• 제목/요약/키워드: Cu filter

Search Result 173, Processing Time 0.024 seconds

Enhancement of Image Quality Using Detector Filter (검출기 필터를 이용한 화질의 향상)

  • Lim, Jong-Nam;Kim, Hyung-Tae;Kim, Min-Hye;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.451-456
    • /
    • 2016
  • Radiation dose to patient is unavoidable when diagnosis is carried out using X-ray. Radiation diagnosis using dual energy X-ray was examined to verify the possibility of medical applications by SNR and image scoring. The dual energy X-ray was realized by combining together two image plates and filter of 0.5 mm thick Cu or Al. Under one X-ray exposure, contrast enhanced image was obtained using two images of image plates. The enhanced image showed higher SNR and image score compared to the first image which was the image recorded with the first image plate. The dual energy X-ray technique would be a very useful method for obtaining higher SNR image and for realizing very low dose, and could be applied to medical applications.

A Study on the Early-stage Storm Runoff Treatment for the Reduction of Non-point Pollution Materials on the Road (도로상의 비점오염물질 저감을 위한 초기 우수유출수 처리에 관한 연구)

  • Roh, Sung-Duk;Lee, Dae-Keun;Chun, Yang-Kun
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.525-533
    • /
    • 2004
  • The object ofthis study was to test for STORMSYS process that composed Catch Basin and Stormsys(three units: vortex solids separator, filter media bed and vegetated filter strips). It could be applied to treat the first-flush non-point pollution materials on the road(especially, motorway). This study investigated that the runoff characteristics of non-point pollutions containing the heavy metal(Fe, Zn and Cu) by rainfall showed relatively high pollution concentration in the early-stage storm runoff on the road, which seems to be caused by the vehicular traffic, and showed the rapid reduction of pollution concentration on the basis of about 5mm rainfall volume. As the number of the non-rainy days were increased, the pollution concentration by storm runoff was increased, also. As a test result of this process, the average removal efficiency of BOD, $COD_{mn}$, SS, T-N and T-P over the testing period were 92.7%,88.6%,97.4%,93.0% and 93.3%, respectively. Also, the average removal efficiency of n-Hexane, Fe, Zn and Cu were 86.7%, 96.1%, 84.4% and 78.4%, respectively. As shown in the characteristics of storm runoff, the non-point pollution materials have high pollution concentration in the early-stage storm runoff on the road, the installation of STORMSYS process is expected to reduce considerable amount of non-point pollutions.

Microstructure of Aluminum Can Body Alloys produced by Recycled UBC and Virgin Aluminum (폐알루미늄캔과 신지금으로 제조된 캔용 알루미늄 합금의 미세조직)

  • Lim Cha-Yang;Kang Seuk-Bong
    • Resources Recycling
    • /
    • v.11 no.6
    • /
    • pp.31-37
    • /
    • 2002
  • Microstructure of aluminum alloys produced by the different mixing ratio of secondary ingot made by aluminum UBC (used beverage can) and virgin aluminum was investigated. The phase transitions of casted ingot by heat treatment were also studied. The alloys were melted at the electric resistance furnace, then casted using ceramic filter. Homogenization heat treatment was conducted at $615^{\circ}C$ for 10hrs to control cast microstructure. There were several kinds of phases, in as-cast condition, such as $\alpha$($Al_{12}$ $((Fe,Mn)_3$Si), $\beta$($Al_{6}$ (Fe,Mn)), and fine $Mg_2$Si phases. Especially, the amount of $\beta$-phase which was harmful in forming process was large. The $\beta$-Phase formed was transformed to u-phase by heat treatment. The fine $Mg_2$Si in the aluminum matix was also transformed to $\alpha$-phase by this heat treatment. Impurities filtered during casting process were identified as intermetallic compounds of Fe, Cu, Si.

Development of AAS and Determination of metals in airborne particles (원자흡수분광광도계의 제작 및 분진 중 금속성분 분석 비교)

  • Choi, Bae-Jin;Bang, Myung-Sik;Yeo, In-Hyeong
    • Analytical Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.226-231
    • /
    • 2003
  • We analyzed the concentrations of heavy metals associated airbone particles by using AAS made by both a domestic manufacturer and one of the foreign manufacturer. One model developed by a domestic manufacture showed excellent results in the selected wavelength with an excellent performance of a monochromator. It abandons a big drop except a fine drop to improve reproduction in atomizer, so that no remains should leave. Using the low pass filter we were able to reduce a noise of detection signal. The performance of our equipment was found to be highly compatible with that of a foreign company as we achieved the detection limit of about $0.015{\mu}g/L$ using a standard solution of Au. The PM samples had been collected from by main observation points in 7 areas of Seoul city from 2001 to the spring in 2002. with these PM sample we analyzed the concentrations of Pb, Cu, Mn, Cd, Ni, Fe, Cr, Co, Mg and Al.

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.

Area Efficient Hardware Design for Performance Improvement of SAO (SAO의 성능개선을 위한 저면적 하드웨어 설계)

  • Choi, Jisoo;Ryoo, Kwangki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.2
    • /
    • pp.391-396
    • /
    • 2013
  • In this paper, for HEVC decoding, an SAO hardware design with less processing time and reduced area is proposed. The proposed SAO hardware architecture introduces the design processing $8{\times}8$ CU to reduce the hardware area and uses internal registers to support $64{\times}64$ CU processing. Instead of previous top-down block partitioning, it uses bottom-up block partitioning to minimize the amount of calculation and processing time. As a result of synthesizing the proposed architecture with TSMC $0.18{\mu}m$ library, the gate area is 30.7k and the maximum frequency is 250MHz. The proposed SAO hardware architecture can process the decode of a macroblock in 64 cycles.

