• Title/Summary/Keyword: Ct value

Search Result 989, Processing Time 0.028 seconds

Consideration of the Effect of Artifact during the Image Guided Radiation Therapy Using the Fiducial Marker (영상 유도 방사선치료 시 Fiducial Marker의 Artifact에 관한 연구)

  • Kim, Jong-Min;Kim, Dae-Sup;Back, Geum-Mun;Kang, Tae-Yeong;Hong, Dong-Ki;Yun, Hwa-Yong;Kwon, Kyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Purpose: The effect of artifact was analyzed, which occurs from fiducial marker during the liver Image Guided Radiation Therapy (IGRT) using the fiducial marker. Materials and Methods: The size of artifact of fixed fiducial marker and length of mobile fiducial marker locus were measured using the On-Board Imager system (OBI) and CT simulator, and 2D-2D matching and 3D-3D matching were carried out, respectively, and at this time, the coordinates transition value of couch was analyzed. Results: The measurement of fixed fiducial marker artifact size indicated CT 4.90, 8.10, 12.90, 19.70 mm and OBI 5.60, 10.60, 14.70, 29.40 mm based on the reference CT slice thickness of 1.25, 2.50, 5.00, and 10.00 mm. Meanwhile, the measurement of mobile fiducial marker locus length indicated CT 42.00, 43.10, 46.50 mm, and OBI 43.40, 46.00, 49.30 mm. The coordinates transition of 1.00, 2.00, and 8.00 mm occurred between 2D-2D matching and 3D-3D matching. Conclusion: It was confirmed that the therapy error increased during IGRT due to the influence of artifact when CT slice thickness increased. Thus, it may be desirable to acquire the image less than 2.50 mm in slice thickness when IGRT is implemented using the fiducial marker.

  • PDF

The evaluation of the correlation between histomorphometric analysis and micro-computed tomography analysis in AdBMP-2 induced bone regeneration in rat calvarial defects

  • Park, Shin-Young;Kim, Kyoung-Hwa;Koo, Ki-Tae;Lee, Kang-Woon;Lee, Yong-Moo;Chung, Chong-Pyoung;Seol, Yang-Jo
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.5
    • /
    • pp.218-226
    • /
    • 2011
  • Purpose: Micro-computed tomography (micro-CT) has been widely used in the evaluation of regenerated bone tissue but the reliability of micro-CT has not yet been established. This study evaluated the correlation between histomorphometric analysis and micro-CT analysis in performing new bone formation measurement. Methods: Critical-size calvarial defects were created using a 8 mm trephine bur in a total of 24 Sprague-Dawley rats, and collagen gel mixed with autogenous rat bone marrow stromal cells (BMSCs) or autogenous rat BMSCs transduced by adenovirus containing bone morphogenic protein-2 (BMP-2) genes was loaded into the defect site. In the control group, collagen gel alone was loaded into the defect. After 2 and 4 weeks, the animals were euthanized and calvaria containing defects were harvested. Micro-CT analysis and histomorphometric analysis of each sample were accomplished and the statistical evaluation about the correlation between both analyses was performed. Results: New bone formation of the BMP-2 group was greater than that of the other groups at 2 and 4 weeks in both histomorphometric analysis and micro-CT analysis (P=0.026, P=0.034). Histomorphometric analysis of representative sections showed similar results to histomorphometric analysis with a mean value of 3 sections. Measurement of new bone formation was highly correlated between histomorphometric analysis and micro-CT analysis, especially at the low lower threshold level at 2 weeks (adjusted $r^2=0.907$, P<0.001). New bone formation of the BMP-2 group analyzed by micro-CT tended to decline sharply with an increasing lower threshold level, and it was statistically significant (P<0.001). Conclusions: Both histomorphometric analysis and micro-CT analysis were valid methods for measurement of the new bone in rat calvarial defects and the ability to detect the new bone in micro-CT analysis was highly influenced by the threshold level in the BMP-2 group at early stage.

