실증시험용 배전급 초전도 한류기의 특성 평가 및 운전 시험 (Introduction of KEPCO's distribution class SFCL fabricated for verification test)

  • 임성우;박충렬;유승덕;김혜림;현옥배;박권배;심정욱;이경호;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.294_295
    • /
    • 2009
  • Superconducting fault current limiter (SFCL) is an power device of a novel concept. While SFCLs generate no ohmic loss during the operation carrying normal currents, they can limit fault currents very fast making large impedance by their quench characteristics. In 2006, KEPCO has developed a distribution class hybrid type SFCL by a collaborative research project with LS industrial systems. The SFCL has merits in practical and economical points of view. In the SFCL, the superconductor just plays a role of a fault detector and the current limiting is completed by the other current limiting element made of normal metals throu호 the line commutation. As a result, the required amounts of superconductors can be reduced considerably. Consequently, the hybrid SFCL can be fabricated with small size and cost, maintaining perfect current limiting performance. Currently, KEPCO is carrying out a research project at Gochang power test center for the purpose of the verification test of the 22.9 kV/ 630 A class SFCL for the practical application in real grid. Through the project, a long term operational test and fault current test will be done. In this paper, the back ground of development and installation of the SFCL will be explained and the operation plan of the SFCL for the verification test is also introduced.

  • PDF

자속결합형 초전도 한류기의 인가전압별 전류제한 효과 (Current Limiting effects of a Flux-Coupling Type SFCL according to applied voltage)

  • 정병익;최효상;조용선;이주형;정수복;오금곤
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.249-251
    • /
    • 2008
  • We investigated a flux-coupling type superconducting fault current(SFCL) limiter. The SFCL consisted of the primary and secondary coils, which were wound in series each other through an iron core. Superconducting unit was connected with secondary coil in parallel. The flux generated from a coil in normal operation is cancelled out by its structure and the zero resistance of the superconducting unit. In this paper. In order to compare the current limiting effects of the SFCL by applied voltage. When a lied voltage was increased, quench time was shortened Fast quench time is important component under the same fault condition because power burden of the SFCL is reduced by that of the superconducting units. The current limiting behavior of flux-coupling type SFCL was dependent upon the applied voltage.

  • PDF

한계전류밀도 이상에서 전기투석공정의 운전 (Operation of Electrodialysis at Over Limiting Current Density)

  • 박진수;최재환;문승현
    • 멤브레인
    • /
    • 제12권3호
    • /
    • pp.171-181
    • /
    • 2002
  • 이온교환막의 전압-전류곡선의 plateau length를 결정하는 변수를 다양한 NaCl 농도와 유속 하에서 연구하였다. 또한, 한계전류밀도 이상의 전류에서 전기투석공정 운전의 타당성을 검토하기 위해 다양한 전류밀도의 전원을 공급하면서 0.1 M NaCl 용액의 탈염실험을 실시하여 이온의 제거효율, 전류효율, 에너지소비량, 물 분해 현상을 측정하였다. NaCl 용액의 농도와 유속이 감소하면서 확산경계층의 두께도 함께 감소하였으며, 본 확산경계층의 두께는 plateau length와도 밀접한 관련이 있는 것으로 나타났다. 탈염실험에서 측정된 이온 제거 효율 및 전류효율은 한계전류밀도 이상에서도 한계전류밀도 이하에서의 탈염실험과 크게 차이 나지 않은 것으로 보아 한계전류밀도 이상에서도 대부분의 전류는 이온교환막 표면의 물분해에 의한 것이 아니라 막을 통한 이온의 이동에 의한 것으로 사료된다. 한계전류밀도 이상에서의 탈염운전에 대한 에너지소비량은 plateau length의 영향으로 한계전류밀도 이하에서의 탈염운전 보다 다소 높지만, 한계전류밀도 이상에서는 전류밀도의 증가에도 에너지소비량이 증가하지 않았다. 이러한 결과들은 물분해 현상이 심각하게 일어나지 않는 한 한계전류밀도 이상에서도 매우 경제적으로 전기투석 공정을 운전찬 수 있다는 것을 제시해 주는 것이다.

