• Title/Summary/Keyword: CuAg

Search Result 1,191, Processing Time 0.031 seconds

Recent progress in the synthesis of luminescent copper clusters

  • Zhou, Shaochen;Wang, Fu;Wang, Chuanyi
    • Advances in nano research
    • /
    • v.4 no.2
    • /
    • pp.113-128
    • /
    • 2016
  • Luminescent metallic clusters have attracted great interest due to their unique optical, electronic and chemical features. Comparing with intensively studied Au and Ag Clusters, Cu clusters are superior in the aspects of cost and wide industrial demanding. However, tiny copper clusters are extremely prone to aggregate and undergo susceptibility of oxidation, thereby the synthesis of fluorescent zero valent copper clusters is rather challenging. In this review, synthetic strategies towards luminescent copper clusters, including macromolecule-protection and micro molecule-capping, have been systematically surveyed. Both "bottom-up" and "top-down" synthetic routes are found to be effective in fabricating luminescent copper clusters, some of which are quite stable and possess decent luminescence quantum yields. In general, the synthesis of fluorescent copper clusters remains at its infant stage. A great deal of effort on developing novel and economic synthetic routes to produce bright and stable copper clusters is highly expected in future.

Healthcare IoT: DNA Watch (헬스케어 IoT: DNA 시계)

  • Kim, Jeong Su;Lee, Moon Ho;Park, Daechul
    • Journal of Engineering Education Research
    • /
    • v.21 no.3
    • /
    • pp.66-75
    • /
    • 2018
  • This paper is the second part of the January 2018 issue of the Korean Society for Engineering Education, The "Equilibrium and Unbalance Analysis of Taegeuk Pattern DNA Matrix Codes," and is an extension of the paper published in the IoT Section of the 2017 Summer Conference in Jeju. In this paper, we have reviewed the history of what is life, and 5G Mobile communication: with IoT followed by recent research on influenza RNA gene mutation and DNA mutation variants, and the insights of Watson and Crick. Inspired by a single Franklin DNA X-ray diffraction photograph, they received the Nobel Prize for the Nature publication of DNA that has three patterns and regular repeatability. Professor MoonHo Lee has solved the three patterns in Diagonal, Left to Right, and Vertical matrices in a 2x2 matrix[CU; AG] and A = T = U = 30% C = G = 20%. We also proposed DNA Watch. This is the Healthcare IoT, which is seen by the DNA Watch on the wrist, the type of Tai Chi pattern of the body, and is immediately connected to the smartphone and delivered to the doctor.

Solder Joints Fatigue Life of BGA Package with OSP and ENIG Surface Finish (OSP와 ENIG 표면처리에 따른 BGA 패키지의 무연솔더 접합부 피로수명)

  • Oh, Chulmin;Park, Nochang;Hong, Wonsik
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.2
    • /
    • pp.80-87
    • /
    • 2008
  • Many researches related to the reliability of Pb-free solder joints with PCB (printed circuit board) surface finish under thermal or vibration stresses are in progress, because the electronics is operating in hash environment. Therefore, it is necessary to assess Pb-free solder joints life with PCB surface finish under thermal and mechanical stresses. We have investigated 4-points bending fatigue lifetime of Pb-free solder joints with OSP (organic solderability preservative) and ENIG (electroless nickel and immersion gold) surface finish. To predict the bending fatigue life of Sn-3.0Ag-0.5Cu solder joints, we use the test coupons mounted 192 BGA (ball grid array) package to be added the thermal stress by conducting thermal shock test, 500, 1,000, 1,500 and 2,000 cycles, respectively. An 4-point bending test is performed in force controlling mode. It is considered that as a failure when the resistance of daisy-chain circuit of test coupons reaches more than $1,000{\Omega}$. Finally, we obtained the solder joints fatigue life with OSP and ENIG surface finish using by Weibull probability distribution.

