• 제목/요약/키워드: Ct value

검색결과 989건 처리시간 0.029초

Ammonification and NH3 emission in the Soil Amended with Different Animal Manures

  • Wang, Xin-Lei;Zhang, Qian;Park, Sang-Hyun;Lee, Bok-Rye;Kim, Tae-Hwan
    • 한국초지조사료학회지
    • /
    • 제37권1호
    • /
    • pp.56-60
    • /
    • 2017
  • Mineralization is an important biological process for conversion of organic nitrogen (N) to inorganic N which can be used by plants directly. To investigate the effect of different manures on soil mineralization, the soil amended with cattle (CtM), goat (GM), chicken manure (ChM) and pig slurry (PS) were incubated under in vitro condition and ammonium N ($NH_4{^+}-N$), ammonification rate and ammonia emission were determined for eighty-four days. $NH_4{^+}-N$ was the highest in PS-amended soil for the whole experimental period. $NH_4{^+}-N$ in PS-amended soil was gradually decreased until day 84, whereas it was rapidly decreased for the first 14 days and then slightly increased until 84 days in ChM-, CtM- and GM-amended soil. The ammonification rate showed negative value for the first 14 days in all treatments. From day 14, ammonification rate started to increase in CtM- and ChM-amended soil, whereas it was maintained in GM- and PS-amended soil until day 84. The daily ammonia emission was the highest in PS-amended soil ($41mg\;kg^{-1}d^{-1}$), followed by CtM-, ChM-, and GM-amended soil at day 1. It was gradually decreased until day 84 in all treatments. The total $NH_3$ emission was the highest in PS-amended soil with $0.6mg\;kg^{-1}$ for 84 days, while less than $0.1mg\;kg^{-1}$ in three other plots. These results indicate that different manures showed different soil ammonification rate and $NH_3$ emission.

단순 디지털 촬영과 저선량 CT의 폐기종 소견으로부터 폐쇄성 폐기능 장애 위험 비교 (Evaluation of Obstructive Pulmonary Function Impairment Risks in Pulmonary Emphysema Detected by Low-Dose CT: Compared with Simple Digital Radiography)

  • 이원정;이정오;최병순
    • Tuberculosis and Respiratory Diseases
    • /
    • 제71권1호
    • /
    • pp.37-45
    • /
    • 2011
  • Background: Pulmonary emphysema (PE) is major cause of obstructive pulmonary function impairment (OPFI), which is diagnosed by spirometry. PE by high resolution CT is known to be correlated with OPFI. Recently, low dose CT (LDCT) has been increasingly used for screening interstitial lung diseases including PE. The aim of this study was to evaluate OPFI risks of subjects with PE detected by LDCT compared with those detected by simple digital radiography (SDR). Methods: LDCT and spirometry were administered to 266 inorganic dust exposed retired workers, from May 30, 2007 to August 31, 2008. This study was approved by our institutional review board and informed consent was obtained. OPFI risk was defined as less than 0.7 of forced expiratory volume in one second (FEV1)/forced vital capacity (FVC), and relative risk (RR) of OPFI of PE was calculated by multiple logistic regression analysis. Results: Of the 266 subjects, PE was found in 28 subjects (10.5%) by LDCT and in 11 subjects (4.1%) by SDR; agreement was relatively low (kappa value=0.32, p<0.001). FEV1 and FEV1/FVC were significantly different between PE and no PE groups determined by either SDR or LDCT. The differences between groups were larger when the groups were divided by the findings of SDR. When PE was present in either LDCT or SDR assays, the RRs of OPFI were 2.34 and 8.65, respectively. Conclusion: LDCT showed significantly higher sensitivity than SDR for detecting PE, especially low grade PE, in which pulmonary function is not affected. As a result, the OPFI risks in the PE group by LDCT was lower than that in the PE group by SDR.

PET/CT 영상에서의 표준섭취계수(SUV)의 신뢰성 확보를 위한 시스템별 차이에 관한 연구 : 초기 연구 (The Study of Difference on Each System for Reliance Security in SUV of PET/CT Images : Initial Study)

  • 박훈희;박민수;김정열;이승재;신희순;임한상;김세영;장혜원;오기백;김재삼;이창호
    • 대한디지털의료영상학회논문지
    • /
    • 제10권1호
    • /
    • pp.5-6
    • /
    • 2008
  • In this study, using an experiment, in certified an error between each system of SUV (standardized uptake value) that is one of the main analyses to diagnose a tumor in PET/CT, so, it would assure reliability and help to diagnose any lesions accurately. That is, a detailed analysis progressed. as all images reconstructed every setting time, then, clinical reliability between each system was expressed numerically at MBq/mL and SUV. Therefore, this study is considered that flexibility of follow-up using diverse system was insured, and it helps to offer accurate and beneficial information for diagnosis of various fields.

