• Title/Summary/Keyword: Current Transducer

Search Result 90, Processing Time 0.025 seconds

A new ultrasonic power generator using instantaneous current resultant control-based inverter and its control system

  • Kim, Dong-Hee;Kim, Young-Seok;Yoo, Dong-Wook;Kim, Yo-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.631-636
    • /
    • 1987
  • The design of ultrasonic transducer energy processing systems requires highly reliable command featuring mechanical frequency tracking and constant velocity control of the ultrasonic transducer with an acoustic load. This paper presents a new conceptional instantaneous current resultant control base high-frequency inverter using self turn-off devices driving an electrostrictive ultrasonic transducer system and its optimum control technique, which is implemented by feed-back of the ultrasonic transducer applied voltage and instantaneous velocity of the transducer vibrating system through a Phase-Locked-Loop control scheme. The feedback voltage corresponding to instantaneous velocity is averaged over a half-period with respect to constant amplitude/constant velocity control strategy. Described are the theory of this signal detection technique and the experimental set-up.

  • PDF

Fiber Fabry-Perot type Optical Current Transducer with Frequency Ramped Signal Processing Scheme

  • Park, Youn-Gil;Seo, Wan-Seok;Lee, Chung-E.;Taylor, Henry-F.
    • Journal of the Optical Society of Korea
    • /
    • v.2 no.2
    • /
    • pp.74-79
    • /
    • 1998
  • The use of a fiber Fabry-Perot interferometer (FFPI) as an optical current transducer is demonstrated. A conventional inductive pickup coil converts the time-varying current I(t) being measured to a voltage waveform V(t) applied across a piezeolectric strip to which the FFPI is bonded. The strip experiences a longitudinal expansion and contraction, resulting in an optical phase shift ${\phi}(t)$ in the fiber proportional to V(t). This phase shift is measured using a frequency-modulated semiconductor light source, photodiodes to monitor the reflected light from the FFPI and the laser power, and a digital signal processor. Calibration routines compute V(t) and I(t) from the measured phase shift at a l KHz rate. Response to 60 Hz ac over the design range 0-1300A rms is characterized Transient response of the FFPI transducer is also measured.

Development of Open-Connect Type Eddy Current Transducers for the Detection of Surface Flaws in Continuous Pipeline (연속된 배관의 결함 검출을 위한 개폐식 와전류 탐촉자 개발)

  • Kim, Young-Joo;Ahn, Bong-Young;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.187-192
    • /
    • 2002
  • The open-connect type eddy current transducer for the flaw detection in continuously connected pipelines was developed. This eddy current transducer is for the on-line inspection of the tubes in industries, to which commercial encircling probes are not applicable. The excitation coil that consists of a ribbon type cable and a flat connector can be opened and closed on purpose. The sensing coils of this transducer are circumferentially arrayed near the outside of the tube wall but axially displaced from the exciter by about one and half tube diameter. In application to steel tubes, and the performance of this transducer was evaluated as a little behind those of magnetic saturation type in signal to noise ratio and flaw size decision, but usable to detect or to locate large size flaws in steel tubes. Surface cracks deeper than 19% of the tube thickness could be detected with good signal to noise ratio.

Switching Signal Patterns to Prevent Short Circuit of AC Choppers (교류초퍼에서 단락사고 방지를 위한 스위칭 신호 패턴)

  • Jang, Do-Hyeon;Yeon, Jae-Eul
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.9
    • /
    • pp.445-452
    • /
    • 2001
  • Two switching signal patterns are proposed to prevent short circuit of PWM ac choppers. The voltage detection method and the current detection method are proposed to execute two switching signal patterns. In the voltage detection method, the dead-time has to be inserted to the switching signals after polarity of input voltage is checked by voltage transducer at input side. In the current detection method, the direction of load current is checked by current transducer at output side, and the dead-time delay is not considered. Controlling circuit built by current detection method is simple because the dead-time delay is considered. The experimental results are presented to prevent short circuit of ac chopper safely.

  • PDF

Design of a Current Transducer and Over-Current Fault Detection Circuit for Power Strip Applications (멀티 콘센트용 변류기 및 과전류 검출 회로 설계)

  • Kim, Yong-Jae;Kim, Min-Seok;Park, Gyu-Sang;Kim, Jae-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.8
    • /
    • pp.921-926
    • /
    • 2015
  • For the over-heat protection purpose in power strip devices, over-current detection/protection circuits, such as bimetal, switching circuit, and microprocessor-based relay circuit, have been widely setup in high-end products. Most of these circuits are connected to the power line in parallel and, thus, they are sensitive to the line voltage and current distortion. Moreover, these protection circuits are often costly and, therefore, it is hard to meet the commercial requirements. A low-cost over-current detection circuit with the contactless current transducer is designed and tested in this paper. The detection circuit is galvanically isolated from the power line and, thus, less sensitive to the line voltage distortion. The experimental results show that the proposed circuit accurately operates despite of its simple structure and low-cost electronic parts.

