• Title/Summary/Keyword: Ct-parameter

Search Result 140, Processing Time 0.024 seconds

Fabrication of a Brain Model using the Adaptive Slicing Technique (적응단면기법을 이용한 뇌모형제작)

  • Yeom, Sang-Won;Um, Tai-Joon;Joo, Yung-Chul;Kim, Seung-Woo;Kong, Yong-Hae;Chun, In-Gook;Bang, Jae-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.485-490
    • /
    • 2003
  • RP(Rapid Prototyping) has been used in the various industrial applications. This paper presents the optimization techniques fur fabricated 3D model design using RP machine for the medical field. Once the original brain model data are obtained from 2D slices of MRI/CT machine, the data can be modeled as an optimal ellipse. The objective of this study includes optimization of fabrication time and surface roughness using the adaptive slicing method. It can reduce fabrication time without losing surface roughness quality by accumulating the slices with variable thickness. According to the parameter tuning and synthesis of its effect, more suitable parameter values can be obtained by enhanced 3D brain model fabrication. Therefore, accurate 3D brain model fabricated by RP machine can enable a surgeon to perform pre-operation. to make a decision for the operation sequence and to perceive the 3D positions in prototype, before delicate operation of actual surgery.

Research on Perfusion CT in Rabbit Brain Tumor Model (토끼 뇌종양 모델에서의 관류 CT 영상에 관한 연구)

  • Ha, Bon-Chul;Kwak, Byung-Kook;Jung, Ji-Sung;Lim, Cheong-Hwan;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.165-172
    • /
    • 2012
  • We investigated the vascular characteristics of tumors and normal tissue using perfusion CT in the rabbit brain tumor model. The VX2 carcinoma concentration of $1{\times}10^7$ cells/ml(0.1ml) was implanted in the brain of nine New Zealand white rabbits (weight: 2.4kg-3.0kg, mean: 2.6kg). The perfusion CT was scanned when the tumors were grown up to 5mm. The tumor volume and perfusion value were quantitatively analyzed by using commercial workstation (advantage windows workstation, AW, version 4.2, GE, USA). The mean volume of implanted tumors was $316{\pm}181mm^3$, and the biggest and smallest volumes of tumor were 497 $mm^3$ and 195 $mm^3$, respectively. All the implanted tumors in rabbits are single-nodular tumors, and intracranial metastasis was not observed. In the perfusion CT, cerebral blood volume (CBV) were $74.40{\pm}9.63$, $16.08{\pm}0.64$, $15.24{\pm}3.23$ ml/100g in the tumor core, ipsilateral normal brain, and contralateral normal brain, respectively ($p{\leqq}0.05$). In the cerebral blood flow (CBF), there were significant differences between the tumor core and both normal brains ($p{\leqq}0.05$), but no significant differences between ipsilateral and contralateral normal brains ($962.91{\pm}75.96$ vs. $357.82{\pm}12.82$ vs. $323.19{\pm}83.24$ ml/100g/min). In the mean transit time (MTT), there were significant differences between the tumor core and both normal brains ($p{\leqq}0.05$), but no significant differences between ipsilateral and contralateral normal brains ($4.37{\pm}0.19$ vs. $3.02{\pm}0.41$ vs. $2.86{\pm}0.22$ sec). In the permeability surface (PS), there were significant differences among the tumor core, ipsilateral and contralateral normal brains ($47.23{\pm}25.45$ vs. $14.54{\pm}1.60$ vs. $6.81{\pm}4.20$ ml/100g/min)($p{\leqq}0.05$). In the time to peak (TTP) were no significant differences among the tumor core, ipsilateral and contralateral normal brains. In the positive enhancement integral (PEI), there were significant differences among the tumor core, ipsilateral and contralateral brains ($61.56{\pm}16.07$ vs. $12.58{\pm}2.61$ vs. $8.26{\pm}5.55$ ml/100g). ($p{\leqq}0.05$). In the maximum slope of increase (MSI), there were significant differences between the tumor core and both normal brain($p{\leqq}0.05$), but no significant differences between ipsilateral and contralateral normal brains ($13.18{\pm}2.81$ vs. $6.99{\pm}1.73$ vs. $6.41{\pm}1.39$ HU/sec). Additionally, in the maximum slope of decrease (MSD), there were significant differences between the tumor core and contralateral normal brain($p{\leqq}0.05$), but no significant differences between the tumor core and ipsilateral normal brain($4.02{\pm}1.37$ vs. $4.66{\pm}0.83$ vs. $6.47{\pm}1.53$ HU/sec). In conclusion, the VX2 tumors were implanted in the rabbit brain successfully, and stereotactic inoculation method make single-nodular type of tumor that was no metastasis in intracranial, suitable for comparative study between tumors and normal tissues. Therefore, perfusion CT would be a useful diagnostic tool capable of reflecting the vascularity of the tumors.