A COMPARATIVE STUDY ON THE CHEMICAL COMPOSITION AND MECHANICAL PROPERTIES OF FOUR LOW-GOLD-CONTENT DENTAL CASTING ALLOYS MANUFACTURED IN KOREA (한국산(韓國産) 치과주조용(齒科鑄造用) 저금함유합금(低金含有合金)의 조성(組成) 및 기계적(機械的) 성질(性質)에 관(關)한 비교연구(比較硏究))

  • Chang, Ik-Tae;Yang, Jae-Ho;Kim, Chang-Whe;Kim, Kwang-Nam;Lee, Sun-Hyung;Kim, Yung-Soo;Chang, Wan-Shik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.17-27
    • /
    • 1981
  • This study was conducted to determine the chemical composition and the mechanical properties of four commercially available low gold-based crown and bridge alloy produced in Korea. Four dental casting gold-silver-palladium alloys, i.e., A, B, C and D (code of alloys) were selected for the evaluation of chemical composition, ultimate tensile strength, elongation. values and Vickers hardness. The chemical composition of test specimens was analyzed by both emission spectrography and wet gravitation method with a 1.5gm of low gold ingot. The tensile properties and Vickers hardness was determined with cast specimens treated in following three conditions; as-cast, softening heat treatment and hardening heat treatment. The tensile testing bars were cast in accordance with the model designed by Gettleman and Harrison (1969) which was modified from the A. D. A. Specification No. 14 for dental chromium-cobalt casting alloy. Nine tensile test specimens were made from a split silicone mold for each of the test alloys to the size of 2.5mm in diameter and a gauge length of 10mm. All four alloys were handled in accordance with conventional methods used in Type III gold alloys. Ultimate tensile strength and elongation were measured on an Instron Universal Tensile Testing Machine (Model 1125, Japan) operated at a crosshead rate of 0.1cm/min. Elongation values were measured using Digital Measuring Microscope (MS-152, FUSOH, Japan). Vickers hardness was determined with a Vickers Hardness Tester (Model VKH-l, Japan) at a 1.0kg load on a mounted tensile test specimen. The following results were obtained from this study; 1. All tested alloys were composed of Au, Ag, Pd, Cu, Zn and Fe in common. The composition rate of gold for all four alloys was found in the range of $42{\sim}47$ weight % as shown below. Alloy A; Au 45%, Ag 40.2%, Pd 5.76%, others 9.04%. Alloy B; Au 47.1%, Ag 29.03%, Pd 6.98%, others 16.92%. Alloy C; Au 45%, .Ag 26.9%, Pd 6.83%, others 21.07%. Alloy D; Au 41.8%, Ag 34.4%, Pd 6.95%, others 16.85%. 3. The ultimate tensile strength of the four alloys was in the range of $31{\sim}82kg/mm^2$. The test results were shown in the below order from the highest value; As-cast condition; D, B, C, A. Softening heat treament; B, C, D, A. Hardening heat treatment; D, B, C, A. 4. The test :results of the elongation rate for each alloy were in the range of $0.5{\sim}18%$. The test results were shown in the below order from the highest value; As-cast condition; A, D, B, C. Softening heat treatment; A, C, D, B. Hardening heat treatment; C, D, B, A. 5. Vickers hardness for each of the four alloys was in the range of $120{\sim}230$. The test results were shown in the below order from the highest value; As-cast condition; C, B, D, A Softening heat treatment; D, B, C, A. Hardening heat treatment; D, A, C, B. 6. There were no differences in the physical properties between as-cast condition and softening heat treatment.

