• Title/Summary/Keyword: Ct value

Search Result 995, Processing Time 0.038 seconds

A Study on the Surface Contamination Level and Spatial Dose Rate Measured from NM Patients-Only Bathroom (핵의학과 전용화장실에서 측정된 표면오염도 및 공간선량율에 대한 연구)

  • Moon, Jae-Seung;Jeong, Hyi-Il;Jeong, Hae-Seong;Sin, Min-Yong;Kim, Su-Geun;Park, Dae-Seong;Kim, Hyun-Ki;Kim, Hwa-San;Lee, Hyung-Nam;Ahn, Byeong-Pil;Lee, Dong-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.38-43
    • /
    • 2012
  • Purpose: Patients injected with FDG use the bathroom that Measured surface contamination level and spatial dose rate. This study about the effect that result affects workers in same part. Materials and Methods: Group1 is St. Vincent' s hospital's 60case. Group 2 is Bucheon St. Mary's hospital's 50case. Last case is lower the average daily number of patients than group 2. Measured time is 8:00, 10:00, 13:00, 15:00 and 17:00. Measured part is 4 point of toilet, basin and wastepaper basket, also measured accumulation dose of toilet during 3 month. Hospitals is installed PET/CT ware surveyed on presence of bathroom that used only by patient and worker has been using the bathroom. Results: The highest average surface contamination level of toilet is group1($8.38{\pm}4.56$), but the highest spatial dose rate is group3. Cumulative exposure dose measured by TLD during 3months is St.Vincent's hospital 0.78 mSv and Bucheon St.Mary's hospital 0.37 mSv. And result of survey is 16.12% worker using the bathroom. Conclusions: The more daily number of patient, the higher surface contamination level of bathroom. Especially, wastepaper basket's surface contamination level is exceed the reference value $4Bq/cm^2$. Based on This survey, Bathroom require special attention and proper decontamination.

  • PDF

Evaluation of useful treatment which uses dual-energy when curing lung-cancer patient with stereotactic body radiation therapy (폐암 환자의 정위적방사선 치료 시 이중 에너지를 이용한 치료 방법의 유용성 평가)

  • Jang, Hyeong Jun;Lee, Yeong Gyu;Kim, Yeong Jae;Park, Yeong Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.87-99
    • /
    • 2016
  • Purpose : This study will evaluate the clinical utility by applying clinical schematic that uses monoenergy or dual energy as according to the location of tumors to the stereotactic radiotherapy to compare the change in actual dose given to the real tumor and the dose that locates adjacent to the tumor. Materials and Methods : CT images from a total of 10 patients were obtained and the clinical planning were planned based on the volumetric modulated arc therapy on monoenergy and dual energy. To analyze the change factor in the tumor, Comformity Index(CI) and Homogeneity Index(HI) and maximum dose quantity were each calculated and comparing the dose distribution on normal tissues, $V_{10}$ and $V_5$, first ~ fourth ribs closest to the tumor ($1^{st}{\sim}4^{th}$ Rib), Spinal Cord, Esophagus and Trachea were selected. Also, in order to confirm the accuracy on which the planned dose distribution is really measured, the 2-dimensional ion chamber array was used to measure the dose distribution. Results : As of the tumor factor, CI and HI showed a number close to 1 when the two energies were used. As of the maximum dose, the front chest wall showed 2% and the dorsal tumor showed equivalent value. As of normal tissue, the front chest wall tumors were reduced by 4%, 5% when both energies were used in the adjacent rib and as of trachea, reduced by 11%, 17%. As of the dose in the lung, as of $V_{10}$, it reduced by 1.5%, $V_5$ by 1%. As of the rear chest wall, when both energies were used, the ribs adjacent to the tumors showed 6%, 1%, 4%, 12% reduction, and in the lung dose distribution, $V_{10}$ reduced by 3%, and $V_5$ reduced by 3.1%. The dose measurement in all energies were in accordance to the results of Gamma Index 3mm/3%. Conclusion : It is considered that rather than using monoenergy, utilizing double energy in the clinical setting can be more effectively applied to the superficial tumors.

