• Title/Summary/Keyword: Current Density and Temperature Distribution

Search Result 142, Processing Time 0.028 seconds

미소 방전존재시의 ${SF}_{6}$에 대한 교류절연 파괴 특성 (A.C Breakdown Characteristics in ${SF}_{6}$ in the Presence of A Small Discharge)

  • 이광식;이동인;김인식
    • 대한전기학회논문지
    • /
    • 제39권3호
    • /
    • pp.321-328
    • /
    • 1990
  • The effect of a small discharge on the A.C (60Hz) breakdown characteristics in SF6 gas has been studied. Various experiments were investigated while varying distance of the rod-plane electrode, the gas pressure, and the magnitude of the small discharge current. Also, the position of the discharge path was observed for the purpose of evident investigation. As the results of this study, authors clarified the shifting mechanism of the position of discharge path with the ratio Rn (E/N distribution at a certain higher tempera-ture due to the small discharge current to E/N distribution at room temperature, E:electric field strength, N:particle number density). Also, the reason for the reduction of the A.C. breakdown voltage was investigated in the presence of a small discharge current.

  • PDF

물질순환모델을 이용한 제주항의 수질관리(I) - 제주항의 물리해양환경의 변화 - (Water quality management of Jeiu Harbor using material cycle model(I) - The Variation of Physical Oceanographic Environments in Jeiu Harbor -)

  • 조은일;이병걸;오윤근
    • 한국환경과학회지
    • /
    • 제11권1호
    • /
    • pp.25-32
    • /
    • 2002
  • In order to control of water quality in Jeju harbor, variation of physical oceanographic environments was estimated using material cycle model. It is composed of the three-dimensional hydrodynamic model for the simulation at water flow and material cycle model for the simulation of water quality. The three dimensional hydrodynamic model simulation of the circulation and mixing in Jeju Harbor has been conducted forced by Sanzi River Discharge, Tidal elevation, wind and Solar heat in case of August and November, 2000 and February and May, 2001, respectively. The results of numerical model and observation show that the model can produce realistic results of current in the harbor. The monthly variation of velocity pattern are not so much changed are found In Jeju Harbor. The residual current was forced by temperature, salinity, density, wind and tidal current. The residual current of August, 2000 are the strongest among four month. It can be explained that the density effect can be important role in residual current at Jeju Harbor. As the results of salinity distribution simulation, very low concentration of all levels were simulated in August, 2000. The flowrate of Sanzi river was investigated 77,760 ㎥ /d in August, 2000. Therefore, pollutant loadings from Sanzi river should be considered for water quality management in Jeiu harbor.

LDPE에서 공간전하분포와 측정전류의 시간특성에 대한 수치해석 (Numerical Analysis about the Time Characteristics of Space Charge Distribution and Measured Current in LDPE)

  • 황보승;박대희;남석현;권윤혁;한민구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권9호
    • /
    • pp.502-509
    • /
    • 2000
  • In this paper in order to evaluat quantitavely the formation mechanism of space charge and its effects on the conduction characteristics in LDPE we have carried out the numerical analysis on the basis of experimental results of space charge distribution cathode field and current with time which had been simultaneously measured at applied field of 50kV/mm and room temperature. As the models for numerical analysis we employ the Richarson-Schottky theory for charge injection from electrode into LDPE and the band-tail conduction at crystalline regions and the hopping conduction by traps which mainly exist at the interface regions of crystalline-amorphous region for charge transport in LDPE. Futhermore in order to investigate the influence of physical parameters on the time characteristcs of space charge distribution and measured current we have changed the values of trap density activation energies for charge injection and transport and have analyzed their effects.

  • PDF

운전 조건에 따른 PEM 연료전지 모델링 및 성능 분석 (Modeling and parametric studies of PEM fuel cell performance)

  • 노영우;김세훈;정귀성;손익제;한국일;안병기
    • 한국수소및신에너지학회논문집
    • /
    • 제19권3호
    • /
    • pp.209-216
    • /
    • 2008
  • In the present study, a mathematical model has been formulated for the performance of polymer electrolyte fuel cells. Modify the concentration polarization equation using concentration coefficient that represents the characteristics of bipolar plate reactant distribution. The model predictions have been compared with experimental results and good agreement has been demonstrated for the cell polarization curves. The effects of operating parameters on the performance of fuel cells have been studied. Increases of operation pressure reduce the effect of temperature on the performance.