Current Limiting Characteristics of a Flux-Lock Type SFCL for a Single-Line-to-Ground Fault

  • Oh, Geum-Kon;Jun, Hyung-Seok;Lee, Na-Young;Choi, Hyo-Sang;Nam, Gueng-Hyun
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.70-77
    • /
    • 2006
  • We have fabricated an integrated three-phase flux-lock type SFCL, which consists of an YBCO($YB_a2Cu_3O_7$) thin film and a flux-lock reactor wound around an iron core of each phase. In order to apply the SFCL in a real power system, fault analyses for the three-phase system are essential. The short-circuit currents were effectively limited by adjusting the numbers of winding of each secondary coil and their winding directions. The flux flow generated in the iron core cancelled out under the normal operation due to the parallel connection between primary and secondary windings. However, the flux-lock type SFCL with same iron core was operated just after the fault due to the flux generating in the iron core. To analyze the current limiting characteristics, the additive polarity winding was compared with the subtractive one in the flux lock reactor. Whenever a single line-to-ground fault occurred in any phase, the peak value of the line current of the fault phase in the additive polarity winding increased up to about 12.87 times during the first-half cycle. On the other hand, the peak value in the subtractive polarity winding increased up to about 34.07 times under the same conditions. This is because the current flow between the primary and the secondary windings changed to additive or subtractive status according to the winding direction. We confirmed that the current limiting behavior in the additive polarity winding was more effective for a single-line-to-ground fault

초전도소자의 트리거를 이용한 초전도 전류제한기의 전류제한 및 회복특성 분석 (Analysis on Current Limiting and Recovery Characteristics of a SFCL using a Trigger of Superconducting Element)

  • 임성훈
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.112-116
    • /
    • 2010
  • 본 논문에서는 고장발생 초기에 초전도 전류제한기를 구성하는 초전도 소자의 ��치발생을 검출하여 고장전류의 경로를 별도의 상전도 전류제한기로 우회시킴으로써 초전도 전류제한기의 회복시간을 단축시킬 수 있는 초전도소자의 트리거를 이용한 초전도 전류제한기의 전류제한 및 회복특성에 대해 분석하였다. 고장전류 크기를 조절하기 용이한 구성요소로 상전도 전류제한기의 저항크기에 따른 초전도 전류제한기를 구성하고 있는 전력용스위치의 개방시점과 투입시점의 변화를 비교하였으며, 분석을 통해 상전도 전류 제한기의 저항이 증가할수록 초전도 전류제한기를 구성하는 전력용스위치의 복귀시간이 길게 나타남을 확인할 수 있었다.

DC 그리드 안정성 향상을 위해 변압기형 초전도 한류기가 적용된 직류 차단 기술에 관한 연구 (A Study on DC Interruption Technology using a Transformer Type Superconducting Fault Current Limiter to Improve DC Grid Stability)

  • 황선호;최혜원;정인성;최효상
    • 전기학회논문지
    • /
    • 제67권4호
    • /
    • pp.595-599
    • /
    • 2018
  • Interruption system with the transformer type superconducting fault current limiter(TSFCL) is proposed in this paper. The interruption system with a TSFCL is a technology that it maximizes the interruption function of a mechanical DC circuit breaker using a transformer and a superconducting fault current limiter. By a TSFCL, the system limits the fault current till the breakable current range in the fault state. Therefore, the fault current could be cut off by a mechanical DC circuit breaker. The Interruption system with a TSFCL were designed using PSCAD/EMTDC. In addition, the Interruption system with a TSFCL was applied to the DC test circuit to analyze characteristics of a current-limiting and a interruption operation. The simulation results showed that the Interruption system with a TSFCL interrupted the fault current in a stable when a fault occurred. Also, The current-limiting rate of the Interruption system with a TSFCL was approximately 69.55%, and the interruption time was less than 8 ms.