A Study on the High Temperature Creep Crack Growth Properties for Steam Turbine Rotor Steel under Static and Cyclic Loading Condition (화력 발전용 고압 로터강의 정하중 및 변동하중하의 고온 크립 균열전파 특성에 관한 연구)

  • O, Se-Gyu;Jeong, Sun-Eok
    • Journal of Ocean Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.207-207
    • /
    • 1991
  • The crack length measurements by electrical potential(EP) method for 1% Cr-Mo-V and 12%Cr steel of 0.5T-CT specimen were performed at $500^{\circ}C, 600^{\circ}C 700^{\circ}C$, and an applicability of stress intensity factor($K_I$), net section stress($\sigma_{net}$), $C^*$-ingegral and $C_t$ parameter was studied to measure creep crack growth rate(da/dt) with side groove and without side groove under static and cyclic loading condition. The experimental result could be summarized as follows: 1) Crack measurement by EP method was available and coincided with the Johnson,s analytical equation. 2) da/dt by $K_I$ and $\sigma_{net}$ was not adequate because of the wide scatter band according to load and temperature, but $C^*$-integral, except for transition region, was adequate. 3) $C_t$ parameter showed the best fitted line through total creep region without relating with both temperature and load condition. 4) Under the cyclic loading condition, $C_t$ parameter was proper to extimate da/dt. And it was shown that da/dt for 1% Cr-Mo V steel under the static condition(R=1) was 1.16 times faster than the case under cyclic loading(R=0), and for 12% Cr steel, 1.43 times.

A Study on the High Temperature Creep Crack Growth Properties for Steam Turbine Rotor Steel under Static and Cyclic Loading Condition (화력 발전용 고압 로터강의 정하중 및 변동하중하의 고온 크립 균열전파 특성에 관한 연구)

  • O, Se-Gyu;Jeong, Sun-Eok
    • Journal of Ocean Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.67-75
    • /
    • 1991
  • The crack length measurements by electrical potential(EP) method for 1% Cr-Mo-V and 12%Cr steel of 0.5T-CT specimen were performed at $500^{\circ}C, 600^{\circ}C 700^{\circ}C$, and an applicability of stress intensity factor($K_I$), net section stress($\sigma_{net}$), $C^*$-ingegral and $C_t$ parameter was studied to measure creep crack growth rate(da/dt) with side groove and without side groove under static and cyclic loading condition. The experimental result could be summarized as follows: 1) Crack measurement by EP method was available and coincided with the Johnson, s analytical equation. 2) da/dt by $K_I$ and $\sigma_{net}$ was not adequate because of the wide scatter band according to load and temperature, but $C^*$-integral, except for transition region, was adequate. 3) $C_t$ parameter showed the best fitted line through total creep region without relating with both temperature and load condition. 4) Under the cyclic loading condition, $C_t$ parameter was proper to extimate da/dt. And it was shown that da/dt for 1% Cr-Mo V steel under the static condition(R=1) was 1.16 times faster than the case under cyclic loading(R=0), and for 12% Cr steel, 1.43 times.

  • PDF

Comparative Evaluation of Two-dimensional Radiography and Three Dimensional Computed Tomography Based Dose-volume Parameters for High-dose-rate Intracavitary Brachytherapy of Cervical Cancer: A Prospective Study

