Spectral CT Analysis of Hounsfield Unit (HU) according to MonoE (keV) and Dilution Ratio of the Contrast Agent: Use of Spectral CT (단색에너지(keV)와 조영제 희석비율 변화에 따른 HU(Hounsfield Unit)값 분석: Spectral CT 이용)

  • Jung, Hee-Ra;Kang, Jin-woo;Kwon, Oh-Jun;Kim, Ho-Jin;Jung, Dabin;Lee, Jae-Hyun;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.669-676
    • /
    • 2020
  • The purpose of this study was to analyze the changes in the values of Hounsfield Unit (HU) according to the changes in monoenergy (keV) and dilution ratio of the contrast agent, using the spectral CT. Spectral CT was used as the testing device, while 20 cc syringe phantom was used to set a total of six dilution ratios of the contrast agent: 8:2, 7:3, 6:4, 5:5, 4:6, and 3:7. Here, the non-ionic iodine solution (350 mg/ml) was used as a contrast agent. The syringe axial image was reconstructed by adjusting the obtained data on nine MonoE levels; 40 keV, 45 keV, 50 keV, 55 keV, 60 keV, 65 keV, 70 keV, 75 keV, and 80 keV. The HU values were measured at the three points of the reconstructed syringe axial image. The measurements were taken 1,620 times in total. In the analysis of the HU values according to the changes in keV and dilution ratio of the contrast agent, the highest and lowest HU values were obtained from dilution ratio 8:2 and dilution ratio 3:7, respectively, across every MonoE in the comparison of HU according to dilution ratio per MonoE (p<0.05), while the highest and lowest HU values were obtained from 40 keV and 80 keV, respectively, across all dilution ratios in the comparison of HU according to MonoE per dilution ratio (p<0.05). For the correlation per each parameter, a negative correlation of -15.014 ± 0.298 was found for HU per keV (R2=0.519) and a negative correlation of -61.372 ± 3.608 was found for HU per dilution ratio (R2=0.152) (p<0.05). To conclude, an increase in keV or dilution ratio of the contrast agent was shown to decrease the HU, and the findings in this study are anticipated to serve as the basic data in the research of HU-related parameters in Spectral CT.

Retrospective study on the airway obstruction aspects of computed tomography and lateral cephalometry and the correlation of polysomnography in obstructive sleep apnea patients

  • Jin, Sun-Mi;Lee, Hye-Sung;Ryu, Hyun-Ho;Ryu, Seok-Hwan;Shin, Dong-Yoon;Kim, Chul-Hoon;Kim, Myoung Soo;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.5
    • /
    • pp.295-304
    • /
    • 2012
  • Objectives: Lateral cephalometry, computed tomography (CT) and full-night polysomnography were used to examine the correlation of obstructive sleep apnea (OSA) severity. Materials and Methods: A total of 29 patients (5 females, 24 males) diagnosed with OSA were evaluated by lateral cephalometry, CT and full-night polysomnography. Lateral cephalometry was performed in the closed and open mouth states. The radiographic and polysomnography measurements of the patients with OSA were evaluated statistically to determine the association with OSA severity. Results: A significant relationship was observed between the increased respiratory disturbance index and closing lateral cephalometry. With mouth opening, the airway space narrowed and the OSA worsened. Lateral cephalometry revealed OSA patients to have an inferiorly positioned hyoid bone, longer-than-normal soft palate and narrowing airway space. As OSA was severe, the airway shape was ovoid in the CT horizontal view. Conclusion: Polysomnography and the radiographic parameter can be used for diagnosing OSA.

A Study on the Behavior of the Plane Stress Fracture Toughness - About the Compact Tension Specimen- (平面應力 破壞靭性値 擧動에 관한 硏究)

