• Title/Summary/Keyword: Current Wave

Search Result 1,954, Processing Time 0.031 seconds

A Study on the Torque Ripple Reduction on Brushless DC Motor (브러시리스 직류 전동기의 토크리플 저감에 관한 연구)

  • Ryoo, Si-Yeong
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.2
    • /
    • pp.7-14
    • /
    • 2005
  • This paper presents a method to reduce torque ripple of brushless DC motor by compensating phase delay due to winding inductance. For considering torque ripple comes from the phase winding inductance, torque equation of one phase is derived as Fourier series that is function of the delay. From the equation, also the resultant equation that the current delay is compensated is derived. It is validated that the compensated torque has a form of Fourier series for rectangular wave that is ideal torque, and torque ripple is reduced, consequently. Experimental method for the compensation is realized by replacing switching pattern of inverter by pattern of compensated rotor position. The effectiveness of the proposed method to reduce torque ripple has been demonstrated by the simulation and experimental results using 3 phase 4 pole brushless DC moor.

Reforming Method and Proposal for the Technical Regulation of Extremely Electric Filed Strength Radio Equipment below 135kHz (135kHz 이하 미약 전계강도 무선기기 기술기준 개선 방안 및 제안)

  • Kim, Sun-Youb;Jeoung, Chan-Gwoun;Kang, Young-Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.1
    • /
    • pp.9-15
    • /
    • 2010
  • This paper analyzed the problems of the Korean output regulation in the relevant band through an analytic comparison of the current trend of each country and their standard values concerning electric field strength (technical standard) of weak wireless stations with less than 135kHz. In connection with the standard value of electric field strength of each country, which has been proposed in the registration of the appropriate electric wave, the paper aims to propose the standard value of electric field strength that could actually be introduced for suitable unauthorized wireless devices (weak wireless devices) in Korea. Provided that the Korean standard may be upgraded based on the tolerances of electric field strength proposed m this paper, this is expected to be committed to the distribution and advancement of weak wireless devices; and further it is anticipated to be prepared with competitiveness not only in the Korean communications market, but also in the international communications market.

Improvement of AlGaAs/GaAs Quantum Well Laser Diodes by Thermal Annealing (AlGaAs/GaAs 레이저 다이오우드의 열처리에 의한 개선에 관한 연구)

  • Jung, Hyon-Pil;Kenzhou Xie;Wie, Chu-Ryang;Lee, Yun-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.3
    • /
    • pp.449-455
    • /
    • 1993
  • In order to investigate the improvements of relatively poor characteristics of short wave length AlGaAs/GaAs laser diodes which are useful as a light source for short distance communication systems, the low temperature $(<680^{\circ}C)$ grown AlGaAs/GaAs GRINSCH-QW laser diodes by molecular beam epitaxy have been studied by photoluminescence as a function of rapid thermal annealing (RTA) temperature. It is shown that guantum well photoluminescence intensity increased substantially by a factor of 10 after RAT at $950^{\circ}C$ for 10 sec. This is related to the reduction of non-radiative recombination in the guantum well region. The threshold current of annealed laser diode is reduced by a factor, of 4, confirming the improvement of laser diode quality by rapid thermal annealing.

  • PDF

Analysis of the Electromagnetic Scattering by Conducting Strip Gratings with 2 Dielectric Layers On a Grounded Plane (접지평면위에 2개의 유전체층을 가지는 저항띠 격자구조에서의 전자파산란 해석)

  • 윤의중
    • The Journal of Information Technology
    • /
    • v.4 no.3
    • /
    • pp.77-86
    • /
    • 2001
  • In this paper, Electromagnetic scattering problem by a resistive strip grating with 2 dielectric layers on a ground plane according as resistivity of resistive strip, relative permittivity and thickness of dielectric layers, and incident angles of a electric wave is analyzed by applying the PMM (Point Matching Method) known as a numerical procedure. The scattered electromagnetic fields are expanded in a series of floquet mode functions. The boundary conditions are applied to obtain the unknown field coefficients and the resistive boundary condition is used for the relationship between the tangential electric field and the electric current density on the strip. According as the relative permittivity and the thickness of layers are increased, the values of the geometrically normalized reflected power have a high value and the values of strip width are moved toward a high value going from left to right. When the resistivity of this paper has a value of zero, the numerical results of the geometrically normalized reflected power show in good agreement with those by the PMM of existing paper. Then, the most energys of the sharp variation point in minimum values of the geometrically normalized reflected power are scattered in direction of the other angles except incident angle.

