• Title/Summary/Keyword: Current Rate of Change

Search Result 625, Processing Time 0.033 seconds

Analysis and a Compensation Method for Torque Ripple caused by Position Error in Switched Reluctance Motor Position Sensorless Control (스위치드 릴럭턴스 전동기의 위치 센서리스 제어시 위치오차에 의해 발생하는 토크리플 해석과 그 보상 방법)

  • Oh, Ju-Hwan;Kwon, Byung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.806-807
    • /
    • 2011
  • This paper presents a new sensorless controller used with both the classical sliding mode observer(SMO) and the rate of current change in order to a reduced torque ripple for switched reluctance motor (SRM) sensorless drives. The new sensorless scheme consists of a sliding mode observer (SMO)-based position sensorless approach for high speeds along with a low-resolution discrete the rate of current change for low speeds and standstill. The new position estimation resets between the SMO and the low-resolution of current change according to the speed sign and the position error difference between the SMO and the low-resolution rate of current change. The simulation results show the robustness of this new high performance sensorless control approach with the hybrid sensorless control topology.

  • PDF

Initial Rotor Position Detection of a Toroidal SRM Using the Rate of Change of Current (전류변화율을 이용한 토로이달 SRM의 초기위치 경출 방법)

  • Yang Hyong-Yeol;Lim Young-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.1
    • /
    • pp.26-32
    • /
    • 2005
  • Rotor position information is essential in the operation of the switched reluctance motor(SRM) drive for generation the phase current switching signals. When an incremental encoder is used as a rotor position sensor, the initial rotor position can not be detected. Some sensorless rotor position estimation methods also have the same problem. In these systems, to initially align the rotor, the forced alignment method has a delay and reverse rotation before the motor can start. Therefore it can not be acceptable for unidirectional drive systems. So the forced alignment method is not desirable in all drive systems and the research on the SRM drives should be directed to a system without rotor alignment. In this paper, a new detection method of initial rotor position using the rate of change of current is suggested. Firstly, di/dt versus θ/sub R/ reference table, which is the relation between the rate of change of current and rotor position, is generated and then the squared Euclidean distance method is used to estimate the rotor position based on the table. The simulated and experimental results are presented demonstrating the feasibility and accuracy of this method.

Impact of Climate Change on the Groundwater Recharge and Groundwater Level Variations in Pyoseon Watershed of Jeju Island, Korea (기후 변화에 따른 제주도 표선 유역의 함양률 및 수위변화 예측)

  • Shin, Esther;Koh, Eun-Hee;Ha, Kyoochul;Lee, Eunhee;Lee, Kang-Kun
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.6
    • /
    • pp.22-35
    • /
    • 2016
  • Global climate change could have an impact on hydrological process of a watershed and result in problems with future water supply by influencing the recharge process into the aquifer. This study aims to assess the change of groundwater recharge rate by climate change and to predict the sustainability of groundwater resource in Pyoseon watershed, Jeju Island. For the prediction, the groundwater recharge rate of the study area was estimated based on two future climate scenarios (RCP 4.5, RCP 8.5) by using the Soil Water Balance (SWB) computer code. The calculated groundwater recharge rate was used for groundwater flow simulation and the change of groundwater level according to the climate change was predicted using a numerical simulation program (FEFLOW 6.1). The average recharge rate from 2020 to 2100 was predicted to decrease by 10~12% compared to the current situation (1990~2015) while the evapotranspiration and the direct runoff rate would increase at both climate scenarios. The decrease in groundwater recharge rate due to the climate change results in the decline of groundwater level. In some monitoring wells, the predicted mean groundwater level at the year of the lowest water level was estimated to be lower by 60~70 m than the current situation. The model also predicted that temporal fluctuation of groundwater recharge, runoff and evapotranspiration would become more severe as a result of climate change, making the sustainable management of water resource more challenging in the future. Our study results demonstrate that the future availability of water resources highly depends on climate change. Thus, intensive studies on climate changes and water resources should be performed based on the sufficient data, advanced climate change scenarios, and improved modeling methodology.

