• Title/Summary/Keyword: Cs-Coefficient

Search Result 211, Processing Time 0.033 seconds

Temperature Coefficient of Dielectric Constant in CaTiO3-A(B′, B″)O3 Microwave Dielectric Ceramics (A=Ca, La, Li, B′=Al, Fe, Mg, B″=Nb, Ta)

  • Kim, Jeong-Seog;Cheon, Chae-Il;Park, Chan-Sik;Byun, Jae-Dong
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.10
    • /
    • pp.925-930
    • /
    • 2003
  • The dielectric polarizability-related factors contributing to the $\tau$$_{\varepsilon}$ have been analysed in terms of dielectric permittivity $\varepsilon$, Tolerance Factor (TF), and octahedron tilt angles in (1-x)CaTi $O_3$-x[A(B', B″) $O_3$] (A=Ca, La, Li, B'=Al, Fe, Mg, B″=Nb, Ta) and (S $r_{0.2}$C $a_{0.8}$)( $Ti_{1-x}$ Z $r_{x}$) $O_3$. All the compounds have the orthorhombic Pbnm structure except the end members A(B', B″) $O_3$ and the solid solutions of x$\geq$0.8. The additional dipole field effect is suggested as a dominant factor contributing to $\tau$$_{\varepsilon}$ in CaTi $O_3$-based ceramics having relatively large $\varepsilon$, which has not been generally considered in the previous reports dealing with the $\tau$$_{\varepsilon}$. This study has been focussed on delineating the dipole field effect on the $\tau$$_{\varepsilon}$ in comparison to the octahedron tilt effect in CaTi $O_3$-based ceramics.cs..cs.

Solidification of high level waste using magnesium potassium phosphate compound

  • Vinokurov, Sergey E.;Kulikova, Svetlana A.;Myasoedov, Boris F.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.755-760
    • /
    • 2019
  • Compound samples based on the mineral-like magnesium potassium phosphate matrix $MgKPO_4{\times}6H_2O$ were synthesized by solidification of high level waste surrogate. Phase composition and structure of synthesized samples were studied by XRD and SEM methods. Compressive strength of the compounds is $12{\pm}3MPa$. Coefficient of thermal expansion of the samples in the range $250-550^{\circ}C$ is $(11.6{\pm}0.3){\times}10^{-6}1/^{\circ}C$, and coefficient of thermal conductivity in the range $20-500^{\circ}C$ is $0.5W/(m{\times}K)$. Differential leaching rate of elements from the compound, $g/(cm^2{\times}day)$: $Mg-6.7{\times}10^{-6}$, $K-3.0{\times}10^{-4}$, $P-1.2{\times}10^{-4}$, $^{137}Cs-4.6{\times}10^{-7}$; $^{90}Sr-9.6{\times}10^{-7}$; $^{239}Pu-3.7{\times}10^{-9}$, $^{241}Am-9.6{\times}10^{-10}$. Leaching mechanism of radionuclides from the samples at the first 1-2 weeks of the leaching test is determined by dissolution ($^{137}Cs$), wash off ($^{90}Sr$) or diffusion ($^{239}Pu$ and $^{241}Am$) from the compound surface, and when the tests continue to 90-91 days - by surface layer depletion of compound. Since the composition and physico-chemical properties of the compound after irradiation with an electron beam (absorbed dose of 1 MGy) are constant the radiation resistance of compound was established.

The Reliability and Validity Testing of Korean Version of the Pittsburgh Sleep Quality Index (한국어판 피츠버그 수면의 질 지수(PSQI-K) 도구의 신뢰도와 타당도 검증)

  • Shin, Seunghwa;Kim, Su Hyun
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.11
    • /
    • pp.148-155
    • /
    • 2020
  • The purpose of the study was to test the reliability and validity of the Korean version of Pittsburgh Sleep Quality Index (PSQI-K) and to examine the cutoff point of the PSQI-K for screening insomnia among young adults. The subjective quality and patterns of sleep in 64 participants were measured using PSQI-K and Fitbit Charge 3TM. The properties of the instrument were analyzed using Cronbach's alpha coefficient for the internal consistency reliability, factor analysis for the construct validity, and Spearman's rho correlation coefficient for the correlation between the PSQI-K total scores and Fitbit tracker scores. The Cronbach's alpha coefficient of the PSQI-K was 0.69. The Spearman's rho correlation coefficient between the PSQI-K and Fitbit tracker was higher than 0.67. A cutoff point of ≥6.0 had a sensitivity of 0.93 and a specificity of 0.84. In conclusion, the PSQI-K is a reliable and valid instrument to evaluate sleep disturbance in Korean young adults.