  • PDF

Dielectric and Piezoelectric Properties of $(K_{0.5}Na_{0.5})_{0.97}(Nb_{0.96}Sb_{0.04})O_3$ Ceramics according to $CeMnO_3$-Substitiution ($CeMnO_3$ 치환에 따른 $(K_{0.5}Na_{0.5})_{0.97}(Nb_{0.96}Sb_{0.04})O_3$ 세라믹스의 유전 및 압 전 특성)

  • Oh, Young-Kwang;Seo, Byoung-Ho;Yoo, Ju-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.306-306
    • /
    • 2010
  • 21 세기는 언제, 어디에서, 누구나가 정보를 자유롭게 염가에 이용할 수 있는 유비쿼터스 정보사회가 될 것으로 예상하고 있다. 이러한 유비쿼터스 사회가 실현되기 위해서는 필연적으로 대두되고 있는 과제가 에너지 공급원의 문제이다. 휴대용 전자제품이나 소형 에너지 공급원으로 지금까지 주로 전지가 사용되어 왔지만 이것들은 교환 및 충전이 불가피하다. 이러한 불편함을 개선하기위해 교환과 충전이 불필요하거나 아주 장시간동안 공급해주는 형태의 에너지 공급원의 필요성이 대두되고 있다. 이러한 에너지 공급원으로 최근에 많은 연구가 되고 있는 것이 주위의 환경으로부터 버려지는 에너지를 수확(harvesting)하여 전력으로 변환하는 에너지 하베스팅 (energy harvesting)기술이 연구 개발되고 있다. 에너지 하베스팅 응용을 위해서 사용되어지는 압전 세라믹스는 전압출력계수 ($g_{33}$)가 커야하는데 이것은 압전상수 ($d_{33}$)와 유전상수 (${\varepsilon}_{\tau}$)의 값에 영향을 받는 것으로 알려져있다. 그 중에서 우수한 전기적 특성 때문에 PZT를 기반으로 하는 압전 세라믹스가 사용되어져왔다. 그러나 Pb의 높은 유독성과 Pb를 포함하는 제품들의 처분문제들로 인해 제조에 관한 많은 문제점들을 지니고있다. 그리하여, Pb를 포함하지 않는 Pb-free계에 관한 연구가 전세계적으로 활발히 진행되고 있다. 다양한 Pb-free계 후보자들 가운데 $K_{0.5}Na_{0.5}NbO_3$ (KNN)는 높은 큐리온도와 좋은 강유전 특성 및 압전특성 때문에 PZT를 대체할 가장 장래성있는 대안들 중의 하나로 고려되고 있다. 그러나 고온에서 알칼라인 원소들의 높은 휘발성 때문에 보통의 소결공정으로는 소결이 잘되고 치밀한 세라믹스를 얻기가 어렵다. 많은 연구에서 KNN 세라믹스의 소결성을 개선하기 위하여 강유전 또는 반강유전체인 $SrTiP_3$$LiTaO_3$를 고용체 형성에 포함시키고 또한 $K_4CuNb_8O_{23}$, $MnO_2$, CuO등과 같은 소결조제를 첨가하여 압전 특성과 소결성을 개선시켰다. 따라서 본 연구에서는 비화학양론적 (1-X)[$[(K_{0.5}Na_{0.5}]_{0.97}(Nb_{0.96}Sb_{0.04})O_3]$ + 0.008CuO + 0.2wt% $Ag_2O$ + X $CeMnO_3$의 조성을 사용하여 A사이트와 B 사이트에 각각 Ce이온과 Mn 이온의 치환량을 변화하여 그에 따른 유전 및 압전특성을 조사하였다.

  • PDF

Comparison of Blood Metal Concentration in Ohjeok-san(Wuji-san) Treated Rats - Dose-Response Relationship and Mechanism - (오적산을 투여한 흰쥐의 혈액중 금속농도 비교에 관한 연구 - 용량-반응관계와 기전을 중심으로 -)