Characteristics of a Warm Eddy Observed in the Ulleung Basin in July 2005

  • Shin, Chang-Woong
    • Ocean and Polar Research
    • /
    • 제31권4호
    • /
    • pp.283-296
    • /
    • 2009
  • Oceanographic survey data were analyzed to understand the characteristics of a warm eddy observed in the Ulleung Basin in July 2005. The temperature distribution at 200 db and vertical sections provided evidence of the warm eddy in the Ulleung Basin (UWE05). Based on the 5$^{\circ}C$ isothermal line on 200 db temperature, the major axis was 160 km from southwest to northeast, and the minor axis was 80 km from southeast to northwest. The homogeneous layer in the thermocline of UWE05 had mean values of 10.40$^{\circ}C$ potential temperature, 34.35 psu salinity, and 26.37 kg/m$^3$ potential density (${\sigma}_{\theta}$) and provided evidence that UWE05 also existed during the winter of 2004-2005. A warm streamer initially flowed along the circumference of UWE05 and mixed with the upper central water. Two northward current cores were found on the western side of the measured current section at the central latitude of UWE05. One was the East Korean Warm Current (EKWC) and the other was the main stream of the western part of UWE05. Geostrophic transport of the upper layer (from the surface to the isopycnal surface of 26.9 ${\sigma}_{\theta}$) was approximately 2.5 Sv in the eastern side of UWE05. However, the measured transport was twice as large as the geostrophic transport. Mass conservation of geostrophic transport was well satisfied in the upper layer. The direct current measurements and geostrophic transport analysis showed that the EKWC meandered around UWE05.

Exhaust Plasma Characteristics of Direct-Current Arcjet Thrusters

  • Tahara, Hirokazu
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.327-334
    • /
    • 2004
  • Spectroscopic and electrostatic probe measurements were made to examine plasma characteristics with or without a metal plate for a 10-㎾-class direct-current arcjet Heat fluxes into the plate from the plasma were also evaluated with a Nickel slug and thermocouple arrangement. Ammonia and mixtures of nitrogen and hydrogen were used. The NH$_3$ and $N_2$+3H$_2$ plasmas in the nozzle and in the downstream plume without a plate were in thermodynamical nonequilibrium states. As a result, the H-atom electronic excitation temperature and the $N_2$ molecule-rotational excitation temperature intensively decreased downstream in the nozzle although the NH molecule-rotational excitation temperature did not show an axial decrease. Each temperature was kept in a small range in the plume without a plate except for the NH rotational temperature for NH$_3$ gas. On the other hand, as approaching the plate, the thermodynamical nonequilibrium plasma came to be a temperature-equilibrium one because the plasma flow tended to stagnate in front of the plate. The electron temperature had a small radial variation near the plate. Both the electron number density and the heat flux decreased radially outward, and an increase in H$_2$ mole fraction raised them at a constant radial position. In cases with NH$_3$ and $N_2$+3H$_2$ a large number of NH radical with a radially wide distribution was considered to cause a large amount of energy loss, i.e., frozen flow loss, for arcjet thrusters.

  • PDF

Uncertainty Analysis of Dynamic Thermal Rating of Overhead Transmission Line

  • Zhou, Xing;Wang, Yanling;Zhou, Xiaofeng;Tao, Weihua;Niu, Zhiqiang;Qu, Ailing
    • Journal of Information Processing Systems
    • /
    • 제15권2호
    • /
    • pp.331-343
    • /
    • 2019
  • Dynamic thermal rating of the overhead transmission lines is affected by many uncertain factors. The ambient temperature, wind speed and wind direction are the main sources of uncertainty. Measurement uncertainty is an important parameter to evaluate the reliability of measurement results. This paper presents the uncertainty analysis based on Monte Carlo. On the basis of establishing the mathematical model and setting the probability density function of the input parameter value, the probability density function of the output value is determined by probability distribution random sampling. Through the calculation and analysis of the transient thermal balance equation and the steady- state thermal balance equation, the steady-state current carrying capacity, the transient current carrying capacity, the standard uncertainty and the probability distribution of the minimum and maximum values of the conductor under 95% confidence interval are obtained. The simulation results indicate that Monte Carlo method can decrease the computational complexity, speed up the calculation, and increase the validity and reliability of the uncertainty evaluation.

