• Title/Summary/Keyword: Current detection

Search Result 2,493, Processing Time 0.033 seconds

A survey on pesticide residues of imported fruits circulated in Gyeonggido (경기도내 유통 수입과실류의 잔류농약 실태조사)

  • Cho, Yun-Sik;Kang, Jeong-Bok;Kim, Yang-Hee;Jeong, Jin-A;Huh, Jeong-Weon;Lee, So-Hyun;Lim, Young-Sik;Bae, Ho-Jeong;Kang, Heung-Gyu;Lee, Jeong-Hee;Jung, Eun-Sook;Lee, Byoung-Hoon;Park, Yong-Bok;Lee, Jong-Bok
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.3
    • /
    • pp.195-201
    • /
    • 2012
  • We tested for pesticide residues in 124 samples of 22 different items of imported fruits circulated in Gyeonggido. Total 218 pesticides were analyzed by multi-residue method using gas chromatography/nitrogen phosphorus detector-electron capture detector (GC/NPD-ECD), time of flight/mass spectrometer (TOF/MS), ultra performance liquid chromatography/photo diode array (UPLC/PDA), high performance liquid chromatography/fluorescence detector (HPLC/FLD) and mass spectrometer (LC/MS/MS). The pesticides were detected in 18 fruits samples, ranging 0.003~0.3 mg/kg and no samples had violative residue. The separation test to 14 sample pesticides detected was conducted to monitor the current status of pesticide residues according to the partial characteristic. The pesticides were detected in 14 peels ranging 0.03~1.5 mg/kg and 2 fleshes in less than detection limits. These results indicate that imported fruits are safe when the human takes normally but even the small amount of pesticides is harmful when the human takes it in a prolonged period. Therefore, the pesticide residual amounts of imported friuts should be constantly monitored for food safety.

Evaluation of Serological Surveillance System for Improving Foot-and-Mouth Disease Control (구제역 관리를 위한 혈청학적 예찰계획 평가)

  • Pak, Son-Il;Shin, Yeun-Kyung
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.258-263
    • /
    • 2013
  • The primary goal of this study was to compute sample sizes required to achieve the each aim of a variety of foot-and-mouth disease (FMD) surveillance programs, using a statistically valid technique that takes the following factors into account: sensitivity (Se) and specificity (Sp) of diagnostic test system, desired minimum detectable prevalence, precision, population size, and desired power of the survey. In addition, sample sizes to detect FMD if the disease is present and also as proof of freedom were computed. The current FMD active surveillance programs consist of clinical, virological, and serological surveillance. For the 2012 serological surveillance, annual sample sizes (n = 265,065) are planned at four separate levels: statistical (n = 60,884) and targeted (n = 115,232) at breeding pig farms and slaughter house, in together with the detection of structural proteins (SP) antibodies against FMD (n = 88,949). Overall, the sample size was not designed taking the specific aims of each surveillance stream into account. The sample sizes for statistical surveillance, assuming stratified two-stage sampling technique, was based to detect at least one FMD-infected case in the general population. The resulting sample size can be used to obtain evidence of freedom from FMD infection, not for detecting animals that have antibodies against FMD virus non-structural proteins (NSP). Additionally, sample sizes for targeted surveillance were not aimed for the population at risk, and also without consideration of statistical point of view. To at least the author's knowledge, sampling plan for targeted, breeding pig farms and slaughter house is not necessary and need to be included in the part of statistical surveillance. Assuming design prevalence of 10% in an infinite population, a total of 29 animals are required to detect at least one positive with probability of 95%, using perfect diagnostic test system (Se = Sp = 100%). A total of 57,211 animals needed to be sampled to give 95% confidence of estimating SP prevalence of 80% at the individual animal-level with a precision of ${\pm}5%$, assuming 800 herds with an average 200 heads per farm, within-farm variance of 0.2, between-farm variance of 0.05, cost ratio of 100:1 of farm against animals. Furthermore, 779,736 animals were required to demonstrate FMD freedom, and the sample size can further be reduced depending on the parameters assumed.

