• 제목/요약/키워드: Current Range Extension

검색결과 64건 처리시간 0.024초

전류변성기 두 대와 절대 평가 기술을 이용한 2차 전류 범위 확장 (Secondary Current Range Extension of Current Transformers by Using Two Different Current Transformers and Absolute Evaluation Technique)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.72-78
    • /
    • 2009
  • We have developed a current range extension method to obtain the ratio error and phase displacement of a current transformer (CT) by using absolute evaluation method and two different CTs. The method was applied to CTs under test with the current ratios in the range of 5,000 A / 1 A - 20,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Germany using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

전류변성기 절대 평가 기술과 전류변성기 두 대를 이용한 전류 범위 확장 (Current Range Extension of Current Transformers by Using Absolute Evaluation Technique and Two Different Current Transformers)

  • 김윤형;한상길;정재갑;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.69-71
    • /
    • 2008
  • We have developed a current range extension method to obtain the ratio error and phase displacement of a current transformer (CT) by using absolute evaluation method and two different CTs. The method was applied to CTs under test with the current ratios of the range of 5,000 A / 1 A - 20,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Germany using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

  • PDF

소방용 coverall의 기능적 디자인 연구 (A Functional Design of Fire Fighter Coveralls)

  • Kim, Younghee
    • 한국의류학회지
    • /
    • 제26권12호
    • /
    • pp.1739-1748
    • /
    • 2002
  • 본 연구의 목적은 소방용 coverall의 디자인이 소방수들의 동작기능성에 어떤 영 향을 주는지에 관하여 고찰하여, 보다 기능적 인 coverall을 개발, 궁극적으로 작업자의 노동력을 향상시키고, 보다 안락한 환경 속에서 작업할 수 있도록 도와주는데에 있다. 미국 캔사스 지역의 전문 소방수를 대상으로, interview 및 video analysis를 통하여, 그들이 현재 사용하고 있는 current coverall의 동작기능면에서의 문제점을 조사, 분석한 후, 이를 바탕으로 prototype coverall을 개발하였다 prototype coverall의 동작기능성을 객관적으로 측정하기 위하여 10가지 실험동작(shoulder adduction/ abduction, shoulder flexion/extension, trunk flexion/extension(standing), hip flexion/extension(knee), hip flexion/extension(trunk), upper leg flexion, trunk lateral flexion, hip adduction, trunk flexion/ extension(sitting), upper leg flexion)을 선택하여 이의 관절각도(range-of-motion)를 Leighton flexometer, goniometer, computer-aided method를 이용하여 측정하였으며, 착용자의 주관적 평가를 위하여서는 23 항목의 wearer acceptability scale를 사용하였다. ANOVA(Analysis of Variance)와 LSD(Least Significant Difference)를 이용한 통계처리 결과, prototype coverall이 current coverall에 비해 동작기능성 (특히 crotch, torso, hip movement)에 있어서 우수함을 보이고 있다.

아크 용접 와이어의 장거리 송급을 위한 Push-pull 방식의 와이어 송급장치 개발 (Development of Push-pull Type Arc Welding Wire Feeder)

  • 윤현준;황인성;김동철;강문진;최기갑
    • Journal of Welding and Joining
    • /
    • 제31권3호
    • /
    • pp.39-43
    • /
    • 2013
  • It is difficult to feed welding wire stably, when the distance between welding wire feeder and welding torch is far enough. In order to solve this problem, arranging a extension wire feeder between them could be one of useful methods. However, the welding wire could be twisted up in the extension cable between extension and terminal wire feeders in the case that RPM of extension wire feeding motor is higher than that of terminal motor. In this study, feeding problem of normal push-pull wire feeding system occurred at low welding current range less than 250A. In order to solve the problem, two new wire feeding systems of push-pull type were introduced. Welding wire feeding tests were preformed in the range of 150A to 400A with the developed push-pull feeding system. In addition, weldability test was performed at the welding current of 200A, 300A, and 400A. The welding wire twisting problem that was observed in the normal feeding system did not occur in the new push-pull wire feeding system.

지방행정체계 개편에 따른 농촌지도조직의 대응방안 연구 (A Study on the Countermeasures of Agricultural Extension Service Agencies by Reorganization of Local Administrative System)

  • 윤의영
    • 농촌지도와개발
    • /
    • 제16권1호
    • /
    • pp.21-49
    • /
    • 2009
  • There is a wide range of agreement for reorganization of administrative units. It is expected that regionalization of city governments and city-county consolidation would contribute to enhance efficiency of extension services and weaken citizen accessibility, responsiveness, and participation. Therefore, it is suggested that branch office of extension center should be provided to the isolated rural areas in order to maintain the appropriate level of services. Also, the relationship and linkage between the national/regional government and local extension centers should be reshaped by making current linkage system such as monthly Provincial Meeting and central-local association more effective. Establishment of agricultural database of each local region is needed to strengthen local extension center's role. Finally, extension service agency needs to consider to expand its function from the traditional extension services to a variety of 'rural issues.'

