• Title/Summary/Keyword: Ct value

Search Result 1,001, Processing Time 0.04 seconds

Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit (안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가)

  • Kwak, Yong Kuk;Hong, Sun Gi;Ha, Min Yong;Park, Jang Pil;Yoo, Sook Hyun;Cho, Woong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.87-95
    • /
    • 2015
  • Purpose : This study presents the usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit. Materials and Methods : We accomplished IMRT treatment plan similar with a real one through the computed treatment planning system after CT simulation using human phantom. For the secondary shield, we used Pb plate (thickness 3mm, diameter 25mm) and 3 mm tungsten eye-shield block. And we compared lens dose using OSLD between on TPS and on simulation. Also, we irradiated 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$) on a 5cm acrylic phantom using the secondary shielding material of same condition, 3mm Pb and tungsten eye-shield block. And we carried out the same experiment using 8cm Pb block to limit effect of leakage & transmitted radiation out of irradiation field. We attached OSLD with a 1cm away from the field at the side of phantom and applied a 3mm bolus equivalent to the thickness of eyelid. Results : Using human phantom, the Lens dose on IMRT treatment plan is 315.9cGy and the real measurement value is 216.7cGy. And after secondary shield using 3mm Pb plate and tungsten eye-shield block, each lens dose is 234.3, 224.1 cGy. The result of a experiment using acrylic phantom, each value is 5.24, 5.42 and 5.39 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Applying O.S.B out of the field, each value is 1.79, 2.00 and 2.02 cGy in case of no block, 3mm Pb plate and tungsten eye-shield block. Conclusion : When secondary shielding material is used to protect critical organ while irradiating photon, high atomic number material (like metal) that is near by critical organ can be cause of dose increase according to treatment region and beam direction because head leakage and collimator & MLC transmitted radiation are exist even if it's out of the field. The attempt of secondary shield for the decrease of exposure dose was meaningful, but untested attempt can have a reverse effect. So, a preliminary inspection through Q.A must be necessary.

  • PDF

The Usability Analysis of 3D-CRT, IMRT, Tomotherpy Radiation Therapy on Nasopharyngeal Cancer (NPC의 방사선치료시 3D-CRT, IMRT, Tomotherapy의 유용성 분석)

  • Song, Jong-Nam;Kim, Young-Jae;Hong, Seung-Il
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.365-371
    • /
    • 2012
  • The radiation therapy treatment technique is developed from 3D-CRT, IMRT to Tomotherapy. and these three technique was most widely using methods. We find out a comparison normal tissue doses and tumor dose of 3D-CRT, IMRT(Linac Based), and Tomotherapy on Head and Neck Cancer. We achieved radiological image used the Human model phantom (Anthropomorphic Phantom) and it was taken CT simulation (Slice Thickness : 3mm) and GTV was nasopharngeal region and PTV(including set-up margin) was GTV plus 2mm area. and transfer those images to the radiation planning system (3D-CRT - ADAC-Pinnacle3, Tomotherapy - Tomotherapy Hi-Art System). The prescription dose was 7020 cGy and measuring PTV's dose and nomal tissue (parotid gland, oral cavity, spinal cord). The PTV's doses was Tomotherapy, Linac Based - IMRT, 3D-CRT was 6923 cGy, 6901 cGy and 6718 cGy its dose value was meet TCP because its value was up to the 95% based on 7020 cGy, Nomal tissue (parotid gland, oral cavity, spinal cord) was 1966 cGy(Tomotherapy), 2405 cGy(IMRT), 2468 cGy(3D-CRT)[parotid gland], 2991 cGy(Tomotherapy), 3062 cGy(IMRT), 3684 cGy (3D-CRT)[oral cavity], 1768 cGy(Tomotherapy), 2151 cGy(IMRT), 4031 cGy(3D-CRT)[spinal cord] its value did not exceeded NTCP. All the treatment techniques are equated with tumor and nomal tissue doses. The 3D-CRT was worse than other techniques on dose distribution, but it is reasonable in terms of TCP and NTCP baseline Tomotherapy, IMRT -dose distribution was relatively superior- was hard to therapy to claustrophobic patients and patients with respiratory failure. Particularly, in case on Tomotherapy, it take MVCT before treatment so dose measurement will be unnecessary radiation exposure to patients. Conclusion, Tomotherapy was the best treatment technique and 2nd was IMRT, and 3rd 3D-CRT. But applicable differently depending on the the patient's condition even though dose not matter.