Bioequivalence of Two Nilvadipine Tablet (닐바디핀 정제에 대한 생물학적 동등성 평가)

  • 김종국;이사원;최한곤;고종호;이미경;김인숙
    • Biomolecules & Therapeutics
    • /
    • v.6 no.3
    • /
    • pp.289-295
    • /
    • 1998
  • The bioequivalence of two nilvadipine products was evaluated in 16 normal male volunteers (age 22-32 yr, body weight 57-80 kg) following sidle oral dose. Test product was Overca $l_{R}$ tablet (Choong-Wae Pharm. Corp., Korea) and reference product was Nivadi $l_{R}$ tablet (Hyundai Pharm. Corp., Korea). Both products contain 4 mg of nilvadipine. One tablet of the test or the reference product was administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). The determination of nilvadipine was accomplished using a validated capillary column GC with electron-capture detection. As a result of the assay validation, the quantiflcation of nilvadipine in human plasma by this technique was possible down to 0.5 ng/ml using 1 ml of plasma. Absolute overall recovery from five replicate analyses of nilvadipine-spiked sample were 88.4$\pm$ 10.24% (mean$\pm$ 5.D.) for human plasma of 10 ng/ml. The coefficients of variation (C.V.) were less than 20% and the actual concentration of nilvadipine measured by GC ranged from 80 to 99% in all plasma. Average drug concentrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products (p>0.05); the area under the curve from time zero to 8 hr (AUCo-$_{8 hr}$) (22.8$\pm$5.90 vs 22.2$\pm$6.10 ng . hr/ml), maximum plasma concentration ( $C_{max}$) (10.0$\pm$2.85 vs 9.3$\pm$3.28 ng/ml) and time to reach maximum plasma concentration ( $T_{max}$) (1.2$\pm$0.31 vs 1.3 $\pm$0.47 hr). The differences of mean AU $Co_{8hr}$ $C_{max}$, and $T_{max}$ between the two products (2.25, 7.65, and 10.30%, respectively) were less than 20%. The power (1-$\beta$) and treaeent difference (7) for AU $Co_{8hr}$, and $C_{max}$ were more than 0.8 and less than 0.2, respectively. Although the power for Tmax was under 0.8, Tm\ulcorner of the two products was not significantly different from each other (p>0. 05). These results suggest that the bioavailability of Overeat tablet is not significantly different from that of Nivadil tablet. Therefore, two products are bioequivalent based on the current results.sults.lts.lts.lts.

  • PDF

Expression of Translationally Controlled Tumor Protein (TCTP) Gene of Dirofilaria immitis Guided by Transcriptomic Screening

  • Fu, Yan;Lan, Jingchao;Wu, Xuhang;Yang, Deying;Zhang, Zhihe;Nie, Huaming;Hou, Rong;Zhang, Runhui;Zheng, Wanpeng;Xie, Yue;Yan, Ning;Yang, Zhi;Wang, Chengdong;Luo, Li;Liu, Li;Gu, Xiaobin;Wang, Shuxian;Peng, Xuerong;Yang, Guangyou
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.1
    • /
    • pp.21-26
    • /
    • 2014
  • Dirofilaria immitis (heartworm) infections affect domestic dogs, cats, and various wild mammals with increasing incidence in temperate and tropical areas. More sensitive antibody detection methodologies are required to diagnose asymptomatic dirofilariasis with low worm burdens. Applying current transcriptomic technologies would be useful to discover potential diagnostic markers for D. immitis infection. A filarial homologue of the mammalian translationally controlled tumor protein (TCTP) was initially identified by screening the assembled transcriptome of D. immitis (DiTCTP). A BLAST analysis suggested that the DiTCTP gene shared the highest similarity with TCTP from Loa loa at protein level (97%). A histidine-tagged recombinant DiTCTP protein (rDiTCTP) of 40 kDa expressed in Escherichia coli BL21 (DE3) showed immunoreactivity with serum from a dog experimentally infected with heartworms. Localization studies illustrated the ubiquitous presence of rDiTCTP protein in the lateral hypodermal chords, dorsal hypodermal chord, muscle, intestine, and uterus in female adult worms. Further studies on D. immitis-derived TCTP are warranted to assess whether this filarial protein could be used for a diagnostic purpose.

Analytical Method Development and Monitoring of Residual Solvents in Dietary Supplements (건강기능식품 중 잔류용매 분석법 개발 및 모니터링)

