Simplified Control Scheme of Unified Power Quality Conditioner based on Three-phase Three-level (NPC) inverter to Mitigate Current Source Harmonics and Compensate All Voltage Disturbances

  • Salim, Chennai;Toufik, Benchouia Mohamed
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.544-558
    • /
    • 2013
  • This paper proposes a simplified and efficient control scheme for Unified Power Quality Conditioner (UPQC) based on three-level (NPC) inverter capable to mitigate source current harmonics and compensate all voltage disturbances perturbations such us, voltage sags, swells, unbalances and harmonics. The UPQC is designed by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The dc voltage is maintained constant using proportional integral voltage controller. The shunt and series AF are designed using a three-phase three-level (NPC) inverter. The synchronous reference frame (SRF) theory is used to get the reference signals for shunt and the power reactive theory (PQ) for a series APFs. The reference signals for the shunt and series APF are derived from the control algorithm and sensed signals are injected in tow controllers to generate switching signals for series and shunt APFs. The performance of proposed UPQC system is evaluated in terms of power factor correction and mitigation of voltage, current harmonics and all voltage disturbances compensation in three-phase, three-wire power system using MATLAB-Simulink software and SimPowerSystem Toolbox. The simulation results demonstrate that the proposed UPQC system can improve the power quality at the common connection point of the non-linear load.

커넥터에서 접촉불량 발생시의 전압, 전류 및 온도 신호 특성 분석 (Analysis of Voltage, Current and Temperature Signals for Poor Connections at Electrical Connector)

  • 김상철;김두현;강신욱
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.12-17
    • /
    • 2014
  • This paper is aimed to analyze the characteristics of simultaneous voltage, current and temperature signals for poor connection on electrical connector. In order to attain this purpose, detected were the current and voltage signals on electric wire with series arc, named arc signals, and also monitored were the changes of RMS, instantaneous value of waveform in time domain and temperature value with video. Two states are made normal state over $5kgf{\cdot}cm$ and poor connections state below $0.5kgf{\cdot}cm$ by screw gage. In the voltage signal case, the voltage drop was increased with which the current was increased. In the current signal case, poor connections at the time interval 1~4A all showed "shoulder", as distinct difference from the normal state shown waveform pattern. In the temperature signal case, poor connections are twice at 1A and five times at 4A in the normal state. The temperature continues insulation of electrical wiring and connector can be carbonized. The results of this study will be effectively used in developing the preventive devices and system for electric fire by poor connections.

3단 스피드 선풍기 모터의 정상 및 고정 운전에 대한 전압, 전류 및 온도 신호 분석 (Analysis on the Voltage, Current and Temperature Signals for Free and Locked Operation of Three Speed Electric Fan)

  • 김윤복;김두현
    • 한국화재소방학회논문지
    • /
    • 제28권3호
    • /
    • pp.87-91
    • /
    • 2014
  • 본 논문은 선풍기 모터의 회전을 정상 및 고정상태로 구분하여 주권선에서의 전압 및 전류, 모터 전체의 온도특성을 분석하여 전기화재 위험성을 제시하는 것을 목표로 하고 있다. 전압과 전류 신호에 대하여, 전압의 경우 정상상태와 고정상태에 대하여 큰 차이점은 없었으며, 전류의 경우는 비정상상태(최대 203 mA)보다 정상상태(최대 309 mA)가 상당히 높았다. 온도신호의 경우, 모터 전반에 있어서 온도 분포도가 다르게 나타났으며, 정상상태의 경우는 $4^{\circ}C$, 고정상태는 $18^{\circ}C$ 차를 보였다. 특히 대부분의 선풍기의 전기배선이 모터의 고정자철심에 부착되어 있었으며 해당전선의 허용온도가 $60^{\circ}C$를 감안했을 때에 절연열화가 가속될 수 있다. 또한 본 데이터는 선풍기 안전장치개발의 기초자료나 전기화재에 대한 조사 자료로 활용할 수 있다.

