• 제목/요약/키워드: Current Transducer

검색결과 90건 처리시간 0.032초

A new ultrasonic power generator using instantaneous current resultant control-based inverter and its control system

  • Kim, Dong-Hee;Kim, Young-Seok;Yoo, Dong-Wook;Kim, Yo-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.631-636
    • /
    • 1987
  • The design of ultrasonic transducer energy processing systems requires highly reliable command featuring mechanical frequency tracking and constant velocity control of the ultrasonic transducer with an acoustic load. This paper presents a new conceptional instantaneous current resultant control base high-frequency inverter using self turn-off devices driving an electrostrictive ultrasonic transducer system and its optimum control technique, which is implemented by feed-back of the ultrasonic transducer applied voltage and instantaneous velocity of the transducer vibrating system through a Phase-Locked-Loop control scheme. The feedback voltage corresponding to instantaneous velocity is averaged over a half-period with respect to constant amplitude/constant velocity control strategy. Described are the theory of this signal detection technique and the experimental set-up.

  • PDF

Fiber Fabry-Perot type Optical Current Transducer with Frequency Ramped Signal Processing Scheme

  • Park, Youn-Gil;Seo, Wan-Seok;Lee, Chung-E.;Taylor, Henry-F.
    • Journal of the Optical Society of Korea
    • /
    • 제2권2호
    • /
    • pp.74-79
    • /
    • 1998
  • The use of a fiber Fabry-Perot interferometer (FFPI) as an optical current transducer is demonstrated. A conventional inductive pickup coil converts the time-varying current I(t) being measured to a voltage waveform V(t) applied across a piezeolectric strip to which the FFPI is bonded. The strip experiences a longitudinal expansion and contraction, resulting in an optical phase shift ${\phi}(t)$ in the fiber proportional to V(t). This phase shift is measured using a frequency-modulated semiconductor light source, photodiodes to monitor the reflected light from the FFPI and the laser power, and a digital signal processor. Calibration routines compute V(t) and I(t) from the measured phase shift at a l KHz rate. Response to 60 Hz ac over the design range 0-1300A rms is characterized Transient response of the FFPI transducer is also measured.

연속된 배관의 결함 검출을 위한 개폐식 와전류 탐촉자 개발 (Development of Open-Connect Type Eddy Current Transducers for the Detection of Surface Flaws in Continuous Pipeline)

  • 김영주;안봉영;이승석
    • 비파괴검사학회지
    • /
    • 제22권2호
    • /
    • pp.187-192
    • /
    • 2002
  • 서로 연결되어 있는 강관의 결함을 검사할 수 있도록 하기 위한 개폐식 탐촉자를 제작하였다. 본 탐촉자는 기존의 외삽형 와전류 탐촉자로서는 탐상이 불가능한 설치 가동중인 튜브류의 검사를 위한 것이다. 리본 케이블과 커넥터로 구성된 여기 코일은 접합/단락이 가능하게 하였으며 감지 코일은 튜브 외벽 근처에 원주 방향으로 어레이 형태로 배치하였는데 여기 코일로부터 튜브 직경의 약 1.5배정도 떨어진 위치이다. 제작된 탐촉자를 강관에 적용한 결과, 감도나 결함 크기 구분 등의 성능은 자기 포화형 탐촉자에 미치지 못하나 비교적 큰 결함의 발견이나 위치 파악 등에는 적용 가능한 것으로 나타났다. 크랙 형태의 표면 결함의 경우 두께의 19% 이상의 결함을 찾을 수 있었다.

교류초퍼에서 단락사고 방지를 위한 스위칭 신호 패턴 (Switching Signal Patterns to Prevent Short Circuit of AC Choppers)

  • 장도현;연재을
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권9호
    • /
    • pp.445-452
    • /
    • 2001
  • Two switching signal patterns are proposed to prevent short circuit of PWM ac choppers. The voltage detection method and the current detection method are proposed to execute two switching signal patterns. In the voltage detection method, the dead-time has to be inserted to the switching signals after polarity of input voltage is checked by voltage transducer at input side. In the current detection method, the direction of load current is checked by current transducer at output side, and the dead-time delay is not considered. Controlling circuit built by current detection method is simple because the dead-time delay is considered. The experimental results are presented to prevent short circuit of ac chopper safely.