  • Lee, Hwa-Mi;Shin, Ji-Eun;Jang, Young-Mi;Kim, Hee-Yun;Kim, Mee-Hye
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.390-397
    • /
    • 2010
  • Residual solvents in foods are defined as organic volatile chemicals used or produced in manufacturing of extracts or additives, or functional foods. The solvents are not completely eliminated by practical manufacturing techniques and they also may become contaminated by solvents from packing, transportation or storage in warehouses. Because residual solvents have no nutritional value but may be hazardous to human health, there is a need to remove them from the final products or reduce their amounts to below acceptable levels. The purpose of this study was to develop and evaluate an analytical method for the screening of residual solvents in health functional foods. Furthermore, the aim of this study was to constitute a reasonable management system based on the current state of the market and case studies of foreign countries. Eleven volatile solvents such as MeOH, EtOH, trichloroethylene and hexane were separated depending on their column properties, temp. and time using Gas Chromatography (GC). After determining the GC conditions, a sample preparation method using HSS (Head Space Sampling) was developed. From the results, a method for analyzing residual solvents in health functional foods was developed considering matrix effect and interference from the sample obtained from the solution of solvents-free health functional foods spiked with 11 standards solutions. Validation test using the developed GC/HSS/MS (Mass Spectrometry) method was followed by tests for precision, accuracy, recovery, linearity and adequate sensitivity. Finally, examination of 104 samples grouped in suits was performed by the developed HSS/GC/MS for screening the solvents. The 11 solvents were isolated from health functional foods based on vapor pressure difference, and followed by separation within 15 minutes in a single run. The limt of detection (LOD), limit of quantification (LOQ), recovery and coefficient of variation (C.V.) of these compounds determined by the HSS/GC/MS were found to be 0.1 pg/mL, 0.1-125 pg/g, 51.0-104.6%, and less than 15%, respectively. Using the developed HSS/GC/MS method, residual solvent from 16 out of 104 health functional products were detected as a EtOH. This method therefore seems t o be a valuable extension ofanalytical method for the identification of residual solvents in health functional food.

Determination of new anti-HIV agents, the KR-V series, in rat plasma using microbore high-performance liquid chromatography (HPLC를 이용한 랫드혈장내 새로운 항HIV제 KR-V series의 분석법)

  • Lee, Young-mi;Park, Myung-jin;Kim, Jin-suk;Shin, Ho-chul
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.4
    • /
    • pp.741-746
    • /
    • 2000
  • We have developed a rapid, simple and precise high-performance liquid chromatographic (HPLC) method using an UV detection system for the determination of new anti-HIV candidates, nineteen KR-V compounds, in rat plasma. We used a analytical columnn of $C_{18}$ ($5{\mu}m$, $250{\times}2.0mm$ I.D.) and a mobile phase of water and ACN mixture (40/60, v/v). Under these conditions, all the KR-V compounds were readily separated from plasma with retention times of 4-12 min. The limits of quantitation for the 19 KR-V compounds were 15-30 ng/ml. The recoveries from the plasma were higher than 85% (C.V.<10%) with exception of KR-V 2, 7 and 15. The compounds KR-V 2, 7 and 15, containing ester moieties, were found to be unstable in plasma. This result suggests that esters, like KR -V 2, 7 and 15, should be excluded from future structure design studies of anti-HIV KR-V agents. In conclusion, the current HPLC method is a valuable analytical tool for investigating the pharmacokinetics of the KR-V series in rats.

  • PDF

Analysis on Urinary N-methylformamide of Korean Workers according to Industrial Classification and Countermeasures for Exposure Control of N,N-dimethylformamide (우리나라 근로자들의 업종별 뇨중 N-methylformamide 분석 및 N,N-dimethylformamide 노출관리 대책)

  • Kim, Dohyung;Byun, Kiwhan;Park, Jae-Oh;Lee, Mi-Young;Kim, Eun-A
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.3
    • /
    • pp.345-352
    • /
    • 2014
  • Objectives: This study is aimed to describe the current situation about urinary biomarker N-methylformamide(NMF) for workers exposed to N,N-dimethylformamide(DMF) according to industrial classification. Materials: Special health examination records of the workers who had undergone urinary biological monitoring in 2013 were collected. The numbers and percentage of workers, whose urinary NMF values were above the limit of detection(LOD) and above the biological exposure index(BEI) were calculated. Health relatedness with DMF as judged by their doctors was also described. All description was classified according to the $9^{th}$ Korean Standard Industrial Classification(KSIC). Results: It appeared that most workers exposed to DMF belong to manufacturing section(80.7%). The geometric mean(GM) values of urinary NMF were 6.25 mg/L, 3.54, and 3.86 for the manufacturing section, professional, scientific and technical activities section, and for the construction section respectively. In detail, it seemed that division of textiles(except apparel) (GM 7.51 mg/L), division of leather, luggage and footwear(11.59 mg/L), and division of rubber and plastic products(6.89 mg/L) were highly exposed to DMF with a high percentage of workers with urinary NMF values above BEI. This was probably due to the effect of skin absorption that the division of leather, luggage and footwear showed the highest urine NMF GM. Conclusions: It seemed that workers in manufacture industries such as textile, leather, luggage, footwear, rubber and plastic products were highly exposed to DMF. So, efforts should be focused on those industries in order to effectively diminish worker's exposure. Further studies to compare DMF air-monitoring with bio-monitoring according to industrial classification should be considered.

