• Title/Summary/Keyword: Ct value

Search Result 995, Processing Time 0.037 seconds

Usefulness Evaluation of HRCT using Reconstruction in Chest CT (흉부CT 검사 시 HRCT 영상 재구성의 유용성)

  • Park, Sung-Min;Kim, Keung-Sik;Kang, Seong-Min;Yoo, Beong-Gyu;Lee, Ki-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

Are There Any Additional Benefits to Performing Positron Emission Tomography/Computed Tomography Scans and Brain Magnetic Resonance Imaging on Patients with Ground-Glass Nodules Prior to Surgery?

  • Song, Jae-Uk;Song, Junwhi;Lee, Kyung Jong;Kim, Hojoong;Kwon, O Jung;Choi, Joon Young;Kim, Jhingook;Han, Joungho;Um, Sang-Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.4
    • /
    • pp.368-376
    • /
    • 2017
  • Background: A ground-glass nodule (GGN) represents early-stage lung adenocarcinoma. However, there is still no consensus for preoperative staging of GGNs. Therefore, we evaluated the need for the routine use of positron emission tomography/computed tomography (PET)/computed tomography (CT) scans and brain magnetic resonance imaging (MRI) during staging. Methods: A retrospective analysis was undertaken in 72 patients with 74 GGNs of less than 3 cm in diameter, which were confirmed via surgery as malignancy, at the Samsung Medical Center between May 2010 and December 2011. Results: The median age of the patients was 59 years. The median GGN diameter was 18 mm. Pure and part-solid GGNs were identified in 35 (47.3%) and 39 (52.7%) cases, respectively. No mediastinal or distant metastasis was observed in these patients. In preoperative staging, all of the 74 GGNs were categorized as stage IA via chest CT scans. Additional PET/CT scans and brain MRIs classified 71 GGNs as stage IA, one as stage IIIA, and two as stage IV. However, surgery and additional diagnostic work-ups for abnormal findings from PET/CT scans classified 70 GGNs as stage IA, three as stage IB, and one as stage IIA. The chest CT scans did not differ from the combined modality of PET/CT scans and brain MRIs for the determination of the overall stage (94.6% vs. 90.5%; kappa value, 0.712). Conclusion: PET/CT scans in combination with brain MRIs have no additional benefit for the staging of patients with GGN lung adenocarcinoma before surgery.

A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination (흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구)

  • Kim, Young-Keun;Yang, Sook;Wang, Tae-uk;Kim, Eun-Hye
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.

Research on Surface Contamination Analysis of Radiology Examination Equipment in Medical Institutions (의료기관 내 영상의학 검사 장비의 표면 오염도 분석 연구)

  • Shin-Woo Lee;Da-eun Kim;Chae-won Mun;Gap-Jung Kim;Sang-Ha Kim;Hye-mi Park;Se-Jong Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.171-177
    • /
    • 2024
  • In this study, two general X-ray device, CT, and MRI inspection devices were selected from general hospitals in the Daejeon area and an experiment was conducted to predict the level of infection by measuring the surface contamination of the inspection devices at different times and to use it as basic data for infection prevention. As a result, the surface contamination level by time zone for general X-ray devices and MRI examination devices was in the order of 13H > 8H > 16H, and for CT examination devices, it was 13H > 16H > 8H, which appeared to be influenced by the number of tests. In addition, the surface contamination results for each part of the test device showed that the highest ATP contamination value was found on the stand bucky handle for the general X-ray device, the headrest for the CT examination device, and the operation switch for the MRI examination device, which was closely related to the number of contacts. As a result of comparing before and after disinfection, all devices showed a significant decrease after disinfection. Based on the results of the experiment, it is believed that it can be used as basic data to identify the level of contamination in radiology laboratories and prevent infectious diseases.