Improvement of the Directivity of a Doppler Log Using Linear Transducer Array (직선배열 진동자에 의한 도풀러 로그의 지향특성 개선에 관한 연구)

  • 신형일;정세모
    • Journal of the Korean Institute of Navigation
    • /
    • v.5 no.2
    • /
    • pp.1-39
    • /
    • 1981
  • A doppler log is the typical device which can measure the ship's speed over the ground directly, by means of doppler effect of the underwater ultrasonic wave, which involves the error due to the sea bottom inclination, the trim and the incorrect transducer installation etc. The present doppler log adopts a single transducer, faced in the direction of themain beam, and therefore it is unable to correct the beam direction to eliminate the above mentioned error. Moreover, the frequencyis also limitted in a comparatively high range for getting a sharp beam with single transducer, and the speed over the ground can not be detectable at the deep sea, for an instance, over 200 meters. This paper describes a theoretical consideration for the doppler log error and an analysis by a computer on the observed speed data by a full size model ship. The result is verified that the most of doppler log error is caused by the ultrasonic beam angle of transducer. To eliminate the doppler log error due to the incorrect transducer installation and also to sharpen the beam for lower frequency range to expand measurable sea depth, this paper proposes a method of controlling the directivity adopting a linear transducer array and of controlling the directivity by the control of exciting current, and investigates by the computer simulation and make experiment with magnetostrictive ferrite transducer of 28, 50 and 75KHz. The experimental results are shown well coincide with the measured ones, and they are revealed that in case where the transducer interval is greater than 1 wavelength, the effective control of the beam direction is hardly performed with keeping adequate beam width and side lobe level. It is concluded that 6-elements array with inter element space of a half wavelength can make comparatively sharp beam and low side lobe level. The results obtained here will contribute very much to the improvement of the performance of doppler log.

  • PDF

Fabrication of Silicon Elastic Body of Electromagnetic Type Vibration Transducer by Using Micromachining Technique (반도체 마이크로 머시닝 기술을 이용한 전자기형 진동 트랜스듀서의 실리콘 탄성체 구현)

  • Lee, K.C.;Lee, S.K.;Park, S.K.;Kwon, K.J.;Cho, J.H.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1142-1144
    • /
    • 1999
  • A 4-beam cross type silicon elastic body was fabricated for the electromagnetic type vibration micro transducer. To improve energy transfer efficiency, the structure and size of vibration transducer were optimized by the FEA simulation package. Experimental results of the fabricated transducer shows $0.5{\sim}8$ dyne of vibration force at the condition of $1{\sim}4$ mA of current source $100{\sim}7000$ Hz of frequency band width. These results presented the useful applications for micro actuators and sensors.

  • PDF

Classification of Organs Using Impedance of Ultrasonic Surgical Knife to improve Surgical Efficiency (초음파 수술기의 수술 효율성 향상을 위한 진동자 임피던스 측정에 따른 조직 분류 연구)

  • Kim, Hong Rae;Kim, Sung Chun;Kim, Kwang Gi;Kim, Young-Woo
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.141-147
    • /
    • 2013
  • Ultrasonic shears is currently in wide use as an energy device for minimal invasive surgery. There is an advantage of minimizing the carbonization behavior of the tissue due to the vibrational energy transfer system of the transducer by applying a piezoelectric ceramic. However, the vibrational energy transfer system has a pitfall in energy consumption. When the movement of the forceps is interrupted by the tissue, the horn which transfers the vibrational energy of the transducer will be affected. A study was performed to recognize different tissues by measuring the impedance of the transducer of the ultrasonic shears in order to find the factor of energy consumption according to the tissue. In the first stage of the study, the voltage and current of the transducer connecting portion were measured, along with the phase changes. Subsequently, in the second stage, the impedance of the transducer was directly measured. In the final stage, using the handpiece, we grasped the tissue and observed the impedance differences appeared in the transducer To verify the proposed tissue distinguishing method, we used the handpiece to apply a force between 5N and 10N to pork while increasing the value of the impedance of the transducer from 400 ${\Omega}$.. It was found that fat and skin tissue, tendon, liver and protein all have different impedance values of 420 ${\Omega}$, 490 ${\Omega}$, 530 ${\Omega}$, and 580 ${\Omega}$, respectively. Thus, the impedance value can be used to distinguish the type of tissues grasped by the forceps. In the future study, this relationship will be used to improve the energy efficiency of ultrasonic shears.

DC Current Transducer Using Saturable Magnetic Cores (포화자성코어를 이용한 직류전류측정 트랜스듀서)

  • Park, Young-Tae;Jung, Jae-Kap;Gang, Jeon-Hong;Ryu, Kwon-Sang;Yu, Kwang-Min
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.4
    • /
    • pp.138-142
    • /
    • 2004
  • Uncertainty and characteristics of the developed current sensor by means of two identically wound magnetic cores forming a ring like for measurement of a low DC current such as leakage current was described in this paper. This transducer consists of a sensor type of a current transformer, peak value detectors, a reference alternating low frequency voltage oscillator, precision measuring circuits to measure the output signals of sensor with harmonics, and can be measured up to 2 A at DC current. The resolution and sensitivity of the sensor were 0.1㎃ and 10㎷/㎃, respectively.

Electrical Characteristics of Optical Current Transducer on Gas Insulated Switchgear (GIS용 광CT의 전기적 특성)

  • Lee, Su-Woong;Lee, Sung-Gap;Noh, Hyeon-Ji;Ahn, Byeong-Rib;Won, Woo-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.319-320
    • /
    • 2007
  • We researched basic study about electrical characteristics of Zinc Selenide (Faraday Cell), which is known for various temperature of good-performance, that applied measuring current or protecting instrument by Optical Current Transducer, on Gas Insulated Switchgear. Measuring System consists of VCSEL produced 850nm IR Laser, Pin Photo Diode made of GaAs surveyed as Optical Power Meter, and Optical Fibers specified Multi-mode. We observed optical output changes during measurement of currents increasing by 100[A] in range from 0[A] to 1,000[A] and set temperature condition increasing by $5[^{\circ}C]$ in a range from $30[^{\circ}C]\;to\;60[^{\circ}C]$.

  • PDF