• Title/Summary/Keyword: Current harmonic cancellation

Search Result 6, Processing Time 0.019 seconds

HE Link Current-Fed Inverter for Fuel Cell Applications (연료전지 응용을 위한 HF Link 전류원 인버터)

  • Chung Se-Kyo;Shin Hwi-Beom;Lee Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.17-20
    • /
    • 2003
  • This paper presents a high frequency (HF) link current-fed inverter fur fuel cell applications. The circuit topology, operation and control method of the proposed HF link current-fed inverter are presented. The active cancellation technique of the 120Hz input harmonic current is also considered. The simulation results are provided to show the feasibility of the proposed inverter scheme.

  • PDF

Design and Implementation of an Active Power Filter Using Model Predictive Controller

  • Haeri, Mohammad;Zeinali, Mahdi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1975-1980
    • /
    • 2004
  • A parallel active power filter is designed and implemented to compensate for undesired current harmonics generated by a nonlinear load. The filter works based on PWM strategy and control signal is generated using a model predictive controller. To evaluate the achievements, a PI controller is also designed and implemented. Experimental results indicate about 50% increase in the efficiency over PI controller.

  • PDF

DSP Control of Three-Phase UPS Inverter with Output Voltage Harmonic Compensator (3상 UPS 인버터의 출력전압 왜형률 개선을 위한 고조파 보상기법의 DSP 제어)

  • 변영복;조기연;박성준;김철우
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.269-275
    • /
    • 1997
  • This paper presents real time digital signal processor(DSP) control of UPS system feeding processor(DSP) control of UPS system feeding nonlinear loads to provide sinusoidal inverter output voltage. The control scheme is composed of an rms voltage compensator, the load current harmonics feed-forward loop for the cancellation of output voltage harmonics, and the output voltage harmonics feedback loop for system stability. The controller employs a Texas Instruments TMS320C40GFL50 DSP.

  • PDF

A New Measurement Method of the Ground Resistance Using a Low-pass Filter in Energized Substations (지역필터를 이용한 수변전실 접지저항의 새로운 측정방법)

  • Lee, Bok-Hui;Eom, Ju-Hong;Lee, Seung-Chil;Kim, Seong-Won;An, Chang-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.387-393
    • /
    • 2001
  • This paper describes an advanced measuring method and precise evaluation of the ground resistance for the grounding system of energized substations and power equipments. A grounding system of substations consists of all interconnected grounding connections of grounded conductors, neutral ground wires, underground conductors of distribution lines, cable shields, grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding system of high voltage energized substations because of harmonic components caused by switched power supplies or overloads. The conventional fall-of-potential method may be subject to big error if stray ground currents and potentials are present. In this work, to improve the precision in measurements of the ground resistance by eliminating the effects of harmonic components and stray currents and potentials, the investigations of the ground resistance measurement by using a low pass filter in a model energized grounding system were conducted. The accuracy of ground resistance mesurements was evaluated as a function of the ratio of the test signal to noise (S/N). The errors due to the proposed ground resistance measurement method were decreased with increasing S/N and were less than 5[%] as S/N is 10. The proposed ground resistance measurement method appears to be considerably more accurate than the conventional fall-of -potential method. It is allows cancellation of the parasitic resistance of energized grounding systems, to employ the measurement method that allows cancellation of the parasitic effects due to other circulating ground currents and ground potential rises in practical situations.

  • PDF

Modular Multilevel Converter Based STATCOM Topology Suitable for Medium-Voltage Unbalanced Systems

  • Pirouz, Hassan Mohammadi;Bina, Mohammad Tavakoli
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.572-578
    • /
    • 2010
  • This paper discusses a transformerless shunt static compensator (STATCOM) based on a modular multilevel converter (MMC). It introduces a new time-discrete appropriate current control algorithm and a phase-shifted carrier modulation strategy for fast compensation of the reactive power and harmonics, and also for the balancing of the three-phase source side currents. Analytical formulas are derived to demonstrate the accurate mechanism of the stored energy balancing inside the MMC. Various simulated waveforms verify that the MMC based STATCOM is capable of reactive power compensation, harmonic cancellation, and simultaneous load balancing, while controlling and balancing all of the DC mean voltages even during the transient states.

Simulation for the analysis of distortion and electrical characteristics of a two-dimensional BJT (2차원 BJT의 전기적 특성 및 왜곡 해석 시뮬레이션)

  • 이종화;신윤권
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.4
    • /
    • pp.84-92
    • /
    • 1998
  • A program was developed to analyze the electrical characteristics and harmonic distrotion in a two-dimensional silicon BJT. The finite difference equations of the small signal and its second and thired harmonics for basic semiconductor equations are formulated treating the nonlinearity and time dependence with Volterra series and Taylor series. The soluations for three sets of simultaneous equations were obtained sequantially by a decoupled iteration method and each set was solved by a modified Stone's algorithm. Distortion magins and ac parameters such as input impedance and current gains are calculated with frequency and load resistance as parameters. The distortion margin vs. load resistancecurves show cancellation minima when the pahse of output voltage shifts. It is shown that the distortionof small signal characteristics can be reduced by reducing the base width, increasing the emitter stripe length and reducing the collector epitaxial layer doping concentration in the silicon BJT structure. The simulation program called TRADAP can be used for the design and optimization of transistors and circuits as well as for the calculation of small signal and distortion solutions.

  • PDF