• Title/Summary/Keyword: Ct value

Search Result 989, Processing Time 0.029 seconds

Image Enhancement of Simplified Ultrasonic CT Using Frequency Analysis Method

  • Kim, kyung-Cho;Hiroaki Fukuhara;Hisashi Yamawaki
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1627-1632
    • /
    • 2002
  • In this paper, a simplified ultrasonic CT system, which uses the information in three directions, that is, 90°, +45° and -45°about the inspection plane, is applied to the high strength steel, and the frequency analysis method for enhancing the C scan or CT image is developed. This frequency analysis method is based on the frequency response property of the material. By comparing the magnitudes in the frequency domain, the special frequency which shows a significant difference between the welded joint and base material was found and used to obtain a C scan or CT image. Experimental results for several kinds of specimens, having a welded joint by electron beam welding, a weld joint by arc welding, on a fatigue crack, showed that the obtained C scan or CT image has better resolution than the results of previous experiments using the maximum value of the received waveform.

The Usefulness of Integrated PET/CT to Distinguish between Benignancy and Malignancy in Solitary Pulmonary Nodule (고립성 폐결절의 악성 감별에서 Integrated PET/CT의 유용성)

  • Park, Won-Jong;Kim, Dong-Hee;Yu, Sung-Ken;Shin, Kyeong-Cheol;Chung, Jin-Hong;Lee, Kwan-Ho;Chun, Kyung-Ah;Cho, Ihn-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.2
    • /
    • pp.205-212
    • /
    • 2006
  • Background: Malignant pulmonary nodules account for about 30 to 40 percent of solitary pulmonary nodules (SPN). Therefore, tissue characterization of SPNs is very important. Recently, PET/CT has been widely used for tissue characterization, and has become of importance. The purpose of this study was to compare and to assess multiple factors in PET/CT comparing benign and malignant nodules. Materials and Method: Nineteen patients with SPN underwent PET/CT and biopsy. The difference of standardized uptake value 1 (SUV1), standardized uptake value 2 (SUV2) and retention index in PET/CT between malignancy and benignancy were compared by Levene's test. Result: There were twelve malignant and seven benign nodules. SUV1 and SUV2 were significantly different between malignant nodule and benign nodule (p=0.006 and 0.022), but retention index was not significantly different between malignant nodule and benign nodule (p=0.526). By receiver-operating-characteristic (ROC) analysis, the sensitivity was 66.7% and the specificity was 71.4% at a cut off value of 5.40 in SUV1. The sensitivity was 75% and the specificity was 71.4% at cut off value of 7.45 in SUV2. Conclusion: There was a statistically significant difference in SUV1 and SUV2 between benign and malignant nodules. However, the cut off value of SUV1 and SUV2 by receiver-operating-characteristic (ROC) analysis was 5.40 and 7.45 which is different from previous studies. Therefore, studies on a larger sample of patients are required for confirmation.

  • PDF

The Effect of Metallic Dental Implant on Positron Emission Tomography Computed Tomography Image (금속성 치아충전물이 PET/CT영상이 미치는 영향)

  • Kim, Ki-Jin;Bae, Seok-Hwan;Han, Sang-Hyun;Yu, Se-Jong;Lee, Bo-Woo
    • Journal of Digital Convergence
    • /
    • v.10 no.2
    • /
    • pp.243-247
    • /
    • 2012
  • Beam hardening artifact happens in the CT image. when a PET/CT is conducted while there is a metallic dental implant. The artifact appears in the CT image can affect the PET image. When the patient with head and neck cancer has a metallic dental implant, Beam hardening artifact which was taken in th CT image can change the PET image and SUV value. Therefore, by Quantitative measure of the SUV according to the change in HU by the metallic dental implant, the appropriacy in the clinical application was assessed. The records of 47 patients with PET/CT August 2011. For the analysis, 2 region of interest were defined in area where CT and PET image. As a result of the experiment, if there in an implant, the HU and the SUV increased and there existed a statistically significant difference(p<0.01). Although this level of increase was not large compared with that in the patient who have no metallic dental implant, when a person has head and neck cancer, it is even more likely to be overestimated when diagnosing the cancer. When conducting PET/CT for the patient who have head and neck cancer, the physical biological parts should be considered in order not to make an error in decoding.

