• 제목/요약/키워드: Current Circuit Breaker

검색결과 370건 처리시간 0.025초

초전도한류기의 계통도입을 위한 경제적 타당성 검토 (A Economic feasibility of Superconducting Fault Current Limiter in Korean Power System)

  • 김종율;이승렬;윤재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.421-423
    • /
    • 2004
  • As power system grows more complex and power demands increase, the fault current tends to gradually increase. In the near future, the fault current will exceed a circuit breaker rating for some substations, which is an especially important issue in the Seoul metropolitan area because of its highly meshed configuration. Currently, the Korean power system is regulated by changing the 154kV system configuration from a loop connection to a radial system, by splitting the bus where load balance can be achieved, and by upgrading the circuit breaker rating. A development project applying 154kV Superconducting Fault Current Limiter(SFCL) to 154kV transmission systems is proceeding with implementation slated for after 2010. In this paper, the expected price of SFCL in order to assure the economic feasibility is evaluated comparing with upgrading cost of ciui.1 breakers. The results show that the SFCL should be developed under seven times of price of circuit breaker to be competitive against upgrading circuit breakers.

  • PDF

Weil-Dobke 합성단락시험로의 최적화 연구 (A Study on Optimization of the Weil-Dobkes Synthetic Short-Circuit Tests)

  • 김맹현;고희석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권6호
    • /
    • pp.287-292
    • /
    • 2001
  • This paper deals with the configuration, operating principles, systematic calculation method of parameter and optimization method of test circuit for parallel current injection method, series voltage injection method and hybrid synthetic test method as the method for performance test of circuit breaker with extra high interrupting capacity. The test method depicted above is applied to short-circuit making and breaking test (operating sequence :Os CdOs, Od-CdOs) and out-of-phase tests(operating sequence :Os, CdOs) for performance test of the newly-developed 420kV, 50kA and 800kV 50kV puffer-type gas circuit-breaker according to IEC 60056 and IEC 60427. The testing results, evaluation of equivalence for test and analyzed results are also presented in this paper.

  • PDF

저압차단기기의 보호협조 (The Protective Co-ordination between Low-Voltage Circuit-Breaker)

  • 박성찬;오준식;이방욱;유만종;서정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.340-343
    • /
    • 2001
  • In an electrical network, electrical power are transmitted by a various of protection, isolation and control electric circuit devices. This thesis deals with the protection function between circuit-breakers. The protective coordination concerns the behaviour of two devices placed in series in an electrical network, with a short-circuit downstream circuit-breaker. It has two basic principles: First, discrimination which is an increasing requirement of low voltage electrical distribution systems. Second, which is less well known: cascading, which consists of installing a device, whose breaking capacity is less than the three-phase short-circuit current at its terminals and helped by main circuit-breaker. The important advantage of cascading is to be able to install at a branch circuit-breaker of a lesser performance without endangering the safety of the installation for more economical usage. To determine and guarantee co-ordination between two circuit breakers, it is necessary to carry out a theoretical approach, first, and then confirm the results by means of standard tests. This is illustrated in appendix A of IEC 947-2.

  • PDF

저항형초전도한류기 과도특성을 고려한 EMTDC 모델개발 (Development of EMTDC model for Resistance type Fault Current Limiter considering transient characteristic)

  • 윤재영;김종율;이승렬
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.1-7
    • /
    • 2003
  • Nowadays, one of the serious problems in KEPCO(Korea Electric Power Co-Operation) system is the more higher fault current than the SCC(Short Circuit Capacity) of circuit breaker. There are many alternatives to reduce the increased fault current such as isolations of bus ties, enhancement of SCC of circuit breaker, applications of HVDC-BTB(High Voltage Direct Current-Back to Back) and FCL(fault current limiter). But, these alternatives have some drawbacks in viewpoints of system stability and cost. As the superconductivity technology has been developed, the HTS-FCL(High Temperature Superconductor -Fault Current Limiter) can be one of the attractive alternatives to solve the fault current problem. Under this background, this paper presents the EMTDC(Electro-Magnetic Transient Direct Current) model for resistance type HTS-FCL considering the nonlinear characteristic of final resistance value when quenching phenomena occur.

전기적 노이즈에 의한 누전차단기의 오동작에 관한 실험적 연구 (An Empirical Study on Malfunction of the Earth Leakage Circuit Breaker)

  • 김태만;권용준;기도형
    • 한국안전학회지
    • /
    • 제17권1호
    • /
    • pp.45-53
    • /
    • 2002
  • The purpose of this study was to investigate effect of electrical noise on malfunction of the earth leakage circuit breaker. A three-way experiment for studying its malfunction was conducted, in which electrical products such as radio, alternating current are welder and cellular phone, distance from the earth leakage breaker to electrical products, and whether or not the earth leakage breaker is contained is contained in the steel box were employed as experimental variables. Eleven earth leakage breakers frequently used in real situations were tested in each experimental treatment. The electrical products were used for generating electrical noise that is known to be able to cause malfunction of the earth leakage breaker. The results showed that except a case for one of the 11 earth leakage breakers when the radio made by M company was located 30 cm ahead of the breaker, malfunction did not occur in any other experimental treatment. Consequently, it is suggested that the breaker should be normally used for preventing electricity-related accidents without fear of its malfunction in industrial sites.

