• 제목/요약/키워드: Current detection

검색결과 2,480건 처리시간 0.036초

DC전류검출기의 감도개선을 위한 자계변조 (Magnetic Modulation for the Improvement of sensitivity in DC Current sensor)

  • 이환;김한성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.791-793
    • /
    • 1993
  • The hall sensor is current detector using hall effect in semiconductor and the conventional type detect current with concentrating flux by current of conductor. So, detection of small current is very difficult because of residual magnetism. This paper give the experiments based results about method that detect the small DC current using minimizing the residual of hall element by magnetic modulation and concentrating flux. The suggested sensor can dector small current better than the conventional that.

  • PDF

방전등 안정기의 보호회로 기술 현황 (A Stuty of Protection Circuit for Discharge Lamp Ballast)

  • 한수빈;박석인;송유진;정학근;정봉만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.133-135
    • /
    • 2008
  • In a design of ballast for discharge lamp, various kind of protection circuit are essential for safe operation. In this paper, overvoltage and current detection, no-load detection, lamp-fault detection, end of lamp detection for protection are introduced. Individual circuit operation and their function are described with the base that all circuit form is similar with overvoltage protection circuit.

  • PDF

다중코일 와전류 센서 설계제작 및 특성분석 (The Design & Manufacture of Multi-coil Eddy Current Sensor and Characteristic Analysis)

  • 안연식;길두송;박상기
    • 동력기계공학회지
    • /
    • 제15권3호
    • /
    • pp.65-69
    • /
    • 2011
  • This paper introduces the multi-coil eddy current sensor and its characteristic in magnetic material gas turbine rotor. In the past, magnetic particle inspection method was used for qualitative defect evaluation in magnetic material gas turbine rotor. And the ultrasonic inspection method was used for quantitative defect evaluation. Nowadays, eddy current method is used in magnetic gas turbine rotor inspection due to advanced sensor design technology. We developed multi-coil eddy current sensor for the rotor dovetail inspection. At first, rotor stress is analyzed for the determination of sensor position and number. The sensor coils are designed to cover the stress concentration area of rotor dovetail. We select optimum frequency according to material standard penetration data and experiment results. The rotor mock-up and artificial defects were made for the signal detection and resolution analysis of multi-coil eddy current sensor. The results show that signal detection and resolution capabilities are enhanced in comparison to the commercialized sensor enough for the gas turbine rotor inspection. So, this developed multi-coil eddy current sensor substituted for commercialized one and it applied in real gas turbine rotor inspection.

저가형 교류전동기 벡터제어 인버터를 위한 새로운 전류측정 방법 (A Novel Current Sensing Method for Low-Cost Vector-Controlled Inverter of AC Motor)

  • 이원일;윤덕용
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.950-955
    • /
    • 2013
  • This paper proposes a new low-cost current detection method to implement vector-controlled inverter of 3-phase induction motor or permanent-magnet synchronous motor using 2 shunt resistors instead of expensive Hall current sensors. The proposed method can detect perfect phase currents without current-immeasurable area in all operating conditions of motor. This method uses 2 shunt resistors in Hall current sensor positions conventionally used to detect phase currents. Therefore, it requires accurate analog differential amplifiers to detect voltages across shunt resistors at high electric potential to ground. We show the good solutions which are implemented by voltage-divider resistors networks and the instrumentation amplifiers using several Op Amps at cheap price. Computer simulations and experiments were performed to confirm the effectiveness of proposed method. These results show that proposed method can perfectly detect phase currents without current-immeasurable area in all operating conditions of motor.

무정전 전원장치 효율 향상에 대한 연구 (Efficiency Improvement of Uninterruptible Power Supply Systems)

  • 오홍일;권종원;박용만;오드게럴;김희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.288-290
    • /
    • 2006
  • An efficiency improving method for Uninterruptible Power Supply System(UPS) was developed by using OP-AMP based application circuits such as voltage detection device, current detection device and static switch control device. The efficiency improving algorithm was made by mixing the operating concepts of On-Line type UPS with the operating concepts of Off-Line type UPS. The UPS' inverter does not work if the UPS' output load current is not higher than the low load operating current which is about 0-30(%) of the UPS' output load capacity. The low load operating current is adjustable within the half of the UPS' output load capacity. If the UPS' output load current is rising over than the low load operating current, the UPS' inverter starts working and the inverter output power feeds to the loads of UPS. If UPS' input power breaks out while UPS' inverter does not operate because the load current is low, the inverter starts working within 4(ms) with excessive output voltage which is ${\pm}$8(%) of normal UPS' output voltage. Like these. UPS can continuously feeds power to it's load device and reduce power consumptions.

