• Title/Summary/Keyword: Cu filter

Search Result 173, Processing Time 0.028 seconds

A Study on the Characteristics and Utilization of Ash from ASR Incinerator (ASR 소각재의 이화학적 물성 및 재활용(再活用)을 위한 기초연구(基礎硏究))

  • Lee, Hwa-Young
    • Resources Recycling
    • /
    • v.16 no.2 s.76
    • /
    • pp.32-39
    • /
    • 2007
  • The measurement of physicochemical properties of ASR incineration ash has been carried dot and the preparation of light-weight material has also been performed using ASR ash for recycling point of view as building or construction materials. For this aim, chemical composition, particle size distribution, and heavy metal leachability were examined for 2 bottom ashes and 4 fly ashes obtained from the domestic ASR incinerator. In the present work, attempt has been made to prepare the lightweight material using boiler ash as a raw material, which is prepared by forming the mixture of boiler ash, lightweisht filler and inorganic binder and followed by calcination at elevated temperature. As a result, the content of Cu in bottom ash was as high as about 3wt% so that the recovery of Cu from ash was required. The major compound of SDR #5 and Bag filter #6 was found to be $CaCl_2{\cdot}Ca(OH)_2{\cdot}H_2O\;and\;CaCl_2{\cdot}4H_2O$, respectively. It is thought that heavy metal teachability of lightweight material prepared with boiler ash was significantly decreased due to the encapsulation or stabilization of heavy metal compounds.

A Study on Image Quality and Exposure Dose of Hard-radiation Radiography of the Chest (흉부(胸部) 경선질촬영(硬線質撮影)에 있어서 피폭선양(被曝線量)의 저감(低減)에 관(關)한 연구(硏究))

  • Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakurai, Tatsuya;Kim, Chung-Woon;Hwang, Jong-Sun
    • Journal of radiological science and technology
    • /
    • v.14 no.2
    • /
    • pp.15-21
    • /
    • 1991
  • Experiment was conducted on the image quality and exposure dose following replacement of $CaWO_4$ system screen BH-III and BX-III which have so far been used for high-voltage hard-radiation quality radiography, with rare earth system screen KO750, combined with high contrast film SRH, while additional filter was altered, Cu 0.8 mm+Al 1.4 mm(HVL : Al 8.8 mm), Cu 1.3 mm+Al 1.0 mm(HVL : Al 10.6 mm) and Cu 1.8 mm+Al 1.5 mm(HVL : Al 11.4 mm). AS a result, visual evaluation did not detect extreme changes in image quality under the respective condition(HVL : $Al\;8.8\;mm{\sim}Al\;11.4\;mm$). It was noted, however, that surface exposure dose declined with an increase in the thickness of the additional filter, as it was $18.9\;{\mu}Gy$ at HVL Al 8.8 mm, $17.5\;{\mu}Gy$ at Al 10.6 mm and $15.7\;{\mu}Gy$ at Al 11.4 mm. Considering the limited rating of X-ray equipment and wear of machinery, however, the range of $Cu\;1.3\;mm{\sim}1.8\;mm+Al\;1.0\;mm{\sim}1.5\;mm(1/16\;VL{\sim}1/32\;VL)$ seemed to be a limit.

  • PDF

Optimization of Energy Modulation Filter for Dual Energy CBCT Using Geant4 Monte-Carlo Simulation

  • Ju, Eun Bin;Ahn, So Hyun;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.125-130
    • /
    • 2016
  • Dual energy computed tomography (DECT) is used to classify two materials and quantify the mass density of each material in the human body. An energy modulation filter based DECT could acquire two images, which are generated by the low- and high-energy photon spectra, in one scan, with one tube and detector. In the case of DECT using the energy modulation filter, the filter should perform the optimization process for the type of materials and thicknesses for generating two photon spectra. In this study, Geant4 Monte-Carlo simulation toolkit was used to execute the optimization process for determining the property of the energy modulation filter. In the process, various materials used for the energy modulation filter are copper (Cu, $8.96g/cm^3$), niobium (Nb, $8.57g/cm^3$), stannum (Sn, $7.31g/cm^3$), gold (Au, $19.32g/cm^3$), and lead (Pb, $11.34g/cm^3$). The thickness of the modulation filter varied from 0.1 mm to 1.0 mm. To evaluate the overlap region of the low- and high-energy spectrum, Geant4 Monte-Carlo simulation is used. The variation of the photon flux and the mean energy of photon spectrum that passes through the energy modulation filter are evaluated. In the primary photon spectrum of 80 kVp, the optimal modulation filter is a 0.1 mm lead filter that can acquire the same mean energy of 140 kVp photon spectrum. The lead filter of 0.1 mm based dual energy CBCT is required to increase the tube current 4.37 times than the original tube current owing to the 77.1% attenuation in the filter.

Experimental fabrication of tapped band pass filter of $BiNbO_{4}$ ceramics ($BiNbO_4$ 세라믹스를 이용한 태핑기법의 적층칩 대역 필터에 관한 연구)

  • 고상기;지기만;김경용
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.4
    • /
    • pp.988-996
    • /
    • 1998
  • BN ceramics with 0.07wt% $V_{2}O_{5}$ and 0.03wt% CuO(BNC3V7) sintered at $900^{\circ}C$ where it is possible for these to be co-fired with Ag electrode. Dielectricconstant of 44.3, TCF of 22 ppm$/^{\circ}C$ and $Qxf_{o}$ value of 22,000 GHz can be obtained from BNC3V7, multilayer type band pass filters using tapped method and conventional method were designed for PCS (Personal Communication System) applications. Tapped method by adopting input/output-tapping scheme the chip filter stucture becomes simpler and needs fewer layers than that using the conventional input/output-coupling scheme. A multilayer type band pass filter fabricated by screen-printing with silver electrode after tape casting. The simulated characteristics of the fabricated filters sintered at $900^{\circ}C$ were compared with the designed ones. Even though the centered frequencies of tapped and conventional band pass chaip filters were measured to shift about 90MHz downward, the band pass characteristics of both filters were similar that of designed ones. The spuriousresonance characteristic of tapped pass chip filter was better than that of conventional chip filer.