A Study on the Reliability of Superconducting Fault Current Limiter and Adjacent Distribution Equipments (초전도한류기와 인근 배전설비의 신뢰도에 관한 연구)

  • Bae, In-Su;Kim, Sung-Yul;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2122-2127
    • /
    • 2009
  • This study presents the failure rate and repair rate of Superconducting Fault Current Limiter(SFCL) and adjacent distribution equipments. When the fault current penetrated SFCL, the supply of electric power to the customers can be partly continued. It is expected that SFCL makes to improve the reliability index of customers. Contrary to the expectations, the series connection between SFCL and distribution system could deteriorate the reliability index. To evaluate the reliability index in the distribution system including SFCL, the failure rate and repair rate of SFCL are required as well as that of distribution equipments. Also, the insertion of SFCL makes to change the failure rate and repair rate of adjacent equipments. This study proposes a method to calculate the failure rate and repair rate of a component combining SFCL and adjacent equipments.

Electrical Conduction of Polyethylene/Ethylene Vinyl Acetate Blend (Polyethylene/Ethylene Vinyl Acetate Blend의 전기전도현상)

  • Lee, Chang-R.;Kim, Ok;Lee, Mi-Kyung;Suh, Kwang-S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.115-119
    • /
    • 1995
  • Electrical conduction characteristics of Polyethylene/Ethylene vinyl acetate blends of varing vinyl acetate content(1% and 4%) were investigated at electric fields ranging from 10$\^$6/ to 10.$\^$8/ V/cm over the temperature range of 30 and 85$^{\circ}C$. It was obser-ved that the extent of current density was changed at the blends and the rate of change of current den-sity was slightly suppressed at high field range, but PE and EVA were not shown. The change of con-duction characteristics and a suppression in rate of change of current density were attributed to the VA content in PE.EVA blends.

  • PDF

Low Voltage CMOS LC VCO with Switched Self-Biasing

  • Min, Byung-Hun;Hyun, Seok-Bong;Yu, Hyun-Kyu
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.755-764
    • /
    • 2009
  • This paper presents a switched self-biasing and a tail current-shaping technique to suppress the 1/f noise from a tail current source in differential cross-coupled inductance-capacitance (LC) voltage-controlled oscillators (VCOs). The proposed LC VCO has an amplitude control characteristic due to the creation of negative feedback for the oscillation waveform amplitude. It is fabricated using a 0.13 ${\mu}m$ CMOS process. The measured phase noise is -117 dBc/Hz at a 1 MHz offset from a 4.85 GHz carrier frequency, while it draws 6.5 mA from a 0.6 V supply voltage. For frequency tuning, process variation, and temperature change, the amplitude change rate of the oscillation waveform in the proposed VCO is 2.1 to 3.2 times smaller than that of an existing VCO with a fixed bias. The measured amplitude change rate of the oscillation waveform for frequency tuning from 4.55 GHz to 5.04 GHz is 131 pV/Hz.

Study of changes in the kinetic parameters of corrosion on the macrocell current induced by the repair of reinforced concrete structures - Results of numerical simulation

  • Mostafa Haghtalab;Vahed Ghiasi;Aliakbar Shirzadi Javid
    • Computers and Concrete
    • /
    • v.32 no.3
    • /
    • pp.287-302
    • /
    • 2023
  • Corrosion of reinforcing bars in reinforced concrete structures due to chloride attack in environments containing chloride ions is one of the most important factors in the destruction of concrete structures. According to the abundant reports that the corrosion rate around the repair area has increased due to the macro-cell current known as the incipient anode, it is necessary to understand the effective parameters. The main objective of this paper is to investigate the effect of the kinetic parameters of corrosion including the cathodic Tafel slope, exchange current density, and equilibrium potential in repair materials on the total corrosion rate and maximum corrosion rate in the patch repair system. With the numerical simulation of the patch repair system and concerning the effect of parameters such as electromotive force (substrate concrete activity level), length of repair area, and resistivity of substrate and repair concrete, and with constant other parameters, the sensitivity of the macro-cell current caused by changes in the kinetic parameters of corrosion of the repairing materials has been investigated. The results show that the maximum effect on the macro-cell current values occurred with the change of cathodic Tafel slope, and the effect change of exchange current density and the equilibrium potential is almost the same. In the low repair extant and low resistivity of the repairing materials, with the increase in the electromotive force (degree of substrate concrete activity) of the patch repair system, the sensitivity of the total corrosion current reduces with the reduction in the cathode Tafel slope. The overall corrosion current will be very sensitive to changes in the kinetic parameters of corrosion. The change in the cathodic Tafel slope from 0.16 to 0.12 V/dec and in 300 mV the electromotive force will translate into an increase of 200% of the total corrosion current. While the percentage of this change in currency density and equilibrium potential is 53 and 43 percent, respectively. Moreover, by increasing the electro-motive force, the sensitivity of the total corrosion current decreases or becomes constant. The maximum corrosion does not change significantly based on the modification of the corrosion kinetic parameters and the modification will not affect the maximum corrosion in the repair system. Given that the macro-cell current in addition to the repair geometry is influenced by the sections of reactions of cathodic, anodic, and ohmic drop in repair and base concrete materials, in different parameters depending on the dominance of each section, the sensitivity of the total current and maximum corrosion in each scenario will be different.