  • PDF

Characterization of Rhizophora SPP. particleboards with SOY protein isolate modified with NaOH/IA-PAE adhesive for use as phantom material at photon energies of 16.59-25.26 keV

  • Samson, Damilola Oluwafemi;Shukri, Ahmad;Mat Jafri, Mohd Zubir;Hashim, Rokiah;Sulaiman, Othman;Aziz, Mohd Zahri Abdul;Yusof, Mohd Fahmi Mohd
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.216-233
    • /
    • 2021
  • In this work, Rhizophora spp. particleboard phantoms were made using SPI-based adhesives, modified with sodium hydroxide and itaconic acid polyamidoamine-epichlorohydrin (0, 5, 10, and 15 wt%). An X-ray computed tomography (CT) imaging system was used to ascertain the CT numbers and density distribution profiles of the particleboards. The SPI-based/NaOH/IA-PAE/Rhizophora spp. particleboard phantoms with 15 wt% IA-PAE addition level had the highest solid content, flexural strength, flexural modulus, and internal bonding strength of 36.06 ± 1.08%, 18.61 ± 0.38 Nmm-2, 7605.76 ± 0.89 Nmm-2, and 0.463 ± 0.053 Nmm-2, respectively. The moisture content, mass density, water absorption, and dimensional stability were 6.93 ± 0.27%, 0.962 ± 0.037 gcm-3, 22.36 ± 2.47%, and 10.90 ± 0.86%, respectively. The results revealed that the mass attenuation coefficients and effective atomic number values within the 16.59-25.26 keV photon energy region, were close to the calculated XCOM values in water, with a p-value of 0.077. Moreover, the CT images showed that the dissimilarities in the discrepancy of the profile density decreased as the IA-PAE concentrations increased. Therefore, these results support the appropriateness of the SPI-based/NaOH/IA-PAE/Rhizophora spp. particleboard with 15 wt% IA-PAE adhesive as a suitable tissue-equivalent phantom material for medical health applications.

임상 적용 차폐물질에 따른 선량 및 CT 화질 변화 분석 (Analysis of CT Image Quality Change according to Clinical Application Shielding Materials)

  • 김현주
    • 한국방사선학회논문지
    • /
    • 제17권2호
    • /
    • pp.215-221
    • /
    • 2023
  • 수정체가 포함된 Brain CT 스캔 조건 중 관전압을 80, 100, 120 kVp로 변화시켜 적용하고 납, 납 고글, 황산바륨 실리콘 혼합 차폐체를 이용하여 선량의 변화를 분석하고, 차폐체가 화질에 영향을 미치는 정도를 SNR, CNR, SSIM 지수 분석방법을 적용하여 비교 분석해 보았다. 그 결과 모든 차폐물질 적용으로 선량 감소는 하였지만, 선량 감소 차는 크지 않은 것으로 분석되었다(P > 0.05). 또한 차폐물질 적용으로 화질의 변화는 납 고글 적용 시 SNR, CNR이 가장 높았고 SSIM 분석에서도 기준값 1에 가장 근접하여 구조적 유사도가 가장 우수한 것으로 측정되었다. 따라서, 본 연구결과를 기준으로 더욱 다양한 차폐체 적용과 임상실험 결과를 도출하여 적용한다면 차폐체 활용 검사 시 임상 적용기준에 도움을 줄 수 있을 것으로 사료된다.

The Maximum Standardized Uptake Value of 18F-FDG PET/CT in Diabetic Patients with Metastatic Pancreatic Ductal Adenocarcinoma