  • PDF

Feasibility Study of Dose Evaluation of Stereotactic Radiosurgery using GafChromic $EBT^{(R)}$ Film (GafChromic $EBT^{(R)}$ 필름을 이용한 뇌정위방사선치료의 선량분석 가능성 평가)

  • Jang, Eun-Sung;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose: We have performed SRS (stereotactic radiosurgery) for avm (arterry vein malformation) and brain cancer. In order to verify dose and localization of SRS, dose distributions from TPS ($X-Knife^{(R)}$ 3.0, Radionics, USA) and GafChromic $EBT^{(R)}$ film in a head phantom were compared. Materials and Methods: In this study, head and neck region of conventional humanoid phantom was modified by substituting one of 2.5 cm slap with five 0.5 cm acrylic plates to stack the GafChromic $EBT^{(R)}$ film slice by slice with 5 mm intervals. Four films and five acrylic plates were cut along the contour of head phantom in axial plane. The head phantom was fixed with SRS head ring and adapted SRS localizer as same as real SRS procedure. CT images of the head phantom were acquired in 5 mm slice intervals as film interval. Five arc 6 MV photon beams using the SRS cone with 2 cm diameter were delivered 300 cGy to the target in the phantom. Ten small pieces of the film were exposed to 0, 50, 100, 200, 300, 400, 500, 600, 700, 800, 900 cGy, respectively to calibrate the GafChromic $EBT^{(R)}$ film. The films in the phantom were digitized after 24 hours and its linearity was calibrated. The pixel values of the film were converted to the dose and compared with the dose distribution from the TPS calculation. Results: Calibration curve for the GafChromic $EBT^{(R)}$ film was linear up to 900 cGy. The R2 value was better than 0.992. Discrepancy between calculated from $X-Knife^{(R)}$ 3.0 and measured dose distributions with the film was less than 5% through all slices. Conclusion: It was possible to evaluate every slice of humanoid phantom by stacking the GafChromic EBT film which is suitable for 2 dimensional dosimetry, It was found that film dosimetry using the GafChromic $EBT^{(R)}$ film is feasible for routine dosimetric QA of stereotactic radiosurgery.

  • PDF

A Study on the Effective Half-life after the High Dose Radioactive Iodine (131I) Therapy for Thyroid Cancer Patients (갑상선암 환자에서 고용량 방사성요오드 치료 후 유효반감기에 대한 연구)

  • Kim, Seongcheol;Gwon, DaYeong;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.597-603
    • /
    • 2017
  • High-dose $^{131}I$ therapy has been generally carried out to remove remaining thyroid tissue or to cure metastasize lesion of patients who received full thyroidectomy due to differentiated thyroid cancers. In case high-dose $^{131}I$ therapy is carried out for a patient, the patient should be hospitalized being isolated for a certain period in order to restrict the amount of exposure to radiation of people at large from the patient within the limit of a level of radiation. Effective half-life is an important value to calculate how family members are exposed to radiation from a patient or to decide the period of isolation of the patient from the family members. Therefore, in this study we calculated the effective decay constant, effective half-life and period of isolation of high-dose $^{131}I$ therapy patient using NM670 SPECT/CT. As a result of carrying out this study, the effective half-life of high-dose $^{131}I$ therapy patients was derived and the time to reach the discharge level of 1.2 GBq was confirmed. When they were compared with each other in each of curative doses, the effective half-life did not have significant difference, but the time when the level of radiation remaining in the interior of the body to reach the criteria of isolation and discharge showed significant difference and it could be confirmed that the higher the curative dose the longer the period of isolation becomes. When the effective half-lives in each type of preparation were compared with each other, they did not show significant difference. However, When the times to reach the level of radiation that is the criteria of isolation and discharge in each type of preparations, they showed significant difference. The cause of the shortening of the isolation period for rhTSH patients group is decided to be low curative dose. Accordingly, if the current national health insurance (the insurance is applied to using of rhTSH in 3.7 GBq or lower) is maintained, while discerning them in each of types of preparation, we would be able to discharge patients at the time earlier than the current period of isolation (2 nights and 3 days).

