• 제목/요약/키워드: Current Fed Inverter

검색결과 210건 처리시간 0.031초

브러시리스 DC 모터의 모델링과 동특성 해석 (The Analysis of Dynamic Characteristics and Modeling of Brushless DC Motor)

  • 최병인;백수현;김용;윤신용;임태빈;김철진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.200-204
    • /
    • 1998
  • In this paper, a mathematical model of Brushless DC machine fed by pwm inverter is developed. Dynamic and steady state characteristics of Brushless DC motor is simulated and analyzed: electromagnetic torque, speed, phase voltage, and current. In mathematical modeling, the shaft transformation referencing rotor frame from to "a,b,c" three phase frame to "d,g" two phase frame is described.

  • PDF

영구자석형 동기전동기의 직접토크제어 시뮬레이션 (Simulation of Direct Torque Control of PM Synchronous Motor Drive)

  • 김재형;박건태;차득근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.252-255
    • /
    • 2001
  • In this paper, a mathematical model of permanent magnet synchronous motor (PMSM) fed by inverter with Direct Torque Control (DTC) Dynamic and steady state characteristics of PMSM is simulated and analyzed: electro-magnetic torque response, speed response, locus of the stator flux linkage. It is mathematically proven that the increase of electromagnetic torque in a permanent magnet motor is proportional the increase of the angle between the stator and rotor flux linkages, and, therefore, the fast torque response can be obtained by adjusting the rotating speed of the stator flux linkage as fast as possible. The simulation results verify the proposed control and also show that the torque response under DTC is much faster than the PWM current controlled drive.

  • PDF

인버터 구동 유도전동기의 계통사고 해석 (System Fault Analysis of Inverter Fed Induction Motor drives)

  • 권영목;김재철;송승엽;신중은
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.304-306
    • /
    • 2004
  • Recently, operating equipment with the high quality is necessary as technology is developing rapidly and equipment becomes more accurate. Therefore, the importance of diagnosis has been rising in modem industries. This paper presents that the induction motor is driven by invertor. We were using EMTP (Electromagnetic Transient Program) to study different characteristics of induction motor caused by faults; single phasing and the short circuit fault. After having the fault occurred in feeder cable, motor current, flux and torque waveform are analyzed

  • PDF

DSP 인버터를 이용한 반송용 선형기기의 추력제어를 위한 슬립 각 주파수 벡터제어 (Vector Control using a Slip Angle Frequency for the Thrust Control of SLIM Used a Conveyor by the Inverter Based DSP)

  • 신동률;허태원;박지호;조용길;노태균;우정인
    • 조명전기설비학회논문지
    • /
    • 제14권3호
    • /
    • pp.29-37
    • /
    • 2000
  • 본 논문에서는 TMS320C32 DSP를 사용하여 저속에서 구동되는 반송용 펀측식 전행 유도전동기의 슬립 각 주파수에 의한 벡터제어를 이용하여 추력제어하였다. 먼저, 반송용 편촉식 선형 유도전동기를 설계 및 제작하고, 이를 해석하였다. 저속에서 제풍의 운반시에 안정성있은 구동올 위해서 벡터제어에 의한 추력제어를 하였고, 정위치 제어를 하기 워해서 Ziegles- Nichols법을 이용하여 PiD제어기를 설계하였다. 저속에셔의 종량부하흘 갖는 반송용 선형기기에서 PID제어기에 추력제어가 가능한 벡터제어기법을 부가한 결과는 제품외 운반시에 안정성있는 구동을 하였으며, 정위치제어를 위한빠른 응답특쟁 및 soft start/stop을 이루었으며, 부하 변동시에도 제동시에 정위치제어를 위한 빠른 응탑 특성의 결과를 얻었다.