  • 송삼홍;고성위
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.937-946
    • /
    • 1986
  • In this paper, the plane stress fracture toughness of low carbon steel with 3mm thickness is investigated for various specimen widths and crack ratios using the J integral. The experiments is carried out for the compact tension(CT) specimen on an Instron machine. For materials that may be approximated by the Ramberg and Osgood stress strain law, the relevant crack parameter like the J integral and load line displacement are approximately normalized. Crack driving forces in terms of J integral is computed using the above estimation scheme. Abtained results are summarized as follows. (1) The plane stress fracture toughness, J$_{c}$, is almost constant in the range 50-70mm of width. Hence J$_{c}$ can be obtained by using smaller specimen than ASTM standard. (2) Yoon's and Simpson's formular which considers crack growth in obtaining J integral show more consevative J than Rice's and Merkle's (3) J$_{c}$ is almost constant in the range 0.499-0.701 crack ratios tested. J$_{c}$ obtained by using Kumar's formular is 28.14kgf/mm for base metal specimen and 32.51kgf/mm for annealed. (4) Comparison of the prediction with actual experimental measurements by Yoon's formular show good agreement for several different-size specimens.

Biomechanical Evaluation of Cement type hip Implants as Conditions of bone Cement and Variations of Stem Design (골시멘트 특성 및 스템 형상에 따른 시멘트 타입 인공관절의 생체역학적 평가)

  • Park, H.S.;Chun, H.J.;Youn, I.C.;Lee, M.K.;Choi, K.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.212-221
    • /
    • 2008
  • The total hip replacement (THR) has been used as the most effective way to restore the function of damaged hip joint. However, various factors have caused some side effects after the THR. Unfortunately, the success of the THR have been decided only by the proficiency of surgeons so far. Hence, It is necessary to find the way to minimize the side effect caused by those factors. The purpose of this study was to suggest the definite data, which can be used to design and choose the optimal hip implant. Using finite element analysis (FEA), the biomechanical condition of bone cement was evaluated. Stress patterns were analyzed in three conditions: cement mantle, procimal femur and stem-cement contact surface. Additionally, micro-motion was analyzed in the stem-cement contact surface. The 3-D femur model was reconstructed from 2-D computerized tomography (CT) images. Raw CT images were preprocessed by image processing technique (i.e. edge detection). In this study, automated edge detection system was created by MATLAB coding for effective and rapid image processing. The 3-D femur model was reconstructed based on anatomical parameters. The stem shape was designed using that parameters. The analysis of the finite element models was performed with the variation of parameters. The biomechanical influence of each parameter was analyzed and derived optimal parameters. Moreover, the results of FE A using commercial stem model (Zimmer's V erSys) were similar to the results of stem model that was used in this study. Through the study, the improved designs and optimal factors for clinical application were suggested. We expect that the results can suggest solutions to minimize various side effects.

Long-Term Analysis for the effect of Ovariectomy on Rat Bone using Micro Finite Element Method (미세 유한요소법을 이용한 난소제거가 쥐뼈에 미치는 영향의 장기간 분석)

  • Ko C.Y;Woo D.G.;Lee T.W.;Kim H.S.;Lee B.Y.;Tack G.R.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.236-239
    • /
    • 2005
  • This study investigated the effect of ovariectomy (OVX) on the rat bone fur long term (22 weeks). In previous researches, there were many studies for morphology of OVX-induced osteoporotic bones based on micro-Computed Tomography (micro-CT). However, there were few studies fpr detecting and tracking changes of mechanical characteristics in the lumbar vertebrae of OVX rat fur long-term. For this study, one female Sprague-Dawley rat was used: an OVX rat. The 4th lumbar of the OVX rat was utilized as a specimen. Morphological characteristics could be investigated fur the lumbar vertebrae in an OVX rat by using in-vivo Micro-CT. An OVX rat was scanned at week 0 (just before surgery), at week 4, at week 8, at week 16 and at week 22 after surgery. Micro finite element $({\mu}FE)$ analysis was used to investigate mechanical characteristics in the lumbar vertebrae for an OVX rat.

  • PDF

The Preoperative Diagnosis of Thyroid Cancer in $^{18}F$-FDG PET/CT Dual Time Imaging of SUV and Evaluation of Radioactivity Measurement (갑상선암 수술 전 진단목적의 $^{18}F$-FDG PET/CT Dual Time Point영상에서 SUV값과 방사능 농도 측정법의 유용성 평가)

