• Title/Summary/Keyword: Cs-137

Search Result 532, Processing Time 0.024 seconds

Induction of Radiation Adaptive Response in Lymphocytes of patients Undergoing Bone Scintigraphy (골 신티그라피를 시행한 환자의 림프구에서 방사선 적응반응의 유도에 관한 연구)

  • Min, Jung-Jun;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.172-177
    • /
    • 1999
  • Purpose: The purpose of this study was to ascertain whether radiation adaptive response could be induced by Tc-99m-methylene diphosphonate (Tc-99m-MDP) in peripheral lymphocytes of patients undergoing bone scintigraphy. Materials and Methods: Lymphocytes from 22 patients (6 males, 16 females, mean age $50{\pm}14$ years) were collected before and after bone scintigraphy using 740 MBq Tc-99m-MDP Lymphocytes from 10 controls (6 males, 4 females, mean age $43{\pm}7$ years) were also collected. They were exposed to challenge dose of 2 Gy gamma rays using a cell irradiator. Number of ring-form and dicentric chromosomes per 600 cells (chromosomal aberrations) was counted under the light microscope. Results: Chromosomal aberrations in patients before bone scintigraphy ($385.1{\pm}30.5$) was not different from that of controls ($367.8{\pm}36.6$). However, chromosomal aberrations in patients after bone scintigraphy was significantly decreased to $192.6{\pm}22.1$ (p=0.0001). Conclusion: Low dose gamma-irradiation by Tc-99m-MDP used for bone scintigraphy induces a cytogenetic adaptive response in peripheral lymphocytes.

  • PDF

Individual Variation of Radiation Adaptive Responses in Patients Undergoing Imaging Studies Using $^{99m}Tc$ Labeled Radiopharmaceuticals ($^{99m}Tc$ 표지 방사성의약품을 이용한 핵의학 영상검사를 받은 환자에서 방사선 적응반응의 개인간 차이에 대한 연구)

  • Li, Ming-Hao;Bom, Hee-Seung;Kwon, An-Sung;Kim, Young-Ho;Kim, Ji-Yeul
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.2
    • /
    • pp.117-125
    • /
    • 2003
  • It was reported that radiopharamaceuticals induced radiation adaptive response (RAR) in patients undergoing nuclear medicine imaging studies. Individual variations of RAR were not studied well. The purpose of this study was to evaluate individual variation of RAR in patients undergoing nuclear medicine imaging studies. Peripheral lymphocytes were collected from 23 patients undergoing $^{99m}Tc-diethylenetriamine$ pentaacetic acid $(^{99m}Tc-DTPA)$ renal scintigraphy, 18 patients undergoing $^{99m}Tc-methylene$ diphosphonate $(^{99m}Tc-MDP)$ bone scintigraphy and 21 patients undergoing $^{99m}Tc-tetrofosmin\;(^{99m}Tc-TF)$ scintigraphy were collected before and 4 hours after injection of radiopharmaceuticals. The lymphocytes were exposed to challenge dose of 2 Gy gamma rays using a cell irradiator. Numbers of ring-form (R) and dicentric (D) chromosomes were counted under the light microscope. and used to calculate the frequency of chromosomal aberration [Ydr=(D+R)/total number of counted lymphocytes]. Adaptation index (k) was defined 3s ratio of Ydr in conditioned lymphocytes over Ydr in unconditioned lymphocytes. Coefficients of variance of k in $^{99m}Tc-DTPA,\;^{99m}Tc-MDP\;and\;^{99m}Tc-TF$ were 35%, 34% and 21%, respectively k was not dependent upon age, sex, and underlying diseases. There was a wide variation of RAR induced by radiopharmaceuticals among patients undergoing nuclear medicine procedures. It remains to be determined for causes of such variation.

Design and Performance Evaluation of Small Size Counting and Imaging Gamma Probe System (소형 계수용 및 영상용 감마프로브 시스템의 설계와 성능평가)