  • Madan, Renu;Pathy, Sushmita;Subramani, Vellaiyan;Sharma, Seema;Mohanti, Bidhu Kalyan;Chander, Subhash;Thulkar, Sanjay;Kumar, Lalit;Dadhwal, Vatsla
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4717-4721
    • /
    • 2014
  • Background: Dosimetric comparison of two dimensional (2D) radiography and three-dimensional computed tomography (3D-CT) based dose distributions with high-dose-rate (HDR) intracavitry radiotherapy (ICRT) for carcinoma cervix, in terms of target coverage and doses to bladder and rectum. Materials and Methods: Sixty four sessions of HDR ICRT were performed in 22 patients. External beam radiotherapy to pelvis at a dose of 50 Gray in 27 fractions followed by HDR ICRT, 21 Grays to point A in 3 sessions, one week apart was planned. All patients underwent 2D-orthogonal and 3D-CT simulation for each session. Treatment plans were generated using 2D-orthogonal images and dose prescription was made at point A. 3D plans were generated using 3D-CT images after delineating target volume and organs at risk. Comparative evaluation of 2D and 3D treatment planning was made for each session in terms of target coverage (dose received by 90%, 95% and 100% of the target volume: D90, D95 and D100 respectively) and doses to bladder and rectum: ICRU-38 bladder and rectum point dose in 2D planning and dose to 0.1cc, 1cc, 2cc, 5cc, and 10cc of bladder and rectum in 3D planning. Results: Mean doses received by 100% and 90% of the target volume were $4.24{\pm}0.63$ and $4.9{\pm}0.56$ Gy respectively. Doses received by 0.1cc, 1cc and 2cc volume of bladder were $2.88{\pm}0.72$, $2.5{\pm}0.65$ and $2.2{\pm}0.57$ times more than the ICRU bladder reference point. Similarly, doses received by 0.1cc, 1cc and 2cc of rectum were $1.80{\pm}0.5$, $1.48{\pm}0.41$ and $1.35{\pm}0.37$ times higher than ICRU rectal reference point. Conclusions: Dosimetric comparative evaluation of 2D and 3D CT based treatment planning for the same brachytherapy session demonstrates underestimation of OAR doses and overestimation of target coverage in 2D treatment planning.

Evaluation of the Cause of Internal Jugular Vein Obstruction on Head and Neck Contrast Enhanced 3D MR Angiography Using Contrast Enhanced Computed Tomography (조영증강 전산화단층촬영술을 이용한 두경부 조영증강 삼차원 자기공명혈관촬영술에서 내경정맥 폐쇄의 원인 평가)

  • Gweon, Hye-Mi;Chung, Tae-Sub;Suh, Sang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.41-47
    • /
    • 2011
  • Purpose : To evaluate the cause of internal jugular vein (IJV) obstruction on contrast enhanced 3D MR angiography (CE-MRA) using contrast enhanced computed tomography (CE-CT). Materials and Methods : A total number of 30 patients were enrolled, who underwent both head and neck CE-MRA and CE-CT from 2005 to 2008. We defined obstruction group which had IJV obstruction and control group which had no IJV obstruction on CE-MRA. The following parameters were measured from axial images of CE-CT: 1) diameter of IJV; 2) distance between the styloid process and ipsilateral lateral mass of the atlas; 3) maximum area of lateral mass of the atlas. Each parameter was compared between obstruction group and control group. Results : The diameter of IJV and distance between the styloid process and lateral mass of the atlas at IJV obstruction side in obstruction group were $1.6{\pm}1.0\;mm$ and $4.1{\pm}2.1\;mm$ respectively, which resulted in statistical significance (p<0.01). The maximum area of lateral mass of the atlas at IJV obstruction side in obstruction group was $103.4{\pm}25.3\;mm^2$ which is significantly larger than in control group (p<0.05). Conclusion : We found that the cause of IJV obstruction on CE-MRA could be narrow space between the styloid process and the lateral mass of the atlas, which was related with asymmetric larger area of lateral mass of atlas.

Changes of the liver volume and the Child-Pugh score after high dose hypofractionated radiotherapy in patients with small hepatocellular carcinoma