  • Lee, Hyun-Kuk;Khang, Hyun Soo;Yang, Seoung-Oh;Han, Man-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose : This study is designed to compare two parameters reflecting $^{18}F$-FDG uptake, SUV and radioactivity, for diagnosis of thyroid cancer in dual time $^{18}F$-FDG PET/CT imaging and to find which parameter is more useful to decide whether the tumor is malignant or not. Materials and Methods : We performed retrospective study for 40 patients. All patients are diagnosed as primary thyroid cancer and examined $^{18}F$-FDG PET/CT. First, we got the dispersion of scattering beam of neck and lung apex to set a background and compared each dispersion, mean value, standard deviation of maxSUV and radioactivity. Also, mean maxSUV, ${\Delta}maxSUV$, ${\Delta}maxBq$/ml(%) and radioactivity between groups according to lesion's size based on biopsy are compared with independent-sample t-test. Results : the values that were from maxSUV and radioactivity measurement technique were compensated and calculated to practical values for mean comparison and patients were divided to two groups based on tumor size, Group1 ($size{\leq}1$ cm, n=21), Group2 (size>1 cm, n=19) for accurate comparison. In Group1, maxSUV (semi-quantitative analysis) was increased from $5.64{\pm}5.85$ (1.89~17.84) at first image to $5.90{\pm}5.01$ (1.95~18.22) at second image and radioactivity (Bq/ml) (quantitative analysis) showed similar increase from $5.93{\pm}6.38$ (2.50~16.75) at first image to $6.01{\pm}5.25$ (2.66~16.58) at second image. In Group2, TFmaxSUV was $10.54{\pm}14.36$ (2.54~33.89) in true first image, TSmaxSUV was $9.85{\pm}12.88$ (2.62~26.20) in true second image separately. The maxSUV showed a significant difference in the mean comparison between the two groups (p=0.035) But, mean radioactivity (Bq/ml) was $5.93{\pm}6.38$ (4.81~40.99) in true first image, $6.01{\pm}5.25$ (4.51~36.93) in true second image and didn't show a significant difference statistically (p=0.126) Conclusion : In diagnosis of thyroid tumor, SUV and radioactivity depending on $^{18}F$-FDG uptake showed high similarity with coefficient of determination (R2=0.939) and malignant evaluation results using dual time also showed similar aspect. Radioactivity for evaluation of malignant tumor didn't show better specificity or sensitivity than maxSUV.

  • PDF

The Clinical Value of Dual Time Point F-18 FDG PET/CT Imaging for the Differentiation of Colonic Focal Uptake Lesions (장관 내 국소 섭취증가 병소의 감별에 있어 추가 지연 F-18 FDG PET/CT의 임상적 유용성)

  • Kim, Jin-Suk;Lim, Seok-Tae;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.309-316
    • /
    • 2009
  • Purpose: F-18 FDG can be accumulated in the liver, bowel, kidney, urinary tract, and muscles physiologically. The aim of this study was to evaluate the clinical value of dual time point 18F-FDG PET /8 imaging for the differentiation of the colonic focal uptake lesions. Materials and Methods: One hundred thirty two patients (M:F = 77:55, Age 62.8$\pm$11.6 years) underwent $^{18}$F-FDG PET/CT at two time points, prospectively: early image at 50-60 min and delayed image at 4-4.5 hours after the intravenous injection of $^{18}$F-FDG. Focally increased uptake lesions on early images but disappeared or shifted on delayed images defined a physiological uptake. For the differential evaluation of persistent focal uptake lesions on delayed images, colonoscopy and histopathologic examination were performed. SUVmax changes between early and delayed images were also compared. Results: Among the 132 patients, 153 lesions of focal colonic uptake were detected on early images of $^{18}$F-FDG PET/CT. Of these, 72 (47.1%) lesions were able to judge with physiological uptake because the focal increased uptake disappeared from delayed image. Among 81 lesions which was showed persistent increased uptake in delayed image, 61 (75.3%) lesions were confirmed as the malignant tumor and 14 (17.3%) lesions were confirmed as the benign lesions including adenoma and inflammatory disease. Remaining 6 (7.4%) lesions were confirmed as the physiological uptake because there was no particular lesion in the colonoscopy. In the malignant lesions, the calculated dual time point change for SUVmax ($\Delta$%SUVmax) was 20.8$\pm$18.7%, indicating a significant increase in SUVmax between the two point (p<0.01). In contrast, the change in SUVmax for the non-malignant lesions including benign lesions and physiological uptake was -13.7%$\pm$24.2%. For the differentiation of the malignant and non-malignant focal colonic uptake lesions, $\Delta$%SUVmax was the most effective parameter, and the cut-off value using -5% provided the best sensitivity, specificity, and accuracy. Conclusion: The dual time point $^{18}$F-FDG PET/CT imaging with SUVmax change evaluation could be an important noninvasive method for the differentiation of malignant and benign focal colonic uptake lesions including physiologic uptake.