  • 이정렬;이선동
    • The Journal of Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.67-82
    • /
    • 2002
  • Objectives: In recent years, extensive focus has been laid on adulteration of herbal medicine with heavy metals. This may be mainly due to soil contamination by environmental pollution. The objective of this study is to identify the contents of various heavy metals in the blood from Ohjeok-san (Wuji-san) Decoction (OD) treated-rats. Methods: For this study, 13 kinds of metals including essential and heavy metals, i.e. A1, As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Se and Zn were analyzed by a slight modification of EP A methods and the following results are obtained. Results: 1. There was no significant difference between the OD-treated groups and control group in liver, kidney, bone, brain and weight, especially no significant difference at the 5th and 10th days in weight and the amount of food intake. 2. The amount of each metal analyzed in the blood were as follows; A1: 2.3~3.07 mg/l, As: 2.90~3.66 mg/l, Cd: 0~0.001 mg/l, Co: 0~0.01 mg/l, Cr: 0.40~043 mg/l, Cu: 0.93~1.88 mg/l, Fe: 414.35~464.46 mg/l, Hg: 0.01 mg/l, Mn: 0.10~0.17 mg/l, Ni: 0.01 mg/l, Pb: 0.03~012 mg/l, Se: 0.73 mg/l, Zn: 3.41~4.13 mg/l by groups, respectively. In control and experimental group, Experimental I and other experimental II, III, IV, and V groups, there were no significant differences. 3. The amount of non-toxic metals (A1, Co, Cu, Fe, Mn, Se, Zn) were $64.1{\pm}7.71{\;}mg/l$ in the control group and 60.70~67.58 mg/l in the experimental groups I, II, III, IV and V. The amount of Toxic metals (As, Cd, Cr, Ag, Pb) were $0.68{\pm}0.21{\;}mg/l$ in the control group and 0.57 ~ 0.66mg/l in the experimental groups. The total amount of metals were 32.35 mg/l in the control group and 30.48~34.12 mg/l in the test groups I, II, III, IV and V, respectively. Conclusions: There was no significant difference of metal concentration in the blood from the OD-treated-rats compared to those of the control group even if higher dosage (1~8 times the dosage for a person) of OD was administered. This may be mainly due to a decoction treatment which contains only supernatants filtered from the herb-mass after boiling. This indicates the legal limitation for metal concentration in herbal medicine must be applied according to different treatment methods of herbal medicine.

  • PDF

Geochemical Occurrence Characteristics of Geogenic Heavy Metals in Korea Evaluated Using Geochemical Map Data (전국 지화학도 자료를 이용한 지질기원 중금속의 지화학적 발생특성)

  • Ahn, Joo Sung;Youm, Seung-Jun;Cho, Yong-Chan;Yim, Gil-Jae;Ji, Sang-Woo;Lee, Jung-Hwa;Lee, Pyeong-Koo;Lee, Jeong-Ho;Shin, Seong-Cheon
    • Economic and Environmental Geology
    • /
    • v.55 no.4
    • /
    • pp.339-352
    • /
    • 2022
  • As environmental criteria items are increased or strengthened, cases of heavy metal contamination by geogenic origin are increasing, and the need to distinguish between natural and anthropogenic origins in soil or groundwater exceeding the standard is increasing. In this study, geochemical occurrences of geogenic heavy metals were identified through statistical processing of the national geochemical map data and evaluation of geochemical characteristics of regions with high geoaccumulation indices. Cobalt, Cr, Cu, Ni, Pb, V, and Zn were targeted for which the national geochemical maps were prepared, and Co, Cr, Ni, and V derived from ultrabasic or ultramafic rocks were classified as factor 1. Copper, Pb and Zn of non-ferrous sulfide origin were classified as factor 2. In particular, enrichment of heavy metals by factor 1 occurs mainly in the serpentine distribution areas of the Chungcheong region, and there is a risk of contamination in neighboring areas. In the case of factor 2, geogenic occurrence is concerned not only in non-ferrous metal mineralization areas such as Taebacksan and Gyeongnam mineralization zones, but also in Au-Ag mineralization areas distributed nationwide.

