 선로상의 고장으로부터 계통을 보호하기 위한 인공 신경 회로망을 기반으로 하는 고장 판단 방법론을 제안하였다. 제안된 방법론에서는 먼저 전류 실효값 크기를 기반으로 일반 고장 여부를 판단하고 다음, 정상 전류로 판단되는 경우 인공 신경 회로망을 기반으로 하는 normal/HIF classifier를 이용하여 고 임피던스 지락 고장 여부를 판단하도록 설계하였다. 반복적인 DSP 모듈 기반 알고리즘 검증 시험들 중에서, 실효 값 크기가 최소 동작전류보다 작은 정상 전류 파형 시험인 경우에 normal/HIF classifier가 전류 파형을 정상상태로 인식하여 부 동작하였으며, 반면에, 저 임피던스 고장의 경우는 고장 상태로 인식하여 정해진 절차에 따라 재폐로 동작을 보임으로써 제안된 방법론의 유효성을 확인할 수 있었다.

회전형 초전도 Power Supply의 설계 및 컴퓨터 시뮬레이션 (The Design and Computer Simulation of the Rotating type of Superconducting Power Supply)

  • 배준한;오윤상;송명곤;지창섭;김호민;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.187-189
    • /
    • 1996
  • In this paper, we have studied several operating characteristics through the analysis of system. First, we have constituted the equivalent circuit to analyze the operating characteristics of rotating type of superconducting power supply and have induced the optimal design parameter. The computer simulation have showed that the pumping current is in proportion to the area of the pole and rotor speed, and is inverse proportion to the magnitude of load. Therefore, to acquire maximum pumping current we must design the power supply system with maximum area of the pole and minimum inductance of the load.

  • PDF

셀 분할을 이용한 거리장의 효율적 계산 (Efficient Calculation of Distance Fields Using Cell Subdivision)

  • 유동진
    • 한국정밀공학회지
    • /
    • 제25권3호
    • /
    • pp.147-156
    • /
    • 2008
  • A new approach based on cone prism intersection method combined with sorting algorithm is proposed for the fast and robust signed distance field computation. In the method, the space bounding the geometric model composed of triangular net is divided into multiple smaller cells. For the efficient calculation of distance fields, valid points among the triangular net which will generate minimum distances with current cell are selected by checking the intersection between current cell and cone prism generated at each point. The method is simple to implement and able to achieve an order of magnitude improvement in the computation time as compared to earlier approaches. Further the method is robust in handling the traditional sign problems. The validity of the suggested method was demonstrated by providing numerous examples including Boolean operation, shape deformation and morphing of complex geometric models.