배선에서 전기화재 전조신호 검출을 위한 H/W 및 S/W 구축 (Development of H/W and S/W for Detecting Electrical Fire Precursor Signal on Electrical Wirings)

  • 김성철;김두현
    • 한국안전학회지
    • /
    • 제24권3호
    • /
    • pp.13-18
    • /
    • 2009
  • This paper is purposed to develop DAQ H/W, S/W and DB which can be used in developing electrical fire alarm system or in analyzing electrical fire cause, by detecting and monitoring precursor signals which have high possibility leading to electrical fire on electrical distribution wires. In this paper, developed was DAQ H/W adopting the C8051FXXX CPU which can analyze the measurement signals of current and voltage in electrical distribution wires, other CPU was investigated in view of the best digital sampling rate on the basis of previous researches for electrical fire alarm system. Also, the S/W which can interface with DAQ H/W's communication protocol and can be applied for electrical fire causes analysis, are embodied by LabVIEW. The combined DAQ H/W and S/W could analyze efficiently normal as well as abnormal electrical signals such as RMS value, instantaneous value of current and voltage, frequency signals etc, on the electrical wires. Also, DB system was constructed for recording various analysis results for precursor signals including voltage and current signals. The results by simulator and experiment showed that the suggested scheme with DAQ H/W, S/W and DB in this paper has high usability.

A Novel Control Strategy of Three-phase, Four-wire UPQC for Power Quality Improvement

  • Pal, Yash;Swarup, A.;Singh, Bhim
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 2012
  • The current paper presents a novel control strategy of a three-phase, four-wire Unified Power Quality (UPQC) to improve power quality. The UPQC is realized by the integration of series and shunt active power filters (APF) sharing a common dc bus capacitor. The realization of shunt APF is carried out using a three-phase, four-leg Voltage Source Inverter (VSI), and the series APF is realized using a three-phase, three-leg VSI. To extract the fundamental source voltages as reference signals for series APF, a zero-crossing detector and sample-and-hold circuits are used. For the control of shunt APF, a simple scheme based on the real component of fundamental load current (I $Cos{\Phi}$) with reduced numbers of current sensors is applied. The performance of the applied control algorithm is evaluated in terms of power-factor correction, source neutral current mitigation, load balancing, and mitigation of voltage and current harmonics in a three-phase, four-wire distribution system for different combinations of linear and non-linear loads. The reference signals and sensed signals are used in a hysteresis controller to generate switching signals for shunt and series APFs. In this proposed UPQC control scheme, the current/voltage control is applied to the fundamental supply currents/voltages instead of fast-changing APF currents/voltages, thus reducing the computational delay and the required sensors. MATLAB/Simulink-based simulations that support the functionality of the UPQC are obtained.

선로고장시 발생되는 잡음의 시뮬레이션 (The Simulation of Transmission Line Fault-Induced Noise Signals.)

  • 신명철;김두웅;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.454-456
    • /
    • 1987
  • A more specialized area of transient evaluations is transmission line fault-detecting and protection system. During the first cycle or two following a power system fault, a high-speed protective relay is expected to make a decision as to the severity or location of the fault, usually based on 60 Hz information, i.e. the phase and magnitude of 60 Hz voltage or current signals. It is precisely at this time however that the signal is badly corrupted by noise, in the form of a de offset or frequencies above 50 Hz. One of several possible sources of transients in protection measuring signals is in the primary system for which protection is required in its response to the impact of short circuit fault on-set. Other sources are in the primary voltage and current transducers from which protection signals are derived, and, often of particular importance, in the interface circuits between the transducer secondaries and the comparator and measuring elements of the protection system. However, the noise signals that will be described in this paper are due to the main power system only and do not include errors due to current or voltage transducers.

  • PDF

Quadrature Oscillators with Grounded Capacitors and Resistors Using FDCCIIs

  • Horng, Jiun-Wei;Hou, Chun-Li;Chang, Chun-Ming;Chou, Hung-Pin;Lin, Chun-Ta;Wen, Yao-Hsin
    • ETRI Journal
    • /
    • 제28권4호
    • /
    • pp.486-494
    • /
    • 2006
  • Two current-mode and/or voltage-mode quadrature oscillator circuits each using one fully-differential second-generation current conveyor (FDCCII), two grounded capacitors, and two (or three) grounded resistors are presented. In the proposed circuits, the current-mode quadrature signals have the advantage of high-output impedance. The oscillation conditions and oscillation frequencies are orthogonally (or independently) controllable. The current-mode and voltage-mode quadrature signals can be simultaneously obtained from the second proposed circuit. The use of only grounded capacitors and resistors makes the proposed circuits ideal for integrated circuit implementation. Simulation results are also included.