Fundamental Studies on the Development of On-line Monitoring of Trace Mercury in Drinking Water (음용수 중 수은 연속자동측정시스템의 개발에 관한 연구)

  • Chang, Soo-Hyun;Kim, Hyo-Jin;Kim, Sun-Tae;Kim, Young-Man
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.299-305
    • /
    • 1999
  • The electrolyte cathode atomic glow discharge (ELCAD) is a new plasma source for direct determination of trace heavy metals in drinking and waste water. ELCAD has been successfully developed for on-line monitoring of heavy metals, however, shows difficulty to measure mercury. In this study, ELCAD has been modified to apply the atomic absorption spectrometry (AAS) for the direct determination of trace elements of mercury in flowing water.The fundamental characteristics of this new types of plasma source have been investigated and found that the pH of the solution, discharge voltage, and current are most important factors.The absorbance of 1.0 ppm Hg standard solution increases as pH of the solution increases from pH 1.0 to 3.0.However, % RSD of the absorbance also increases as the pH of solution increasesdue to plasma unstability.The detection limits of the standard solution of pH 1.5 and pH 3.0 are about 40 ppb and 10 ppb level, respectively.

  • PDF

The Study on the Analysis Method of Tetrodotoxin in Puffer Fish (복어 중 테트로도톡신 분석법에 관한 연구)

  • Kang, Young-Woon;Lee, Yoon-Suk;Park, Sung-Kug;Seo, Jung-Heok;Kim, Mee-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.1
    • /
    • pp.37-41
    • /
    • 2012
  • The current standard for testing tetrodotoxin (TTX) in foodstuffs is the mouse bioassay (MBA) in Korea as in many other countries. However, this test suffers from potential ethical concerns over the use of live animals. In addition, the mouse bioassay does not test for a specific toxin thus a sample resulting in mouse incapacitation would need further confirmatory testing to determine the exact source toxin (e.g., TTX, STX, brevotoxin, etc.). Furthermore, though the time of death is proportional to toxicity in this assay, the dynamic range for this proportional relationship is small thus many samples must be diluted and new mice be injected to yield a result that falls within the quantitative dynamic range. Therefore, in recent years, there have been many efforts in this field to develop alternative assays. High performance liquid chromatography (HPLC) coupled with mass spectrometry (MS) has been emerged as one of the most promising options. A LC-MS-MS method involves solid-phase extraction (SPE) and followed by analysis using an electrospray in the positive ionization mode and multiple reactions monitoring (MRM). To adopt LC-MS-MS method as alternative standard for testing TTX, we performed a validation study for the quantification of TTX in puffer fish. This LC-MS-MS method showed good sensitivity as limits of detection (LOD) of $0.03{\sim}0.08{\mu}g/g$ and limits of quantification (LOQ) of $0.10{\sim}0.25{\mu}g/g$. The linearity ($r^2$) of tetrodotoxin were 0.9986~0.9997, the recovery were 80.9~103.0% and the relative standard deviations (RSD) were 4.3~13.0%. The correlation coefficient between the mouse bioassay and LC/MS/MS method was higher than 0.95.

Monitoring of Veterinary Drug Residues in Cultured Fishery Products in Chungcheongnam-do Province (충남지역에서 생산되는 양식수산물의 잔류 동물용의약품 모니터링)

  • Lee, Kang-Bum;Kim, Nam-Woo;Kim, Dong-Uk;Sin, Myeong-Hee;Lee, Mi-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.5
    • /
    • pp.447-451
    • /
    • 2020
  • For this study, we conducted a simultaneous multiresidue analysis of veterinary drugs in cultured fishery products in Chungnam Province in 2018. A total of 115 fishery product samples were obtained from fish farms and fishery production sites located in the province. In all, 29 residual veterinary drugs in the samples were analyzed using a validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. As a result, veterinary drug residues were only detected in a small number of the 106 samples (92.2%), and the detection rate was 7.8% (9 of 115 samples). The amounts were also below maximum residual limit (MRL) for fishery products, although one sample exceeded the MRL allowed by the Ministry of Food and Drug Safety and was detected in loach. The nine residual veterinary drugs were detected in 8 samples: loach, eel, catfish, freshwater bream, flatfish, rockfish and shrimp. The detected veterinary drugs were oxolinic acid, enrofloxacin, ciprofloxacin, sulfadiazine, flumequine and oxytetracycline. The most frequently detected antibiotic was oxolinic acid, and enrofloxacin exceeded the MRL in loach sample. Residues of most veterinary drugs were either not detected or were below the MRL, and while the status of fishery products is seen as safe overall, current surveillance efforts over veterinary drugs should be continued.