Usefulness Evaluation of Algorithm Conversion Method for Dose Reduction in Brain CT Examination (두부 CT 검사에서 선량감소를 위한 알고리즘 변환방법의 유용성 평가)

  • Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.481-487
    • /
    • 2019
  • Based on the scan conditions and algorithms that are generally applied during examinations during head CT examinations, the results of dose reduction through the application of algorithm changes were investigated through experiments. As a result, the dose reduction effect was more meaningful for the change of perfusion than for the tube voltage, and the quality evaluation using the brain phantom was relatively less reduced when the dose was reduced after the application of the Bone algorithm, especially for the application of the Bone algorithm, and the deviation of the mean CT number or Pixel value was measured relatively significantly. In other words, the conditions under which dose was reduced and quality was maintained to reduce the patient's exposure dose and obtain images of the same quality were obtained with the application of the Smooth algorithm and the resulting values of 120 kVp, 160 mA. At this point, doses were reduced by about 28%, and the mean CT number or Pixel value was also measured with relatively little error. If the results are applied to patients who visit the hospital for examination or follow-up after applying various algorithms and follow up scan conditions, the results are considered to be very useful in reducing patient exposure dose.

Development of Raw Material Identification Method of Changnan-jeot and Gaiyang-jeot Using Multiplex PCR and Real-Time PCR (Multiplex PCR과 Real-Time PCR을 이용한 창난젓과 가이양젓 원료 검사법 개발)

  • Choi, Seong Seok;Seo, Yong Bae;Kim, Jong-Oh;Yang, Ji-Young;Shin, Jiyoung;Kim, Gun-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.4
    • /
    • pp.289-297
    • /
    • 2021
  • In this study, multiplex PCR and real-time PCR were performed on Theragra chalcogramma (walleye pollock), Pangasianodon hypophthalmus (iridescent shark) and their processed foods, such as changnan-jeot and gaiyang-jeot (salted iridescent shark intestine). Species-specific primers for T. chalcogramma and P. hypophthalmus were designed, and genomic DNA was directly extracted from each sample to perform single PCR and multiplex PCR. As a result of PCR, in the case of single PCR, PCR bands of T. chalcogramma (297 bp) and P. hypophthalmus (132 bp) were identified, and in the case of multiplex PCR, it was confirmed that amplification occurred without cross-reaction between T. chalcogramma and P. hypophthalmus. As a result of checking the PCR sensitivity, the concentration of genomic DNA was detected up to 0.1 ng/µL in both single PCR and multiplex PCR. The real-time PCR results showed that the average Ct value of T. chalcogramma was 20.765±0.691, and the average Ct value of P. hypophthalmus sample was 35.719±1.828 in the T. chalcogramma species-specific primers. In the P. hypophthalmus species-specific primers, the average Ct value of the T. chalcogramma sample was 35.996±1.423, and the mean Ct value of the P. hypophthalmus sample was 20.096±0.793. These results demonstrated the significant differences in the efficiency, specificity and cross-reactivity of species-specific primers in real-time PCR. Based on these findings, 7 of changnan-jeot or gaiyang-jeot products were confirmed by multiplex PCR and real-time PCR, and valid results were confirmed in all samples.

Clinical Apply of Dual Energy CT (kVp switching) : A Novel Approach for MAR(Metal Artifact Reduction) Method (듀얼에너지 CT(kvp switching)의 임상 적용: MAR(Metal Artifact Reduction) 알고리즘의 적용)

  • Kim, Myeong-Seong;Jeong, Jong-Seong;Kim, Myeong-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2011
  • OThe purpose of this article was to measure and compare the value of the metal artifact reduction (MAR) algorithm by Dual energy(kVp switching) CT (Computed Tomography) for non using MAR and we introduced new variable Dual energy CT applications through a clinical scan. The used equipment was GE Discovery 750HD with Dual-Energy system(kVp switching). CT scan was performed on the neck and abdomen area subject for patients. Studies were from Dec 20 2010 to Feb 10 2011 and included 25 subject patients with prosthesis. We were measured the HU (Hounsfield Unit) and noise value at metal artifact appear(focal loss of signal and white streak artifact area) according to the using MAR algorithm. Statistical analyses were performed using the paired sample t-test. In patient subject case, the statistical difference of showing HU was p=0.01 and p=0.04 respectively. At maximum black hole artifact area and white streak artifact area according to the using MAR algorithm. However noise was p=0.05 and p=0.04 respectively; and not the affected black hole and white streak artifact area. Dual Energy CT with the MAR algorithm technique is useful reduce metal artifacts and could improve the diagnostic value in the diagnostic image evaluation of metallic implants area.