The Study of Normal Tissue Complication Probability(NTCP) for Radiation Pneumonitis by Effective Volume Method (유효체적 방법과 임상분석을 통한 방사선에 의한 정상 폐조직의 부작용 확률에 관한 연구)

  • Ahn Seung Do;Choi Eun Kyung;Yi Byong Yong;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.243-249
    • /
    • 1997
  • Purpose : In radiation therapy, NTCF is very importart indicator of selecting the optimal treatment plan. In our study, we tried to find out usefullness of NTCP in lung cancer by comparng the incidence of radiation pneumonitis with NTCP. Materials and Methods : From August 1993 to December 1994, thirty six patients with locally advanced non=small cell lung cancer were treated by concurrent chemoradiation therapy. Total dose of radiation therapy was 6480cGy (120cGy, bid) and chemotherapeutlc agents were mitomycin C. vinblastion, cisplatin (2 cycles, 4 weeks interval). We evaluated the development of raniation pneumonitis by CT scan, chest x-rar and clinical symptoms. We used grading system of South Western Oncology Group (SWOG) for radiation pneumanitis. Dose Volume Histograms (DVH) were analyzed for ipsilateral and whole lung, Non uniform DVH was translated to uniform DVH by effective volume method. With these data, we calculated NTCP for ipsilateral and whole lung. Finally we compared the clinical results to NTCP. Results : Eight of thrity six patients developed radiation pneumonitis. Of these 8 patients , 6 had grade I severity and 2 had grade II. The average NTCP value cf the patients who showed radiation pneumonitis was significantly higher than that uf the patients without pneumonitis $(66\%\;vs.\;26.4\%)$. But the results of pulmonary function test was not correlated with NTCP. Conclusion : NTCP of lung is very good indicator for selecting rival treatment planning in lung cancer. According to the results of NTCP, it may be possible to adjust target volume and optimize target dose. In the near future, we are going to anaiyze the effect of hyperfractionation and concurrent chemotherapy in addition to NTCP.

  • PDF

Incidental Benign Parotid Lesions on FDG-PET: Prevalence and Clinico-pathologic Findings (FDG-PET 검사시 우연히 발견한 양성 이하선 병변: 유병율과 임상 및 병리 소견)

  • Lim, Il-Han;Lee, Won-Woo;Chung, Jin-Haeng;Park, So-Yeon;Kim, Sang-Hee;Kim, Yu-Kyeong;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.5
    • /
    • pp.359-363
    • /
    • 2007
  • Purpose: Incidental parotid lesions on F-18 FDG-PET can mimic distant metastasis of underlying malignancy. The prevalence and the clinico-pathologic findings of PET positive parotid lesions have not been known. We investigated how often incidental parotid lesions are found on clinical FDG-PET studies and what the clinico-pathologic characteristics of those parotid lesions are in the present study. Materials and Methods: We retrospectively reviewed 3,344 cases of FDG-PET which had been obtained in our hospital from May 2003 to Dec 2006. The indications of FDG-PET were: evaluation of known/suspected cancer (n= 3,212) or screening of cancer in healthy subjects (n=132). Incidental parotid lesion on FDG-PET was defined as an un-expected FDG uptake in one of parotid glands which was not primary target lesion of current FDG-PET. FDG uptake was represented by maximum standardized uptake value (maxSUV). Final diagnosis was made by pathologic analysis or clinical follow-up assessment. Results: Fifteen (0.45% = 15/3,344) incidental parotid lesions were found and they were all benign lesions. The maxSUV ranged from 1.7 to 8.6 (mean${\pm}$s.d. = $3.7{\pm}1.9$). Final diagnoses of the incidental parotid lesions were; Warthin's tumor (n=2), pleomorphic adenoma (n=1), other un-specified benign lesion (n=1), and benign lesions under bases of imaging studies (n=3) and of clinical follow-up (n=8). Conclusion: All of incidentally found parotid lesions in clinical FDG-PET studies were confirmed as benign lesions with prevalence of 0.45%. Close follow up using PET or CT might be a reasonable approach for determining the nature of incidentally found parotid lesions.