Feasibility of the Threshold-Based Quantification of Myocardial Fibrosis on Cardiac CT as a Prognostic Marker in Nonischemic Dilated Cardiomyopathy

  • Na Young Kim;Dong Jin Im;Yoo Jin Hong;Byoung Wook Choi;Seok-Min Kang;Jong-Chan Youn;Hye-Jeong Lee
    • Korean Journal of Radiology
    • /
    • v.25 no.6
    • /
    • pp.540-549
    • /
    • 2024
  • Objective: This study investigated the feasibility and prognostic relevance of threshold-based quantification of myocardial delayed enhancement (MDE) on CT in patients with nonischemic dilated cardiomyopathy (NIDCM). Materials and Methods: Forty-three patients with NIDCM (59.3 ± 17.1 years; 21 male) were included in the study and underwent cardiac CT and MRI. MDE was quantified manually and with a threshold-based quantification method using cutoffs of 2, 3, and 4 standard deviations (SDs) on three sets of CT images (100 kVp, 120 kVp, and 70 keV). Interobserver agreement in MDE quantification was assessed using the intraclass correlation coefficient (ICC). Agreement between CT and MRI was evaluated using the Bland-Altman method and the concordance correlation coefficient (CCC). Patients were followed up for the subsequent occurrence of the primary composite outcome, including cardiac death, heart transplantation, heart failure hospitalization, or appropriate use of an implantable cardioverter-defibrillator. The Kaplan-Meier method was used to estimate event-free survival according to MDE levels. Results: Late gadolinium enhancement (LGE) was observed in 29 patients (67%, 29/43), and the mean LGE found with the 5-SD threshold was 4.1% ± 3.6%. The 4-SD threshold on 70-keV CT showed excellent interobserver agreement (ICC = 0.810) and the highest concordance with MRI (CCC = 0.803). This method also yielded the smallest bias with the narrowest range of 95% limits of agreement compared to MRI (bias, -0.119%; 95% limits of agreement, -4.216% to 3.978%). During a median follow-up of 1625 days (interquartile range, 712-1430 days), 10 patients (23%, 10/43) experienced the primary composite outcome. Event-free survival significantly differed between risk subgroups divided by the optimal MDE cutoff of 4.3% (log-rank P = 0.005). Conclusion: The 4-SD threshold on 70-keV monochromatic CT yielded results comparable to those of MRI for quantifying MDE as a marker of myocardial fibrosis, which showed prognostic value in patients with NIDCM.

Assessment of the Severity of Coronavirus Disease: Quantitative Computed Tomography Parameters versus Semiquantitative Visual Score

  • Xi Yin;Xiangde Min;Yan Nan;Zhaoyan Feng;Basen Li;Wei Cai;Xiaoqing Xi;Liang Wang
    • Korean Journal of Radiology
    • /
    • v.21 no.8
    • /
    • pp.998-1006
    • /
    • 2020
  • Objective: To compare the accuracies of quantitative computed tomography (CT) parameters and semiquantitative visual score in evaluating clinical classification of severity of coronavirus disease (COVID-19). Materials and Methods: We retrospectively enrolled 187 patients with COVID-19 treated at Tongji Hospital of Tongji Medical College from February 15, 2020, to February 29, 2020. Demographic data, imaging characteristics, and clinical data were collected, and based on the clinical classification of severity, patients were divided into groups 1 (mild) and 2 (severe/critical). A semiquantitative visual score was used to estimate the lesion extent. A three-dimensional slicer was used to precisely quantify the volume and CT value of the lung and lesions. Correlation coefficients of the quantitative CT parameters, semiquantitative visual score, and clinical classification were calculated using Spearman's correlation. A receiver operating characteristic curve was used to compare the accuracies of quantitative and semi-quantitative methods. Results: There were 59 patients in group 1 and 128 patients in group 2. The mean age and sex distribution of the two groups were not significantly different. The lesions were primarily located in the subpleural area. Compared to group 1, group 2 had larger values for all volume-dependent parameters (p < 0.001). The percentage of lesions had the strongest correlation with disease severity with a correlation coefficient of 0.495. In comparison, the correlation coefficient of semiquantitative score was 0.349. To classify the severity of COVID-19, area under the curve of the percentage of lesions was the highest (0.807; 95% confidence interval, 0.744-0.861: p < 0.001) and that of the quantitative CT parameters was significantly higher than that of the semiquantitative visual score (p = 0.001). Conclusion: The classification accuracy of quantitative CT parameters was significantly superior to that of semiquantitative visual score in terms of evaluating the severity of COVID-19.