Clinical Features of Henoch-Schönlein Purpura Gastroenteropathy without Purpura before Diagnosis (진단 전에 자반이 동반되지 않았던 Henoch-Schönlein 자반 위장병증의 임상적 고찰)

  • Oh, Jae Min;Park, Jae Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.54-60
    • /
    • 2004
  • Purpose: Henoch-$Sch{\ddot{o}}nlein$ purpura (HSP) is a small-vessel vasculitic disease that most often affects the skin. Abdominal symptoms precede the typical purpuric rash of HSP in 14~36%. It is a challenge to diagnose HSP in the absence of a rash, because there are no biologic tests that can identify HSP with certainty, so we tried to find out the characteristic features of HSP gastroenteropathy without purpura before diagnosis. Methods: This study included 82 children with HSP who had been admitted or visited outward of the Department of Pediatrics, Pusan National University Hospital from 1995 to 2000. The cases that the onset of purpura preceded or coincided that of abdominal pain were defined as purpura-positive group. The cases that the onset of abdominal pain preceded purpura more than 1 week and purpura was not presented till diagnosed as HSP gastroenteropathy were defined as purpura-negative group. We compared and analyzed the clinical features of the two groups by reviewing the medical records retrospectively. To ensure the diagnosis of HSP gastroenteropathy, we conducted upper GI series, abdominal ultrasonogram, abdominal CT, endoscopy and/or skin biopsy. Results: The number of cases of purpura-positive group and purpura-negative group were 72 and 10, respectively. There is no difference between two groups in the incidence of clinical symptoms and laboratory findings. Children with HSP gastroenteropathy had characteristic erosive or ulcerative lesions in the stomach or duodenum on esophagogastroduodenoscopy, or mural thickening of the small bowel on abdominal ultrasonogram, CT or upper GI series. Skin biopsy revealed leukocytoclastic vasculitis in 3 of them, although biopsy specimen was taken from any areas of normal- appearing skin. In purpura-negative group, 9 patients improved by steroid therapy. Conclusion: In purpura-negative group, there is no diagnostic feature on the laboratory findings and clinical features. Therefore, to diagnose HSP gastroenteropathy in patients with abdominal pain in the absence of the characteristic rash, careful observation of clinical features and laboratory data, and prompt application of available diagnostic tools such as gastrointestinal endoscopy, radiologic study and skin biopsy are recommended. Early use of corticosteroid may reduce the suffering in these patients.

  • PDF

Evaluation of beam delivery accuracy for Small sized lung SBRT in low density lung tissue (Small sized lung SBRT 치료시 폐 실질 조직에서의 계획선량 전달 정확성 평가)

  • Oh, Hye Gyung;Son, Sang Jun;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate beam delivery accuracy for small sized lung SBRT through experiment. In order to assess the accuracy, Eclipse TPS(Treatment planning system) equipped Acuros XB and radiochromic film were used for the dose distribution. Comparing calculated and measured dose distribution, evaluated the margin for PTV(Planning target volume) in lung tissue. Materials and Methods : Acquiring CT images for Rando phantom, planned virtual target volume by size(diameter 2, 3, 4, 5 cm) in right lung. All plans were normalized to the target Volume=prescribed 95 % with 6MV FFF VMAT 2 Arc. To compare with calculated and measured dose distribution, film was inserted in rando phantom and irradiated in axial direction. The indexes of evaluation are percentage difference(%Diff) for absolute dose, RMSE(Root-mean-square-error) value for relative dose, coverage ratio and average dose in PTV. Results: The maximum difference at center point was -4.65 % in diameter 2 cm size. And the RMSE value between the calculated and measured off-axis dose distribution indicated that the measured dose distribution in diameter 2 cm was different from calculated and inaccurate compare to diameter 5 cm. In addition, Distance prescribed 95 % dose($D_{95}$) in diameter 2 cm was not covered in PTV and average dose value was lowest in all sizes. Conclusion: This study demonstrated that small sized PTV was not enough covered with prescribed dose in low density lung tissue. All indexes of experimental results in diameter 2 cm were much different from other sizes. It is showed that minimized PTV is not accurate and affects the results of radiation therapy. It is considered that extended margin at small PTV in low density lung tissue for enhancing target center dose is necessary and don't need to constraint Maximum dose in optimization.

