• 제목/요약/키워드: Current conditioning

검색결과 360건 처리시간 0.02초

Field Emission Stability of Carbon Nanotubes Grown by Thermal Chemical Vapor Deposition

  • Kim, B.K.;Kong, B.Y.;Seon, J.Y.;Lee, N.S.;Kim, H.J.;Han, I.T.;Choi, J.H.;Jung, J.E.;Kim, J.M.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.863-866
    • /
    • 2003
  • Multi-walled carbon nanotubes (CNTs) were synthesized on glass substrates in the different ramp-up heating ambient of vacuum, He, Ar, and $N_{2}$ by thermal chemical vapor deposition. CNTs with higher crystallinity were developed in the buffer gases with faster growth rates than in vacuum. Field emission characteristics were strongly related to the relative position of CNT emitters to the cathode electrodes. The areal-spread emission and instability were overcome by locating the emitters far away from the edges of cathode electrodes. The electrical conditioning of emitters improved their emission uniformity over a large area although it decreased the emission current. This study also discussed the long-term stability of CNT emitters.

  • PDF

응축수 중에서 가스보일러용 STS 304의 부식거동에 관한 연구 (The Study on the Corrosion Behavior of STS 304 for Gas Boiler in the Condensed Water)

  • 윤병두;임우조;정기철
    • 한국가스학회지
    • /
    • 제9권1호
    • /
    • pp.21-25
    • /
    • 2005
  • 가스보일러용 오스테나이트계 스테인리스강재(STS 304)의 부식거동에 관해 연구하기 위하여, 응축수중에서 전기화학적 부식시험을 수행하여. STS 304의 전기화학적 부식거동을 고찰하였다. 다음과 같은 결론을 얻었다. 1)중성환경인 pH=6.5에서 pH가 낮아질수록 STS 304의 분극저항은 감소하고, 부식전위는 비전위화된다. 2)중성 및 산성환경 중에서 STS 304의 부식반응기구는 음극지배로 판단된다. 3) pH가 중성 환경인 pH=6.5에서 강산성 환경인 pH=0.5로 낮아질수록 STS 304의 부동태 전위영역이 감소하고 부동태유지 전류밀도는 증가하고 있다.

  • PDF

석탄 화력발전소에서 발생되는 석탄회의 수분함유량 및 온도에 따른 비저항성 특성 연구 (A Study of Fly Ash Resistivity Characteristics Generated from the Coal Fired Power Plant as a Function of Water Concentration and Temperature)

  • 구재현;이정언;이재근
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.526-532
    • /
    • 2000
  • Recent studies have been directed toward obtaining a better understanding of the application of electrostatic precipitators to collect fly ash particles produced in a coal-fired power plant. Electrical resistivity can be described as the resistance of the collected dust layer to the flow of electrical current and is an important property for the collection efficiency in the electrostatic precipitator. In this paper, fly ash resistivity as a function of temperature up to $450^{\circ}C$ has been experimentally investigated using the resistivity meter consisted of the movable electrode, dust cup, and furnace. Resistivity was found to increase with increased temperature up to $200^{\circ}C$ due to the reduction of water concentration and then gradually decrease with increased temperature due to the activation of electrons. As the resistivity of fly ash in the flue gas temperature of $150^{\circ}C$ was measured >$10^{10}$ ohm cm, the efficiency of fly ash removal in the electrostatic precipitator might be expected to be low due to back-corona phenomenon. Flue gas conditioning in the electrostatic precipitator to reduce the resistivity of fly ash as required.

서울시내 여고생의 흡연행위 예측요인에 관한 연구 (Predictors of Cigarette Smoking Behavior among Girl high school students in Seoul)

  • 손정남
    • 여성건강간호학회지
    • /
    • 제6권2호
    • /
    • pp.316-329
    • /
    • 2000
  • The purpose of this study is to identify various predictors of smoking behavior among female adolescents. Data for this study was collected from 357 students enrolled in a female high school, a coeducational high school, and a vocational high school in Seoul from 1st to 20th July 1999 and this data was analysed based on descriptive statistics and logistic regression with the SAS program. The results were as follows: 1. The proportion of current smokers was 17.9% and experienced smokers was 34.2% in girl high schools. 2. According to the factors family, school, peer, social learning, and psychological factors, the predictable variables are lack of family attachment and function in family factors, school involvement in school factors, associating with smokers among peers and modeling and differential reinforcement of smoking in social learning factors, self-assertiveness, self-esteem, and depression in psychological factors. 3. According to all the factors, the main predictors were peer association, differential reinforcement of smoking, and lack of family attachment. These variables cause 48.4% of smoking behavior. To prohibit smoking among female students, this society should develop a program to focus on peer leadership about quitting smoking, acquirement of skills of refusal for smoking, counter conditioning, reinforcement management, and support system about nonsmoking.

  • PDF

대용량 태양광 발전용 멀티센트럴 시스템 (Multi-Central System for Large Scale PV Power Generation)

  • 박종형;고광수;김흥근;노의철;전태원
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.427-432
    • /
    • 2012
  • This paper proposes efficient operation method of PV system consisted of multi-central which is suitable for large scale system. The multi-central system used switch at a DC-link and applied proposed algorithm can improve the efficiency and the reliability on the existing system. This algorithm, with advantage of Multi-Central system can minimize the effect of different characteristic of each PV array due to a shadow or damaged PV cell. Each system is analysed and maximum power point tracking control, DC-link voltage control and output current control is used commonly. The validity is verified after comparing of the existing system and proposed system by simulation.