  • PDF

EMI Noise Reduction with New Active Zero State PWM for Integrated Dynamic Brake Systems

  • Baik, Jae-Hyuk;Yun, Sang-Won;Kim, Dong-Sik;Kwon, Chun-Ki;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.923-930
    • /
    • 2018
  • Based on the application of an integrated dynamic brake (IDB) system that uses a PWM inverter fed-AC motor drive to operate the piston, a new active zero state PWM (AZSPWM) is proposed to improve the stability and reliability of the IDB system by suppressing the conducted electro-magnetic interference (EMI) noise under a wide range of load torque. The new AZSPWM reduces common-mode voltage (CMV) by one-third when compared to that of the conventional space vector PWM (CSVPWM). Although this method slightly increases the output current ripple by reducing the CMV, like the CSVPWM, it can be used within the full range of the load torque. Further, unlike other reduced common-mode voltage (RCMV) PWMs, it does not increase the switching power loss. A theoretical analysis is presented and experiments are performed to demonstrate the effectiveness of this method.

LED 비상 유도등 동작을 위한 태양광발전 계통연계 전원동기 방식의 전압형 인버터 구동 특성 (Characteristic of VSI Driven by Source Synchronous Type for the Utility Interactive using a Photovoltaic Generation for the LED Luminaire Emergency Exit Sign Operation)

  • 황락훈;나용주
    • 한국항행학회논문지
    • /
    • 제22권5호
    • /
    • pp.420-428
    • /
    • 2018
  • 본 논문은 태양광 발전시스템을 승압쵸퍼와 단상 펄스폭변조 전압형인버터를 사용하여 전원차단 경우나 전압변동 및 부하변동에 의한 출력전류 변화에도 일정한 출력전압을 유지하는 무정전 전원 공급장치(UPS)를 구성하였다. 본 시스템은 전압형인버터를 교류전원과 동기 시켜서 운전하고 정상상태에서는 전원으로부터 운전하고 정상상태에서는 전원으로부터 직류 측에 연결된 축전지를 태양전지를 이용한 광기전력효과와 함께 일정전압을 충전하며, 전원의 차단, 전원의 전압변동 및 부하전류의 변화에도 일정한 전압을 유지하도록 하였다. 에너지 저장장치 (ESS; energy storage system)를 상시 운영하여 공항의 기상 변화에 따른 파장별 LED 항공 유도신호 등을 효율적으로 운용하는 시스템을 구성 하였고, 전력절감효과를 얻을 수 있는 에너지절약 전원복합형 전력변환장치로 구성되어 있다. 출력은 PWM방식에 의하여 양호한 파형이 되도록 하고 전원차단과 부하의 상태의 변화 및 전원 전압 변동에도 일정한 전압으로 출력됨을 실험을 통하여 확인 할 수 있었다.

A Novel Prototype of Duty Cycle Controlled Soft-Switching Half-Bridge DC-DC Converter with Input DC Rail Active Quasi Resonant Snubbers Assisted by High Frequency Planar Transformer

  • Fathy, Khairy;Morimoto, Keiki;Suh, Ki-Young;Kwon, Soon-Kurl;Nakaoka, Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.89-97
    • /
    • 2007
  • This paper presents a new circuit topology of active edge resonant snubbers assisted half-bridge soft switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed half-bridge high frequency PWM inverter with a high frequency planar transformer link in addition to input DC busline side power semiconductor switching devices for PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC buslines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, a high switching frequency IGBTs can be actually selected in the frequency range of 60 kHz under the principle of soft switching. The performance evaluations of the experimental setup are illustrated practically. The effectiveness of this new converter topology is proved for such low voltage and large current DC-DC power supplies as DC bus feeding from a practical point of view.

