• Title/Summary/Keyword: Current Pole

Search Result 383, Processing Time 0.025 seconds

Active RC Filter (능동 RC 여파기)

  • 이흥구;이문기
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.7 no.1
    • /
    • pp.9-17
    • /
    • 1970
  • The paper presents pole optimization in RC network of active RC filter using current inversion negative impedance converter. And also empais is placed on improving the stability of the active RC filter. Experimental results obtained with active RC low pass filter, having Chebyshev 2nd order response and modular angle 55$^{\circ}$, cutoff frequency 3.4KC, are shown and compared with theoretical curves.

  • PDF

Characteristic Analysis of Square Wave BLDG Motor Using finite Element Method (유한요소법에 의한 구형파 전압구동 BLDC 전동기의 특성해석애 관한 연구)

  • Kang, Y.G.;Kwon, B.I.;Im, T.B.;Park, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.9-11
    • /
    • 1997
  • This paper deals with the characteristic analysis of a brushless permanent magnet d.c. motor. The rotor has ring-type permanent magnet magnetized by a capacitor discharge magnetizer with multi-pole fixture. Torque and current characteristics are analyzed by the time-stepped finite element method. And then the results are compared with experimental values.

  • PDF

A Study for Improving the Power Factor of Distribution Transformer using Condenser Control Circuit (콘덴서 제어회로를 이용한 배전용 변압기의 역률 개선에 관한 연구)

  • Lee, Kwang-Jeek
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.21-28
    • /
    • 2014
  • Daily use characteristics of apparent power supplied to distribution transformer can be separated into two different time zone of waking hours and sleeping hours. In sleeping hours, using amount of power is decreasing. The actual curve of power seemed to be quite similar to this kind of separation. Inserting a condenser into a circuit in each different time zone led to maximize power factor of the transformer. The compensating condenser's on/off time is controlled by hysteresis circuit utilizing op amp and power factor of the transformer was improved from 0.945 to 0.999. As a result, the average of current reduction was 2.53A per hour of transformer.

Modeling of a Transfer Function for Frequency Controlled Resonant Inverters

  • Han, Mu-Ho;Lee, Chi-Hwan;Kwon, Woo-Hyun
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.567-574
    • /
    • 2009
  • A linear transfer function for the output current control of frequency-controlled resonant inverters is proposed in this paper. The circuit of resonant inverters can be transformed into two coupled circuits through the complex phasor transform. The circuits consist of cross-coupled power sources and passive elements. The circuits are used to induce the state space equation, which is transformed into the $4^{th}$ order cross-coupled transfer function. The $4^{th}$ order cross-coupled transfer function is modeled into a $2^{nd}$ order linear transfer function based on a behavior analysis of the pole and zero locations that facilitate a simple and intuitive linear transfer function. The feasibility and validity of the proposed linear transfer function were verified by simulation and experiment.

The Design, Manufacture and Characteristic Experiment of a Small-Scaled High-Tc Superconducting Synchronous Motor (소용량 고온초전도 동기모터의 제작 및 특성 실험에 관한 연구)

  • Soug, Myung-Kon;Yoon, Yong-Soo;Hong, Gye-Won;Jang, In-Bae;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.241-243
    • /
    • 1999
  • This paper describes a series of experiments investigating the operational characteristics of high-Tc superconducting synchronous motor of five to six hundred watts capacity. In this experiment, ac 220V stator phase voltage and DC 4A excitation current are used, and the synchronous speed runs at 1800rpm. Hall Sensors are installed on the pole face and at the side of the Ag/Bi-2223 high-Tc superconducting tape in order to analyze the effect of the time-varying magnetic field on the motor performance when the load changes its value. The experimental observations are compared with the theoretical predictions.

  • PDF

Commutation Characteristic Analysis of DC Motor for Circuit Parameters (회로정수를 이용한 직류전동기의 정류 특성 해석)

  • Kim, Young-Sun;Lee, Joon-Ho;Lee, Ki-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.641-643
    • /
    • 2000
  • Because of high torque and easiness of speed control, Direct Current(DC) motors are used long time. But, its applications are limited in circumstance and performance, since they contained brush and commutator. The commutation characteristic gives effect to life and performance of DC motor. Naturally, the commutation characteristic analysis is strongly required. In this paper, With the result of finite element analysis. The inductance is calculated each rotor position and applied to the voltage equations coupled with commutation equation. The time derivative term in the differential equation is solved in time difference method. This algorithm was applied to 2-pole shunt DC motor. We considered commutation characteristic by changing contact resistance between brush and commutator segment.