Utility of FDG-PET in Solitary Pulmonary Nodules and the Relationship Between Standardized Uptake Values of PET and Serum Glucose (폐 결절에서 FDG-PET의 유용성과 표준섭취계수와 혈당농도의 상관관계)

  • Kim, Kyu Sik;Lim, Sung Chul;Ko, Young Chun;Park, Kyung Ha;Ju, Jin Young;Jo, Kae Jung;Kim, Soo Ok;Oh, In Jae;Kim, Yu Il;Kim, Young Chul;Kim, Sung Min;Song, Ho Chun;Bom, Hee Seung;Park, Kyung Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.589-596
    • /
    • 2003
  • Background : The solitary pulmonary nodule(SPN) presents a diagnostic dilemma to the physician and the patients in the our nation with high incidence of tuberculoma. We could not exclude whether the SPN was benign or malignant by the change of the size at chest radiograph and findings of chest CT. Recently, positron emission tomography(PET) have been tried as the differential diagnostic method of SPN. We evaluated the efficacy of PET for differentiating malignant from benign SPN and the relationship between standardized uptake values(SUV) of PET and serum glucose. Method : Between January 2001 and July 2002, sixty-one patients with pulmonary nodule were examined by the chest CT and PET. The SPN has been finally diagnosed by the transthorasic needle aspiration and biopsy, bronchoscopic biopsy, and open lung biopsy. Results : Forty eight patients had a malignant nodule(23 squamous cell lung carcinoma, 16 adenocarcinoma, 9 small cell lung cancer) and thirteen patients had a benign nodule(3 tuberculoma, 9 inflammatory granuloma, 1 cryptococcosis). The mean size of malignant and benign nodule was 40.6 mm and 20.0 mm, respectively. All malignant nodules showed a marked increase in 18 fluorodeoxyglucose (FDG) uptake. Mean SUV of malignant was $9.52{\pm}5.20$ and benign nodule was $1.61{\pm}3.60$. There were false positive cases with an increase in 18-FDG uptake (2 tuberculoma, 1 inflammatory granuloma). The SUV of malignant nodule in diabetes patients has no difference in non diabetes patients($9.10{\pm}4.51$ vs $9.65{\pm}5.46$). The sensitivity and specificity of the PET scan for SPN were 100%, 77%, respectively. The positive and negative predictive values were 94% and 100%. Conclusion : PET scanning showed highly accurate result in differentiating the malignant and benign SPN. There were no significant differences between the SUV and serum glucose in the patients with lung cancer.

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.

A Study of the Making of Ornamental Metal Quiver Fittings in the Ancient Tombs of Jeongchon, Bogamri, Naju (나주 복암리 정촌 고분 출토 화살통 장식의 제작 방법 연구)

