• 제목/요약/키워드: Current Interruption

검색결과 203건 처리시간 0.027초

경량전철 제 3궤조 집전특성에 관한 연구(I) (The Study on the Third Rail Current Collecting Characteristics for Light Rail Transit)

  • 정락교;김연수;박성혁;목진용;이정식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.530-536
    • /
    • 1998
  • In the design of the light rail transit which is more reliable and economical, it is essential to develope a efficient third rail system. Especially, the analysis for the conductivity of conduct rail and the wear of collecting shoe is the first step of its development. In this paper, experiments for conductivity in conductor rail, wear in collecting shoe were performed respectively as different materials of conductor rail and current collector. Noise level and interruption, wear and contact resistance of collecting shoe were proposed as design parameters for the development of this system. Experimental equipment and methods of design parameter stated above were proposed, which is expected that analyzed results will be used as a basic data for the development of the system.

  • PDF

자율분산 역 제어시스템 모의시험 연구 (A study on the simulation test of Autonomous station control system)

  • 김영훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.2045-2050
    • /
    • 2008
  • The Autonomous station control system by applying the concepts of autonomous decentralized system is a system which can solve the problems of the current central control system. The Autonomous station control system tester developed in order to test for Autonomous station control system. The main function of tester is a time-deadline test, a schedule broadcast test, a route control test and a version-up test, etc. In the paper, we build the reliability of the Autonomous station control system by testing the Autonomous station control system tester. Also, the test enable the on-line test without the system interruption and verify the function of the Autonomous station control system developed by applying the concepts of Autonomous decentralized system to the current Central control system.

  • PDF

Understanding Switching Arcs and Dielectric Capability of a SF6 Self-Blast Interrupter

  • 이원호;김철수;이종철
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.196.2-196.2
    • /
    • 2016
  • The design and development procedures of SF6 gas circuit breakers are still largely based on trial and error through testing although the development costs go higher every year. The computation cannot cover the testing satisfactorily because all the real processes arc not taken into account. But the knowledge of the arc behavior and the prediction of thermal plasmas inside SF6 interrupters by numerical simulations are more useful than those by experiments due to the difficulties to obtain physical quantities experimentally and the reduction of computational costs in recent years. In this paper, in order to get further information into the interruption process of a SF6 self-blast interrupter, which is based on the combination of thermal expansion and arc rotation, gas flow simulations with a CFD-arc modeling are performed during the whole switching process such as high-current period, pre-current zero period, and current-zero period. Through the complete work, the temperature of residual arcs as well as the breakdown index after current zero should be a good criterion to predict the dielectric capability of interrupters.

  • PDF

Numerical Study of SF6 arc with Copper Contamination

  • Liau Vui-Kien;Lee Byeong-Yoon;Song Ki-Dong;Park Kyong-Yop
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권6호
    • /
    • pp.233-241
    • /
    • 2005
  • The present model of a SF6 arc accounts for the copper vapour contamination from the electrodes inside a Laval nozzle of a circuit breaker. Steady state simulations have been done for the arc with electrode gap of 60mm and DC electric current of 500A, 1000A and 1500A for both cases with and without copper contamination. The effects of electrode polarity are considered for the arc current of 1000A. It was found out that evaporation of copper from the anode results in a cooling of the arc in a region close to the electrodes. The electrical potential across the electrodes is not sensitive to the presence of copper vapour, typically less than $4\%$ difference. Transient analysis has been done in order to obtain the arc properties at current zero. The arc current is increased linearly from -1000 to 0A when the upstream electrode is cathode with constant dI/dt of $27.0A/{\mu}s$ (or decreased linearly from 1000 to 0A when upstream electrode is anode). It has been predicted that the presence of copper vapour reduces the interruption capability of the breaker.

A Survey on the Current Working Conditions and Job Satisfaction on Aquatic Therapy Performed by Physical Therapists

  • Oh, Sejun;Jeon, Jin Yeong;Lee, Ji Hye;Hwang, Byong Yong;Yoon, BumChul;Nam, Hyoung Chun;Yeom, Jun Woo
    • The Journal of Korean Physical Therapy
    • /
    • 제31권1호
    • /
    • pp.40-48
    • /
    • 2019
  • Purpose: This study assessed the current working conditions and job satisfaction on aquatic therapy performed by physical therapists in South Korea. Methods: A total of 139 (managers: 53, staff: 86) physical therapists participated in this survey (90 questionnaires) and the data were analyzed using the SPSS 21.0 Windows. Results: The retention conditions of aquatic therapy facilitation was high in the rehabilitation centers (or disabled living facilities) and rehabilitation hospitals. On the other hand, there were regional variations. The physical therapists in this field were likely to have limitations or restrictions of professional aquatic therapy education. The subjects showed a tendency for a career interruption during their fifth working year. The overall job satisfaction on aquatic therapy of physical therapists was high (managers: 94.3%, staff: 95.3%, p=0.276), but the work intensity was higher than the other parts of physical therapy and the relative reward was comparatively low (managers: 60.3%, staff: 66.3%, p=0.865). Conclusion: Based on this study, the current working conditions regarding aquatic therapy by physical therapists were assessed. These results will help enhance aquatic therapy and/or in aquatic therapy facilitation.