Quality Assessment for Elbow CT scan by positioning and respiratory control (팔꿈치관절 CT검사에서 환자 자세 및 호흡에 따른 화질평가)

  • Lim, Jong-Chun;Park, Sang-Hyun;Lee, In-Jae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.110-114
    • /
    • 2017
  • Because the arm can't be sutured due to fracture during a elbow CT scan, a CT scan is proceeded in a state of abdomen and L-spire are overlapped which beam hardening artifact is done many times, and it often lowers the quality of elbow CT images. So there are many difficulties in reading and due to increase in radiation dose from it, the number of patient's exposure keeps increasing. In this research, it plans to improve the quality of the images by avoiding overlap with abdomen, and increasing the number of photon overlapped with lung field which the line attenuation is relatively small. The way of experiment is based on patient's right elbow and place him as head first position, then place his elbow at L2-3 level in supine position, turn about 30 degrees to the left in non-control breathing and in supine position, and compared with full inspiration after overlapping with lung. After figuring out the average value and standard deviation data using Image J program 5 times each for 16, 128 channels, the evaluation is proceeded by measuring each of CNR, MSR are statistically analyzed using SPSS program. Therefore, through positioning and inspiration during elbow CT scan, the way of inspection minimized the exposure radiation dose, and seems to be meaningful in a way to improve the quality of the images.

Significance of Hormone Receptor Status in Comparison of 18F -FDG-PET/CT and 99mTc-MDP Bone Scintigraphy for Evaluating Bone Metastases in Patients with Breast Cancer: Single Center Experience

  • Teke, Fatma;Teke, Memik;Inal, Ali;Kaplan, Muhammed Ali;Kucukoner, Mehmet;Aksu, Ramazan;Urakci, Zuhat;Tasdemir, Bekir;Isikdogan, Abdurrahman
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.1
    • /
    • pp.387-391
    • /
    • 2015
  • Background: Fluorine-18 deoxyglucose positron emission tomography computed tomography (18F-FDG-PET/CT) and bone scintigraphy (BS) are widely used for the detection of bone involvement. The optimal imaging modality for the detection of bone metastases in hormone receptor positive (+) and negative (-) groups of breast cancer remains ambiguous. Materials and Methods: Sixty-two patients with breast cancer, who had undergone both 18F-FDG-PET/CT and BS, being eventually diagnosed as having bone metastases, were enrolled in this study. Results: 18F-FDG-PET/CT had higher sensitivity and specificity than BS. Our data showed that 18F-FDGPET/CT had a sensitivity of 93.4% and a specificity of 99.4%, whiel for BS they were 84.5%, and 89.6% in the diagnosis of bone metastases. ${\kappa}$ statistics were calculated for 18F-FDGPET/CT and BS. The ${\kappa}$-value was 0.65 between 18F-FDG-PET/CT and BS in all patients. On the other hand, the ${\kappa}$-values were 0.70 in the hormone receptor (+) group, and 0.51 in hormone receptor (-) group. The ${\kappa}$-values suggested excellent agreement between all patient and hormone receptor (+) groups, while the ${\kappa}$-values suggested good agreement in the hormone receptor (-) group. Conclusions: The sensitivity and specificity for 18F-FDG-PET/CT were higher than BS in the screening of metastatic bone lesions in all patients. Similarly 18F-FDG-PET/CT had higher sensitivity and specificity in hormone receptor (+) and (-) groups.

Texture Feature Analysis Using a Brain Hemorrhage Patient CT Images (전산화단층촬영 영상을 이용한 뇌출혈 질감특징분석)

  • Park, Hyonghu;Park, Jikoon;Choi, Ilhong;Kang, Sangsik;Noh, Sicheol;Jung, Bongjae
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.369-374
    • /
    • 2015
  • In this study we proposed a texture feature analysis algorithm that distinguishes between a normal image and a diseased image using CT images of some brain hemorrhage patients, and generates both Eigen images and test images which can be applied to the proposed computer aided diagnosis system in order to perform a quantitative analysis for 6 parameters. And through the analysis, we derived and evaluated the recognition rate of CT images of brain hemorrhage. As the results of examining over 40 example CT images of brain hemorrhage, the recognition rates representing a specific texture feature-value are as follows: some appeared to be as high as 100% including average gray level, average contrast, smoothness, and Skewness while others showed a little low disease recognition rate: 95% for uniformity and 87.5% for entropy. Consequently, based on this research result, if a software that enables a computer aided diagnosis system for medical images is developed, it will lead to the availability for the automatic detection of a diseased spot in CT images of brain hemorrhage and quantitative analysis. And they can be used as computer aided diagnosis data, resulting in the increased accuracy and the shortened time in the stage of final reading.