전력계통에 초전도한류기 적용시 차단용량 확보를 위한 초전도한류기 적용방안 연구 (Analysis on the Application Capacity of the Superconducting Fault Current Limiter considering Reclosing and Fault Current)

  • 김진석;임성훈;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.592-593
    • /
    • 2015
  • Recently, the fault current has increased to exceed the rated breaking capacity of protective device due to the growth of the power demand on the power system where is changed into the loop-, mesh-, network grid. To limit fault current, the superconducting fault current limiter (SFCL) is announced with various methods. In many researches, the current limiting effect with the SFCL has been analyzed considering the rated breaking capacity of the CB with one fault condition. However, the power system has various short circuit and operation conditions. In order to select the capacity of the SFCL with reclosing operation and burden of the fault current on the protective device, the characteristics of the power system were investigated. Through the analysis, the evaluation method of the current rate was improved.

  • PDF

345kv한류리액터 운전에 따른 전력계통 동적안전도 해석 (Analysis of Power System Dynamic Security Due to Operation of 345kv CLR)

  • 이백석;강대언;이강완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.24-26
    • /
    • 2004
  • The growing demand for electricity has result in a corresponding increase in power generated and transmitted. As the increase in installed capacity of power system, the fault currents of 345kv system will be increased beyond the interrupting duty of the circuit breakers. The current limiting reactors are used to limit the fault current. The paper presents the result of the transient stability and voltage stability due to install 345kV current limiting reactor to suppress the fault currents.

  • PDF

초전도 코일을 이용한 DC 회로 차단기의 차단 능력 특성 (Characteristics of Interruption Ability in DC Circuit Breaker using Superconducting Coil)

  • 정인성;최혜원;윤정일;최효상
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.215-219
    • /
    • 2019
  • Development of DC interruption technology is being studied actively for enhanced DC grid reliability and stability. In this study, coil type superconductor DC circuit breaker was proposed as DC interruption. It is integration technology that combined current-limiting technique using superconductor and cut-off technique using mechanical DC circuit breaker. Superconductor was applied to the coil type. In simulation, Mayr arc model was applied to realize the arc characteristic in the mechanical DC circuit breaker. PSCAD/EMTDC had used to model and perform the simulation. To find out the protection range of coil type superconductor DCCB, the working operation have analyzed based on the rated voltage of DCCB. The results confirmed that, according to apply the limiting device, the protection range was increased in twice. Therefore, the probability of failure of interruption has lowered significantly.

Investigation on the inductive and resistive fault current limiting HTS power cable

  • Lee, Sangyoon;Choi, Jongho;Kim, Dongmin;Kwon, Yonghyun;Kim, Seokho;Sim, Kideok;Cho, Jeonwook
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권2호
    • /
    • pp.59-63
    • /
    • 2014
  • HTS power cable bypass the fault current through the former to protect superconducting tapes. On the other hand, the fault current limiting (FCL) power cable can be considered to mitigate the fault current using its increased inductance and resistance. Using the increased resistance of the cable is similar to the conventional resistive fault current limiter. In case of HTS power cable, the magnetic field of HTS power cable is mostly shielded by the induced current on the shield layer during normal operation. However, quench occurs at the shield layer and its current is kept below its critical current at the fault condition. Consequently, the magnetic field starts to spread out and it generates additional inductive impedance of the cable. The inductive impedance can be enhanced more by installing materials of high magnetic susceptibility around the HTS power cable. It is a concept of SFCL power cable. In this paper, a sample SFCL power cable is suggested and experimental results are presented to investigate the effect of iron cover on the impedance generation. The tests results are analyzed to verify the generation of the inductive and resistive impedance. The analysis results suggest the possible applications of the SFCL power cable to reduce the fault current in a real grid.