초고압 SF6 가스 차단기 투입 시 아크접촉자 내전압 특성 연구 (Analysis of Withstand Voltage between Arc Contacts of High Voltage SF6 Gas Circuit Breaker n Making Operation)

  • 김인길;이주현;정형수;박재윤
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.601-605
    • /
    • 2012
  • The non-controlled closing of High-voltage SF6 gas circuit breaker can cause transient current and overvoltage in the field. The controlled closing technology is an effective way to reduce transient current and voltage, prevent equipment failures, and improve power quality. For the development of controlled closing, it is obviously necessary to determine the withstand voltage between arc contacts of High-voltage SF6 gas circuit breaker in making operation. This paper focuses on decrease of pressure and density of SF6 gas that can affect withstand voltage between arc contacts in making operation. The dielectric strength between arc contacts could be improved by minimizing the decrement of pressure and density of SF6 gas obtained by simulation and test and moreover the rate of decrease of dielectric strength (RDDS) of arc contacts could be foreseen.

SF6 가스절연 개페장치 일 (A Study on the Interrupting Capability of the Fault Current in the E.H.V. Transmission System.)

  • 강길건
    • 대한전기학회논문지
    • /
    • 제40권1호
    • /
    • pp.18-23
    • /
    • 1991
  • Recently SLAMECKA suggested the mathematical dynamic arc model of the SF6 gas circuit breaker [1]. The author applied the above dynamic arc model to the E.H.V. transmission line and investigated the interrupting capability of the SF6 gas circuit breaker. In particular the Runge-Kutta-England numerical method suitable for the use in systems that involve nonlinear dynamic arc and traveling wave was used by converting the current source into the voltage source in the DOMMEL's method [2]. The successful computer resultls were obtained and it was found that the arc time constant and the second derivative of the arc conductance are closely related to the interrupting capability of the SF6 gas circuit breaker.

  • PDF

72.5kV 20kA 전철용 가스차단기의 압력상승 측정 및 소전류 차단성능해석 (Pressure-Rise Measurement and Analysis of Low Current Interruption Capability of a 72.5kV 20kA Gas Circuit Breaker for Electrical Railway System)

  • 송기동;박경엽;정진교;오연호;민길식;박기엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.164-166
    • /
    • 1998
  • This paper presents the results of the measured pressure-rise and the analyzed results of the cold gas flow-field in a 72.5kV 20kA gas circuit breaker for the electrical railway system. The analysis of cold gas flow field and the calculation of electric field strength have been performed in 3 types of interrupters and the low current interruption capability has been estimated for each of the gas circuit breaker considering the opening speed, the nozzle shape and the stroke length.

  • PDF

분로 리액터용 개폐제어 차단기의 최적 개폐시점 선정 (Determination of Optimal Controlled Switching Instants for Circuit Breaker of Shunt Reactors)

  • 이우영;박경엽;정진교;김희진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권12호
    • /
    • pp.664-669
    • /
    • 2002
  • In this paper the method to determine tire optimal switching instants in order to reduce the transient surges during switching not relevant to the neutral treatment of shunt reactors is presented. This method consists of the following two steps. First, the instants of the voltage peaks between the contacts of each poles and the voltage magnitude as well as the moments of the current zero crosses were found out analytically. Next, the instants of the contact touches or separations were determined in consideration of the rate of decrease of dielectric strength or a circuit breaker and the variation of the its operating time. The results obtained from the EMTP(Electromagnetic Transient Program) analysis studies show that the making instants are established at the peak voltage of each three poles for any conditions of a neutral point and the possible upper limited values of inrush currents due to the variation of the mechanical operating time can be estimated.

Simple Analysis Method for the Interrupting Capability of a Contact System in a Molded Case Circuit Breaker

  • Choi, Young-Kil;Jee, Seung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1257-1261
    • /
    • 2017
  • This paper focuses on understanding the interrupting capability of an arc contact system in a molded case circuit breaker (hereafter MCCB). We selected four types of MCCBs and analyzed the magnetic flux density distributions in the contact systems caused by the fault currents. We ascertained that the magnetic flux density profile varies according to the shape of the contact system and was asymmetric at both the ends of an arc, perpendicular to the arc column because of the magnetic grid installed in the contact system. The asymmetric difference creates a magnetic force that pushes the arc current outwards and provides an interrupting capability. We have introduced a simple analysis method for determining the interrupting capability of the contact system for an MCCB by the arc-driving magnetic flux density.