Generation and Detection of Cranial Landmark

  • Heo, Suwoong;Kang, Jiwoo;Kim, Yong Oock;Lee, Sanghoon
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.26-32
    • /
    • 2015
  • Purpose When a surgeon examines the morphology of skull of patient, locations of craniometric landmarks of 3D computed tomography(CT) volume are one of the most important information for surgical purpose. The locations of craniometric landmarks can be found manually by surgeon from the 3D rendered volume or 2D sagittal, axial, and coronal slices which are taken by CT. Since there are many landmarks on the skull, finding these manually is time-consuming, exhaustive, and occasionally inexact. These inefficiencies raise a demand for a automatic localization technique for craniometric landmark points. So in this paper, we propose a novel method through which we can automatically find these landmark points, which are useful for surgical purpose. Materials and Methods At first, we align the experimental data (CT volumes) using Frankfurt Horizontal Plane (FHP) and Mid Sagittal Plane(MSP) which are defined by 3 and 2 cranial landmark points each. The target landmark of our experiment is the anterior nasal spine. Prior to constructing a statistical cubic model which would be used for detecting the location of the landmark from a given CT volume, reference points for the anterior nasal spine were manually chosen by a surgeon from several CT volume sets. The statistical cubic model is constructed by calculating weighted intensity means of these CT sets around the reference points. By finding the location where similarity function (squared difference function) has the minimal value with this model, the location of the landmark can be found from any given CT volume. Results In this paper, we used 5 CT volumes to construct the statistical cubic model. The 20 CT volumes including the volumes, which were used to construct the model, were used for testing. The range of age of subjects is up to 2 years (24 months) old. The found points of each data are almost close to the reference point which were manually chosen by surgeon. Also it has been seen that the similarity function always has the global minimum at the detection point. Conclusion Through the experiment, we have seen the proposed method shows the outstanding performance in searching the landmark point. This algorithm would make surgeons efficiently work with morphological informations of skull. We also expect the potential of our algorithm for searching the anatomic landmarks not only cranial landmarks.

Diagnostic Value of Computed Tomography in Crohn's Disease Patients Presenting with Acute Severe Lower Gastrointestinal Bleeding

  • Lee, Sunyoung;Ye, Byong Duk;Park, Seong Ho;Lee, Kyung Jin;Kim, Ah Young;Lee, Jong Seok;Kim, Hyun Jin;Yang, Suk-Kyun
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1089-1098
    • /
    • 2018
  • Objective: To investigate the diagnostic yield of contrast-enhanced computed tomography (CT) in Crohn's disease (CD) patients presenting with acute severe lower gastrointestinal bleeding (LGIB), and the role of CT in predicting the risk of rebleeding. Materials and Methods: A consecutive series of 110 CD patients presenting with acute severe LGIB between 2005 and 2016 were analyzed. Among them, 86 patients who had undergone contrast-enhanced CT constituted the study cohort. The diagnostic yield of CT for detecting contrast extravasation was obtained for the entire cohort and compared between different CT techniques. In a subgroup of 62 patients who had undergone CT enterography (CTE) and showed a negative result for extravasation on CTE, the association between various clinical and CTE parameters and the risk of rebleeding during subsequent follow-up was investigated using Cox regression analysis. Results: The diagnostic yield of CT was 10.5% (9 of 86 patients). The yield did not significantly differ between single-phase and multiphase examinations (p > 0.999), or between non-enterographic CT and CTE (p = 0.388). Extensive CD (adjusted hazard ratio [HR], 3.27; 95% confidence interval [CI], 1.09-9.80; p = 0.034) and bowel wall-to-artery enhancement ratio (adjusted HR, 2.81; 95% CI, 1.21-6.54; p = 0.016) were significantly independently associated with increased rebleeding risks, whereas anti-tumor necrosis factor-${\alpha}$ therapy after the bleeding independently decreased the risk of rebleeding (adjusted HR, 0.26; 95% CI, 0.07-0.95; p = 0.041). Conclusion: The diagnostic yield of contrast-enhanced CT was not high in CD patients presenting with acute severe LGIB. Nevertheless, even a negative CTE may be beneficial as it can help predict the risk of later rebleeding.

