• Title/Summary/Keyword: Ct value

Search Result 989, Processing Time 0.022 seconds

Differentiation of Chromophobe Renal Cell Carcinoma and Clear Cell Renal Cell Carcinoma by Using Helical CT (나선식 CT를 이용한 혐색소형 신세포암과 투명세포형 신세포암의 감별)

  • Kim, Hong-Chul;Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.29 no.1
    • /
    • pp.14-18
    • /
    • 2012
  • Background: The purpose of this study was to differentiate chromophobe renal cell carcinoma and clear cell renal cell carcinoma on helical CT. Methods: The CT images of 9 patients histopathologically proven to have chromophobe renal cell carcinoma and 20 patients with clear cell renal cell carcinoma were reviewed. The tumor sizes, margins, enhancement degrees and patterns, presence or absence of calcification, and tumor spread patterns (including perinephric changes, venous invasion, lymphadenopathy, and distant metastasis) were compared. Results: All the chromophobe renal cell carcinomas showed well-demarcated margins. Thechromophobe renal cell carcinomas showed milder enhancements than the clear cell renal cell carcinomas. The sensitivity and specificity for differentiating the chromophobe renal cell carcinoma from the clear cell renal cell carcinoma were 100 and 88%, respectively, when 101 Hounsfield units was used as the cut-off value in the corticomedullary phase, and 95 and 100% when a less-than-three-time enhancement change was used as a cut-off value in the corticomedullary phase (p<0.05). The chromophobe renal cell carcinomas (67%) tended to show a homogeneous enhancement whereas the clear cell renal cell carcinomas (85%) usually showed a heterogeneous enhancement (p<0.05). Statistical analysis revealed that the frequencies of the tumor spread pattern and calcification in the two subtypes didnot differ significantly (p>0.05). Conclusion: The CT findings of the chromophobe renal cell carcinomascompared to those of the clear cell renal cell carcinomas showed that there were mild enhancements in the corticomedullary phase, homogeneous enhancements, and well-demarcated margins.

  • PDF

Use of positron emission tomography-computed tomography to predict axillary metastasis in patients with triple-negative breast cancer

  • Youm, Jung Hyun;Chung, Yoona;Yang, You Jung;Han, Sang Ah;Song, Jeong Yoon
    • Korean Journal of Clinical Oncology
    • /
    • v.14 no.2
    • /
    • pp.135-141
    • /
    • 2018
  • Purpose: Axillary lymph node dissection (ALND) and sentinel lymph node biopsy (SLNB) are important for staging of patients with node-positive breast cancer. However, these can be avoided in select micrometastatic diseases, preventing postoperative complications. The present study evaluated the ability of axillary lymph node maximum standardized uptake value (SUVmax) on positron emission tomography-computed tomography (PET-CT) to predict axillary metastasis of breast cancer. Methods: The records of invasive breast cancer patients who underwent pretreatment (surgery and/or chemotherapy) PET-CT between January 2006 and December 2014 were reviewed. ALNs were preoperatively evaluated by PET-CT. Lymph nodes were dissected by SLNB or ALND. SUVmax was measured in both the axillary lymph node and primary tumor. Student t-test and chi-square test were used to analyze sensitivity and specificity. Receiver operating characteristic (ROC) and area under the ROC curve (AUC) analyses were performed. Results: SUV-tumor (SUV-T) and SUV-lymph node (SUV-LN) were significantly higher in the triple-negative breast cancer (TNBC) group than in other groups (SUV-T: 5.99, P<0.01; SUV-LN: 1.29, P=0.014). The sensitivity (0.881) and accuracy (0.804) for initial ALN staging were higher in fine needle aspiration+PET-CT than in other methods. For PET-CT alone, the subtype with the highest sensitivity (0.870) and negative predictive value (0.917) was TNBC. The AUC for SUV-LN was greatest in TNBC (0.797). Conclusion: The characteristics of SUV-T and SUV-LN differed according to immunohistochemistry subtype. Compared to other subtypes, the true positivity of axillary metastasis on PET-CT was highest in TNBC. These findings could help tailor management for therapeutic and diagnostic purposes.