  • Yang, Myo-Geun;Kwark, Cheol-Eun;Sim, yong-Geol;Kim, Hee-Joung;Choi, Yong;Chung, Jung-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.291-299
    • /
    • 1997
  • As a microimaging device detecting gamma rays emitted from small lesions or tumors during operation, the intraoperative surgical probe has been proposed and is now under development. We have designed a multipurpose portable gamma prove system and evaluated the performance both for the absolute counting purpose of residual radioactivities and for the localizing capability of gamma events using the NaI(Tl) crystal and two types of photomultiplier tubes(PMTs). Counting efficiencies in the range of routine clinical use of radiation dose were measured using the assembly of single channel PMTs and 0.5 inch thick NaI(Tl) crystal of 1 inch diameter. The positioning of gamma events for imaging purpose requires the multiple channel PMTs with appropriate positioning electronics. We have designed a simple and reliable positioning circuit based on the concept of modified Anger. In preliminary experiments using the multiple channel PMT of 3 inch diameter and the dim lighth source, we were able to trace and localize the correct position with reduced positioning error by the use of two multiplier/divider chipset and simplified peripherals. The energy resolutions for the counting gamma probe measured as full width at half maximum(FWHM) for Cs-137, F-18, Tc-99m were 12%, 13%, and 36%, respectively. The spatial resolution for the imaging gamma probe measured as FWHM for green LED was 2.9 mm. The results indicate that the currently developing probe is very promising and could be very useful for many applications in nuclear medicine. Future studies will include developing collimators, improving interface hardwares, and evaluating the system with clinical data.

  • PDF

An Evaluation of the Structural Integrity of the Polymer-Modified Cement Waste Form (폴리머 시멘트 고화체에 대한 구조적 건전성 평가)

  • Ji, Young-Yong;Kwak, Kyung-Kil;Hong, Dae-Seok;Kim, Tae-Kuk;Ryu, Woo-Seog
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.2
    • /
    • pp.81-86
    • /
    • 2011
  • Polymer-modified cement is the composite material made by partially replacing and strengthening the cement hydrate binders of conventional mortar with polymeric modifiers such as polymer latexes and redispersible polymeric modifiers. It is known that the addition of polymer to cement mortar leads to improved quality, which would be expected to have a high chemical resistance. Therefore, the purpose of this study is to identify the improved chemical resistance, such as low permeability and low ion diffusivity, of the polymer-modified cement as a solidification agent for the radwaste. First, polymer-modified cement specimens by latex modification were prepared according to the polymer content from 0% to 30% to select the optimized polymer content. At those specimens, the water-to-cement (W/C) ratio was maintained to 33% and 50% respectively. After the much curing time, the structural integrity of specimens was evaluated through the compressive strength test and the porosity evaluation by the water immersion method. From the results, 10% of the polymer content at 33% of the W/C ratio was shown to have the most improved quality. Finally, the leaching test referredfrom ANS 16.1 for the specimens having the most improved quality was conducted. Dedicated specimens for the leaching test were then mixed with radioisotopes of $^{60}Co$ and $^{137}Cs$ at the specimen preparation.

Marinelli Beaker Measurement and Self Absorption Correction and Application for Various Environmental Samples in Monte Carlo Simulation (몬테카를로 시뮬레이션에서의 다양한 환경 샘플에 대한 Marinelli 비이커 측정 및 자기 흡수 보정과 적용)

  • Jang, Eun-Sung;Gim, Yang-Soo;Lee, Sun-Young
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.605-611
    • /
    • 2017
  • The structure of the actual detector was computed using the code of the PENELOPE. Using the standard mixed sources (450, 1,000 ml), compare the effectiveness of each energy according to various densities and height of the PENELOPE computer simulation, and calculate the effectiveness of the various environmental specimens and apply them to various environmental specimens to determine the lower limit. The values obtained by the obtained value were obtained by applying the obtained efficiency to the actual environmental specimens and obtaining the lower limit values. The density correction factor is 1.155 g of the density correction factor of $0.4g/cm^3$ (59.54keV), 1.153 (661 keV), $1.06g/cm^3$ 1.064 (1,836.04keV), 1.03, and 1.033. It was confirmed that the radioactivity concentration of environmental samples decreased as the amount of specimen was measured increases, and the MDA value decreased as time measured increases.

Studies on the Establishment of Tolerance Level of Radioactive Compounds in Livestock Feeds (가축 사료 중 방사성 물질 허용 기준 설정에 관한 연구)

