• 제목/요약/키워드: Current detection

검색결과 2,501건 처리시간 0.035초

Islanding Detection Method for Inverter-Based Distributed Generation through Injection of Second Order Harmonic Current

  • Lee, Yoon-Seok;Yang, Won-Mo;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1513-1522
    • /
    • 2018
  • This paper proposes a new islanding detection method for inverter-based distributed generators by continuously injecting a negligible amount of 2nd order harmonic current. The proposed method adopts a proportional resonant (PR) controller for the output current control of the inverter, and a PR filter to extract the 2nd order harmonic voltage at the point of common coupling (PCC). The islanding state can be detected by measuring the magnitude ratio of the 2nd order harmonic voltage to the fundamental voltage at the PCC by injecting a 2nd order harmonic current with a 0.8% magnitude. The proposed method provides accurate and fast detection under grid voltage unbalance and load unbalance. The operation of the proposed method has been verified through simulations and experiments with a 5kW hardware set-up, considering the islanding test circuit suggested in UL1741.

신경회로망과 DWT를 이용한 고장표시기의 고장검출 개선에 관한 연구 (A Study for the Improvement of Fault Detection on Fault Indicator using DWT and Neural Network)

  • 홍대승;임화영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.46-48
    • /
    • 2007
  • This paper presents research about improvement of fault detection algorithm in FRTU on the feeder of distribution system. FRTU(Feeder Remote Terminal Unit) is applied to fault detection schemes for phase fault, ground fault, and cold load pickup and Inrush restraint functions distinguish the fault current and the normal load current. FRTU is occurred FI(Fault Indicator) when current is over pick-up value also inrush current is occurred FRTU indicate FI. Discrete wavelet transform(DWT) analysis gives the frequency and time-scale information. The neural network system as a fault detector was trained to discriminate inrush current from the fault status by a gradient descent method. In this paper, fault detection is improved using voltage monitoring system with DWT and neural network. These data were measured in actual 22.9kV distribution system.

  • PDF

Analysis of MODIS cloud masking algorithm using direct broadcast data over Korea and its improvement

  • Lee, H.J.;Chung, C.Y.;Ahn, M.H.;Nam, J.C.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.461-463
    • /
    • 2003
  • The information on the cloud presence within a instantaneous field of view is the first step toward the derivation of many other geophysical parameters. Here, we first applied the current MODIS cloud detection algorithm developed by University of Wisconsin and compared the results to a visual interpretation of composite data, especially during the daytime. Most of cases, the detection algorithm performs very well, except a few cases with over-detection. One of the reasons for the false detection is due to the time independent use of land information which affects the threshold values of visible channel test. In the presentation, we show detailed analysis of the current cloud detection algorithm and suggest possible way to overcome the current shortfall.

  • PDF

고정자 전류 스펙트럼 모니터링을 이용한 효과적인 유도전동기 회전자 고장 걸출 (Efficient Rotor Fault Detection of Induction Motors Using Stator Current Spectrum Monitoring)

  • 정춘호;우혁재;송명현;강의성;김경민
    • 한국정보통신학회논문지
    • /
    • 제6권6호
    • /
    • pp.873-878
    • /
    • 2002
  • 고정자 전류 스펙트럼(stator current spectrum)은 유도전동기의 고장 검출에 널리 사용되어왔다. 본 논문에서는 고정자 전류 스펙트럼 중에서 회전자 고장에 의해서 큰 영향을 받는 주파수 성분들로 특징벡터(feature vector)를 구성하고, 특징벡터와 기준벡터(reference vector)와의 평균 절대치 차이(mean absolute difference)를 구함으로써, 회전자 고장을 검출하는 방법을 제안한다. 제안한 방법에서는 전류 스펙트럼 중에서 추출된 매우 작은 크기(dimension)의 특징 벡터에 대한 평균 절대치 차이를 이용하기 때문에 신경회로망에 의한 고장 검출 알고리즘 둥에 비해서 훨씬 적은 계산량만으로 모터의 고장을 효율적으로 검출할 수 있다

원자로 제어봉구동장치 제어시스템의 전력변환기 사이리스터 고장 검출 (Fault Detection for thyristors of Power Converter Module in Control Rod Control System)

  • 김춘경;천종민;이종무;정순현;권순만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.559-562
    • /
    • 2003
  • In this paper, we introduce a new method detecting thyristor faults of the power converter module in Control Rod Control System. When we control the currents in each coil of Control Rod Drive Mechanism by using the current control method, the current value can follow the current reference despite the faults like the missing phase or the diode acting. Comparing the fault current values with the normal current values, the bad transient characteristics of the abnormal current can make the operations of control rods incorrect. In this case, the information from the current trends cannot be enough to detect the fault occurrence in thyristors. Instead of the coil currents, the state of thyristors can be watched by measuring the coil voltages. In the existing system of Westinghouse type, the ripple detector takes charge of this task. But this detector has some shortcomings in the point of time for fault detection, we come to devise a new fault detection method solving the problems which belong to the ripple detector.