Usefulness of Prone Position on PET-CT in Breast Cancer (유방암 PET-CT 검사에서 Prone(복와위)자세의 유용성 평가)

  • Park, Hoon-Hee;Kim, Sei-Yung;Kim, Jung-Yul;Park, Min-Soo;Lim, Han-Snag;Jung, Suk;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho;Lee, Yung-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.44-48
    • /
    • 2008
  • Purpose: In FDG-PET/CT of breast cancer, a sensitivity was 80~96% and a specificity was 75~95% commonly. It was valuable to identify a cancer in early stage been difficult in Mammography. Most of the PET/CT scans have been examined on supine position, so, the image of breast has been acquired by reconstructed whole body scan image. However, using prone position with a compensator, a shape of breast was reassembly shown to be real by gravity. Therefore, the purpose of this study was to evaluate diagnostic value of prone position in FDG PET-CT of breast cancer. Materials and Methods: 30 female patients with doubtful or positive breast cancer were examined. The PET-CT whole body scan was acquired at 60 minutes after $^{18}F$-FDG injection on Supine position. Then, regional breast spot scan was progressed on prone position using a compensator. Each image was evaluated by physicians blinded to patient's data, and statistical analysis did through SUVs measured in PET-CT images. Results: In 27 of 30 patients, prone position was shown accurate discrimination and diagnostic value, but in another 3 patients had a lesion 1cm below, PET-CT couldn't detect it, unlike MRI. Consequently, prone position distinguished a lesion better than Supine position, because of low degree of metamorphosis by gravity. The SUVs analysis of each position was significant (p value=0.004). Conclusion: In PET-CT of breast cancer, prone position could detect micrometastasis as well as primary lesion, better than supine position. Therefore, this study proposes that any technical change considered morphological feature like prone position can offer adequate and useful diagnostic information, together with complementary quantitative analysis.

  • PDF

Image characteristics of cone beam computed tomography using a CT performance phantom (CT performance phantom을 이용한 cone beam형 전산화단층영상의 특성)

  • Han, Choong-Wan;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.157-163
    • /
    • 2007
  • Purpose: To evaluate the characteristics of (widely used) cone beam computed tomography (CBCT) images. Materials and Methods: Images were obtained with CT performance phantoms (The American Association of Physicists in Medicine; AAPM). CT phantom as the destination by using PSR $9000N^{TM}$ dental CT system (Asahi Roentgen Ind. Co., Ltd., Japan) and i-CAT CBCT (Imaging Science International Inc., USA) that have different kinds of detectors and field of view, and compared these images with the CT number for linear attenuation, contrast resolution, and spatial resolution. Results: CT number of both PSR $9000N^{TM}$ dental CT system and i-CAT CBCT did not conform to the base value of CT performance phantom. The contrast of i-CAT CBCT is higher than that of PSR $9000N^{TM}$ dental CT system. Both contrasts were increased according to thickness of cross section. Spatial resolution and shapes of reappearance was possible up to 0.6 mm in PSR $9000N^{TM}$ dental CT system and up to 1.0 mm in i-CAT CBCT. Low contrast resolution in region of low contrast sensitivity revealed low level at PSR $9000N^{TM}$ dental CT system and i-CAT CBCT. Conclusion: CBCT images revealed higher spatial resolution, however, contrast resolution in region of low contrast sensitivity was the inferiority of image characteristics.