Implementation of waste silicate glass into composition of ordinary cement for radiation shielding applications

  • Eid, Mohanad S.;Bondouk, I.I.;Saleh, Hosam M.;Omar, Khaled M.;Sayyed, M.I.;El-Khatib, Ahmed M.;Elsafi, Mohamed
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1456-1463
    • /
    • 2022
  • The aim of this work is to study the radiation shielding properties of cement samples with waste glass incortated into its composition. The mass attenuation coefficient (MAC) of the samples were experimentally determined to evaluate their radiation shielding ability. The experimental coefficient was evaluated using NaI detector for gamma energies between 59.53 keV and 1408.01 keV using different radioactive point sources Am-241, Eu-152, Co-60, and Cs-137, and the gamma transmission parameters half-value layer, mean free path, and transmission factor were calculated. The theoretical coefficient of the composites was determined using Geant4 and XCOM software. The results were also compared against Geant4 and XCOM simulations by calculating the relative deviation between the values to determine the accuracy of the results. In addition the mechanical properties (including Compressive and porosity) as well as the thermogravimetric analysis were tested for the present samples. Overall, it was concluded that the cement sample with 50% waste glass has the greatest shielding potential for radiation shielding applications and is a useful way to reuse waste glass.

SOC Verification Based on WGL

  • Du, Zhen-Jun;Li, Min
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.12
    • /
    • pp.1607-1616
    • /
    • 2006
  • The growing market of multimedia and digital signal processing requires significant data-path portions of SoCs. However, the common models for verification are not suitable for SoCs. A novel model--WGL (Weighted Generalized List) is proposed, which is based on the general-list decomposition of polynomials, with three different weights and manipulation rules introduced to effect node sharing and the canonicity. Timing parameters and operations on them are also considered. Examples show the word-level WGL is the only model to linearly represent the common word-level functions and the bit-level WGL is especially suitable for arithmetic intensive circuits. The model is proved to be a uniform and efficient model for both bit-level and word-level functions. Then Based on the WGL model, a backward-construction logic-verification approach is presented, which reduces time and space complexity for multipliers to polynomial complexity(time complexity is less than $O(n^{3.6})$ and space complexity is less than $O(n^{1.5})$) without hierarchical partitioning. Finally, a construction methodology of word-level polynomials is also presented in order to implement complex high-level verification, which combines order computation and coefficient solving, and adopts an efficient backward approach. The construction complexity is much less than the existing ones, e.g. the construction time for multipliers grows at the power of less than 1.6 in the size of the input word without increasing the maximal space required. The WGL model and the verification methods based on WGL show their theoretical and applicable significance in SoC design.

  • PDF

Applicability of Domestic Bentonite as a Buffer Material of Spent Fuel Repository (사용후핵연료 처분장 완충재로서 국산벤토나이트의 활용성)

  • Park, Jong-Won;Whang, Joo-Ho;Chun, Kwan-Sik;Lee, Byung-Hun
    • Nuclear Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.410-419
    • /
    • 1991
  • Four domestic bentonite samples collected from the south-eastern area of Korea were identified as Ca-bentonite by analysing XRD-patterns and chemical compositions. By comparing the surface area, CEC and the swelling rate of these samples, Dong-Hae A was selected as a suitable sample for the investigation of distribution coefficients. Sorption equilibrium of Cs, Co and Am was reached in around 10 days, but that of Sr was found to be much earlier. From the measured distribution coefficients, the domestic bentonite was found to have high sorption capacity. In the effect of varying concentration on the distribution coefficient, the values of radionuclides peaked at about 10$^{-7}$ mo1/$\ell$ of concentration.

  • PDF

A Combined Procedure of RSM and LHS for Uncertainty Analyses of CsI Release Fraction Under a Hypothetical Severe Accident Sequence of Station Blackout at Younggwang Nuclear Power Plant Using MAAP3.0B Code

  • Han, Seok-Jung;Tak, Nam-Il;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.507-521
    • /
    • 1996
  • Quantification of uncertainties in the source term estimations by a large computer code, such as MELCOR and MAAP, is an essential process of the current Probabilistic safety assessment. The main objective of the present study is to investigate the applicability of a combined procedure of the response surface method (RSM) based on input determined from a statistical design and the Latin hypercube sampling (LHS) technique for the uncertainty analysis of CsI release fractions under a Hypothetical severe accident sequence of a station blackout at Younggwang nuclear power plant using MAAP3. OB code as a benchmark problem. On the basis of the results obtained in the present work, the RSM is recommended to be used as a principal tool for an overall uncertainty analysis in source term quantifications, while using the LHS in the calculations of standardized regression coefficients (SRC) and standardized rank regression coefficient (SRRC) to determine the subset of the most important input parameters in the final screening step and to check the cumulative distribution functions obtained by RSM. Verification of the response surface model for its sufficient accuracy is a prerequisite for the reliability of the final results that can be obtained by the combined procedure proposed in the present work.