  • PDF

A Study on the Removal of SOx and NOx Using Catalytic Ceramic Filters (촉매담지 세라믹 필터를 이용한 황산화물과 질소산화물의 제거에 관한 연구)

  • 홍민선;이동섭
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.455-464
    • /
    • 1998
  • Removal teals of Soxmox were performed using low density ceramic filters doped with various catalysts. Disc type (50 mmO.Dx10 mmt) low density ceramic filters were doped with three different catalysts such as Cu to remove SOx and NOx, and Mn and Co to remove NOx. The air permeabilities and specific surface areas were 40~50cc/min.cm2.cmH2O and 4.1~8.88 m2/g, respectively. Also, the peak pore sizes of catalyst support were 3~5nm. Tests were focused to search optimum operating temperatures for different catalysts. It was found that as the CuO content increases, SOx removal efficiency was increased. NOx removal efficiencies for Mn, Cu and Co, were 85% at 30$0^{\circ}C$, 90% at 40$0^{\circ}C$ and 90% at 45$0^{\circ}C$, respectively.

  • PDF

Comparison of Pollutant Removal Efficiency in Road Sediment with Media Using Filter Separator (필터 분리기를 이용한 여재별 도로퇴적물의 오염물질 제거효율 비교)

  • Bang, Ki-Woong;Lee, Jun-Ho;Choi, Chang-Su;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.332-340
    • /
    • 2007
  • Storm runoff from road contains significant loads of particulate and dissolved solids, organic constituents and metal elements. Micro particle is important when considering pollution mitigation because pollutant metal and organics have similar behavior with particles. The objective of this research is to evaluate the hydrodynamic filter separator performance for road storm runoff treatment. A various types of media such as perlite, granular activated carbon, zeolite were used for column test packing media and filter separator, and to determine the removal efficiency with various surface loading rate. As the results of column test, the highest SS removal efficiency was using mixed media(granular activated carbon, zeolite and perlite), and granular activated carbon mixed with zeolite has higher heavy metal removal efficiency than perlite. In laboratory scale hydrodynamic filter separator study, the operation ranges of surface loading rates were from 192 to 1,469 $m^3/m^2/day$. The estimated overall removal efficiencies of hydrodynamic filter separator for typical storm runoff were SS 48.1%, BOD 31.9%, COD 32.6%, TN 15.5%, and TP 17.3%, respectively. For the case of heavy metals, overall removal efficiencies were Fe 26.0%, Cu 19.4%, Cr 25.7, Zn 16.6%, and Pb 15.0%, respectively. The most appropriate medium for hydrodynamic filter separator was perlite mixed with granular activated carbon to treatment of road storm runoff.

Design and Fabrication of Strip Line Chip Filter for Mobile Communication (이동통신용 strip line 적층 칩 필터 설계 및 제작)

  • Yoon, Jung-Rag;Kim, Jee-Gyun;Lee, Seog-Won;Lee, Heun-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.838-840
    • /
    • 1998
  • $BiNbO_4$ ceramics with 0.06wt% CuO, 0.1wt% $V_{2}O_{5}$ sintered at $900^{\circ}C$. The strip line chip filter has been design and fabricated by screen printing with silver electrode after tape casting. The characteristics of the fabricated filters were compared with the simulated results. In the strip line chip filter, insertion loss value of band pass width was 3.65[dB] and return loss was 8.9[dB] and center frequency was similar that simulation results.

  • PDF

Yellowing of Chemical Pulp by Glucuronoxylan

  • Kim, Young-Seok;Yoon, Byung-Ho
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.3 s.116
    • /
    • pp.23-28
    • /
    • 2006
  • Xylan in hemicellulose has been reported as one of the reasons of the yellowing of chemical pulp and paper. But little relevant information is available in literature. In this study, we examined into the influence that glucuronoxylan or glucomannan and metallic ion($Cu^{2+},\;Fe^{2+},\;Fe^{3+},\;Mn^{2+}$) residued in pulp get each or when mixed at yellowing. Filter paper was treated with each metallic ion, glucuronoxylan and the mixture of glucuronoxylan and metal ions, and brightness and CIE $L^*a^*b^*$ was measured after accelerated aging. As the results of measurements, the filter paper processed by 10% glucuronoxylan was dropped $2{\sim}3%$ on the brightness after accelerated aging for 24 hours. Also, the filter paper treated with glucuronoxylan and $Fe^{2+}$ was dropped 7% on the brightness.

Some Measurements of Scattered Radiation from Various Radiation Shielding Materials (방사선(放射線) 차폐물질(遮蔽物質)에서 발생(發生)하는 산란선(散亂線)의 측정(測定))

  • Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.15-22
    • /
    • 1981
  • Half value layer(radiation energy) of $90^{\circ}$ scattered radiation from various radiation shielding materials was measured at 1 m distance from the central ray of the primary beam. Scattered radiation was measured from 100 to 200 kVp for 0-2.0mm Cu+1.0mm Al added filter in the primary beam for a deep therapeutic unit, the obtained results were as follows: 1. The ratio of scattered radiation to primary radiation was increased by using lighter filter. 2. The ratio of scattered radiation to primary radiation was decreased by using heavier filter. 3. The ratio of scattered radiation to primary radiation was independent of tube voltage. 4. The scattered radiation of high energy was produced, when the effective atomic number and density of shielding material were high.

  • PDF