  • PDF

Design of Access Fixture for a Large Vacuum Chamber (대형 열진공챔버용 내부 위성체 근접 치구 설계)

  • Lee, Sang-Hoon;Cho, Hyok-Jin;Seo, Hee-Jun;Moon, Guee-Won
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.8 no.1
    • /
    • pp.55-61
    • /
    • 2010
  • Thermal vacuum test should be carried out to verify the performance of the S/C on the ground under the simulated space environment. KARI already completed the construction of a Large Thermal Vacuum Chamber(LTVC) with 8 m of diameter and 10 m of length dimension. LTVC is for the purpose of performing the orbital environment test for large Space Craft(S/C). Inside LTVC, S/C is much smaller than LTVC. For the function test of S/C during the thermal vacuum test, the S/C has to be connected to Electrical Ground Support Equipment(EGSE) which includes several cable and RF wave guide inside LTVC. Also, MLI should be installed on S/C before the test. But it is very difficult to access the S/C inside big LTVC. To solve the accessibility to the S/C inside LTVC, KARI designed an access fixture. This fixture provides easy access to the any S/C thus can help safe installation and saving time for the related work inside LTVC. This paper describes whole process for the design of the access fixture.

  • PDF

Survey for Needs of Bio-Signal Devices for the Diagnosis, Assessment, or Analysis of Neurocognitive Disorder in Korean Society of Oriental Neuropsychiatry (인지 장애 진단·평가·분석을 위한 생체신호 장비 개발에 대한 수요조사: 한방신경정신과학회 회원들을 대상으로)

  • Choi, Yujin;Kim, Ji Hye;Kim, Kahye;Kim, Jaeuk
    • Journal of Oriental Neuropsychiatry
    • /
    • v.31 no.2
    • /
    • pp.89-99
    • /
    • 2020
  • Objectives: The purpose of this study was to identify the needs of bio-signal devices for the diagnosis, assessment, and analysis of neurocognitive disorder in Korean medicine (KM) hospitals and clinics. Methods: A questionnaire was developed to survey the current status of medical device use, and diagnosis and interventions for patients with cognitive disorders in KM hospitals and clinics. November 11~December 2, 2019, 114 responses (71.9% completed) were collected by internet-based questionnaires from the members of the Korean society of Oriental Neuropsychiatry. Results: The clinical requests were in the descending order of hematology analyzer, ultrasound imaging system, and electroencephalography among the 15 most commonly used devices of which research would support for their clinical usability. The biosignal-based devices showed the highest research demands for patients with mild cognitive impairment rather than more severe stages of cognitive impairment. Prevention rather than diagnosis, or several treatment regimens was the strongest clinical area of the KM for patients with neurodegenerative cognitive impairment. Many responded that five to 10 minutes of test duration and 20,000 won to 30,000 won of cost would be appropriated for a new device to be developed. Conclusions: There were strong demands for the development of bio-signal devices for neurocognitive disorders among the KM doctors. Specifically, it showed high needs for the technology that can be used in the prevention area of cognitive disorders. Additionally, new medical devices to assess cognitive functions and to obtain KM pattern-related information were the high needs.

Irradiation of Intense Characteristic X-rays from Weakly Ionized Linear Plasma

  • Sato, Eiichi;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.396-399
    • /
    • 2002
  • Intense quasi-monochromatic x-ray irradiation from the linear plasma target is described. The plasma x-ray generator employs a high-voltage power supply, a low-impedance coaxial transmission line, a high-voltage condenser with a capacity of about 200 nF, a turbo-molecular pump, a thyristor pulse generator as a trigger device, and a flash x-ray tube. The high-voltage main condenser is charged up to 55 kV by the power supply, and the electric charges in the condenser are discharged to the tube after triggering the cathode electrode. The x-ray tube is of a demountable triode that is connected to the turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to the molybdenum target by the electric field in the tube, the weakly ionized plasma, which consists of metal ions and electrons, forms by the target evaporating. In the present work, the peak tube voltage was almost equal to the initial charging voltage of the main condenser, and the peak current was about 20 kA with a charging voltage of 55 kV. When the charging voltage was increased, the linear plasma x-ray source grew, and the characteristic x-ray intensities of K-series lines increased. The quite sharp lines such as hard x-ray lasers were clearly observed. The quasi-monochromatic radiography was performed by a new film-less computed radiography system.