Rotor Failures Diagnosis of Squirrel Cage Induction Motors with Different Supplying Sources

  • Menacer, Arezki;Champenois, Gerard;Nait Said, Mohamed Said;Benakcha, Abdelhamid;Moreau, Sandrine;Hassaine, Said
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권2호
    • /
    • pp.219-228
    • /
    • 2009
  • The growing application and the numerous qualities of induction motors (1M) in industrial processes that require high security and reliability levels has led to the development of multiple methods for early fault detection. However, various faults can occur, such as stator short-circuits and rotor failures. Traditionally the diagnosis machine is done through a sinusoidal power supply, in the present paper we study experimentally the effects of the rotor failures, such as broken rotor bars in function of the ac supplying, the load and show the impact of the converter from diagnosis of the machine. The technique diagnosis used is based on the spectral analysis of stator currents or stator voltages respectively according to the types of induction motor ac supplying. So, four different ac supplying are considered: ${\odot}$ the IM is directly by the balanced three-phase network voltage source, ${\odot}$ the IM is fed by a sinusoidal current source given the controlled by hysteresis, ${\odot}$ the IM is fed (in open loop) by a scalar control imposing through ratio V/f=constant, ${\odot}$ the IM is controlled through a vector control using space vector pulse width modulation (SVPWM) technique inverter with an outer speed loop.

계통연계형 태양광 발전시스템의 태양전지 전류 추정을 위한 슬라이딩 모드 관측기 설계 (Design of Sliding Mode Observer for Solar Array Current Estimation in the Grid-Connected Photovoltaic System)

  • 김일송;백인철;윤명중
    • 전력전자학회논문지
    • /
    • 제10권4호
    • /
    • pp.411-419
    • /
    • 2005
  • 본 논문에서는 계통연계형 태양광 발전시스템의 태양전지 전류 추정을 위한 슬라이딩 모드 관측기 설계 방법이 제시되었다. 태양전지 전류 추정 정보는 슬라이딩 모드 관측기에서 얻어지고, 기준전압을 갱신하기 위한 최대전력 추적기의 입력정보로 사용되어 진다. 계통연계형 인버터의 입력 커패시턴스 값은 규정치의 50[$\%$] 정도까지 바뀔 수 있으며, 선형 관측기는 파라미터 변화나 외란이 존재하는 조건에서는 정확한 상태값을 추정할 수 없다. 슬라이딩 모드 관측기의 구조는 간단하지만, 파라미터 변화나 외란에서도 슬라이딩 모드 관측기는 강인한 추종능력을 보여주고 있다. 본 논문에서는 등가 입력조건을 이용한 슬라이딩 모드 관측기를 설계하는 방법이 제시되고, 제시된 관측기의 수렴조건에 대해 서술하였다. 수학적인 모델링과 실험결과로서 제안한 방법의 타당성을 입증하였다.

MRAS Based Sensorless Control of a Series-Connected Five-Phase Two-Motor Drive System

  • Khan, M. Rizwan;Iqbal, Atif
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.224-234
    • /
    • 2008
  • Multi-phase machines can be used in variable speed drives. Their applications include electric ship propulsion, 'more-electric aircraft' and traction applications, electric vehicles, and hybrid electric vehicles. Multi-phase machines enable independent control of a few numbers of machines that are connected in series in a particular manner with their supply being fed from a single voltage source inverter(VSI). The idea was first implemented for a five-phase series-connected two-motor drive system, but is now applicable to any number of phases more than or equal to five-phase. The number of series-connected machines is a function of the phase number of VSI. Theoretical and simulation studies have already been reported for number of multi-phase multi-motor drive configurations of series-connection type. Variable speed induction motor drives without mechanical speed sensors at the motor shaft have the attractions of low cost and high reliability. To replace the sensor, information concerning the rotor speed is extracted from measured stator currents and voltages at motor terminals. Open-loop estimators or closed-loop observers are used for this purpose. They differ with respect to accuracy, robustness, and sensitivity against model parameter variations. This paper analyses operation of an MRAS estimator based sensorless control of a vector controlled series-connected two-motor five-phase drive system with current control in the stationary reference frame. Results, obtained with fixed-voltage, fixed-frequency supply, and hysteresis current control are presented for various operating conditions on the basis of simulation results. The purpose of this paper is to report the first ever simulation results on a sensorless control of a five-phase two-motor series-connected drive system. The operating principle is given followed by a description of the sensorless technique.