저온 평판형 고체산화물 연료전지 내부 열 및 물질전달 현상에 대한 전산해석 (Computational Analysis of Heat and Mass Transfer in a Planar-type Solid Oxide Fuel Cell)

  • 정희석;차훈;손정락;노승탁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.648-654
    • /
    • 2005
  • The performance prediction of a planar-type solid oxide fuel ceil is conducted by a computational analysis. The transport processes are formulated with the help of a simplified treatment of heat generation by the electrochemical reaction. From the result of the computational analysis, it is shown that the electrochemical reaction is closely related to the transport phenomena inside a solid oxide fuel cell. Transport phenomena including heat and mass transfer have influence on the distribution of local current density and as a result, on the performance characteristics of the fuel cell. Computational analysis is also extended to the parametric study to investigate the performance behavior of the fuel cell with different amount of supplied fuel flow rates. It is also demonstrated that the mathematical formulation and computational procedures proposed in this study can be applied to prove the importance of the specific TPB(Three-Phase-Boundary) area in the manufacturing process of electrodes in a solid oxide fuel cell.

  • PDF

미세금형 가공을 위한 전기화학식각공정의 유한요소 해석 및 실험 결과 비교

  • 류헌열;임현승;조시형;황병준;이성호;박진구
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2012년도 춘계학술발표대회
    • /
    • pp.81.2-81.2
    • /
    • 2012
  • To fabricate a metal mold for injection molding, hot-embossing and imprinting process, mechanical machining, electro discharge machining (EDM), electrochemical machining (ECM), laser process and wet etching ($FeCl_3$ process) have been widely used. However it is hard to get precise structure with these processes. Electrochemical etching has been also employed to fabricate a micro structure in metal mold. A through mask electrochemical micro machining (TMEMM) is one of the electrochemical etching processes which can obtain finely precise structure. In this process, many parameters such as current density, process time, temperature of electrolyte and distance between electrodes should be controlled. Therefore, it is difficult to predict the result because it has low reliability and reproducibility. To improve it, we investigated this process numerically and experimentally. To search the relation between processing parameters and the results, we used finite element simulation and the commercial finite element method (FEM) software ANSYS was used to analyze the electric field. In this study, it was supposed that the anodic dissolution process is predicted depending on the current density which is one of major parameters with finite element method. In experiment, we used stainless steel (SS304) substrate with various sized square and circular array patterns as an anode and copper (Cu) plate as a cathode. A mixture of $H_2SO_4$, $H_3PO_4$ and DIW was used as an electrolyte. After electrochemical etching process, we compared the results of experiment and simulation. As a result, we got the current distribution in the electrolyte and line profile of current density of the patterns from simulation. And etching profile and surface morphologies were characterized by 3D-profiler(${\mu}$-surf, Nanofocus, Germany) and FE-SEM(S-4800, Hitachi, Japan) measurement. From comparison of these data, it was confirmed that current distribution and line profile of the patterns from simulation are similar to surface morphology and etching profile of the sample from the process, respectively. Then we concluded that current density is more concentrated at the edge of pattern and the depth of etched area is proportional to current density.

  • PDF

전류펄스 인가된 T자형 Mg 합금 시편의 온도 구배 변화 (Thermal Gradient Change of T-shaped Mg Alloy Specimen Exposed to Electropulses)

  • 송종한;박동준;천세호;유진영;이성호;이태경
    • 소성∙가공
    • /
    • 제33권4호
    • /
    • pp.285-290
    • /
    • 2024
  • Electropulsing treatment (EPT) has been developed as an alternative to furnace heat treatment (FHT) to exploit its engineering advantages in rapidly annealing metallic materials. Conventionally, the separation of thermal and athermal effects of EPT has been attempted by comparing EPT and FHT specimens processed under identical temperature and duration. However, this method inherently introduces experimental and measurement errors. This study proposes a novel approach to distinguish the thermal and athermal effects of EPT-processed metals using T-shaped specimen with two observation points, namely 'C' and 'D'. For verification, the thermal gradient of T-shaped Mg alloys was examined under various EPT conditions. The points C exhibited higher temperatures compared to those at points D at a given electric current density, because only the former received both thermal and athermal effects. It was confirmed from twelve specimens that the point C at an electric current density of 65 A·mm-2 and point D at 70 A·mm-2 exhibited similar temperatures. This developed method is expected to reduce measurement errors in distinguishing thermal and athermal effects, thus providing a deeper understanding of their quantitative contributions in future studies.