• Title/Summary/Keyword: Cu-equivalent image

Search Result 9, Processing Time 0.025 seconds

Assessment of the Measurement Method of the Bone Mineral Density on Cu-Equivalent Image (구리당량 영상작성에 의한 골밀도계측방법의 평가)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.30 no.2
    • /
    • pp.101-108
    • /
    • 2000
  • Purpose : The effects of step numbers of copper wedge and exposure on the coefficient of determination (r²) of the conversion equation to Cu-equivalent image and on the Cu-equivalent value (mmCu) and it's coefficient of variation measured at each copper step and the mandibular premolar area were evaluated. Method: Digital image analyzing system consisted of scanner, personal computer, and a stepwedge with 10 steps of 0.03 mm copper in thickness as reference material was prepared for quantitative assessment of the bone mineral density. NIH image program was used for analyzing images. Results : The film having moderately high film density showed the discrepancy between the real thickness and the measured Cu-equivalent value of each copper step. The Cu-equivalent image was dependent on the determinational coefficient of the conversion equation than the coefficient of variance of the measured value. Conclusion : Obtaining conversion equation with high coefficient of determination and proper film exposure are supposed to be neccessary for quantitative assessment of bone density. Multiple steps in the range of the corresponding copper thickness to the bone density of the area to be measured should be prepared.

  • PDF

The Assessment on the Characteristics of Quantitative Image in Digora$\textregistered$ (Digora$\textregistered$에서 정량영상의 특성에 대한 평가)

  • Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.397-405
    • /
    • 1999
  • Purpose: To clarify the usefulness and the limitation of Digora system/sup (R)/ by evaluating the physical characteristics as the quantitative image on Image Plate(Ip). Materials and Methods: Radiograms were taken by Heliodent MD(Siemens Co.. Germany) with the image plate for adult. Cu-step wedge as reference material. and three pieces of dry mandibular bone. Image analysis was performed by single color enhancement. density measurement with histogram. The relationship between the exposure conditions and the distribution of the pixel values of the image. the variation of pixel values of each step of Cu-step wedge at two different area and Cu-equivalent value of three pieces of dry mandibular bone measure by the conversion equation. Results: There was no linear relationship between the exposure condition and the average pixel value of the image. of which the distribution was not even. The pixel value differences between the center portion and the periphery were ranged from 60 to 70 in vertical plane and from 15 to 26 in horizontal plane. Two plot profile formed at two different areas of the Cu-step wedge were different. The measured Cu-equivalent values showed the discrepancy among the times of measurement. Conclusion: As above results. Image Plate(Ip) of Digora system/sup (R)/ showed the limitation as the quantitative image. The physical property of IP was expected to need to be compensated for the quantitative evaluation of the bone or others

  • PDF

The determination of reference material for bone density by using bone phantom (골판톰을 이용한 골밀도측정 참조체의 결정)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.135-139
    • /
    • 2002
  • Purpose: To determine the proper reference step wedge for digital Cu-Equivalent Image analyzing systems for measurement of bone density. Meterials and Methods : Radiograms of lumbar vertebrae phantom (1g/㎠) with 3 test copper step wedges of 0.03, 0.05 and, 0.1 mm thickness unit were taken and analyzed using NIH image software on a Macintosh personal computer. Measured densities of the lumbar areas in the Cu-Equivalent images made by utilizing 3 different copper stepwedges were compared with a known bone density. Results: The values of r2 for all copper equivalent images were over 0.99. The mean Cu-Eq value of lumbar in copper equivalent image made by a 0.1 mm copper stepwedge was 0.22 ± 0.06 mm and converted to hydroxyapatite density of 1.03 g/㎠. The stepwedges of 0.03 and 0.05 mm produced results having higher values than the actual known bone density. They did not show the blue and green color level that appeared in lumbar on color enhanced image. Conclusion : A copper stepwedge of adequate thickness and range of steps which can express the range of density of bone being measured should be used.