  • PDF

환경보건학적 관점에서 본 메르스 사태의 문제점 - 병원 실내공기질 관리를 중심으로 - (Problems of the Middle East Respiratory Syndrome Outbreak from the Perspective of Environmental Health - Focusing on Control of Indoor Air Quality in Hospitals -)

  • 허다안;이정현;허은혜;문경환
    • 한국환경보건학회지
    • /
    • 제41권3호
    • /
    • pp.216-221
    • /
    • 2015
  • Since Patient Zero of MERS was diagnosed in May 20, 2015, cases of MERS continued to grow. The current situation, which people have been confirmed to be infected, suggested that contaminated indoor air could be the potential cause of hospital-acquired infections. It is important to address the indoor air quality in hospitals because pathogens can spread through air. While the heating, ventilating and air conditioning(HVAC) system is useful managing indoor air quality in hospitals, it can transmit the pathogens if operated improperly. Therefore, it is necessary to remove contaminants in hospitals and operate the HVAC system according to the guidelines, in order to maintain clean indoor air.

주거 공간에서의 룸 에어컨디셔너 실내기 유형에 따른 온열쾌적성 및 에너지성능 평가 (Evaluation of Thermal Comfort and Energy Efficiency According to Indoor-Unit Types of Room Air-Conditioner in Housing Space)

  • 석호태;김동우;양정훈
    • 한국주거학회논문집
    • /
    • 제20권4호
    • /
    • pp.19-29
    • /
    • 2009
  • The purpose of this study is to evaluate the air diffusion performance of a range of indoor units for room airconditioners; the wall-mounted type, floor-standing type, and ceiling-mounted type. These types of units, which have been widely used in housing spaces, will be studied with respect to thermal comfort and the energy performance using CFD analysis. In this study, current air conditioning status and related problems in housing spaces are examined, and a CFD analysis is performed in order to compare and analyze the thermal comfort and energy efficiency across each type of indoor-unit using the PMV, ADPI, EUC and FCEI indexes. The analysis results collectively considering thermal comfort and energy performance indicated that the ceiling-mounted type 4-way indoor unit showed the best diffusion performance in terms of thermal comfort, and had the second best diffusion performance in terms of energy performance after the wall-mounted type under certain conditions.

차량 내 탑승자 상태 인식용 적외선 센서의 제조 및 특성 (Fabrications and Characteristics of Infrared Sensor for Passenger Conditional Detection in Vehicle)

  • 이성현;남태운
    • 한국전기전자재료학회논문지
    • /
    • 제22권3호
    • /
    • pp.222-229
    • /
    • 2009
  • A noble infrared sensor was studied for passenger conditional detection in vehicle, This research relates to uncooled infrared sensors for detecting the presence, type and temperature of occupants in vehicle. It sense that the occupants purpose to control the smart airbag for safety in the case of adult or child and to control the automatic air conditioning for convenience. This paper described the design and the fabrication of microbolometers which were composed of 2 by 8 elements using the surface micromachining technology. The characteristics of the array were investigated in the spectral region of $8{\sim}12{\mu}m$. The fabricated detectors exhibited the thermal mass of $7.05{\times}10^{-9}\;J/K$, the thermal conductance of $1.03{\times}10^{-6}\;W/K$, the thermal time constant of 6.8 ms, the responsivity of $2.96{\times}10^4\;V/W$ and the detectivity of $1.01{\times}10^9\;cmHz^{1/2}/W$, at the chopper frequency of 10 Hz and the bias current of $4.4{\mu}A$. We could successfully detect the human body condition in the divided zone. As a results, we concluded that microbolometer optimized in this research could be useful for the application of passenger conditional detection in vehicle.

There-Phase Voltage-Source Soft-Switching Inverter with Auxiliary High Frequency Transformer Linked Power Regeneration Resonant Snubbers

  • Hattori, Hiroshi;Nakaoka, Mutsuo;Sakamoto, Kenji
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.153-158
    • /
    • 1998
  • In this paper, a prototype of the auxiliary resonant commutated snubber circuit(ARCS) with a high frequency transformer power regeneration loop is described for voltage source type sinewave inverter system. This is a new soft switching topology developed for three phase voltage source soft-switching inverter, active power filter and reactive power compensator has significant advantage of current rating reduction for auxiliary active switching devices. In addition, this paper presents a novel prototype of voltage-source soft switching space vector-modulated inverter with ARCS mentioned above, which is more suitable and acceptable for high-power utility interactive power conditioning, along with a digital control scheme. The steady-state operating analysis of ARCS has the remarkable features and the practical design procedure of this resonant snubber are illustrated on the basis of computer simulation analysis. The operating performance evaluations in the steady-state of this three phase voltage source soft switching inverter are discussed and compared with the three phase voltage source hard switching inverter.

  • PDF

Utility-Connected Solar Power Conditioner Using Edge-Resonant Soft Switching Duty Cycle Sinewave Modulated Inverter Link

  • Ogura, Koki;Chandhaket, Srawouth;Nakaoka, Mutsuo;Terai, Haruo;Sumiyoshi, Shinichiro;Kitaizumi, Takeshi;Omori, Hideki
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.181-188
    • /
    • 2002
  • The utility interfaced sinewave modulation Inverter for the solar photovoltaic power conditioner with a high frequency transformer is presented for residential applications. As compared with the conventional full-bridge hard switching slnewave PWM inverter with a high frequency link, the simplest single-ended edge-resonant soft switching sinewave inverter with a sinewave duty cycle pulse control scheme is implemented, resulting in size and weight reduction, low cost and high efficiency This paper presents a prototype system of the sinewave zero voltage soft switching sinewave inverter for solar power conditioner, along with its operating principle and unique features. In addition to these, this paper discusses a control implementation to deliver high quality output current. Major design of each component and the power loss analysis under actual power processing is also discussed and evaluated from an experimental point of view A newly developed utility-connected sinewave power conditioning circuit which achieves 92.5% efficiency under 4kW output is demonstrated.