  • PDF

Friction of Superconductor Bearing (초전도 베어링의 마찰계수 측정)

  • ;J. R Hull
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.237-239
    • /
    • 2003
  • A high-temperature superconductor (HTS) journal bearing was studied for loss. Two HTS bearings support the rotor at top and bottom. The rotor weight is 4 kg and the length is about 300 mm. Both the top and bottom bearings have two permanent magnet (PM) rings with an iron pole piece separating them. Each HTS journal bearing is composed of six pieces of superconductor blocks of size 35$\times$25$\times$10 mm. The HTS blocks are encased in a cryochamber through which liquid nitrogen flows. The inner spool of the cryochamber is made from G-10 to reduce eddy current loss, and the rest of the cryochamber is stainless steel. The magnetic field from the PM rings < 10 mT on the stainless part. The rotational drag was measured over the same speed range. Results indicate that the 10 mT design criteria for magnetic field on the stainless part of the cryochamber is too high.

  • PDF

An Experimental Study on the Response of Concrete Pole to Impulsive Current (콘크리트전주의 임펄스전류 응답에 대한 실험적 고찰)

  • Park, Sang-Man;Kang, Moon-Ho;Jeong, Yeong-Ho;Ryoo, Hee-Suk;Nam, Kee-Young;Lee, Jae-Duck;Jung, Dong-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.482-484
    • /
    • 2003
  • 특별고압 가공배전선로는 일반적으로 콘크리트전주를 지지물로 하고 있고, 선로의 상부에는 가공지선을, 하부에는 중성선을 설치하되, 매전주에서 가공지선, 중성선, 완철을 서로 접속하고 적절한 경간마다 전주에서 접지하도록 하고 있다. 또한 콘크리트전주는 기계적 강도의 유지를 위하여 철근이나 강선을 주골재로 사용하면서도 설계기준에서는 콘크리트전주의 뇌격에 대한 접지효과를 고려하지 않고 있는데, 실험에 의해, 접지선에 어느 정도 이상의 임펄스전류가 흐르면 전주의 철근이 접지회로의 일부를 구성하는 것으로 확인되었다. 본 논문에서는 콘크리트전주의 뇌임펄스에 대한 응답을 실험적으로 고찰하였다.

  • PDF

Commutation Modeling and Characteristic Analysis of DC Motor using Circuit Parameters (회로정수를 이용한 직류전동기의 정류회로 모델링 및 특성 해석)

  • Kim, Young Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.57-62
    • /
    • 2013
  • Because of high torque and easiness of speed control, Direct Current(DC) motors have been used for a long time. But, its applications are limited in circumstance and performance, since they contained brush and commutator. The commutation characteristic gives effect to life and performance of the DC motor. Naturally, the commutation characteristic analysis is strongly required. In this paper, With the result of finite element analysis, The inductance is calculated each rotor position and applied to the voltage equations coupled with commutation equation. Also, contact resistances of brush/commutator assembly are considered using contact area and brush width converted with commutator segments. The time derivative term in the differential equation is solved in time difference method. This algorithm was applied to 2-pole shunt DC motor. We considered commutation characteristic by changing contact resistance between brush and commutator segment.

Measuring the Average Torque according to Exciting Region of Single Phase SRM (단상 SRM의 여자구간에 따른 평균 토크 측정)

  • Kim Yong-Heon;Lee Eun-Woong;Lee Jong-Han;Lee Hyeon-Woo;Kim Jun-ho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.989-991
    • /
    • 2004
  • There are many elements that affect the average torque of the single phase SRM. It is related with the stator and rotor pole arcs, the dwell angle of the exciting current, the turn on/off angle, etc., Most of all, the turn on/off angle is affect the design procedure of the driving and control circuit. So, in this study, it is intend to analyze the effect that the variations of the turn on/off angle affects the average torque. and then this analyses will be used to design the control driver of the single phase SRM.

  • PDF