• Title/Summary/Keyword: Cumulative Dose Measurement Range

Search Result 3, Processing Time 0.019 seconds

Development of Mixed Sensor Parts for Integrated Radiation Exposure Protection Fireman's Life-saving Alarm (일체형 방사선 피폭 방호 소방관 인명구조 경보기의 혼합형 센서부 개발)

  • Kim, Jae-Hyeong;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1457-1460
    • /
    • 2019
  • In this paper, we proposed the development of a mixed sensor parts for integrated radiation exposure protection fireman's life-saving alarm that can be location-tracked and irradiated. To measure radiation exposure dose, we use the PIN-Diode radiation measurement sensor module, a semi-conductive radiation measurement sensor that can minimize size and weight. The design for removing leakage current is carried out to enhance the characteristics of the radiation measurement sensor using PIN-Diode. The IMU sensor module is used to estimate the location of the current fireman at the same time as the accident estimate by adding together the data and the values for acceleration on the three axis. Experiments were conductied by an authorized testing agency to determine the efficiency of the proposed mixed sensor parts for integrated radiation exposure protection fireman's life-saving alarms. The cumulative dose measurement range was measured in the range of 10 μSv to 10 mSv, the highest level in the world. The accuracy was measured from ±6.3% to ±9.0% (137 Cs) and normal operation was found at the international standard of ±15%. In addition, positional accuracy was measured within ±10%, resulting in a high level of results, demonstrating its effectiveness. Therefore, it is expected that more firemen will be able to provide with superior performance integrated radiation exposure protection fireman life-saving alarm.

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.

The relationships between lead exposure indicies and urinary δ-ALA by HPLC and colorimetric method in lead exposure workers (연노출근로자에 있어서 흡광광도법과 HPLC법에 의한 요중 δ-ALA 배설량과 연노출지표들 간의 관련성)

  • Ahn, Kyu-Dong;Lee, Sung-Soo;Hwangbo, Young;Lee, Gab-Soo;Yeon, You-Yong;Kim, Yong-Bae;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.77-87
    • /
    • 1996
  • In order to compare the difference of the measurement of delta aminolevulinic acid(${\delta}$-ALA) in urine between HPLC method(HALA) and colorimetric method(CALA), and also to provide useful information for the new diagnostic criteria of ${\delta}$-ALA in urine in lead poisoning, if at all possible in the future, authors studied 234 male lead workers who were selected from 7 storage battery factories, 3 secondary smelting industries, and 2 litharge making industries. Study subjects were selected on the basis of blood Zinc protoporphyrin(ZPP) level from low to high concentration to cover wide range of lead exposure. Study variables for this study were ${\delta}$-ALA measured by two different methods, blood lead(PbB), and blood ZPP. The results were as follows: 1. There was very high correlation between ${\delta}$-ALA measured by two method(r = 0.989 : HALA = -0.8194 + 0.8110 ${\times}$ CALA), but the value of CALA was measured about 2mg/L greater than HALA. 2. While the correlations of ${\delta}$-ALA by two method with blood lead and blood ZPP were 0.46 and 0.37 respectively, they were increased to 0.63 and 0.57 if ${\delta}$-ALA values were log-transformed. 3. Simple linear regression of ${\delta}$-ALA measured by two method on ZPP were as follows: CALA = 2.0421 + 0.0341 ${\times}$ ZPP ($R^2=0.1385$ p = 0.0001) HALA = 0.8006 + 0.0280 ${\times}$ ZPP ($R^2=0.1389$ p = 0.0001) 4. Simple linear regression of ${\delta}$-ALA measured by two method on PbB were as follows: CALA = - 0.4134 + 0.1545 ${\times}$ PbB ($R^2=0.2085$ p = 0.0001) HALA = -1.2893 + 0.1287 PbB ($R^2=0.2154$ p = 0.0001), 5. Simple linear regression of log-transformed ${\delta}$-ALA by two method on ZPP and PbB were as follows: logHALA = 0.3078 + 0.0060 ZPP ($R^2=0.3329$ p = 0.0001) logCALA = 1.0189 + 0.0044 ZPP ($R^2=0.3290$ p = 0.0001) logHALA = -0.0221 + 0.0246 PbB ($R^2=0.4046$ p = 0.0001) logCALA = 0.7662 + 0.0184 PbB ($R^2=0.4108$ p = 0.0001) 6. The cumulative percent of colorimetric method to detect lead workers whose value of PbS and ZPP were over screening level such as $40{\mu}/dl$ and $100{\mu}/dl$ respectively was higher than HPLC method if cut-off level of ${\delta}$-ALA for screening of lead poisoning was 5 mg/L. But if cut-off level of ${\delta}$-ALA measured by HPLC was reduced to 3 mg/L which is compatible to 5 mg/L of ${\delta}$-ALA measured by colorimetric method, there were good agreement between two methods and showed dose-response relationship with other lead exposure indices such as PbB and ZPP.

  • PDF