  • PDF

An Improved Non-CSD 2-Bit Recursive Common Subexpression Elimination Method to Implement FIR Filter

  • Kamal, Hassan;Lee, Joo-Hyun;Koo, Bon-Tae
    • ETRI Journal
    • /
    • v.33 no.5
    • /
    • pp.695-703
    • /
    • 2011
  • The number of adders and critical paths in a multiplier block of a multiple constant multiplication based implementation of a finite impulse response (FIR) filter can be minimized through common subexpression elimination (CSE) techniques. A two-bit common subexpression (CS) can be located recursively in a noncanonic sign digit (CSD) representation of the filter coefficients. An efficient algorithm is presented in this paper to improve the elimination of a CS from the multiplier block of an FIR filter so that it can be realized with fewer adders and low logical depth as compared to the existing CSE methods in the literature. Vinod and others claimed the highest reduction in the number of logical operators (LOs) without increasing the logic depth (LD) requirement. Using the design examples given by Vinod and others, we compare the average reduction in LOs and LDs achieved by our algorithm. Our algorithm shows average LO improvements of 30.8%, 5.5%, and 22.5% with a comparative LD requirement over that of Vinod and others for three design examples. Improvement increases as the filter order increases, and for the highest filter order and lowest coefficient width, the LO improvements are 70.3%, 75.3%, and 72.2% for the three design examples.

Simultaneous Determination of the Flavonoids and Limonoids in Citrus junos Seed Shells Using a UPLC-DAD-ESI/MS

  • Jo, Ara;Shin, Ji hun;Song, Hwa young;Lee, Ye Eun;Jeong, Da Eun;Oh, Sung Hwa;Mun, Myung Jae;Lee, Mina
    • Natural Product Sciences
    • /
    • v.26 no.1
    • /
    • pp.64-70
    • /
    • 2020
  • Citrus junos seeds (CS) have been traditionally used for the treatment of cancer and neuralgia. They are also used to manufacture edible oil and cosmetic perfume. A large amount of CS shells without oil (CSS) are discarded after the oil in CS is used as foods or herbal remedy. To efficiently utilize CSS as a by-products, it needs to be studied through chemical analysis. Therefore, we developed an ultra-performance liquid chromatography (UPLC)-diode array detection (DAD) method for simultaneous determination and quantitative analysis of five components (two flavonoids and threes limonoids) in CSS. A Waters Acquity UPLC HSS T3 column C18 (2.1 × 100 mm, 1.8 ㎛) was used for this separation. It was maintained at 40 ℃. The mobile phase used for the analysis was distilled water and acetonitrile with gradient elution. To identify the quantity of the five components, a mass spectrometer (MS) with an electrospray ionization (ESI) source was used. The regression equation showed great linearity, with correlation coefficient ≥ 0.9912. Limits of detection (LOD) and limits of quantification (LOQ) of the five compounds were 0.09 - 0.13 and 0.26 - 0.38 ㎍/mL, respectively. Recoveries of extraction ranged from 97.45% to 101.91%. Relative standard deviation (RSD) values of intra- and inter-day precision were 0.06 - 1.15% and 0.19 - 0.25%, respectively. This UPLC-DAD method can be validated to simultaneously analyze quantities of marker flavonoids and limonoids in CSS.

Accuracy of full arch digital model obtained from rendering-based intraoral scanner(IOS) : An example of CS-3600 system (동영상 촬영방식의 구강스캐너로 채득된 전악치열 디지털모형의 정확도 분석 : CS-3600 시스템을 중심으로)

  • Kim, Jae-Hong
    • Journal of Technologic Dentistry
    • /
    • v.42 no.1
    • /
    • pp.17-25
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate and compare the accuracy of definitive casts that are fabricated from digital intraoral impression and conventional impression technique. Methods: A master model(ANNA-4, Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CS-3600 intraoral scanner(n=10). Six linear measurements were recorded between landmarks, directly on each of the stone models on two occasions by a single examiner. Measurements were made with a digital caliper to the nearest 0.01mm from manual models and with the software(Delcam PowerSHAPE) from the virtual models. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed good reliability. The ICC of the two models were 0.88~0.91(stone model) and 0.94~0.99(digital model). The mean differences to master model for stone model and digital model were 0.10~0.14mm, and 0.14~0.20mm, respectively. Conclusion: The definitive casts obtained with digital intraoral technique model had significantly larger dimensions as compared to those of the stone model. However, the differences to the master model detected appear to provide enough accuracy and reliability for clinical application.