기포발생에 따른 초전도 한류기용 YBCO 박막 퀜치특성 연구 (A Study of Quench Behaviors in YBCO Flims for Superconducting Fault Current Limiter)

  • 강종성;박권배;이방욱;오일성;김혜림
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.796-798
    • /
    • 2002
  • In these days, the interruption capability of some circuit breakers, which are installed in the transmission systems, is getting lower than the magnitude of the fault current because of continuous increase of power demand and relatively short power line which was installed in forms of mesh network As a result of these situations, fault current limiters (FCLs) are strongly necessary. There are various types which is investigated around the world, and new power apparatuses that have been newly considered and developed by many manufactures. In this paper, we considered resistive superconducting fault current limiters with YBCO thin films. The resistive limiters utilize a transition of YBCO films from superconducting to normal state caused by exceeding the critical current. By means of newly occurred impedance, the fault current will be limited effectively. Generally, a few current path patterns are available for YBCO films to enhance the current limiting performance of YBCO films. In this paper. the meander-type and the bi-spiral-type were used for current paths of YBCO flims. When YBCO films are quenched into the normal state, bubbles could be observed on the surface of YBCO films. Using our high-speed camera, the number of bubbles and the size of bubbles could be visualized and the relation between bubbles and current density was analyzed. By means of moving pictures of bubbles, we observed how the quench extended or how the heat was conducted in films.

  • PDF

고속열차 운행에 따른 호남고속철도 궤도회로 귀선전류 영향 분석 (Analysis of Return Current Effect for Track Circuit on Ho-Nam high Speed Line)

  • 백종현
    • 한국통신학회논문지
    • /
    • 제42권5호
    • /
    • pp.1110-1116
    • /
    • 2017
  • 동작 특성에 따라 궤도회로 장치는 신호기 장치, 선로전환기 및 기타 안전과 관련된 장치의 직접 또는 간접 제어를 위해 설치되며, 주로 열차의 검지, 지상에서 차상으로 제어정보 전송, 궤도 깨짐 검지 및 귀선 전류 전송에 사용된다. 특히 귀선 전류는 신호시스템, 전력시스템 및 전차선 및 궤도회로장치와 관련이 있다. 신호시스템에서 가장 중요한 구성 요소 중 하나인 귀선 전류는 선로변 유지보수자의 안전 및 전철화에 따른 철도 관련 전기시스템의 보호를 위해 적합하게 처리되어야 한다. 따라서, 과전류 상태로 인한 귀선 전류 불평형과 시스템 유도 장애 및 고장을 방지하기 위해서는 귀선 전류의 정확한 분석이 필요하다. 또한, 귀선전류 고조파에 의해 오동작이 발생하면 열차 운행 중단 등의 문제가 발생될 수 있다. 본 논문에서는 이러한 귀선 전류 측정 및 분석 방법을 제시하고 고속열차 운행에 따른 호남고속철도 노선에서의 귀선전류 고조파 시험 결과를 제시하고 있다.

소형 HTS SMES와 실시간 전력계통 시뮬레이터의 연계 알고리즘 제안 (Connection Algorithm Proposal of Real Time Digital Simulator with Miniaturized HTS SMES)

  • 김아롱;김경훈;김광민;박민원;유인근;심기덕;김석호;성기철;박영일
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.96-101
    • /
    • 2010
  • Superconducting Magnetic Energy Storage (SMES) system is one of the key technologies to overcome the voltage sag, swell, interruption and frequency fluctuation by fast response speed of current charge and discharge. In order to evaluate the characteristics of over mega joule class grid connected High Temperature Superconducting (HTS) SMES system, the authors proposed an algorithm by which the SMES coil could be connected to the Real Time Digital Simulator (RTDS). Using the proposed algorithm, users can perform the simulation of voltage sag and frequency stabilization with a real SMES coil in real time and easily change the capacity of SMES system as much as they need. To demonstrate the algorithm, real charge and discharge circuit and active load were manufactured and experimented. The results show that the current from real system was well amplified and applied to the current source of simulation circuit in real time.

배전자동화 시스템의 서비스 향상을 위한 P2P 기반의 분산형 통신망 구조 (A Distributed Communication Architecture Based on the Peer-to-Peer Model for Enhancing Distribution Automation System Services)

  • 임일형;홍석원;최면송;이승재;하복남
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.443-450
    • /
    • 2007
  • We overview the current distribution automation system in Korea and point out the limitations of the distribution services which can be provided by the current system. In this paper we propose a new distribution system architecture which is based on the peer-to-peer communication model. In this decentralized architecture the intelligent FRTUS can initiate data transmission without any interruption of a central server, and can exchange data with other FRTUS as peers. In order to support the peer-based distribution system, we specify the requirements for new communication network and suggest a way of improving the current distribution network where we adapt an intelligent module for protection and restoration, called MASX, and utilize the open communication network protocols. We also show how the new architecture can enhance major distribution services such as protection, automatic restoration, and equipment management.

Experimental Investigations Into Low Current Steady State Arcs In A Dual-Airflow Model Interrupter

  • Shin, Young-June;Cho, Yun-Ok;Kim, Jin-Gi;Lee, Jeong-Rim
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.961-965
    • /
    • 1992
  • It is well-known that shock waves frequently occur inside the nozzle of the interrupter, and that they play important roles in the arc interruption. A model interrupter with two-dimensional dual-airflow nozzles was used for this experiment. The arc was ignited with 1.4 mil copper wire stretched between the electrodes which were spaced out 56 mm. The arc current of 60 to 230 A was achieved by adjusting the external resistance from 5.5 to 1.6 ohms. The arc tests have been conducted for investigating the air arc characteristics, and the effects of shock waves and nozzle pressure ratios on the arc voltage, the arc resistance, the arc power, and average electric field. The results of these tests have been analyzed to provide insights into the arc characteristics for gas circuit breakers. The average electric field is represented by the function of the arc current to show the negative E-I characteristic explicitly. The effects of shock waves and nozzle pressure ratios are shown to be significant for a circuit breaker performance.

  • PDF