Development of RMRD and Moving Phantom for Radiotherapy in Moving Tumors

  • Lee, S.;Seong, Jin-Sil;Chu, Sung-Sil;Yoon, Won-Sup;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.63-63
    • /
    • 2003
  • Purpose: Planning target volume (PTV) for tumors in abdomen or thorax includes enough margin for breathing-related movement of tumor volumes during treatment. We developed a simple and handy method, which can reduce PTV margins in patients with moving tumors, respiratory motion reduction device system (RMRDs). Materials and Methods: The patients clinical database was structured for moving tumor patients and patient setup error measurement and immobilization device effects were investigated. The system is composed of the respiratory motion reduction device utilized in prone position and abdominal presser (strip device) utilized in the supine position, moving phantom and the analysis program, which enables the analysis on patients setup reproducibility. It was tested for analyzing the diaphragm movement and CT volume differences from patients with RMRDs, the magnitude of PTV margin was determined and dose volume histogram (DVH) was computed using a treatment planning software. Dose to normal tissue between patients with RMRDs and without RMRDs was analyzed by comparing the fraction of the normal liver receiving to 50% of the isocenter dose(TD50). Results: In case of utilizing RMRDs, which was personally developed in our hospital, the value was reduced to $5pm1.4 mm$, and in case of which the belt immobilization device was utilized, the value was reduced to 3$pm$0.9 mm. Also in case of which the strip device was utilized, the value was proven to reduce to $4pm.3 mm$0. As a result of analyzing the TD50 is irradiated in DVH according to the radiation treatment planning, the usage of the respiratory motion reduction device can create the reduce of 30% to the maximum. Also by obtaining the digital image, the function of comparison between the standard image, automated external contour subtraction, and etc were utilized to develop patients setup reproducibility analysis program that can evaluate the change in the patients setup. Conclusion: Internal organ motion due to breathing can be reduced using RMRDs, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

STRESS DISTRIBUTION OF THREE NITI ROTARY FILES UNDER BENDING AND TORSIONAL CONDITIONS USING 3-DIMENSIONAL FINITE ELEMENT ANALYSIS (세가지 니켈 티타늄 파일의 휨과 비틀림 조건에서의 응력 분포에 관한 3차원 유한요소 연구)

  • Kim, Tae-Oh;Lee, Chan-Joo;Kim, Byung-Min;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.323-331
    • /
    • 2008
  • Flexibility and fracture properties determine the performance of NiTi rotary instruments. The purpose of this study was to evaluate how geometrical differences between three NiTi instruments affect the deformation and stress distributions under bending and torsional conditions using finite element analysis. Three NiTi files (ProFile .06 / #30, F3 of ProTaper and ProTaper Universal) were scanned using a Micro-CT. The obtained structural geometries were meshed with linear, eight-noded hexahedral elements. The mechanical behavior (deformation and von Mises equivalent stress) of the three endodontic instruments were analyzed under four bending and rotational conditions using ABAQUS finite element analysis software. The nonlinear mechanical behavior of the NiTi was taken into account. The U-shaped cross sectional geometry of ProFile showed the highest flexibility of the three file models. The ProTaper, which has a convex triangular cross-section, was the most stiff file model. For the same deflection, the ProTaper required more force to reach the same deflection as the other models, and needed more torque than other models for the same amount of rotation. The highest von Mises stress value was found at the groove area in the cross-section of the ProTaper Universal. Under torsion, all files showed highest stresses at their groove area. The ProFile showed highest von Mises stress value under the same torsional moment while the ProTaper Universal showed the highest value under same rotational angle.