  • Kim, Young Il;Park, Hee Chul;Lim, Do Hoon;Park, Hyo Jung;Kang, Sang Won;Park, Su Yeon;Kim, Jin Sung;Han, Youngyih;Paik, Seung Woon
    • Radiation Oncology Journal
    • /
    • v.30 no.4
    • /
    • pp.189-196
    • /
    • 2012
  • Purpose: To investigate the safety of high dose hypofractionated radiotherapy (RT) in patients with small hepatocellular carcinoma (HCC) in terms of liver volumetric changes and clinical liver function. Materials and Methods: We retrospectively reviewed 16 patients with small HCC who were treated with high dose hypofractionated RT between 2006 and 2009. The serial changes of the liver volumetric parameter were analyzed from pre-RT and follow-up (FU) computed tomography (CT) scans. We estimated linear time trends of whole liver volume using a linear mixed model. The serial changes of the Child-Pugh (CP) scores were also analyzed in relation to the volumetric changes. Results: Mean pre-RT volume of entire liver was 1,192.2 mL (range, 502.6 to 1,310.2 mL) and mean clinical target volume was 14.7 mL (range, 1.56 to 70.07 mL). Fourteen (87.5%) patients had 4 FU CT sets and 2 (12.5%) patients had 3 FU CT sets. Mean interval between FU CT acquisition was 2.5 months. After considering age, gender and the irradiated liver volume as a fixed effects, the mixed model analysis confirmed that the change in liver volume is not significant throughout the time course of FU periods. Majority of patients had a CP score change less than 2 except in 1 patient who had CP score change more than 3. Conclusion: The high dose hypofractionated RT for small HCC is relatively safe and feasible in terms of liver volumetric changes and clinical liver function.

Impact of Water Quality Parameters on the Disinfection of Total Coliform with Chlorine Dioxide

  • Lee Yoon-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.3
    • /
    • pp.215-221
    • /
    • 2006
  • This study investigated the inactivation of the total coliform, an indicator organism in chlorine dioxide, in order to assess the optimal disinfection procedure for drinking water treatment and distribution systems. This research focus on a number of factors, including the dosage of disinfectant, contact time, pH, temperature and DOC. Water samples were taken from the outlet of a settling basin at a conventional surface water treatment system. As the pH increased in the range of pH 6-9, the bactericidal effects of disinfectants decreased. Changes in levels of pH did not significantly after the disinfection effect of chlorine dioxide for total coliform. With an increase in temperature, there was a subsequent increase in the bactericidal effects of disinfectants. Thus, it is evident that a decrease in temperature will higher the CT values required to inactivate coliform for during the winter. DOC addition can also reduce total coliform inactivation. DOC is the most significant variable in total coliform inactivation with chlorine dioxide.

Fracture Resistance Characteristics of SA516-Gr.70 Steel Plate for RCS Piping Elbow and Support Skirt (원자로 냉각재배관 엘보우 및 서포트 스컷트용)

  • Son, Jong-Dong;Lim, Man-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.4 s.76
    • /
    • pp.49-54
    • /
    • 2006
  • The evaluation of elastic-plastic fracture characteristic was investigated in ferrite steel SA 516- Gr70 used for reactor coolant piping elbow and support skirt of pressure vessels. This paper describes the effect of temperature on J-R curve characteristic of this material. The elastic-plastic fracture mechanics parameter J is obtained with unloading compliance method. The test method were analyzed according to ASTM E 813-89 and E 1152-89. Unloading compliance $J_{IC}$ tests were performed on 1 CT specimens at varied temperatures from $25^{\circ}C$ to about $400^{\circ}C$ using a high temperature extensometer. At all temperature, valid $J_{IC}$ measurements could be made and $J_{IC}$ decreased with increasing temperature. SEM fractography schematically illustrates microvoid initiation, growth and coalescence at the tip of a preexisting crack.

Occlusion-based Direct Volume Rendering for Computed Tomography Image

  • Jung, Younhyun
    • Journal of Multimedia Information System
    • /
    • v.5 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Direct volume rendering (DVR) is an important 3D visualization method for medical images as it depicts the full volumetric data. However, because DVR renders the whole volume, regions of interests (ROIs) such as a tumor that are embedded within the volume maybe occluded from view. Thus, conventional 2D cross-sectional views are still widely used, while the advantages of the DVR are often neglected. In this study, we propose a new visualization algorithm where we augment the 2D slice of interest (SOI) from an image volume with volumetric information derived from the DVR of the same volume. Our occlusion-based DVR augmentation for SOI (ODAS) uses the occlusion information derived from the voxels in front of the SOI to calculate a depth parameter that controls the amount of DVR visibility which is used to provide 3D spatial cues while not impairing the visibility of the SOI. We outline the capabilities of our ODAS and through a variety of computer tomography (CT) medical image examples, compare it to a conventional fusion of the SOI and the clipped DVR.