  • PDF

차상기반 열차위치검지방식의 구성방안 연구 (The study on configuration method for the vehicle-based train position detection)

  • 신경호;정의진;김종기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.238-240
    • /
    • 2006
  • For the method of train position detection, ground-based train position estimation mainly has been applied so far. Ground-based position detection is the way to detect train current positions by installing train position equipments on railroad lines. However, the ground-based methods should install detection equipments on each section, and can only be able to detect train positions from main command center. So this method has several disadvantages such as an discontinuous position detection, an increment in cost of installation and maintenance. To make possible continuous train position detection, and to minimize amount of the cost, the vehicle-based position detection method should be chosen to determine train positions by loading position equipments on vehicles. In this paper, to realize the vehicle-based train position detection method, configuration scheme of train position detection equipment is suggested by using GPS, inertial sensor, speed sensor and its performance is verified by simulations.

  • PDF

A Low Power Analog CMOS Vision Chip for Edge Detection Using Electronic Switches

  • Kim, Jung-Hwan;Kong, Jae-Sung;Suh, Sung-Ho;Lee, Min-Ho;Shin, Jang-Kyoo;Park, Hong-Bae;Choi, Chang-Auck
    • ETRI Journal
    • /
    • 제27권5호
    • /
    • pp.539-544
    • /
    • 2005
  • An analog CMOS vision chip for edge detection with power consumption below 20mW was designed by adopting electronic switches. An electronic switch separates the edge detection circuit into two parts; one is a logarithmic compression photocircuit, the other is a signal processing circuit for edge detection. The electronic switch controls the connection between the two circuits. When the electronic switch is OFF, it can intercept the current flow through the signal processing circuit and restrict the magnitude of the current flow below several hundred nA. The estimated power consumption of the chip, with $128{\times}128$ pixels, was below 20mW. The vision chip was designed using $0.25{\mu}m$ 1-poly 5-metal standard full custom CMOS process technology.

  • PDF

계통연계형 태양광발전 인버터를 위한 주기적인 영전류 구간을 가지는 새로운 AFD 단독운전 검출기법 (Novel AFD method of islanding detection with a periodic zero current for improving on islanding detection for grid-connected Photovoltaic inverters)

  • 고문주;최익;최주엽;송승호;이기옥
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.17-23
    • /
    • 2006
  • This paper proposes a novel active frequency drift (AFD) method for the islanding prevention of grid-connected photovoltaic inverter. To detect the islanding phenomenon of grid-connected photovoltaic (PV) inverters concerning about the safety hazards and the damage to other electric equipments, many kinds of anti-islanding methods have been presented. Among them, AFD method using chopping fraction enables the islanding detection to drift up (or down) the frequency of the voltage during the islanding situation. In this paper, injecting the periodic zero current into the basic AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 1547 with various load conditions. Detection of islanding is verified using simulation tool PSIM.

Multiple Vehicle Detection and Tracking in Highway Traffic Surveillance Video Based on SIFT Feature Matching

  • Mu, Kenan;Hui, Fei;Zhao, Xiangmo
    • Journal of Information Processing Systems
    • /
    • 제12권2호
    • /
    • pp.183-195
    • /
    • 2016
  • This paper presents a complete method for vehicle detection and tracking in a fixed setting based on computer vision. Vehicle detection is performed based on Scale Invariant Feature Transform (SIFT) feature matching. With SIFT feature detection and matching, the geometrical relations between the two images is estimated. Then, the previous image is aligned with the current image so that moving vehicles can be detected by analyzing the difference image of the two aligned images. Vehicle tracking is also performed based on SIFT feature matching. For the decreasing of time consumption and maintaining higher tracking accuracy, the detected candidate vehicle in the current image is matched with the vehicle sample in the tracking sample set, which contains all of the detected vehicles in previous images. Most remarkably, the management of vehicle entries and exits is realized based on SIFT feature matching with an efficient update mechanism of the tracking sample set. This entire method is proposed for highway traffic environment where there are no non-automotive vehicles or pedestrians, as these would interfere with the results.