  • PDF

Current Status of Ocean Satellite Remote Sensing Data and Its Distribution (해양의 인공위성 자료 현황과 배포 소개)

  • Yang, Chan-Su
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.11a
    • /
    • pp.51-55
    • /
    • 2007
  • As for satellite programs, the multipurpose satellite 1(KOMPSAT-1) was successfully launched on Dec. 21, 1999 and operated for three years. It is still properly operated even though its life cycle was ended. The development of KOMPSAT-2 (Korea Multipurpose Satellite-2) is near completion and the development of KOMPSAT-3, KOMPSAT-5 and COMS (Communication, Ocean, Meterological Satellite) are proceeding swiftly. In KORDI(Korea Ocean Research and Development Institute), the KOSC (Korea Ocean Satellite Center) construction project is being prepared for acquisition, processing and distribution of sensor data via L-band from GOCI(Geostationary Ocean Color Imager) instrument which is loaded on COMS(Communication, Ocean and Meteorological Satellite); it will be launched in 2000. Ansan(the headquarter of KORDD has been selected for the location of KOSC between 5 proposed sites, because it has the best condition to receive radio wave. The data acquisition system is classified antenna and RF. Antenna is designed to be ${\emptyset}$ 9m cassegrain antenna which has 19.35 $G/T(dB/^{\circ}K)$ at 1.67GHz, RF module, is divided into LNA(Low noise amplifier) and down converter, those are designed to send only horizontal polarization to modem The existing building is re-designed and classified for the KOSC operation concept; computing room, board of electricity, data processing room, operation room Hardware and network facilities have been designed to adapt for efficiency of each functions. The distribution system which is one of the most important systems will be constructed mainly on the internet, and it is also being considered constructing outer data distribution system as a web hosting service for to offering received data to user under an hour.

  • PDF

Cathodic Reduction of Dichromate Ion (중크롬산이온의 음극 환원반응)

  • Lee Ju-Seong
    • Journal of the Korean Chemical Society
    • /
    • v.21 no.4
    • /
    • pp.276-283
    • /
    • 1977
  • Reduction of dichromate at a platinum cathode in acid solution was studied by cyclic voltammetry and controlled potential electrolysis. Cathodic polarization curve consisted of three waves in unbuffered solution of potassium dichromate having initial pH ranges 1.5∼4.0, with sodium sulfate as the supporting electrolyte. Relative heights of the first and the second waves were, respectively, a function of chromium (Ⅵ) concentration and activity of hydrogen ion, but that of the third wave was not proportional to both of them. The current of the first two peaks were proportional to the sweep rate of potential (${\nu}$), while that of the last peak vs. ${\nu}^{1/2}$ was linear at the sweep rate of less than 50mV/sec. By the controlled potential electrolysis, the reduction of chromium (Ⅵ) was almost completely suppressed at potentials more negative than the last peak and at initial pH's above ca. 2.3 of unbuffered solution. Therefore, these peaks represented, respectively, $Cr_2O_7^{2-}{\to}Cr^{3+},\;2H^+{\to}H_2$ and the formation of a cathodic film.

  • PDF

Electrochemical Reduction on the -S-N= Bond of N-Tert-butylbenzothiazole-2-sulfenamide (N-Tert-butylbenzothiazole-2-sulfenamide의-S-N = 결합에 대한 전기화학적 환원)

  • Kim, Hae-Jin;Jung, Keun-Ho;Choi, Qw-Won;Kim, Il-Kwang;Leem, Sun-Young
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.6
    • /
    • pp.673-679
    • /
    • 1991
  • The electrochemical reduction of N-tert-butylbenzothiazole-2-sulfenamide (TBBS; vulcanization accelerator) was investigated by direct current, differential pulse polarography, cyclic voltammetry and controlled potential coulometry. The electrode reduction of TBBS proceeded E-C-E-C reaction mechanism by four electrons transfer at irreversible one wave (-2.31 volts vs. Ag/0.1M AgN$O_3$ in AN). As the results of controlled potential electrolysis, mercaptobenzothiazole (MBT), benzothiazole disulfide (MBT dimer) and extricated sulfur were products which followed by cleavage of the sulfenamide (-S-N=) bond. Upon the basis of products analysis and polarogram interpretation with pH variable, electrochemical reaction mechanism was suggested.

  • PDF