  • PDF

The CT values Comparisons for Antibiotic Resistant Bacteria and Resistant Genes by Chlorination (항생제 내성균 및 유전자제거를 위한 염소 CT 값 비교)

  • Oh, Jun-Sik;Kim, Sungpyo
    • Journal of Wetlands Research
    • /
    • v.16 no.2
    • /
    • pp.269-274
    • /
    • 2014
  • The purpose of this study is to compare CT (disinfectant concentration * time) values in removing the antibiotic resistance bacteria, antibiotic resistance gene and transfer of antibiotic resistance genes. Different concentration of chlorine(C) and contact time(T) according to the removal of antibiotic resistance was calculated for each. As a result, for the 90% removal of antibiotic resistant bacteria, around 176~353 mg min/L CT values are needed. For the removal of the antibiotic resistance gene, 195~372 mg min/L CT values are required. For the 90% reduction of antibiotic resistance gene transfer by chlorine disinfection, 187~489 mg min/L CT values are needed. Based on our results, higher CT value was required for removing antibiotic resistant genes rather than antibiotic resistance bacteria.

Obesity Estimation of Abdominal Fat by Using Computed Tomography : Influence of Breathing Motion on The Fat Measurement (전산화단층영상을 이용한 복부 지방 계측법에서 호흡운동이 비만도 측정에 미치는 영향)

  • Seoung, Youl-Hun
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • The purpose of this study was to evaluate how much effect to accuracy when measuring abdominal fat by Computed Tomography (CT) under different respiration movements. The study volunteer composed of 66 normal adults ($50.4{\pm}11.2$ years, 33 males, 33 females). We measured their obesity by using Broca index, body mass index (BMI) and CT and have investigated the correlation. The CT scanning for the obesity measurement have done in two ways, one was done in stopping breath after exhaling and the other was holding a breath after inhaling. The results showed no statistically significant difference among the three measuring techniques. And, the error in two ways of inhaling and exhaling was showed 24.2% of volunteers. The two ways of respiration movements made different result in visceral fat area (P = 0.044), subcutaneous fat area (P = 0.636) and abdominal obesity value (P = 0.012). This study demonstrates that the two ways of respiration movements when scanning CT makes change in accuracy in visceral fat area, and in abdominal obesity quantitative measure. Therefore, our study suggests that CT should take twice in two ways while a patient stops breath after exhaling and holds a breath after inhaling when measuring abdominal obesity using CT equipments.

Role of Chest Radiographs and CT Scans and the Application of Artificial Intelligence in Coronavirus Disease 2019 (코로나바이러스감염증 2019에서 흉부X선사진 및 CT의 역할과 인공지능의 적용)

  • Seung-Jin Yoo;Jin Mo Goo;Soon Ho Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1334-1347
    • /
    • 2020
  • Coronavirus disease (COVID-19) has threatened public health as a global pandemic. Chest CT and radiography are crucial in managing COVID-19 in addition to reverse transcription-polymerase chain reaction, which is the gold standard for COVID-19 diagnosis. This is a review of the current status of the use of chest CT and radiography in COVID-19 diagnosis and management and anㄷ introduction of early representative studies on the application of artificial intelligence to chest CT and radiography. The authors also share their experiences to provide insights into the future value of artificial intelligence.

The Usefulness of $^{18}F$-FDG PET/CT for Predicting the Response of Locally Advanced Rectal Cancer to Neoadjuvant Chemoradiation Therapy (국소 진행된 직장암의 $^{18}F$-FDG PET/CT를 이용한 항암방사선치료의 반응성 예측)