  • Kyu-hyun Paik;Hyoung Woo Kim;Jong-chan Lee;Jingu Kang;Yoon Suk Lee;Jaihwan Kim;Jin-Hyeok Hwang
    • Journal of Digestive Cancer Research
    • /
    • 제5권2호
    • /
    • pp.91-96
    • /
    • 2017
  • Background: To evaluate whether DM affects the SUVmax of metastatic lesions on 18F-FDG PET/CT and whether the SUVmax can influence the prognosis of metastatic PDAC patients. Methods: We conducted a retrospective study of 86 patients with metastatic PDAC who underwent PET/CT before treatment. The SUVmax of primary and metastatic lesions and the ratios of the SUVmax were measured. Long-term survival was evaluated using clinical parameters. Results: The mean SUVmax of primary lesion was lower in the DM group than in the non-DM group (4.74 vs. 5.96, p=0.009). The SUVmax for all metastatic lesions, except those in the lung, were lower in the DM group than in the non-DM group, and these differences were statistically significant in the lymph nodes and peritoneum. In the 35 patients with hepatic metastasis, higher ratios of the liver SUVmax significantly correlated with shorter OS (HR, 2.625; p=0.013). Conclusion: DM can influence the lower SUVmax of metastatic lesions as well as primary lesions. The SUVmax ratio of hepatic metastasis could influence on prognosis in metastatic PDAC patients.

  • PDF

CT 정도관리에서 ACR 팬텀을 이용한 딥러닝 모델 적용에 관한 연구 (A Study on the Application of Deep Learning Model by Using ACR Phantom in CT Quality Control)

  • 최은빈;김시온;최승원;김재희;김영균;한동균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.535-542
    • /
    • 2023
  • This study aimed to implement a deep learning model that can perform quantitative quality control through ACTS software used for quantitative evaluation of ACR phantom in CT quality control and evaluate its usefulness. By changing the scanning conditions, images of three modules of the ACR phantom's slice thickness (ST), low contrast resolution (LC), and high contrast resolution (HC) were obtained and classified as ACTS software. The deep learning model used ResNet18, implementing three models in which ST, HC, and LC were learned with epoch 50 and an integrated model in which three modules were learned with Epoch 10, 30, and 50 at once. The performance of each model was evaluated through Accuracy and Loss. When comparing and evaluating the accuracy and loss function values of the deep learning models by ST, LC, and HC modules, the Accuracy and Loss of the HC model were the best with 100% and 0.0081, and in the integrated model according to the Epoch value, Accuracy and Loss with epoch 50 were the best with 96.29% and 0.1856. This paper showed that quantitative quality control is possible through a deep learning model, and it can be used as a basis and evidence for applying deep learning to the CT quality control.

Comparison of 10 Different Pre-Enrichment Broths for the Regeneration of Cronobacter spp. (Enterobacter sakazakii ) Infected in Powdered Infant Formula

  • Jung-Whan Chon;Kun-Ho Seo;Hyungsuk Oh;Dongkwan Jeong;Kwang-Young Song
    • Journal of Dairy Science and Biotechnology
    • /
    • 제41권3호
    • /
    • pp.103-112
    • /
    • 2023
  • This study aimed to assess the effectiveness of 10 different pre-enrichment methods using Real-Time polymerase chain reaction (PCR) in support of the FDA method. When the initial Cronobacter spp. (Enterobacter sakazakii) inoculation was 7.2 CFU/g, the Ct values were observed in the following order: 21.37 (Enterobacteriaceae enrichment [EE] broth), 21.95 (brain heart infusion [BHI]), 22.72 (tryptic soy broth [TSB]), 23.02 (violet red bile lactose [VRBL]), 22.31 (TSB-0.1% sodium pyruvate [SP]), 23.43 (distilled water [DW]), 24.34 (phosphate buffered saline [PBS]), 24.95 (nutrient broth [NB]), 25.82 (TSB-0.6% yeast extract [YE]), and 28.27 (violet red bile glucose [VRBG]). For an inoculation of 1.82% CFU/g of Cronobacter spp. (E. sakazakii), the Ct values were recorded in this sequence: 20.34 (EE broth), 22.16 (TSB-0.6% YE), 22.37 (BHI), 22.71 (VRBL), 22.88 (TSB), 23.01 (DW), 23.19 (NB), 23.79 (TSB-0.1% SP), 24.66 (VRBG), and 24.70 (PBS). Finally, when the inoculum of Cronobacter spp. (E. sakazakii) was 0.182 CFU/g, the Ct values followed this order: 21.93 (VRBL), 23.07 (TSB-0.6% YE), 23.31 (DW), 23.47 (PBS), 23.70 (BHI), 24.14 (TSB-0.1% SP), 25.14 (TSB), 29.00 (VRBG), 31.55 (EE broth), and were undetected in the case of NB. Consequently, these results indicate that there were no significant differences among the 10 different pre-enrichment broths. Future studies should focus on exploring pre-enrichment broths that can improve the limit of detection at very low Cronobacter spp. (E. sakazakii) concentrations and enhance the selective recovery of Cronobacter spp. (E. sakazakii) under acid, antibiotic, cold, and heat damage conditions.