  • PDF

멀티 콘센트용 변류기 및 과전류 검출 회로 설계 (Design of a Current Transducer and Over-Current Fault Detection Circuit for Power Strip Applications)

  • 김용재;김민석;박규상;김재홍
    • 한국전자통신학회논문지
    • /
    • 제10권8호
    • /
    • pp.921-926
    • /
    • 2015
  • 멀티 콘센트의 과전류로 인한 과열을 방지하기 위한 보호방식으로는 주로 금속바이메탈 방식, 스위칭회로 방식, 마이크로컨트롤러(MCU)를 이용한 과전류 정밀제어 방식 등이 사용되어 오고 있다. 하지만 이러한 방식들은 보호회로가 과전류가 흐르는 전선에 병렬접속 함으로써 2차 화재의 위험이 있을 수 있으며 입력전압의 비선형 왜곡에 취약한 단점을 가지고 있다. 또한 기존의 방식들은 제품의 단가가 비교적 크게 올라가므로 충분한 시장성을 확보하기가 쉽지 않다. 본 논문에서는 이러한 문제를 해결하고자 과전류가 흐르는 전선에 비접촉식 관통형 변류기를 설계하고 변류기의 2차 유도전류를 이용하여 과전류를 감지하여 사용자가 과전류 상황을 인지할 수 있도록 LED 및 부저 회로를 통하여 시각 및 청각적 신호를 전달하는 기능을 구현한다. 실험 결과들로부터 제안된 회로는 매우 경제적이고 간단하면서도 안정적으로 동작함을 확인 할 수 있다.

직선배열 진동자에 의한 도풀러 로그의 지향특성 개선에 관한 연구 (Improvement of the Directivity of a Doppler Log Using Linear Transducer Array)

  • 신형일;정세모
    • 한국항해학회지
    • /
    • 제5권2호
    • /
    • pp.1-39
    • /
    • 1981
  • A doppler log is the typical device which can measure the ship's speed over the ground directly, by means of doppler effect of the underwater ultrasonic wave, which involves the error due to the sea bottom inclination, the trim and the incorrect transducer installation etc. The present doppler log adopts a single transducer, faced in the direction of themain beam, and therefore it is unable to correct the beam direction to eliminate the above mentioned error. Moreover, the frequencyis also limitted in a comparatively high range for getting a sharp beam with single transducer, and the speed over the ground can not be detectable at the deep sea, for an instance, over 200 meters. This paper describes a theoretical consideration for the doppler log error and an analysis by a computer on the observed speed data by a full size model ship. The result is verified that the most of doppler log error is caused by the ultrasonic beam angle of transducer. To eliminate the doppler log error due to the incorrect transducer installation and also to sharpen the beam for lower frequency range to expand measurable sea depth, this paper proposes a method of controlling the directivity adopting a linear transducer array and of controlling the directivity by the control of exciting current, and investigates by the computer simulation and make experiment with magnetostrictive ferrite transducer of 28, 50 and 75KHz. The experimental results are shown well coincide with the measured ones, and they are revealed that in case where the transducer interval is greater than 1 wavelength, the effective control of the beam direction is hardly performed with keeping adequate beam width and side lobe level. It is concluded that 6-elements array with inter element space of a half wavelength can make comparatively sharp beam and low side lobe level. The results obtained here will contribute very much to the improvement of the performance of doppler log.