Clinical Reference of the Maximum Standardized Uptake Values to the Pancreatic Cancer, Pancreatitis and Normal Pancreas in the 18F-FDG PET-CT (18F-FDG PET-CT 검사에서 췌장암, 췌장염, 정상 췌장에 대한 최대 표준섭취계수의 임상적 기준 설정)

  • Lee, Jae-Seung;Kweon, Dae Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.80-86
    • /
    • 2018
  • The aim of this study were to establish the clinical references and guidelines for the maximum standardized uptake ($SUV_{max}$) value of pancreatic cancer, pancreatitis, and normal pancreas in $^{18}F-FDG$ PET-CT examinations for pancreatic disease. For this purpose, we performed the statistical analysis on the descriptive statistics, percentiles and inter quartiles range (IQR), normal distribution, and using the probability density function for pancreatic cancer, pancreatitis, and normal pancreas. As a result, the clinical reference of $SUV_{max}$ for the pancreatic cancer, pancreatitis, and normal pancreas was more than 3.45, 1.91 to 2.62, and less than 1.91, respectively. Also, optimal cut-off value for applying the dual time point PET-CT examination was determined to be 2.62. The results of this study are summarized as follows: first, we suggests the clinical reference and guideline for the pancreatic cancer, pancreatitis, and normal pancreas, and second, suggests a scientific approach to improve diagnostic accuracy of pancreatic disease by deviating from an approximate experience approach.

Dielectric Properties of Liquid Crystalline Polymers and $CaTiO_3-LaAlO_3$ Composites for Embedded Matching Capacitors (내장형 capacitor를 위한 LCP와 $CaTiO_3-LaAlO_3$ 복합재의 유전특성)

  • Kim, Jin-Cheol;Oh, Jun-Rok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.232-233
    • /
    • 2007
  • We manufactured Liquid Crystal Polymer (LCP) and (1-x)CaTiO3-xLaAlO3 (CT-LA) ceramic composites and investigated dielectric properties to use as embedded capacitor in printed circuit boards and replace LTCC substrate. The dielectric properties of these composites are varied with volume fraction of CT-LA and ratios of CT/LA. Dielectric constants are in the range of 3~15. In addition, we could get low TCC and High Q value that could not achieve in other ceramic-polymer composites. Especially, in composite with x=0.01 and 30 vol% CT-LA, the dieletric constant and Q-value are 10 and 200, respectively. And more TCC is $-28{\sim}300ppm/^{\circ}C$ in the temperature range of $-55{\sim}125^{\circ}C$. We think that this composites can be used high-Q substrate material like LTCC and embedded temperature compensation capacitor in printed circuit boards.

  • PDF

Adaptive Optimal Thresholding for the Segmentation of Individual Tooth from CT Images (CT영상에서 개별 치아 분리를 위한 적응 최적 임계화 방안)

  • Heo, Hoon;Chae, Ok-Sam
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.3
    • /
    • pp.163-174
    • /
    • 2004
  • The 3D tooth model in which each tooth can be manipulated individualy is essential component for the orthodontic simulation and implant simulation in dental field. For the reconstruction of such a tooth model, we need an image segmentation algorithm capable of separating individual tooth from neighboring teeth and alveolar bone. In this paper we propose a CT image normalization method and adaptive optimal thresholding algorithm for the segmenation of tooth region in CT image slices. The proposed segmentation algorithm is based on the fact that the shape and intensity of tooth change gradually among CT image slices. It generates temporary boundary of a tooth by using the threshold value estimated in the previous imge slice, and compute histograms for the inner region and the outer region seperated by the temporary boundary. The optimal threshold value generating the finnal tooth region is computed based on these two histogram.

Recurrence and Metastasis of Lung Cancer Demonstrate Decreased Diffusion on Diffusion-Weighted Magnetic Resonance Imaging

  • Usuda, Katsuo;Sagawa, Motoyasu;Motomo, Nozomu;Ueno, Masakatsu;Tanaka, Makoto;Machida, Yuichiro;Maeda, Sumiko;Matoba, Munetaka;Tonami, Hisao;Ueda, Yoshimichi;Sakuma, Tsutomu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.16
    • /
    • pp.6843-6848
    • /
    • 2014
  • Background: Diffusion-weighted magnetic resonance imaging (DWI) is reported to be useful for detecting malignant lesions. The purpose of this study is to clarify characteristics of imaging, detection rate and sensitivity of DWI for recurrence or metastasis of lung cancer. Methods: A total of 36 lung cancer patients with recurrence or metastasis were enrolled in this study. While 16 patients underwent magnetic resonance imaging (MRI), computed tomography (CT) and positron emission tomography-computed tomography (PET-CT), 17 underwent MRI and CT, and 3 underwent MRI and PET-CT. Results: Each recurrence or metastasis showed decreased diffusion, which was easily recognized in DWI. The detection rate for recurrence or metastasis was 100% (36/36) in DWI, 89% (17/19) in PET-CT and 82% (27/33) in CT. Detection rate of DWI was significantly higher than that of CT (p=0.0244) but not significantly higher than that of PET-CT (p=0.22). When the optimal cutoff value of the apparent diffusion coefficient value was set as $1.70{\times}10^{-3}mm^2/sec$, the sensitivity of DWI for diagnosing recurrence or metastasis of lung cancer was 95.6%. Conclusions: DWI is useful for detection of recurrence and metastasis of lung cancer.