Adaptation of Deep Learning Image Reconstruction for Pediatric Head CT: A Focus on the Image Quality (소아용 두부 컴퓨터단층촬영에서 딥러닝 영상 재구성 적용: 영상 품질에 대한 고찰)

  • Nim Lee;Hyun-Hae Cho;So Mi Lee;Sun Kyoung You
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.240-252
    • /
    • 2023
  • Purpose To assess the effect of deep learning image reconstruction (DLIR) for head CT in pediatric patients. Materials and Methods We collected 126 pediatric head CT images, which were reconstructed using filtered back projection, iterative reconstruction using adaptive statistical iterative reconstruction (ASiR)-V, and all three levels of DLIR (TrueFidelity; GE Healthcare). Each image set group was divided into four subgroups according to the patients' ages. Clinical and dose-related data were reviewed. Quantitative parameters, including the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and qualitative parameters, including noise, gray matter-white matter (GM-WM) differentiation, sharpness, artifact, acceptability, and unfamiliar texture change were evaluated and compared. Results The SNR and CNR of each level in each age group increased among strength levels of DLIR. High-level DLIR showed a significantly improved SNR and CNR (p < 0.05). Sequential reduction of noise, improvement of GM-WM differentiation, and improvement of sharpness was noted among strength levels of DLIR. Those of high-level DLIR showed a similar value as that with ASiR-V. Artifact and acceptability did not show a significant difference among the adapted levels of DLIR. Conclusion Adaptation of high-level DLIR for the pediatric head CT can significantly reduce image noise. Modification is needed while processing artifacts.

A Stochastic Study on Fatigue Crack Propagation and Retardation Behavior of Pressure Vessel Steel (압력용기용강의 피로균열전파 및 지연거동에 관한 확률통계적 연구)

  • 김선진;남기우;김부안
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.132-141
    • /
    • 1995
  • The purpose of the present study is to investigate the statistical characteristics of m and C in the fatigue crack propagation law, da/dN=C(.DELTA.K)/sup m/ and to studies on the randomness of fatigue crack propagation and retardation behavior. Fatigue tests were perfomed on 32 CT specimens of SPV50 steel under the same one condition. First, the value of m and C were determined for each specimen, and all the data were analyzed statistically. second, the material's resistance to fatigue crack propagation is modeled as a stchastic process, which varies randomly along the crack path. The statistical analysis of the material resistance is performed with the data obtained by constant load controlled tests. Finally, retardation behavior was examined experimentally by using a CT specimen, and a retardation parameters were analyzed statistically.

  • PDF

The development of Frameless Image-Guided Surgery system based on magnetic field digitizers (마그네틱 센서를 이용한 영상유도 뇌정위 시스템 개발)

  • Woo, J.H.;Jang, D.P.;Kim, Y.S.;Kim, Sun-I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.269-270
    • /
    • 1998
  • Image-guided surgery (IGS) system has become well known in the field of neurosurgery and spine surgery. A patient's anatomy is first registered to preoperatively acquired CT/ MRI data using the point matching algorithm. A magnetic field digitizer was used to measure the physical space data and the system was based on Workstation of Unix system. To evaluate the spatial accuracy of interactive IGS system, the phantom consisting of rods varied height and known location was used. The RMS error value between CT/MR images and real location was 3-4mm. For the more convenience of the surgery, we provide various image display modules.

  • PDF

Finite Element Analysis for Elastic Modulus of the Periodontal Ligament in Premolar Regions (소구치 치주인대의 탄성계수에 대한 유한요소 해석)

  • Chon Chang Soo;Shim June Sung;Kim Young Ho;Kim Han Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.10 s.175
    • /
    • pp.202-209
    • /
    • 2005
  • In this study, two dimensional and three dimensional finite element models of lower first premolar were analyzed. The mandibular specimen including a premolar was obtained from a cadaver and scanned with micro-CT. Finite element method models were reconstructed from CT images at mid-sagittal plane of the tooth. Most studies have used a wide range of value(0.07${\~}$1000MPa) for elastic modulus of periodontal ligament. The elastic modulus of the periodontal ligament was analyzed by finite element method and compared with that of experiment model. This study indicated that the model without pulp was more suitable than that with pulp in two dimensional finite element analysis.