Environmental effects from Natural Waters Contaminated with Acid Mine Drainage in the Abandoned Backun Mine Area (백운 폐광산의 방치된 폐석으로 인한 주변 수계의 환경적 영향)

  • 전서령;정재일;김대현
    • Economic and Environmental Geology
    • /
    • v.35 no.4
    • /
    • pp.325-337
    • /
    • 2002
  • We examined the contamination of stream water and stream sediments by heavy metal elements with respect to distance from the abandoned Backun Au-Ag-Cu mine. High contents of heavy metals (Pb, Zn, Cu, Cd, Mn, and Fe) and aluminum in the waters connected with mining and associated deposits (dumps, tailings) reduce water quality. In the mining area, Ca and SO$_4$ are predominant cation and anion. The mining water is Ca-SO$_4$ type and is enriched in heavy metals resulted from the weathering of sulfide minerals. This mine drainage water is weakly acid or neutral (pH; 6.5-7.1) because of neutralizing effect by other alkali and alkaline earth elements. The effluent from the mine adit is also weakly acid or neutral, and contains elevated concentrations of most elements due to reactions with ore and gangue minerals in the deposit. The concentration of ions in the Backun mining water is high in the mine adit drainage water and steeply decreased award to down stream. Buffering process can be reasonably considered as a partial natural control of pollution, since the ion concentration becomes lower and the pH value becomes neutralized. In order to evaluate mobility and bioavailability of metals, sequential extraction was used for stream sediments into five operationally defined groups: exchangeable, bound to carbonates, bound to FeMn oxide, bound to organic matter, and residual. The residual fraction was the most abundant pool for Cu(2l-92%), Zn(28-89%) and Pb(23-94%). Almost sediments are low concentrated with Cd(2.7-52.8 mg/kg) than any other elements. But Cd dominate with non stable fraction (68-97%). Upper stream sediments are contaminated with Pb, and down area sediments are enriched with Zn. It is indicate high mobility of Zn and Cd.

Correlation of Arsenic and Heavy Metals in Paddy Soils and Rice Crops around the Munmyung Au-Ag Mines (문명 금은광산 주변 논토양에서 As 및 중금속의 토양과 벼작물의 상관성 평가)

  • Kwon, Ji Cheol;Park, Hyun-Jung;Jung, Myung Chae
    • Economic and Environmental Geology
    • /
    • v.48 no.4
    • /
    • pp.337-349
    • /
    • 2015
  • This study has focused on investigation of correlation for As and heavy metals in paddy soil and rice crops sampled in the vicinity of the abandoned Munmyung Au-Ag mine. Soil samples extracted by various methods including aqua regia, 1 M $MgCl_2$, 0.01 M $CaCl_2$ and 0.05 M EDTA were analyzed for As and heavy metals (Cd, Cu, Pb and Zn). Rice grain samples grown on the soils were also analyzed for the same elements to evaluate the relationships between soils and rice crops. According to soil extraction methods, As and heavy metal contents in the soils were decreased in the order of aqua regia > 0.01 M $CaCl_2$ > 1 M $MgCl_2$ > 0.05 M EDTA. In addition to correlation analysis, statistically significant correlation with the four extraction methods (p<0.01) were found in the soil and rice samples. As calculation of biological accumulation coefficients (BACs) of the rice crops for As and heavy metals, the BACs for Cd, Zn and Cu were relatively higher than those for As and Pb. This study also carried out a stepwise multiple linear regression analysis to identify the dominant factors influencing metal extraction rates of the paddy soils. Furthermore, daily intakes of As and heavy metals from regularly consumed the rice grain (287 g/day) grown on the contaminated soils by the mining activities were estimated, and found that Cd and As intakes from the rice reached up to 73.7% and 51.8% for maximum allowance levels of trace elements suggested by WHO, respectively. Therefore, long-term consumption of the rice poses potential health problems to residents around the mine, although no adverse health effects have yet been observed.