Study on the Fatigue Crack Behavior by the Stress Intensity Factor and AE Parameters (응력확대계수와 음향방출 변수를 이용한 피로균열 거동 연구)

  • Yoon, Dong-Jin;Jeong, Jung-Chae;Park, Phi-Lip;Kim, Ki-Bok;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.5
    • /
    • pp.412-423
    • /
    • 2000
  • By using the relation between stress intensity factor and AE parameter, new approach method for assessing the crack length and detectability of crack was proposed. Laboratory experiment was carried out to identify AE characteristics of fatigue cracks for compact tension specimen. The relationship between a stress intensity factor and AE signals activity as well as conventional AE parameter analysis was discussed. As a result, the features of specific parameter such as the length of crack growth the AE energy, the AE peak amplitude, and the cumulative AE hits, showed the almost same trend in their increase as the number of fatigue cycle increased. From the comparisons of peak amplitude and AE energy with stress intensity factor, it was verified that the higher stress intensity factors generated AE signals with higher peak amplitude and a larger number of AE counts. If we can get more reliable database for the relation between AE parameters and stress intensity factor, this approach will provide a good information for evaluating both the existence of crack and the minimum detectable size of crack.

  • PDF

Relations between Seed Vigor Criteria and Field Performance in Malting Barley (맥주보리의 종자세 검정치와 포장성적과의 관계)

  • Kim, Seok-Hyeon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.6
    • /
    • pp.656-664
    • /
    • 1996
  • Three malting barley cultivars, Sacheon #6, Doosan #12, and Doosan #22 were collected from Gwangsan, Chinju and Milyang which were artificially aged to provide varying levels of seed quality. Samples were evaluated by the standard germination test (SGT), cold germination test (CT), electroconductivity test and tetrazolium vigor test (TZ). In a multiple regression analysis, percent germination in the SGT accounted for 65% of the variation in field emergence of malting barley. Vigor index of the standard germination and cold germination tests also contributed significantly to the regression equation. Grain yield was predicted by the vigor index of TZ test. Percent standard germination and percent TZ germination prediction were useful for predicting grain yield in nine lots of malting barley.

  • PDF

Nonlinear vibration analysis of MSGT boron-nitride micro ribbon based mass sensor using DQEM

  • Mohammadimehr, M.;Monajemi, Ahmad A.
    • Smart Structures and Systems
    • /
    • v.18 no.5
    • /
    • pp.1029-1062
    • /
    • 2016
  • In this research, the nonlinear free vibration analysis of boron-nitride micro ribbon (BNMR) on the Pasternak elastic foundation under electrical, mechanical and thermal loadings using modified strain gradient theory (MSGT) is studied. Employing the von $K{\acute{a}}rm{\acute{a}}n$ nonlinear geometry theory, the nonlinear equations of motion for the graphene micro ribbon (GMR) using Euler-Bernoulli beam model with considering attached mass and size effects based on Hamilton's principle is obtained. These equations are converted into the nonlinear ordinary differential equations by elimination of the time variable using Kantorovich time-averaging method. To determine nonlinear frequency of GMR under various boundary conditions, and considering mass effect, differential quadrature element method (DQEM) is used. Based on modified strain MSGT, the results of the current model are compared with the obtained results by classical and modified couple stress theories (CT and MCST). Furthermore, the effect of various parameters such as material length scale parameter, attached mass, temperature change, piezoelectric coefficient, two parameters of elastic foundations on the natural frequencies of BNMR is investigated. The results show that for all boundary conditions, by increasing the mass intensity in a fixed position, the linear and nonlinear natural frequency of the GMR reduces. In addition, with increasing of material length scale parameter, the frequency ratio decreases. This results can be used to design and control nano/micro devices and nano electronics to avoid resonance phenomenon.