  • PDF

HFCT를 활용한 고전압직류송전 케이블 부분방전 위치추정 (Detection and localization of partial discharge in high-voltage direct current cables using a high-frequency current transformer)

  • 홍선민;손우영;천혜원;강대경;박종후
    • 센서학회지
    • /
    • 제30권2호
    • /
    • pp.105-108
    • /
    • 2021
  • Detection and localization of partial discharge are considered critical techniques for estimating the lifetimes of power cables. High-frequency current transformers (HFCTs) are commonly used for the detection of partial discharge in high-voltage alternating current (HVAC) power cables; however, their applicability is compromised by the limitations of the installation locations. HFCTs are typically installed in cable terminals or insulation joint boxes because HVACs induce strong time-varying magnetic fields around the cables, saturating the ferromagnetic materials in the HFCTs. Therefore, partial discharges near the installation locations can be detected. In this study, the feasibility of partial discharge detection using a HFCT was investigated for high-voltage direct current (HVDC) cables. We demonstrated that the HFCT could be installed at any location in the HVDC power cable to monitor partial discharge along the entire cable length. Furthermore, we showed that the HFCT could detect the location of partial discharge with high accuracy.

DC 전류에 의한 직렬 아크 특성 분석 (Analysis of Serial Arc with DC Current)

  • 반기종;남문현;김낙교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1700-1701
    • /
    • 2007
  • DC Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, DC arc detection device is designed for the display of DC arc fault current which is occurred in the local electric network with DC Power. This DC arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and low frequency. DC Arc current detection device is designed for the display of arc fault current which has the modified arc characteristics.

  • PDF

Optical Characterization of Superconducting Strip Photon Detector Using $MgB_2$

  • Shibata, H.
    • Progress in Superconductivity
    • /
    • 제14권2호
    • /
    • pp.96-98
    • /
    • 2012
  • Bias current dependence of a superconducting strip photon detector is studied in the wavelength range of 405 to 1310 nm. The detector is made of an $MgB_2$ meander pattern with the line width of 135 nm and thickness of 10 nm. At 1310 nm, the detection efficiency exponentially decreases as the bias current decreases. While at 405 nm, the detection efficiency almost saturates in the high bias current region. These features suggest that the intrinsic detection efficiency of the $MgB_2$ detector is high at 405 nm.

능동전력필터를 위한 확장된 전류 동기 검출 알고리즘 (Algorithm of Extended Current Synchronous Detection for Active Power Filters)

  • 정영국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.111-114
    • /
    • 2000
  • Harmonics and fundamental reactive power of nonlinear loads in serious unbalanced power condition are compensated by current synchronous detection(CSD) theory which is also acceptable for single phase power system, but the CSD theory is not suitable any more in case of controlled independently harmonics and reactive component. Therefore a new algorithm the extended current synchronous detection (ECSD)theory for a three phase active power filter based on decomposition of fundamental reactive distorted components is proposed in this paper. The proposed ECSD theory is simulated and tested comparison with a few power theories under asymmtrical condition in power system.

  • PDF

멀티 콘센트용 변류기 및 과전류 검출 회로 설계 (Design of a Current Transducer and Over-Current Fault Detection Circuit for Power Strip Applications)

  • 김용재;김민석;박규상;김재홍
    • 한국전자통신학회논문지
    • /
    • 제10권8호
    • /
    • pp.921-926
    • /
    • 2015
  • 멀티 콘센트의 과전류로 인한 과열을 방지하기 위한 보호방식으로는 주로 금속바이메탈 방식, 스위칭회로 방식, 마이크로컨트롤러(MCU)를 이용한 과전류 정밀제어 방식 등이 사용되어 오고 있다. 하지만 이러한 방식들은 보호회로가 과전류가 흐르는 전선에 병렬접속 함으로써 2차 화재의 위험이 있을 수 있으며 입력전압의 비선형 왜곡에 취약한 단점을 가지고 있다. 또한 기존의 방식들은 제품의 단가가 비교적 크게 올라가므로 충분한 시장성을 확보하기가 쉽지 않다. 본 논문에서는 이러한 문제를 해결하고자 과전류가 흐르는 전선에 비접촉식 관통형 변류기를 설계하고 변류기의 2차 유도전류를 이용하여 과전류를 감지하여 사용자가 과전류 상황을 인지할 수 있도록 LED 및 부저 회로를 통하여 시각 및 청각적 신호를 전달하는 기능을 구현한다. 실험 결과들로부터 제안된 회로는 매우 경제적이고 간단하면서도 안정적으로 동작함을 확인 할 수 있다.