  • Lee, Hyeyoun
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.2
    • /
    • pp.242-253
    • /
    • 2020
  • Six ornamental metal quiver fittings were excavated from stone chamber No.1 of the ancient tombs of Jeongchon, Bokam-ri, Naju. The ornamental quiver fittings are metal, but the body of the quiver was made of organic material, so that it corroded and disappeared in the burial environment. The ornamental metal quiver fittings were made in pairs, and decorated one quiver according to the location they were found in and their forms. The ornamental metal quiver fitting can be divided into two types: A band style ornament (帶輪狀金具) which decorates the arrow pouch, and a board style ornament (板狀金具) which decorates the board connecting the waist belt. Two ornamental metal quiver fittings excavated from wooden coffin 2 of stone chamber No.1, were made in the band style, while the ornamental metal quiver fittings from southeast of stone chamber No.1 were identified as two boardstyle ornaments and two band-style ornaments for what was presumed to be belt loops. Material analysis of the ornamental metal quiver fittings shows that they are made of a gilt bronze plate attached to an iron plate, and the surface is marked with a speck of chisel to make lines and patterns. Chemical composition analysis (XRF) established that 24~40wt% Au and 50~93wt% Cu were detected on the gold surface, and it was confirmed that bronze corrosion had taken place on the gilt surface. SEM-EDS analysis of the gold plating layer identified a working line for glossing, and 7~9wt% Hg and an amalgam of gilt layers was detected, confirming the amalgam gilding. CT and FT-IR analysis established that the band style was double-layered with silk fabric under the iron plate, and there was also a lacquer piece underneath. The band-style ornaments have two layers of silk under the iron plate, along with lacquer pieces. Adding the fabric to the arrow pouch increases adhesion and decorative value. It is assumed that the lacquer pieces indicate that the surface of the lacquered arrow pouch had fallen together with the ornaments. On the other hand, the board-style ornaments have a thick layer of organic matter under the iron plate, but this is difficult to identify and appears to be a remnant of the quiver board. The characteristics of these ornamental metal quiver fittings were similar in Baekje, Silla, and Gaya cultures from the late 4th to the late 5th centuries, and enable us to identify the art of ancient gold craftwork at that time.

The Evaluation of Dynamic Continuous Mode in Brain SPECT (Brain SPECT 검사 시 Dynamic Continuous Mode의 유용성 평가)

  • Park, Sun Myung;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.15-22
    • /
    • 2017
  • Purpose During Brain SPECT study, critical factor for proper study with $^{99m}Tc-ECD$ or $^{99m}Tc-HMPAO$ is one of the important causes to patent's movement. It causes both improper diagnosis and examination failure. In this study, we evaluated the effect of Dynamic Continuous Mode Acquisition compared to Step and Shoot Mode to raise efficacy and reject the data set with movement, as well as, be reconstructed in certain criteria. Materials and Methods Deluxe Jaszczak phantom and Hoffman 3D Brain phantom were used to find proper standard data set and exact time. Step and Shoot Mode and Dynamic Continuous Mode Acquisition were performed with SymbiaT16. Firstly, Deluxe Jaszczak phantom was filled with $Na^{99m}TcO_4$ 370 MBq and obtained in 60 minutes to check spatial resolution compared with Step and Shoot Mode and Dynamic Continuous Mode. The second, the Hoffman 3D Phantom filled with $Na^{99m}TcO_4$ 74 MBq was acquired for 15 Frame/minutes to evaluate visual assessment and quantification. Finally, in the Deluxe Jaszczak phantom, Spheres and Rods were measured by MI Apps program as well as, checking counts with the frontal lobe, temporal lobe, occipital lobe, cerebellum and hypothalamus parts was performed in the Hoffman 3D Brain Phantom. Results In Brain SPECT Study, using Dynamic Continuous Mode rather than current Step and Shoot Mode, we can do the reading using the 20 to 50 % of the acquired image, and during the test if the patient moves, we can remove unneeded image to reduce the rate of restudy and reinjection. Conclusion Dynamic Continuous Mode in Brain study condition enhances effects compared to Step and Shoot Mode. And also is powerful method to reduce reacquisition rate caused by patient movement. The findings further indicate that it suggest rejection limit to maintain clinical value with certain reconstruction factors compared with Tomo data set. Further examination to improve spatial resolution, SPECT/CT should be the answer for that.

  • PDF