  • Lee, Wanno;Ji, Sang-Yun;Kim, Jin Kyu;Lee, Yun-Jong;Park, Jun Cheol;Moon, Hong Kil;Lee, Ju-Woon
    • Journal of Radiation Industry
    • /
    • v.5 no.4
    • /
    • pp.337-345
    • /
    • 2011
  • In order to provide an effective preparedness for a nuclear or radiological emergency happening in the domestic or neighborhood countries and to solve the vague fear of the people for the ingestion of radioactive livestock products, the establishment of national guideline level for radionuclides in feed is urgently necessary. This is because it is important to secure the safety and to manage the crisis in the agricultural, fishery and food sector by performing the effective safety control during and after nuclear incident. This study was performed to investigate the report cases of international organizations and foreign countries to set up a domestic control standard for managing radioactive substances that may be contaminated in animal feeds due to the nuclear power plant incident. In addition, an attempt was made to provide a useful reference that can help prepare a domestic control standard, using a coefficient that can consider the transfer into livestock through the intake of radioactive contaminated animal feeds. The standard radioisotopes investigated were confined to radioactive cesium ($^{137+134}Cs$) and iodine ($^{131}I$). Guideline level for the radionuclides was calculated by using the transfer coefficient factor and the maximum daily intake of animal feed provided by IAEA. For example, the maximum daily intake of animal feed was set as $25kg\;d^{-1}$ for dairy cows, $10kg\;d^{-1}$ for beef cattle, $3.0kg\;d^{-1}$ for pigs and $0.15kg\;d^{-1}$ for chickens. The result values for radioactive cesium were calculated as $8,696Bq\;kg^{-1}$, $4,545Bq\;kg^{-1}$, $1,667Bq\;kg^{-1}$ and $2,469Bq\;kg^{-1}$, respectively. The results for radioactive iodine showed the ranges between $741Bq\;kg^{-1}$ and $76,628Bq\;kg^{-1}$. These data can be utilized as a scientific reference for the preparation of a crisis management manual for the emergency control due to nuclear power plant accident in Korea and neighboring country. These results will contribute to establish the safe feed management system at national level as manual for responding the radioactive exposure of agricultural products and animal feeds, which are currently not established.

Statistical Analysis of Count Rate Data for On-line Seawater Radioactivity Monitoring

  • Lee, Dong-Myung;Cong, Binh Do;Lee, Jun-Ho;Yeo, In-Young;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.64-71
    • /
    • 2019
  • Background: It is very difficult to distinguish between a radioactive contamination source and background radiation from natural radionuclides in the marine environment by means of online monitoring system. The objective of this study was to investigate a statistical process for triggering abnormal level of count rate data measured from our on-line seawater radioactivity monitoring. Materials and Methods: Count rate data sets in time series were collected from 9 monitoring posts. All of the count rate data were measured every 15 minutes from the region of interest (ROI) for $^{137}Cs$ ($E_{\gamma}=661.6keV$) on the gamma-ray energy spectrum. The Shewhart ($3{\sigma}$), CUSUM, and Bayesian S-R control chart methods were evaluated and the comparative analysis of determination methods for count rate data was carried out in terms of the false positive incidence rate. All statistical algorithms were developed using R Programming by the authors. Results and Discussion: The $3{\sigma}$, CUSUM, and S-R analyses resulted in the average false positive incidence rate of $0.164{\pm}0.047%$, $0.064{\pm}0.0367%$, and $0.030{\pm}0.018%$, respectively. The S-R method has a lower value than that of the $3{\sigma}$ and CUSUM method, because the Bayesian S-R method use the information to evaluate a posterior distribution, even though the CUSUM control chart accumulate information from recent data points. As the result of comparison between net count rate and gross count rate measured in time series all the year at a monitoring post using the $3{\sigma}$ control charts, the two methods resulted in the false positive incidence rate of 0.142% and 0.219%, respectively. Conclusion: Bayesian S-R and CUSUM control charts are better suited for on-line seawater radioactivity monitoring with an count rate data in time series than $3{\sigma}$ control chart. However, it requires a continuous increasing trend to differentiate between a false positive and actual radioactive contamination. For the determination of count rate, the net count method is better than the gross count method because of relatively a small variation in the data points.

A Study on the Improvement of Gamma Ray Energy Spectrum Resolution through Electrical Noise Reduction of High Purity Ge Detector (고순도 Ge 검출기의 전기적 노이즈 감소를 통한 감마선 에너지 스펙트럼의 분해능 향상에 관한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.849-856
    • /
    • 2020
  • In the gamma-ray energy spectrum study, nuclide analysis through energy analysis is very important. High-purity Ge detectors, which are commonly used for gamma-ray energy measurements, are commonly used because of their high energy resolution and relatively high detection efficiency. However, in order to maintain a high energy resolution, the semiconductor detector has a problem in that it is difficult to maintain the original performance if the noise generated from the surrounding environment is not effectively blocked, and the effect of the expensive device is not achieved. Therefore, in this study, ground loop isolator (NEXT-001HDGL) was used to remove the electrical noise generated from the detector. In order to test the effect of improving energy resolution, HPGe detection device newly installed in the proton accelerator KOMAC was used. In the case of gamma-ray energy 2614 keV, the energy resolution was improved from (0.16 ± 0.02) % to (0.11 ± 0.01) %, and in the case of gamma-ray energy 662 keV of 137Cs isotope, the energy resolution was improved from (0.72 ± 0.07) % to (0.27 ± 0.03) %. This result is considered to be very useful for the gamma ray spectrum study using the HPGe detection equipment of KOMAC(Korea Multi-Purpose Accelerator Complex).