  • PDF

Evaluation of Bone Change by Digital Subtraction Radiography after Implantation of Tooth Ash-plaster Mixture (치아회분과 석고혼합제제 매식후 Digital Subtraction Radiography에 의한 골량 변화의 평가)

  • Kim Jae-Duk;Kim Kwang-Won;Cho Yaung-Gon;Kim Dong-Kie;Choi Eui-Hwan
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.423-433
    • /
    • 1999
  • Purpose : To assess the methods for the clinical evaluation of the longitudinal bone changes after implantation of tooth ash-plaster mixture into the defect area of human jaws. Materials and methods : Tooth ash-plaster mixtures were implanted into the defects of 8 human jaws. 48 intraoral radiograms taken with copper step wedge as reference at soon, 1st, 2nd, 4th, and 6th week after implantation of mixture were used. X-ray taking was standardized by using Rinn XCP device customized directly to the individual dentition with resin bite block. The images inputted by Quick scanner were digitized and analyzed by NIH image program. Cu­equivalent values were measured at the implanted sites from the periodic digital images. Analysis was performed by the bidirectional subtraction with color enhancement and the surface plot of resliced contiguous image. The obtained results by the two methods were compared with Cu­equivalent value changes. Results : The average determination coefficient of Cu-equivalent equations was 0.9988 and the coefficient of variation of measured Cu values ranged from 0.08~0.10. The coefficient of variation of Cu-equivalent values measured at the areas of the mixture and the bone by the conversion equation ranged from 0.06 ~0.09. The analyzed results by the bidirectional subtraction with color enhancement were coincident with the changes of Cu-equivalent values. The surface plot of the resliced contiguous image showed the three dimensional view of the longitudinal bone changes on one image and also coincident with Cu-equivalent value changes after implantation. Conclusion : The bidirectional subtraction with color enhancement and the surface plot of the resliced contiguous image was very effective and reasonable to analyze clinically and qualitatively the longitudinal bone change. These methods are expected to be applicable to the non-destructive test in other fields.

  • PDF

An Assessment on Cu-Equivalent Image of Digital Intraoral Radiography (디지털구내방사선사진의 구리당량화상에 대한 평가)

  • KIM JAE-DUK
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.33-42
    • /
    • 1999
  • Geometrically standardized dental radiographs were taken. We prepared Digital Cu-Equivalent Image Analyzing System for quantitative assessment of mandible bone. Images of radiographs were digitized by means of Quick scanner and personal Mcquintosh computer. NIH image as software was used for analyzing images. A stepwedge composed of 10 steps of 0.1mm copper foil in thickness was used for reference material. This study evaluated the effects of step numbers of copper wedge adopted for calculating equation. kVp and exposure time on the coefficient of determination(r²)of the equation for conversion to Cu-equivalent image and the coefficient of variation and Cu-Eq value(mm) measured at each copper step and alveolar bone of the mandible. The results were as follows: 1. The coefficients of determination(r²) of 10 conversion equations ranged from 0.9996 to 0.9973(mean=0.9988) under 70kVp and 0.16 sec. exposure. The equation showed the highest r was Y=4.75614612-0.06300524x +0.00032367x² -0.00000060x³. 2. The value of r² became lower when the equation was calculated from the copper stepwedge including 1.0mm step. In case of including 0mm step for calculation. the value of r showed variability. 3. The coefficient of variation showed 0.11, 0.20 respectively at each copper step of 0.2, 0.1mm in thickness. Those of the other steps to 0.9 mm ranged from 0.06 to 0.09 in mean value. 4. The mean Cu-Eq value of alveolar bone was 0.14±0.02mm under optimal exposure. The values were lower than the mean under the exposures over 0.20sec. in 60kVp and over 0.16sec. in 70kVp. 5. Under the exposure condition of 60kVp 0.16sec.. the coefficient of variation showed 0.03. 0.05 respectively at each copper-step of 0.3, 0.2mm in thickness. The value of r² showed over 0.9991 from both 9 and 10 steps of copper. The Cu-Eq value and the coefficient of variation was 0.14±0.01mm and 0.07 at alveolar bone respectively. In summary. A clinical application of this system seemed to be useful for assessment of quantitative assessment of alveolar provided high coefficient of determination is obtained by the modified adoption of copper step numbers and the low coefficient of variation for the range of Cu-Equivalent value of alveolar bone from optimal kVp and exposure time for each x-ray machine.

  • PDF

The correlationship between mandibular radiomorphometric indices in panorama and bone mineral density in Cu-equivalent image of intraoral film (파노라마방사선사진에서 골형태 계측과 구내표준필름에서 구리당량치의 상관관계)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.33 no.3
    • /
    • pp.131-135
    • /
    • 2003
  • Purpose: To determine whether the mandibular radiomorphometric indices in panoramic radiography are correlated with the bone mineral density of Cu-equivalent images in intraoral film. Materials and Methods: The bone mineral density (BMD) of the mandibular premolar area was measured in the Cu-equivalent image of intraoral film. The Panoramic Mandibular Index (PMI) and Mandibular Cortical Width (MCW) were measured in panoramic radiographs of six dry mandibles, and the Pearson correlation between PMI, MCW, and BMD were tested. Results: There were no significant correlations between PMI and BMD (r = 0.280), nor between MCW and BMD (r =0.237). Conclusion: The results show that PMI and MCW were poor diagnostic indicators of mandibular BMD in the six dry mandibles used in this study. The correlationship between the mandibular radiomorphometric indices (PMI and MCW) and mandibular BMD needs to be researched further using large in vivo patient samples.