  • Kang, Jin-Kyu;Kim, Mi-Sook;Choi, Chul-Won;Jeong, Su-Young;Yoo, Seong-Yul;Cho, Chul-Koo;Yang, Kwang-Mo;Yoo, Hyung-Jun;Cheon, Gi-Jeong;Shin, Young-Joo;Seo, Young-Seok
    • Radiation Oncology Journal
    • /
    • v.27 no.3
    • /
    • pp.111-119
    • /
    • 2009
  • Purpose: This study aimed at assessing the value of fluorine-18 fluorodeoxyglucose positron emission tomography ($^{18}F$-FDG PET) for predicting the response of locally advanced rectal cancer to neoadjuvant CRT. Materials and Methods: Between August 2006 and January 2008, we prospectively enrolled 20 patients with locally advanced rectal cancer and who were treated with neoadjuvant CRT at the Korea Institute of Radiological and Medical Sciences. The treatment consisted of radiation therapy and chemotherapy, and this was followed by curative resection 6 weeks later. All the patients underwent $^{18}F$-FDG PET/CT both before CRT and 6 weeks after completing CRT. The measurements of the FDG uptake ($SUV_{max}$), the absolute difference (${\Delta}SUV_{max}$) and the percent $SUV_{max}$ difference (response index, $RI_{SUV}$) between the pre- and post-CRT $^{18}F$-FDG PET/CT scans were assessed. The measurements of the metabolic volume, the absolute difference (${\Delta}$metabolic volume) and the percent metabolic volume difference (response index, $RI_{metabolic\;volume}$) were also assessed. Results: Of the 20 patients who underwent surgery, 11 patients (55%) were classified as responders according to Dworak's classification. The post-CRT $SUV_{max}$ was significantly lower than the pre-CRT $SUV_{max}$. However, there were no significant differences in the $SUV_{max}$ and the metabolic volume reduction between the responders and non-responders. We used a minimum $SUV_{max}$ reduction of 67% as the cut-off value for defining a response, with a sensitivity of 45.5%, a specificity of 88.9%, a positive predictive value of 77% and a negative predictive value of 53.8%. Conclusion: Although there were no statistically significant results in this study, other studies have revealed that $^{18}F$-FDG PET/CT has the potential to assess the tumor response to neoadjuvant CRT in patients with locally advanced rectal cancer.

Automatic Liver Segmentation by using Gray Value Portion in Enhanced Abdominal CT Image (조영제를 사용한 복부CT영상에서 명암값 비율을 이용한 간의 자동 추출)

  • Yu, Seung-Hwa;Jo, Jun-Sik;No, Seung-Mu;Sin, Gyeong-Suk;Park, Jong-Won
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.2
    • /
    • pp.179-190
    • /
    • 2001
  • In this proposed study, observing and analyzing contrast enhanced abdominal CT images, we segmented the liver automatically. We computed the ratio of each gray value from the estimated gray value range. With the average value of mesh image, we distinguished the liver from the noise parts. We divided the region based on immersion simulation. The threshold value is determined from the mesh image which is generated from each gray value portion of the liver and is used in dividing the liver to the noise region. To get the outline of the liver, we generated template image which represents the lump of the liver, and subtracted it from the binary image. With the results we use the proposed algorithm using 8-connectivity instead of the present opening algorithm, to reduce the processing time. We computed the volume from the segmented organ size and presented a clinical demonstration with the animal experiment

  • PDF

Internal Short-circuiting Estimation in Clearwell : Part A. Improving T10/T Using Intra Basin and Diffuser Wall by Applying ISEM to Field (정수지 내부 단락류 발생 평가 : Part A. 정수장 내부 단락류 분석을 통한 장폭비와 형태가 T10/T 값에 미치는 영향 연구)

  • Shin, Eunher;Lee, Seungjae;Kim, Sunghoon;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.105-112
    • /
    • 2008
  • Disinfection is a basic and effective microorganism inactivation method and historically contributed a decrease in waterborne diseases. To guarantee the disinfection ability, improving T in CT value is important. Many indexes are used to estimate the hydraulic efficiency, however, these are black-box analysis. Therefore it is need to develope new estimation method. In this study, internal short-circuiting estimation method (ISEM) is developed using CFD and we inquire into the factor which causes increase of $T_{10}/T$ value as LW ratio increases. And the effect of shape on the relation of LW ratio and $T_{10}/T$ is analyzed. As LW ratio increases, internal short-circuiting index (ISI) of influent and effluent zone is rapidly reduced and recirculation and dead zone are reduced in channel zone. Therefore, as the $T_{10}/T$ value converges maximum value, ISI curve is changed from "V" shape to "U" shape and hydraulic efficiency is improved especially in downstream portion of clearwell. The less the shape ratio(width/length of clearwell) is the less the $T_{10}/T$ value is at a same LW ratio because the portion of turning zone increases as shape ration decreases, therefore more boundary separation is generated.