Studies on the Cellulase produced by Myriococcum of albomyces (Myriococcum albomyces가 생산하는 Cellulase에 관한 연구)

  • Chung, Dong-Hyo
    • Applied Biological Chemistry
    • /
    • v.14 no.1
    • /
    • pp.59-97
    • /
    • 1971
  • As a study on the cellulase of Myriococcum albomyces the culture media for enzyme formation and properties of its crude preparation were investigated and the crude enzyme preparation was further fractionated. The results are summarized as follows: 1. Wheat bran solid culture produced stronger activities of cellulase than rice bran or defatted soy bean meal solid culture. 2. Shaking culture with wheat bran, rice bran or defatted soy bean meal produced higher cellulase activities than solid culture with the corresponding media. 3. The enzyme formation was higher at $45^{\circ}C$ than at $37^{\circ}C$ or $50^{\circ}C$ regardless of the kind of culture medium. 4. The formation of CMCase activity was more promoted by organic nitrogen source than inorganic nitrogen source. 5. The formation of cellulase activities were increased 1.5 to 3.0-fold by adding CMC, Avicel or cellulose powder as an inducer into 5% wheat bran basal medium. 6. Cellulase production using a tank culture procedure with addition of CMC or Avicel as an inducer was the highest at fifth day and thereafter decreased slightly. 7. The crude enzyme preparation showed pH optimum in 4.0 to 4.5, and pH stability in the range of 3.5 to 8.0. Optimum temperature for the activity was $65^{\circ}C$ which was higher than among other cellulases and it was stable at $60^{\circ}C$ for 120 minutes. 8. Dialyzed crude enzyme was activated by $Ca^{++}$ and $Mg^{++}$, but inhibited by $Hg^{++}$, $Cu^{++}$ and $Ag^{+}$. 9. Four different types of cellulase, i. e., fraction I, fraction II-a, fraction II-b, and fraction III were purified from the culture filtrate of Myriococcum albomyces through a sequence of ammonium sulfate fractionation, and elution chromatography on DEAE-Sephadex A-25, Amberlite CG-25 type 2 and hydroxyapatite columns. 10. These four cellulase fractions were showed to be homogenous by electrophoresis and ultracentrifugation and also gave a typical ultraviolet absorption spectrum of protein. 11. Four purified fraction showed different specificity toward substrates, fraction I has a stronger activity toward Avicel, cellulose powder, and gauze than that of other cellulase fractions. Fraction II-a had a powerful activity toward cellobiose but it was almost inactive agaisnt fibrous cellulose contrary to fraction I. On the contrary, the main component fraction II-b had a fairly higher activity on CMC and Avicel. Activity of fraction II-b toward cellobiose was about one-third of that of fraction II-a and activity on Avicel was lower than that of fraction I. Fraction III had a more powerful activity in decreasing viscosity of CMC. 12. Final hydrolysis products of fibrous cellulose by each fraction were cellobiose and glucose. Whereas oligosaccharides were predominant in the early stage of hydrolysis, prolonged reaction produced more glucose than cellobiose. Fraction I and fraction II-a acted synergically on Avicel. 13. Optimum pH for the activities of cellulase fraction I, fraction II-a, fraction II-b and fraction III were found to be 5.5, 5.0, 4.0 and $4.0{\sim}4.5$, respectively. These fractions were found to be stable in the range of pH $3.0{\sim}7.5$. 14. Optimum temperature for the activities of fraction I, fraction II-a, fraction II-b, and fraction III were $50^{\circ}C$, $55^{\circ}C$, $60^{\circ}C$ and $55^{\circ}C$, respectively. No less of activity was found by heating 120 minutes at $55^{\circ}C$ and fraction II-a was more stable than the others at $60^{\circ}C$. 15. Fraction I and fraction II-b were activated by $Ca^{++}$ and $Mg^{++}$ but inhibited by $Hg^{++}$ and $Ag^{+}$.

  • PDF