  • PDF

반도체 마이크로 머시닝 기술을 이용한 전자기형 진동 트랜스듀서의 실리콘 탄성체 구현 (Fabrication of Silicon Elastic Body of Electromagnetic Type Vibration Transducer by Using Micromachining Technique)

  • 이기찬;이세규;박세광;권기진;조진호;이상흔
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1142-1144
    • /
    • 1999
  • A 4-beam cross type silicon elastic body was fabricated for the electromagnetic type vibration micro transducer. To improve energy transfer efficiency, the structure and size of vibration transducer were optimized by the FEA simulation package. Experimental results of the fabricated transducer shows $0.5{\sim}8$ dyne of vibration force at the condition of $1{\sim}4$ mA of current source $100{\sim}7000$ Hz of frequency band width. These results presented the useful applications for micro actuators and sensors.

  • PDF

초음파 수술기의 수술 효율성 향상을 위한 진동자 임피던스 측정에 따른 조직 분류 연구 (Classification of Organs Using Impedance of Ultrasonic Surgical Knife to improve Surgical Efficiency)

  • 김홍래;김성천;김광기;김영우
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권3호
    • /
    • pp.141-147
    • /
    • 2013
  • Ultrasonic shears is currently in wide use as an energy device for minimal invasive surgery. There is an advantage of minimizing the carbonization behavior of the tissue due to the vibrational energy transfer system of the transducer by applying a piezoelectric ceramic. However, the vibrational energy transfer system has a pitfall in energy consumption. When the movement of the forceps is interrupted by the tissue, the horn which transfers the vibrational energy of the transducer will be affected. A study was performed to recognize different tissues by measuring the impedance of the transducer of the ultrasonic shears in order to find the factor of energy consumption according to the tissue. In the first stage of the study, the voltage and current of the transducer connecting portion were measured, along with the phase changes. Subsequently, in the second stage, the impedance of the transducer was directly measured. In the final stage, using the handpiece, we grasped the tissue and observed the impedance differences appeared in the transducer To verify the proposed tissue distinguishing method, we used the handpiece to apply a force between 5N and 10N to pork while increasing the value of the impedance of the transducer from 400 ${\Omega}$.. It was found that fat and skin tissue, tendon, liver and protein all have different impedance values of 420 ${\Omega}$, 490 ${\Omega}$, 530 ${\Omega}$, and 580 ${\Omega}$, respectively. Thus, the impedance value can be used to distinguish the type of tissues grasped by the forceps. In the future study, this relationship will be used to improve the energy efficiency of ultrasonic shears.

포화자성코어를 이용한 직류전류측정 트랜스듀서 (DC Current Transducer Using Saturable Magnetic Cores)

  • 박영태;정재갑;강전홍;유권상;유광민
    • 한국자기학회지
    • /
    • 제14권4호
    • /
    • pp.138-142
    • /
    • 2004
  • 본 연구는 누설전류와 같은 직류 저 전류를 측정하기 위한 센서 개발에 관한 것이다. 2개의 동일한 링 형태의 자성체 코어를 이용하여 전류센서를 개발하였으며 센서에 대한 특성과 불확도에 대하여 기술하였다. 이 트랜스듀서는 변성기형의 센서, 피크검출기, 기준저주파발진기 그리고 고조파를 함유한 센서의 출력을 측정할 수 있는 정밀 측정회로들로 구성되며 DC 2A까지 측정할 수 있다. 분해능과 감도는 0.㎃. 10㎷/㎃로. 각각 평가되었다.

GIS용 광CT의 전기적 특성 (Electrical Characteristics of Optical Current Transducer on Gas Insulated Switchgear)

  • 이수웅;이성갑;노현지;안병립;원우식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.319-320
    • /
    • 2007
  • We researched basic study about electrical characteristics of Zinc Selenide (Faraday Cell), which is known for various temperature of good-performance, that applied measuring current or protecting instrument by Optical Current Transducer, on Gas Insulated Switchgear. Measuring System consists of VCSEL produced 850nm IR Laser, Pin Photo Diode made of GaAs surveyed as Optical Power Meter, and Optical Fibers specified Multi-mode. We observed optical output changes during measurement of currents increasing by 100[A] in range from 0[A] to 1,000[A] and set temperature condition increasing by $5[^{\circ}C]$ in a range from $30[^{\circ}C]\;to\;60[^{\circ}C]$.

  • PDF