Quality Characteristics and Variation of Wheat Breeding Lines (소맥육성계통의 품질특성과 변이에 관하여)

  • Chang, H.G.;Ryu, I.S.;Cho, C.H.;Bae, S.H.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.24 no.1
    • /
    • pp.37-45
    • /
    • 1979
  • Experiments were conducted to determine the physicochemical properties for 1.382 tested wheat harvested in 1977. All the tested wheats had a milling yield rate of 49 to 71.5 percent. The cross combination involving S.son, Caprock and CI 12703 was generally the higher in flour yield-Flour protein content ranged from about 7 percent up to about 17 percent and sedimentation values ranged from below 20 cc to 70 cc. The cross combinations involving Bb #1 gave higher protein content and higher sedimentation values than the other combinations. The distribution of the Pelshenke value was from less 20 min. to more than 180 min. Specific sedimentation values of the 329 tested wheats showed 8.1 percent to be hard quality, while 54.4 percent were of soft quality. Intermediate wheats accounted for 37.5 percent. The lines having high milling yield rate, protein content and sedimentation value from the 329 tested wheats were Strampelli \times 69D-3607/Jogwang. S.son \times Caprock. Suweon #185 \times Toropi and Suweon #185 \times Ciano. The varieties or lines including Pribog, CI 14496 and Sturdy \times Scout/ Strampelli \times Bb-Cno showed high milling yield but low protein content and low sedimentation values. being under 9 percent and 30 cc respectively.

  • PDF

A phantom production by using 3-dimentional printer and In-vivo dosimetry for a prostate cancer patient (3D 프린팅 기법을 통한 전립샘암 환자의 내부장기 팬텀 제작 및 생체내선량측정(In-vivo dosimetry)에 대한 고찰)

  • Seo, Jung Nam;Na, Jong Eok;Bae, Sun Myung;Jung, Dong Min;Yoon, In Ha;Bae, Jae Bum;Kwack, Jung Won;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.53-60
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. Materials and Methods : The phantom is produced to equally describe prostate and rectum based on a 3D volume contour of an actual prostate cancer patient who is treated in Asan Medical Center by using a 3D printer (3D EDISON+, Lokit, Korea). CT(Computed tomography) images of phantom are aquired by computed tomography (Lightspeed CT, GE, USA). By using treatment planning system (Eclipse version 10.0, Varian, USA), treatment planning is established after volume of a prostate cancer patient is compared with volume of the phantom. MOSFET(Metal OXIDE Silicon Field Effect Transistor) is estimated to identify precision and is located in 4 measuring points (bladder, prostate, rectal anterior wall and rectal posterior wall) to analyzed treatment planning and measured value. Results : Prostate volume and rectum volume of prostate cancer patient represent 30.61 cc and 51.19 cc respectively. In case of a phantom, prostate volume and rectum volume represent 31.12 cc and 53.52 cc respectively. A variation of volume between a prostate cancer patient and a phantom is less than 3%. Precision of MOSFET represents less than 3%. It indicates linearity and correlation coefficient indicates from 0.99 ~ 1.00 depending on dose variation. Each accuracy of bladder, prostate, rectal anterior wall and rectal posterior wall represent 1.4%, 2.6%, 3.7% and 1.5% respectively. In- vivo dosimetry represents entirely less than 5% considering precision of MOSFET. Conclusion : By using a 3D printer, possibility of phantom production based on prostate is verified precision within 3%. effectiveness of In-vivo dosimetry is confirmed from a phantom which is produced by a 3D printer. In-vivo dosimetry is evaluated entirely less than 5% considering precision of MOSFET. Therefore, This study is confirmed the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. It is necessary to additional phantom production by a 3D printer and In-vivo dosimetry for other organs of patient.