  • PDF

An Assessment of Image Analysis of Longitudinal Bone Changes (시간경과에 따른 골변화의 영상 분석에 관한 연구)

  • Kim Young-Jin;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.73-86
    • /
    • 1997
  • This study was performed to assess the analyzing methods developed to detect clinically and quantitatively longitudinal bone changes. Through preliminary experiment, accuracy of Cu-Eq value conversion to the mass of HA was examined. For main experiment, 15 intraoral radiograms taken at soon, 1st, 2nd, 4th, and 6th week after implantation of mixture in extracted sites of 3 cases were used. We took the radiograms with copper step wedge as test object and HA phantom X -ray taking was standardized by using Rinn XCP device customized directly to the individual dentition with resin bite block. The images inputted by Quick scanner into computer were digitized and analyzed by NIH image program. The stability of the copper equivalent transformation and the usefulness of two analyzing methods by ROI and Reslice were examined. Obtained results as follows: 1) On the Cu equivalent images, the coefficient of variation in the measurement of Cu-Eq. value of ROI ranged from 0.05 to 0.24 and showed high reproducibility. 2) All results obtained by resliced contiguous image were coincident with those obtained from the assessment by ROI and formation of plot profile. 3) On the stacked and resliced image at the line of interest, we could analyze directly and quantitatively the longitudinal changes at several portions by plot profile and qualitatively by surface plot. 4) Implant area showed marked resorption till 2 weeks after implantation and showed significant increase in Cu-Eq. value at 6th week(p<0.01) and periapical area showed increase in Cu-Eq. value at 6th week compared to after-operation's.

  • PDF

Assessment of Cancellous Bone of Mandible by Multifunctional Panoramic X-Ray Machine (다기능 파노라마 방사선촬영장치를 이용한 하악해면골질의 평가)

  • Ko Jae-Kyung;Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.30 no.1
    • /
    • pp.16-22
    • /
    • 2000
  • Purpose : To evaluate the bone densities measured on copper-equivalent image of cross sectional view of mandibular edentulous premolar area obtained by multifuctional panoramic x-ray machine, PM 2002 CC with transversal slicing system. Materials and Methods: Panoramic cross sectional views with 8 mm focal layer of aluminum step and blocks, of hydroxyapatite (RA) step, 6 HA blocks and copper step wedge having 0.03 mm thickness of each step, and of 3 bone blocks cutted by 8 mm thickness mesiodistally and a dry mandible with copper step wedge were taken by using transversal slicing system in PM 2002 Cc. All reference-equivalent images were made and analyzed by NIH image program. Results: The average copper-equivalent value of cancellous bone of bone blocks on the panoramic cross sectional view was 0.026 ± 0.020 mm Cu. The calculated average bone density was 0.38g/cm². There was no significant difference (P>0.1) between the bone densities on intraoral digital view and on the panoramic digital cross sectional view. Conclusion: The copper-equivalent image of panoramic digital cross sectional view obtained by PM 2002 CC with very thin copper step wedge was supposed to be useful to measure the bone density of cancellous bone of mandible at the premolar edentulous area.

  • PDF

The Effect of Aloe, Gelfoam, Plaster on Bone Formation in Applying to the Bone Defect (Aloe, Gelfoam, Plaster가 골결손부의 신생골 형성에 미치는 영향에 관한 실험적 연구)

  • Choi Eui-Hwan;Kim Su-Gwan
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.493-505
    • /
    • 1999
  • Purpose: This study was to evaluate the effects of Aloe. Gelfoam. and Plaster of Paris on bone healing. Materials and Methods: Four experimental defects were created for placement of the three materials in the right femur of dogs. One defect served as an empty control site. The evaluation was performed at 1-. 6-. and 12-weeks by light microscopy and radiographs. Results: Radiographic and histologic examinations showed new bone formation in the presence of Aloe, Gelfoam. and Plaster of Paris and similar bone healing reactions. Conclusion: On the basis of these findings, it was concluded that Aloe, Gelfoam. and Plaster of Paris may be adequate agents for use in bone procurement.

  • PDF