다양한 비죽상경화 관상동맥 질환의 CT 영상 소견 (CT Imaging Findings in Non-Atherosclerotic Coronary Artery Disease)

  • 박종민;박병건;강은주;이종민
    • 대한영상의학회지
    • /
    • 제83권1호
    • /
    • pp.70-83
    • /
    • 2022
  • 급성 관동맥 증후군(acute coronary syndrome)은 대부분 죽상경화 관상동맥 질환(atherosclerotic coronary artery disease)에 의해 발생하지만, 비죽상경화 관상동맥 질환에서도 발생할 수 있다. 고식적 관상동맥 혈관조영술은 동맥 내강의 협착이나 확장 등의 형상에 대한 정보만을 제공하고, 동맥경화반이나 동맥벽에 대한 평가가 어려워 관상동맥 이상의 원인 질환의 진단에 낮은 특이도를 보인다. 반면, 관상동맥 전산화단층촬영 혈관조영술은 혈관경화반의 특징, 혈관벽의 조영증강뿐 아니라 연접한 대동맥이나 폐동맥의 변화 등도 함께 관찰할 수 있어, 비죽상경화 관상상동맥질환의 진단 및 다양한 원인 감별에 도움이 된다. 따라서 이종설에서는 다양한 비죽상경화 관상동맥 질환들을 소개하고, 이의 병태생리 및 대표적인 관상동맥 전산화단층촬영 혈관조영술의 영상 소견에 대해 설명하고자 한다.

월경 주기에 따른 18F-FDG PET/CT에서 유방 섭취 변화에 관한 고찰 (A Study of the Changes of Breast Uptake in Menstrual Cycle on 18F-FDG PET/CT)

  • 탁여진;박민수;이주영;박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권1호
    • /
    • pp.31-38
    • /
    • 2015
  • $^{18}F-FDG$ PET/CT는 당대사로 인한 암세포의 비정상적인 섭취를 통해 암을 진단하는 유용한 검사이다. 일반적으로 FDG는 암세포와 염증성 질환에 높은 섭취를 보이나, 환자의 생리적 특성에 따라 정상세포에도 비정상적인 섭취를 나타내기도 한다. 특히 여성 월경 주기에 따른 유방의 비정상적인 섭취는 미세한 유방 병변의 정확한 진단을 저해하는 요인이 될 수 있다. 따라서 본 연구는 월경 주기에 따른 유방의 FDG 섭취 변화를 비교 평가하고자 한다. 평가 대상은 부인과 병력이 없고 6개월 이상 규칙적인 월경 주기를 가진 160명의 여성($34{\pm}3.5$세)을 대상으로 하였다. 환자 문진과 Pregnancy Calculator 0.14.를 이용하여 월경기, 증식기, 배란기, 분비기로 나누어 각각 40명씩 정보를 수집하였으며, PET/CT 장비는 Discovery STe(GE Healthcare, Milwaukee, Mi, USA)를 이용하였다. 분석 방법으로는 월경 주기 별 유방의 SUV 변화를 비교 분석하였으며, 핵의학 전문의 3명을 통해 Blind Test로 육안적 평가를 시행하였다. 유방의 SUV는 월경기($1.64{\pm}0.25$), 증식기($0.93{\pm}0.28$), 배란기($1.66{\pm}0.26$), 분비기($1.77{\pm}0.28$)로 나타났으며 분비기가 가장 높고 월경기와 배란기에서도 높은 섭취를 나타냈다(p<0.05). 또한 육안적 분석에서는 간과 폐의 집적에 대하여 유방의 집적 정도를 단계별로 나누어 폐와 유사한 섭취를 보인 경우(Grade I), 폐와 간 중간 정도의 섭취를 보인 경우(Grade II), 간과 같거나 높은 섭취를 보인 경우(Grade III)로 구분하였으며, 육안적 평가에서도 분비기와 월경기에서 높은 섭취를 보였다(p<0.05). 가임기 여성은 월경 주기에 따라 유방의 18F-FDG 섭취 정도가 변화되며, 특히 미세한 유방 병변을 진단하는데 월경 주기의 정보를 유용하게 활용할 수 있다. 따라서 검사 전 문진을 통하여 가임기 여성의 정확한 월경 주기를 확인하고 적정한 시기를 유도하여 검사를 시행함으로써 유방 질환에 대한 위음성 결과를 감소시킬 수 있을 것으로 사료된다.