Improved Specificity of $^{18}F-FDG$ PET/CT for Lymph Node Staging of Non-Small Cell Lung Cancer Considering Calcified Lymph Node as Benign (비소세포 폐암에서 석회화 림프절을 양성으로 보았을 때 $^{18}F-FDG$ PET/CT의 특이도 향상)

  • Kwon, Seong-Young;Seo, Young-Soon;Min, Jung-Joon;Song, Ho-Chun;Na, Kook-Joo;Choi, Chan;Kim, Young-Chul;Kim, Yun-Hyun;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.16-21
    • /
    • 2007
  • Purpose: We evaluated the diagnostic value of $^{18}F-FDG$ PET/CT (PET/CT) in lymph node staging of non-small cell lung cancer (NSCLC) considering calcification and histologic types as well as FDG uptake. Materials and Methods: Fifty-three patients (38 men, 15 women; mean age, 62 years) with NSCLC underwent surgical resection (tumor resection and lymph node dissection) after PET/CT. After surgery, we compared PET/CT results with the biopsy results, and analyzed lymph node metastases, based on histologic types. PET diagnosis of lymph node metastasis was determined by maximum SUV (maxSUV) > 3.0, and PET/CT diagnosis was determined by maxSUV > 3.0 without lymph node calcification. Results: By PET diagnosis, the sensitivity, specificity, and accuracy of overall lymph node staging were 45% (13 of 29), 91% (228 of 252), and 86% (241 of 281). Specificity was 91% in both squamous cell carcinoma and adenocarcinoma, while sensitivity was 71% in squamous cell carcinoma and 36% in adenocarcinoma. When we excluded calcified lymph node with maxSUV > 3.0 from metastasis by PET/CT diagnosis, specificity improved to 98% in squamous cell carcinoma and 97% in adenocarcinoma. The degree of improvement was not dependent on histologic types. Conclusion: PET/CT improved specificity of lymph node staging by reducing false positive lymph node regardless of histologic types of NSCLC.

Evaluation of Image Quality According to Presence or Absence of Upper limbs in Scan Field of View During CT Examinations (Including LUNG MAN) (CT 검사 시 스캔 범위 내 상지 유무에 따른 영상의 질 평가(LUNG MAN 포함))

  • Zhang, Yuying;Zheng, Haoyang;Jung, Kang-gyo;Cho, Yu-Jin;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.567-573
    • /
    • 2017
  • The purpose of this study was to evaluate whether or not there was artifact when the upper limb could not be lifted to the top of the head during multi-detector computed tomography(MDCT) scans of the chest and abdomen. Contrast radiography of the human and chest phantom was performed with 128channal MDCT. Under the same conditions(120 kVp, 110 mAs, standard algorithm)both hands lifted up and put down each time in the human experiment. In the chest phantom experiment, the radiography was carried out when the upper limb phantom was adjusted at a certain distance(0, 3, 7 cm) from the chest phantom. Subsequently, the values of Noise, CT number, SNR, and CNR were measured in the field of concern. The noise value of fat, rib, and muscle increased when the arm was lifted in humans(0.79, 47.8, 27%). Furthermore, when the upper limb was lowered, the noise value of muscle and lung increased in the phantom(31.2, 9.4%). In addition, the noise value of the muscles and lung decreased by 5, 25.12% and 5.6, 15.35% as the upper limb moved about 0,3,7cm away from the chest. When the chest and abdominal radiography were performed, in the case of the presence of other parts outside the inspection area, the probability of artifact was minimal while the distance was more than 3cm away from the upper limb to the chest and abdomen.

CT Findings of Persistent Pure Ground Glass Opacity: Can We Predict the Invasiveness?

  • Liu, Li-Heng;Liu, Ming;Wei, Ran;Jin, Er-Hu;Liu, Yu-Hui;Xu, Liang;Li, Wen-Wu;Huang, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1925-1928
    • /
    • 2015
  • Background: To investigate whether CT findings can predict the invasiveness of persistent cancerous pure ground glass opacity (pGGO) by correlating the CT imaging features of persistent pGGO with pathological changes. Materials and Methods: Ninety five patients with persistent pGGOs were included. Three radiologists evaluated the morphologic features of these pGGOs at high resolution CT (HRCT). Binary logistic regression was used to assess the association between CT findings and histopathological classification (pre-invasive and invasive groups). Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of diameters. Results: A total of 105 pGGOs were identified. Between pre-invasive (atypical adenomatous hyperplasia, AAH, and adenocarcinoma in situ, AIS) and invasive group (minimally invasive adenocarcinoma, MIA and invasive lung adenocarcinomas, ILA), there were significant differences in diameter, spiculation and vessel dilatation (p<0.05). No difference was found in air-bronchogram, bubble-lucency, lobulated-margin, pleural indentation or vascular convergence (p>0.05). The optimal threshold value of the diameters to predict the invasiveness of pGGO was 12.50mm. Conclusions: HRCT features can predict the invasiveness of persistent pGGO. The pGGO with a diameter more than 12.50mm, presences of spiculation and vessel dilatation are important factors to differentiate invasive adenocarcinoma from pre-invasive cancerous lesions.