• 제목/요약/키워드: Current compensation method

검색결과 547건 처리시간 0.027초

추력리플 보상을 통한 영구자석형 선형 동기전동기의 제어특성 향상 (Improvement of Control Characteristics of Permanent Magnet Linear Synchronous Motor by Compensation of Thrust Ripple)

  • 정인성;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.16-18
    • /
    • 1998
  • In this paper, a control method based on finite element analysis is presented to reduce the thrust ripple of the permanent magnet linear synchronous motor (PMLSM). In the control method, additional compensation current is added to the conventional control current according to the position of mover. The exact value of the compensation current is calculated from finite element analysis. To conform the validity of the presented method, a test set is built and experiments are performed.

  • PDF

소규로 태양광 발전시스템을 위한 전류보상기법을 갖는 향상된 MPP 추적 컨버터 (An Improved MPPT Converter with Current Compensateion Method for Small Scaled PV-Applications)

  • 노형주;이동윤;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.580-583
    • /
    • 2002
  • An improved MPPT converter with current compensation method for small-scaled PV-applications is presented in this paper. The proposed method implements maximum power point tracking (MPPT) by variable reference current which is continuously changed during one sampling period. Therefore, the power transferred to the load is increased above $9\%$ by the proposed MPPT converter with current compensation method. As a result, the utilization efficiency of Photovoltaic (PV)-panel can be increased. In addition, as it doesn't use digital signal processor (DSP), this MPPT method has the merits of both a cost efficiency and a simple control circuit design. Therefore, it is considered that the proposed MPPT method is proper to low power, low cost PV-applications. The concept and control principles of the proposed MPPT method are explained in detail and its validity of the proposed method is verified through several simulated results.

  • PDF

단상 액티브 파워 필터를 위한 새로운 전류 보상 방법 (A New Current Compensation Estimation Method For Single Phase Active Power Filter)

  • 곽상신;이무영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.819-822
    • /
    • 1998
  • A new active power filter (APF) circuit with a current compesation estimation method is proposed. The current compensation estimation method replaces a current sensor with an estimating circuit and therefore reduces the implementation cost In addition, a simple control scheme, based on the energy balance concept, is adopted to control the voltage of a DC capacitor. Therefore energy change in the DC capacitor can be compensanted in the next cycle. Since a sampling technique is used, a larger DC capacitor voltage ripple can be permissible and a relatively smaller DC capacitor can be used. The proposed method has advantages of the reduction of one current sensor, low implementation cost, and fast transient responses. The theoretical analysis and simulation results are given. The proposed control method is successfully verified by computer simulation.

  • PDF

3상 양방향 인버터의 계통전압 불평형 및 왜곡에 의한 계통전류 보상 (The Compensation of the Grid Current Distortion caused by the Grid Voltage Unbalance and Distortion for 3-Phase Bi-Directional DC to AC Inverter)

  • 양승대;김승민;최주엽;최익;송승호;이상철;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제32권spc3호
    • /
    • pp.228-234
    • /
    • 2012
  • This paper presents the algorithm of the compensation of the grid current distortion caused by the grid voltage unbalance and distortion in 3-phase bi-directional DC to AC inverter. Usually 3-phase grid system has unbalance and distortion because of connecting 1-phase and non-linear load with 3-phase load using same input node. Controlling 3-phase inverter by general method under the unbalanced and distorted grid voltage, the grid current has distortion. This distortion of the grid current cause the grid voltage distortion again. So, it need to control the grid current balanced and non-distorted, even the grid voltage gets unbalanced and distorted. There are some complex method to compensate the gird current distortion. it sugest simple method to solve the problem. PSIM simulation is used to validate the proposed algorithm.

Peak-Valley Current Mode Controlled H-Bridge Inverter with Digital Slope Compensation for Cycle-by-Cycle Current Regulation

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Park, Joung-Hu
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.1989-2000
    • /
    • 2015
  • In this paper, digital peak current mode control for single phase H-bridge inverters is developed and implemented. The digital peak current mode control is achieved by directly controlling the PWM signals by cycle-by-cycle current limitation. Unlike the DC-DC converter where the output voltage always remains in the positive region, the output of DC-AC inverter flips from positive to negative region continuously. Therefore, when the inverter operates in negative region, the control should be changed to valley current mode control. Thus, a novel control logic circuit is required for the function and need to be analyzed for the hardware to track the sinusoidal reference in both regions. The problem of sub-harmonic instability which is inherent with peak current mode control is also addressed, and then proposes the digital slope compensation in constant-sloped external ramp to suppress the oscillation. For unipolar PWM switching method, an adaptive slope compensation in digital manner is also proposed. In this paper, the operating principles and design guidelines of the proposed scheme are presented, along with the performance analysis and numerical simulation. Also, a 200W inverter hardware prototype has been implemented for experimental verification of the proposed controller scheme.