Spatial Dose Distribution for Diagnostic X-ray Examination within X-ray Room using the MCNPX Program (MCNPX 프로그램을 통한 일반 X선 검사 시 검사실 내 공간선량분포)

  • Lee, Dong-yeon;Lee, Jin-soo
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.298-306
    • /
    • 2015
  • This study is the material of the additional filter(Cu, Ni, CaWO4, Gd+Ba) being used when the diagnosis X-ray was varied to evaluate the spatial dose distribution accordingly. And it suggest to find a suitable material. Experiments using MCNPX program based on the Monte Carlo simulation method was carried out by selecting the chest and abdomen taken. As a result, each material per dose, the average scatter dose is approximately 62%, 100 cm radius of the point of the simulated body surface exposure dose and 50 cm radius centered on the point average about 47%. It is determined that an Al material is currently available in accordance with the result to be replaced by Cu, Ni material is sufficient. With just the thickness due to the difference in the atomic number and density adjusted to be about one-tenth of the Al it will be suitable.

The effects of the shape of IDT electrode pair on the characteristics of SFIT filter (IDT형의 전극 형태가 SFIT형 필터의 특성에 미치는 영향)

  • You, Il-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2662-2670
    • /
    • 2009
  • The effect of the reflector type for the SAW filter on the characteristics of the slanted finger IDT filter have been studied by computer simulation. The IDT was evaporated by Aluminum-Copper alloy. The design condition was optimized by the phase shift of the SAWfilter for WCDMA. We have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness are $5,000{\AA}$, and the width and the space of reflector are $3.6{\mu}m$ and $2.0{\mu}m$, respectively. Frequency response of the fabricated SFIT filter has the property that the center frequency is about 190MHz and bandwidth at the 3dB is probably 8.2MHz. And we could obtain that the return loss is less then 16dB, the ripple characteristics is probably 4dB and the triple transit echo is less then 18dB after when we have matched impedance.

Fabrication & Characteristics of SIR Microsrip Bandpass Filters using Deposition of High-Tc Superconducting Epitaxial Films (고온 초전도 에피텍셜 박막을 이용한 SIR 마이크로스트립 대역통과 필터의 제작 및 특성연구)

  • Park, Kyung-Kuk;Chung, Dong-Chul;Jeong, Yong-Chae;Lim, Sung-Hun;Yim, Seong-Woo;Han, Byoung-Sung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.5
    • /
    • pp.326-332
    • /
    • 1999
  • In this paper, we designed and fabricated High-Tc Superconducting (HTS) microstrip bandpass filters using Stepped Impedance Resonators(SIR) and studied on their characteristics. The $high-T_c$ superconducting $Y_1Ba_2Cu_3O_{7-x}$ epitaxial films were deposited by Pulse Laser Deposition (PLD) system on MgO. The fabricated filters were designed so as to operate in Ku band with central frequency 17.25 GHz, bandwidth 2.896% and ripple 0.01 dB. These filters were composed of parallel coupled microstrip SIR of which impedance ratio (K) are 0.5, 1.5. In the measured response, HTS filters had showed insertion loss below -0.5 dB. For comparison with normal conducting filter, we fabricated the Au counterpart that consists of the resonators as K=1.5 in the same dimension and measured performance of the Au filter. In comparison, HTS filter designed optimally got superior response to gold conterpart.

  • PDF

Assembly Neutron Moderation System for BNCT Based on a 252Cf Neutron Source

  • Gheisari, Rouhollah;Mohammadi, Habib
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.101-105
    • /
    • 2018
  • In this paper, a neutron moderation system for boron neutron capture therapy (BNCT) based on a $^{252}Cf$ neutron source is proposed. Different materials have been studied in order to produce a high percentage of epithermal neutrons. A moderator with a construction mixture of $AlF_3$ and Al, three reflectors of $Al_2O_3$, BeO, graphite, and seven filters (Bi, Cu, Fe, Pb, Ti, a two-layer filter of Ti+Bi, and a two-layer filter of Ti+Pb) is considered. The MCNPX simulation code has been used to calculate the neutron and gamma flux at the output window of the neutronic system. The results show that the epithermal neutron flux is relatively high for four filters: Ti+Pb, Ti+Bi, Bi, and Ti. However, a layer of Ti cannot reduce the contribution of ${\gamma}$-rays at the output window. Although the neutron spectra filtered by the Ti+Bi and Ti+Pb overlap, a large fraction of neutrons (74.95%) has epithermal energy when the Ti+Pb is used as a filter. However, the percentages of the fast and thermal neutrons are 25% and 0.5%, respectively. The Bi layer provides a relatively low epithermal neutron flux. Moreover, an assembly configuration of 30% $AlF_3+70%$ Al moderator/$Al_2O_3$ reflector/a two-layer filter of Ti+Pb reduces the fast neutron flux at the output port much more than other assembly combinations. In comparison with a recent model suggested by Ghassoun et al., the proposed neutron moderation system provides a higher epithermal flux with a relatively low contamination of gamma rays.