  • PDF

Breakdown Properties in Physiological Saline by High Voltage Pulse Generator

  • Byeon, Yong-Seong;Song, Ki-Baek;Uhm, Han-Sup;Shin, Hee-M.;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.333-333
    • /
    • 2011
  • We have investigated the breakdown properties in liquids by high voltage pulse system. High voltage pulse power system is consisted of the Marx-generator with two capacitors (0.5 ${\mu}F$, withstanding voltage is 40 kV), to which the charging voltage can be applied to maximum 30 kV DC, spark gap switch and charging resistor of 20 $M{\Omega}$. We have made use of tungsten pin electrodes of anode-cathode (A-K), which are immersed into the liquids. The breakdown voltage and current signals are measured by high voltage probe (Tektronix P6015A) and current monitor (IPC CM-1.S). Especially the high speed breakdown or plasma propagation characteristics in the pulsed A-K gap have been investigated by using the high speed ICCD camera. We have measured the electron temperature through the Boltzmann plot method from the breakdown spectrums. Here the A-K gap has been changed by 1 mm, 2 mm, and 3 mm. The used liquids are distilled water and solution of salt (0.9 %). The output voltage and current signals at breakdown in distilled water are shown to be bigger than those in saline solution. The breakdown voltage and current characteristics in liquids will be discussed in accordance with A-K gap distances. It is also found that the electron temperatures and plasma densities in liquids are decreased in conformity with A-K gap.

  • PDF

직렬아크에 대한 전류 및 전압 신호분석이 가능한 Monitoring Program 개발 (Development of Monitoring Program for Detecting Current and Voltage Signals for Series Arc)

  • 김두현;박종영;김성철;이종호
    • 한국안전학회지
    • /
    • 제25권2호
    • /
    • pp.29-34
    • /
    • 2010
  • This paper is aimed to develop monitoring software for detecting the characteristics of current and voltage signals for series arc on electric wire. In order to attain this purpose, the characteristics of series arc were analyzed by the current and voltage signals on electric wire which were installed, and also analyzed by the changes of RMS, instantaneous of waveform value in time domain and THD in frequency domain. Monitoring program which analyze the signal was developed by Labview which can analyze in time domain and frequency domain, and save data. Experimental setup for detecting verification of monitoring program was composed loads of a lamp, an electric heater and an electric fan loads which were usually using. Measurement points for detecting verification of monitoring program were selected at both the panel board and the arc generator at the same time. As results of the experiments by monitoring program, the arc current waveform showed the same characteristic in all measurement points of all load. But the arc voltage waveform was different in each measurement point. When arc occurred, the THD of current value increased above 20%. The results of this study will be effectively used in developing the preventive system of electric fire by series arc.

인코더, 디코오더를 가지는 다치 연산기 설계 (Design of a Multi-Valued Arithmetic Processor with Encoder and Decoder)

  • 박진우;양대영;송홍복
    • 한국정보통신학회논문지
    • /
    • 제2권1호
    • /
    • pp.147-156
    • /
    • 1998
  • 본 논문에서는 다치 논리를 이용한 연산기를 설계하였다. 다치 논리를 구현하기 위해서 전류모드 CMOS 회로를 이용하였으며 이진 전압모드 신호를 다치 전류모드 신호로 바꾸어 주는 인코더와 연산 결과인 다치 전류모드 신호를 이진 전압모드 신호로 바꾸어 주는 디코오더를 사용하여 기존의 이진 시스템에 적용할 수 있도록 하였으며, 승산기 설계시 부분곱 수를 줄이기 위하여 기존의 Booth 알고리즘을 확장한 4진 SD수 부분곱 발생 알고리즘을 사용하였다. 제안된 회로는 SPICE 시뮬레이션 및 FPGA Chip을 이용한 하드웨어 에뮬레이션으로 그 유효함을 확인하였다

  • PDF