데드타임 보상이 적용된 PMSM 전류 제어 (A current control with dead time compensation for PMSM)

  • 김건수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.219-223
    • /
    • 2000
  • In this paper a new current controller with dead time compensation for small time constant PMSM is proposed. Precise analysis on voltage distortion by dead time and device characteristics is presented. Simulation results are presented to demonstrated the validity of the proposed method.

  • PDF

Compensation of Current Offset Error in Half-Bridge PWM Inverter for Linear Compressor

  • Kim, Dong-Youn;Im, Won-Sang;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1593-1600
    • /
    • 2015
  • This paper proposes a novel compensation algorithm of current offset error for single-phase linear compressor in home appliances. In a half-bridge inverter, current offset error may cause unbalanced DC-link voltage when the DC-link is comprised of two serially connected capacitors. To compensate the current measurement error, the synchronous reference frame transformation is used for detecting the measurement error. When an offset error occurs in the output current of the half-bridge inverter, the d-axis current has a ripple with frequency equal to the fundamental frequency. With the use of a proportional-resonant controller, the ripple component can be removed, and offset error can be compensated. The proposed compensation method can easily be implemented without much computation and additional hardware circuit. The validity of the proposed algorithm is verified through experimental results.

내삽법 기반의 최소자승법을 이용한 개선된 CT 포화 복원 알고리즘 (An Enhanced Compensation Algorithm for the CT Saturation Using Interpolation-based LSQ(Least Square) Fitting Method)

  • 류기찬;강상희;이봉현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.14-15
    • /
    • 2006
  • A saturation of magnetic flux in the core may occur when a large primary current flows when the iron-cored current transformer is used. This saturation makes the distorted secondary current of the CT. the distorted secondary current may cause the mal-operation or operation time delay of protective relays. CT compensation algorithm using The LSQ(Least Square) fitting method has a problem. It needs to acquire enough data for executing this algorithm without an error. In this paper, an enhanced algorithm using interpolation based LSQ(Least Square) Fitting Method is proposed. The Lagrange Interpolation Method is used for the interpolation and CT is simulated by EMTP. The results show that the proposed algorithm can accurately compensate a distorted secondary current more than existing Algorithm when the saturation severely occurs.

  • PDF

입력 신호의 전치 보상을 이용한 D 급 음향 전력 증폭기의 스피커 전류 구동 방법 (Method for Current-Driving of the Loudspeakers with Class D Audio Power Amplifiers Using Input Signal Pre-Compensation)

  • 은창수;이유칠
    • 한국멀티미디어학회논문지
    • /
    • 제21권9호
    • /
    • pp.1068-1075
    • /
    • 2018
  • We propose a method for driving loudspeakers from class D audio power amplifiers in current mode, instead of in conventional voltage mode, which was impossible with the feedback circuitry. Unlike analog audio amplifiers, Class D audio power amplifiers have signal delay between the input and output signals, which makes it difficult to apply the feedback circuitry for current-mode driving. The idea of the pre-distortion scheme used for the compensation of the non-linearity of RF power amplifiers is adapted to remedy the impedance variation effect of the loudspeakers for current driving. The method uses the speaker model for the pre-distorter to compensate for the speaker impedance variation with frequency. The simulation and test results confirms the validity of the proposed method.

3상 인버터에 대한 간단한 데드타임 보상 알고리즘 (Dead Time Compensation Algorithm for the 3-phase Inverter)

  • 김홍민;백승호;안진우;이동희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.71-72
    • /
    • 2011
  • This paper presents a novel and direct dead time compensation method of the 3 phase inverter using space vector pulse width modulation(SVPWM) topology. In the turn on time calculation of the effective voltage, the dead time effect is directly compensated according to the current direction of the midium voltage reference. Since the turn on time of the effective voltage vector is affected by the dead time, the loss time is compensated to turn on time of the effective voltage vector. And the dead time is added to the calculated voltage vector switching times according to the current direction. For the more effective compensation, the direction of the midium phase current is considered by the practical direction and voltage drops in the power devices. The proposed method can compensate the dead time which is considered feedback error or direction of middle phase current without coordinate transform in added controller. The proposed dead time compensation scheme is verified by the computer simulation and experiments of 3 phase R L load.

  • PDF