Study of Naturally Occurring Radioactive Material Present in Deep Soil of the Malwa Region of Punjab State of India Using Low Level Background Gamma-Ray Spectrometry

  • Srivastava, Alok;Chahar, Vikash;Chauhan, Neeraj;Krupp, Dominik;Scherer, Ulrich W.
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.16-21
    • /
    • 2022
  • Background: Epidemiological observations such as mental retardation, physical deformities, etc., in children besides different types of cancer in the adult population of the Malwa region have been reported. The present study is designed to get insight into the role of naturally occurring radioactive material (NORM) in causing detrimental health effects observed in the general population of this region. Materials and Methods: Deep soil samples were collected from different locations in the Malwa region. Their activity concentrations were determined using low-level background gammaray spectrometry. High efficiency and high purity germanium detector capped in a lead-shielded chamber having a resolution of 1.8 keV at 1,173 keV and 2.0 keV at the 1,332 keV line of 60Co was used in the present work. Data were evaluated with Genie-2000 software. Results and Discussion: Mean activity concentrations of 238U, 232Th, and 40K in deep soil were found to be 101.3 Bq/kg, 65.8 Bq/kg, and 688.6 Bq/kg, respectively. The mean activity concentration of 238U was found to be three and half times higher than the global average prescribed by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). It was further observed that the activity concentration of 232Th and 40K has a magnitude that is nearly one and half times higher than the global average prescribed by UNSCEAR. In addition, the radioisotope 137Cs which is likely to have its origin in radiation fallout was also observed. It is postulated that the NORM present in high quantity in deep soil somehow get mobilized into the water aquifers used by the general population and thereby causing harmful health problems. Conclusion: It can be stated that the present work has been able to demonstrate the use of low background gamma-ray spectrometry to understand the role of NORM in causing health-related effects in a general population of the Malwa region of Punjab, India.

Application of peak based-Bayesian statistical method for isotope identification and categorization of depleted, natural and low enriched uranium measured by LaBr3:Ce scintillation detector

  • Haluk Yucel;Selin Saatci Tuzuner;Charles Massey
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3913-3923
    • /
    • 2023
  • Todays, medium energy resolution detectors are preferably used in radioisotope identification devices(RID) in nuclear and radioactive material categorization. However, there is still a need to develop or enhance « automated identifiers » for the useful RID algorithms. To decide whether any material is SNM or NORM, a key parameter is the better energy resolution of the detector. Although masking, shielding and gain shift/stabilization and other affecting parameters on site are also important for successful operations, the suitability of the RID algorithm is also a critical point to enhance the identification reliability while extracting the features from the spectral analysis. In this study, a RID algorithm based on Bayesian statistical method has been modified for medium energy resolution detectors and applied to the uranium gamma-ray spectra taken by a LaBr3:Ce detector. The present Bayesian RID algorithm covers up to 2000 keV energy range. It uses the peak centroids, the peak areas from the measured gamma-ray spectra. The extraction features are derived from the peak-based Bayesian classifiers to estimate a posterior probability for each isotope in the ANSI library. The program operations were tested under a MATLAB platform. The present peak based Bayesian RID algorithm was validated by using single isotopes(241Am, 57Co, 137Cs, 54Mn, 60Co), and then applied to five standard nuclear materials(0.32-4.51% at.235U), as well as natural U- and Th-ores. The ID performance of the RID algorithm was quantified in terms of F-score for each isotope. The posterior probability is calculated to be 54.5-74.4% for 238U and 4.7-10.5% for 235U in EC-NRM171 uranium materials. For the case of the more complex gamma-ray spectra from CRMs, the total scoring (ST) method was preferred for its ID performance evaluation. It was shown that the present peak based Bayesian RID algorithm can be applied to identify 235U and 238U isotopes in LEU or natural U-Th samples if a medium energy resolution detector is was in the measurements.