  • PDF

Correlation of Hepatic $^{18}F-Fluorodeoxyglucose$ Uptake with Fatty Liver (간의 $^{18}F-Fluorodeoxyglucose$ 섭취 양상과 지방간의 관계)

  • An, Young-Sil;Yoon, Joon-Kee;Hong, Seon-Pyo;Joh, Chul-Woo;Yoon, Seok-Nam
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.243-248
    • /
    • 2006
  • Purpose: Liver demonstrates heterogeneous FDG uptake and sometimes it shows abnormally increased uptake even though there is no malignant tissue. However, there was no previous study to correlate these various pattern of hepatic FDG uptake with benign liver disease. Therefore, we evaluated the significance of hepatic FDG uptake associated with various clinical factors including fatty liver, liver function tests and lipid profiles. Materials and Methods: We reviewed a total of 188 patients (male/female: 120/68, mean age: $50{\pm}9$) who underwent PET/CT for screening of malignancy. Patients with DM, impaired glucose tolerance, previous severe hepatic disease or long-term medication history were excluded. The FDG uptake in liver was analyzed semi-quantitatively using ROI on transaxial images (segment 8) and we compared mean standardized uptake value (SUV) between fatty liver and non-fatty liver group. We also evaluated the correlation between hepatic FDG uptake and various clinical factors including serum liver function test (ALT, AST), ${\gamma}-GT$, total cholesterol and triglyceride concentration. The effect of alcoholic history and body mass index on hepatic FDG uptake was analyzed within the fatty liver patients. Results: The hepatic FDG uptake of fatty liver group was significantly higher than that of non-fatty liver group. Serum total cholesterol and triglyceride concentration showed significant correlation with hepatic FDG uptake. However, there was no significant correlation between other factors (ALT, AST, and ${\gamma}-GT$) and FDG uptake. Also there was no difference of mean SUV between normal and abnormal groups on the basis of alcoholic history and body mass Index within fatty liver patients. Fatty liver and high serum triglyceride concentration were the independent factors affecting hepatic FDG uptake according to multivariate analysis. Conclusion: In conclusion, hepatic FDG uptake was strongly correlated with fatty liver and serum triglyceride concentration.

Changes in Physicochemical Characteristics during Soaking of Persimmon Pickles Treated with Organic Acids and Sugars (단감 장아찌의 저염 침지 중 유기산과 당의 종류에 따른 이화학적 특성의 변화)

  • Jeong, Do-Yeong;Kim, Yong-Suk;Jung, Sung-Tae;Shin, Dong-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.392-399
    • /
    • 2006
  • In order to develop a new persimmon pickle with a low salt concentration, changes in physicochemical characteristics during soaking of persimmon pickles treated with different organic acids and sugars were investigated at $15^{\circ}C$ for 70 days. The pH of persimmon pickles decreased from pH 6.64 at initial stage to pH 3.99 (control group), pH 2.76-3.33 (citric acid treatment, CT), and pH 3.08-3.34 (acetic acid treatment, AT) after 70-days of soaking. Titratable acidity of AT was higher (0.86-1.18%) than that of CT (0.61-0.78%). After 70-days of soaking, salinity of persimmon pickles treated with stevia leaf powder, sodium saccharin, sucrose, and isomalto-oligosaccharide were 4.94-4.96, 4.00-5.15, 2.99-3.31, and 3.03-3.30%, respectively, and 1.54-3.70% lower than that of the control group (6.69%). The hardness of persimmon pickles in all cases was increased up to 20-40-days of soaking and then decreased. L (lightness), a (redness), and b (yellowness) value of persimmon pickles treated with citric acid were higher than those of AT and the control group. Sensory evaluation of persimmon pickles after 70-days of soaking revealed that CT had the highest scores for color, texture, and overall acceptability. These results indicate that the salt concentration of persimmon pickles could be lowered by the addition of citric acid and various sugars during soaking.