  • PDF

Monitoring of Rice Quality for Jeonju Bibimbab

  • Lee, Song-I;Lee, Deok-Ryeol;Cho, Seung-Hyun;Kim, Kab-Cheol;So, Soon-Young;Lee, Ki-Kwon
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.370-370
    • /
    • 2017
  • This study was carried out to investigate the current use and the demand for Jeonju-bibimbab rice and to suggest the suitable range of bibimbab rice. We conducted a survey on varieties and rice quality of Jeonju bibimbab restaurants from April to August 2016. In a survey of 12 bibimbab restaurants in Jeonju, the restaurants showed that 83% of the 10 restaurants were using shindongjin rice variety. Characteristics of rice suitable for bibimbab were showed low stickiness, high hardness, so it should keep the shape of rice when cooked and mixed with the ingredients. and people tend to prefer a large grain of rice. Also, the rice used in bibimbab restaurants were examined the average percentages of head rice ratio 89%, protein content 6% and moisture content 14.5%. These results suggest that the quality of rice, which is suitable for bibimbab, is similar to the range of common rice. Thousand grain weight over 24g is especially preferred. In conclusion, the quality and grain size of rice preferred for bibimbab rice was the level of Shindongjin.

  • PDF

Extension of the Operating Speed for Vector-Controlled Induction Machine Drives in the Overmodulation Range

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.477-486
    • /
    • 2012
  • This paper proposes a novel current control scheme for vector-controlled induction machine (IM) drives in the overmodulation (OVM) range, with which the voltage utilization of the voltage-source inverter (VSI) can be maximized. In the OVM region, the original voltage reference is modified by changing its magnitude and angle, which causes the motor current to be distorted, resulting in a deterioration of the current control performance. To meet with this situation, the harmonic components in the feedback currents should be eliminated before being input to the PI current controllers. For this, a composite observer is applied to extract the fundamental and harmonic components from the distorted currents, which gives a good performance without a delay and the effect of a fundamental frequency variation. In addition, through a detailed analysis of the response of the PI current controllers in the OVM range, the effectiveness of using the composite observer is demonstrated. Simulation and experimental results for a 3-kW induction motor drive are shown to verify the validity of the proposed method.

전십자인대 재건술 후 고식적 재활과 적극적 재활의 결과 (Results of Conventional and Accelerated Rehabilitation Following ACL Reconstruction)

  • 이병일;민경대;최중근;유재응;손치수
    • 대한관절경학회지
    • /
    • 제1권1호
    • /
    • pp.132-138
    • /
    • 1997
  • The purpose of this study is to compare the results between conventional and accelerated rehabilitation program following ACL reconstruction using bone-patellar tendon-bone. Conventional rehabilitation focused on protecting the new ligament by blocking terminal extension and avoiding active quadriceps function in the terminal degrees of extension. But there is current trend toward early postoperative mobilization and intensive. so called 'accelerated', rehabilitation stressing hyperextension of the knee. The results of intraarticular ACL reconstruction with conventional and accelerated rehabilitation were prospectively compared for one year postoperatively in a series of 27 patients. Range of motion and thigh circumference were checked preoperatively, and weekly up to 8 weeks, 3 months. 6 months, and 1 year postoperatively. Stress radiologic test, KT-1000 arthrometer. Cybex II dynamometer were checked in preoperatively, and 3 months, 6 months, and 1 year postoperatively. There were no differences of objective stability and restoration of muscle power. But the accelerated group had a low incidence of extension loss. excellent range of motion, and less difference of thigh circumference. We concluded that accelerated rehabilitation program is recommendable due to superiority in terms of range of motion, especially less extension loss without increasing laxity of knee joint.

  • PDF

GMA 용접의 용착속도에 미치는 Contact-tube와 모재간 거리의 영향 (Effect of Contact-tube to Work Distance on the Melting Rate of GMA Welding)

  • 경규담;이정헌;천홍정;박병희;강봉룡;김희진
    • Journal of Welding and Joining
    • /
    • 제14권5호
    • /
    • pp.87-94
    • /
    • 1996
  • It has been well known in GMA welding process that wire feeding speed (WFS) or deposition rate increases linealy with the increase of wire extension. In this investigation, however, such an well-known relationship was .reconsidered in terms of contact-tube to work distance (CTWD) instead of wire extension. To verify the proposed relationship between WFS and CTWD, bead-on-plate welding was performed with various CTWDs in the range of 15∼35mm under the condition of near-constant voltage and current As expected, the test results showed an excellent linear relation between WFS and CTWD. Furthermore, the value of the slope turned out to be quite similar to those of previous investigators obtained either theoretically or experimentally through the Precise measurement of electrode extension. Present result also demonstred that the increase of CTWD could be very practical measure for increaring deposition rate without any increase of heat input Depending on the tip recess the practical maximum of CTWD was appeared to be limited somewhere in 25∼30mm mainly due to the entrappment of porocity.

  • PDF

철심형 전류변성기의 비오차 및 위상오차 절대 평가 기술의 확장 : 1차 전류 = $5\;kA{\sim}40\;kA$ (Extension of Absolute Evaluation Technique for Ratio Error and Phase Displacement of Core Type Current Transformers: Ip =$5\;kA{\sim}40\;kA$)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.431-436
    • /
    • 2008
  • We have extended an absolute evaluation method to obtain the ratio error and phase displacement of a current transformer (CT) up to primary current of 40,000 A by measuring four parameters of equivalent circuit in CT. The method was applied to CTs under test with the current ratios in the range of 5,000 A / 5 A - 40,000 A / 5 A. The ratio error and phase displacement of the CTs under test obtained in this study are consistent with those measured at the national institutes in Canada and Germany using the same CTs under test within an expanded uncertainty (k = 2) in the overall current ratios.