A study on the color change switch and electrochemical doping of polythiophene (Polythiophene의 전기화학적 도핑과 변색 스위치에 관한 연구)

  • 구할본;김주승;김현철;김종욱
    • Electrical & Electronic Materials
    • /
    • v.9 no.2
    • /
    • pp.165-173
    • /
    • 1996
  • We prepared polythiophene and poly(3-methylthiophene) films, known as conducting polymer, by electrochemical method. Polythiophene and poly(3-methylthiophene) films were doped and undoped dopant for the studing the understanding of doping mechanism and possible application to the color change switch. We observed that the anodic, cathodic wave and absorption spectra were slightly changed during doping and undoping process in polythiophene. It shows that doping and undoping process were showed some difference by the appearance and disappearance of polaron and bi-polaron. In the relation of the peak of oxidative current density and potential sweep rate of cyclic voltammograms, the amount of dopant in polythiophene film was homogeneously increased at low scan rate. This also can be applied to the poly(3-methlythiophene).

  • PDF

Ramp-rate limitation of CIC(Cable-In-Conduit) superconducting magnet (관내권선(Cable-In-Conduit, CIC) 초전도 자석(Superconducting magnet)에서의 한계 자속 변화(ramp-rate limitation) 현상)

  • Jeong, Sang-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.37-40
    • /
    • 1996
  • Cable-In-Conduit Conductor(CICC) is widely accepted as an advanced superconductor configuration for large scale applications such as tokamak fusion reactors, MAGLEV (MAGnetic LEVitation), and SMES (Superconducting Magnetic Energy Storage). The stability of CICC cooled with supercritical helium can be very high if it is operated below a certain limiting current. This limiting current can be determined by Stekly type heat balance equation. The stability characteristic of CICC for AC operation is more complicated than that of DC because there are additional instability sources which are associated with local flux change. Ramp-rate limitation is a phenomenon discovered during US-DPC (United States-Demonstration Poloidal Coil) program, which showed apparent quench current degradation associated with high dB/dt. This paper describes recent experimental investigation results on the ramp-rate limitation and discusses current imbalance, induced current, current redistribution due to local quench of the strand in the cable.

  • PDF

A Study on the Control of Apartment House Design Factors considering Energy, Environment and Economical Efficiency (에너지, 환경 및 경제성을 통합 고려한 공동주택 설계요소 제어에 관한 연구)

  • Choi, Doo-Sung;Do, Jin-Seok
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.29-38
    • /
    • 2012
  • The current building energy efficiency rating certification regulation on apartment houses evaluates only the saving rate of energy consumed during operation, i.e. use, of a building, but doesn't consider the energy consumptions and environmental load($CO_2$) emissions occurring during the whole lifetime of a building. So this study calculated the energy consumptions and environmental load emissions occurring during the whole lifetime of a building, selected reference schemes and alternative items by design variables to present a design draft considering energy efficiency and environmental performance, and evaluated the total cost by combining and calculating its direct cost(material and heating cost) and indirect cost(environmental cost), for an existing apartment house as an evaluation object. As a result of analysis, the change of heating cost by alternative items of design variables showed a 4~8% change rate compared to the reference scheme, and the material cost of design variable 7 showed a maximum 4.4 times change rate in the alternative plan 6 compared to the reference scheme. The environmental cost showed a similar change rate to the material cost change rate in general, but showed a similar environmental cost change rate to the heating cost change rate in case of design variables 4-1, 4-2, 7.