• 제목/요약/키워드: Cryogenics Vessel

검색결과 27건 처리시간 0.022초

Method applied to evaluate heat leakage of cryogenic vessel for liquid hydrogen

  • Li, Zhengqing;Yang, Shengsheng;Wang, Xiaojun;Yuan, Yafei
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권1호
    • /
    • pp.7-11
    • /
    • 2021
  • Cryogenic vessels are special equipment that requires periodic evaluation of their thermal insulation performance. At the current standard, the test is considered as the loss product or heat leakage of cryogenic vessel, which takes over 72 h to evaluate; consequently, a large amount of working medium is discharged to the environment in the process. However, hydrogen is flammable and explosive, and the discharged gas may be dangerous. If liquid hydrogen is replaced with liquid nitrogen before testing, the operation then becomes complicated, and the loss product or heat leakage cannot respond to the thermal insulation performance of cryogenic vessels for liquid hydrogen. Therefore, a novel method is proposed to evaluate the heat leakage of cryogenic vessels for liquid hydrogen in self-pressurization. In contrast to the current testing methods, the method proposed in this study does not require discharge or exchange of working medium in all test processes. The proposed method is based on one-dimensional heat transfer analysis of cryogenic vessels, which is verified by experiment. When this method is used to predict the heat leakage, the comparison with the experimental data of the standard method shows that the maximum error of heat leakage is less than 5.0%.

Performance evaluation of 80 GHz FMCW Radar for level measurement of cryogenic fluid

  • Mun, J.M.;Lee, J.H.;Lee, S.C.;Sim, K.D.;Kim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.56-60
    • /
    • 2021
  • The microwave Radar used for special purposes in the past is being applied in various areas due to the technological advancement and cost reduction, and is particularly applied to autonomous driving in the automobile field. The FMCW (Frequency Modulated Continuous Wave) Radar can acquire level information of liquid in vessel based on the beat frequency obtained by continuously transmitting and receiving signals by modulating the frequency over time. However, for cryogenic fluids with small impedance differences between liquid medium and gas medium, such as liquid nitrogen and liquid hydrogen, it is difficult to apply a typical Radar-based level meter. In this study, we develop an 80 GHz FMCW Radar for level measurement of cryogenic fluids with small impedance differences between media and analyze its characteristics. Here, because of the low intrinsic impedance difference, most of the transmitted signal passes through the liquid nitrogen interface and is reflected at the bottom of the vessel. To solve this problem, a radar measurement algorithm was designed to detect multiple targets and separate the distance signal to the bottom of the vessel in order to estimate the precise position on the liquid nitrogen interface. Thereafter, performance verification experiments were performed according to the liquid nitrogen level using the developed radar level meter.

단열재가 극저온 용기의 내부지지대 구조설계에 미치는 영향 (A Study on Thermal Insulator Effect for Structure Design of Internal Support on Cryogenic Vessel)

  • 김두호;지현진;김기열;조성백
    • 한국군사과학기술학회지
    • /
    • 제14권3호
    • /
    • pp.524-531
    • /
    • 2011
  • The cryogenic vessel, storing a liquified solutions as LOX and $LN_2$, consists of a external vessel, internal vessel, thermal insulator and internal support. The internal support should be satisfied with mechanical strength not only to support weight of internal tank but also to maintain uniform space between external and internal tank in spite of external mechanical shock. However, excessive structure design of internal supports is able to increase the amount of heat conduction and the rate of vaporization. The thermal insulator, filled with space between a external and internal vessel, reduces the rate of heat transfer and guarantees the standing time of cryogenic vessel. Especially powder type of insulator has low thermal conductivity and reduce the specification of structure design. In order to evaluate the effect of insulator on structure design, the experiment set-up simulated cryogenic vessel was tested in shock environment according to thermal insulator. As a result, the behavior of internal support under external shock was understood and the design criteria was able to be suggested.

Optimization approach of insulation thickness of non-vacuum cryogenic storage tank

  • MZAD, Hocine;HAOUAM, Abdallah
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.17-23
    • /
    • 2020
  • Cryogenic insulation systems, with proper materials selection and execution, can offer the highest levels of thermal performance. Insulations are listed in order of increasing performance and, generally, in order of increasing cost. The specific insulation to be used for a particular application is determined through a compromise between cost, ease of application and the effectiveness of the insulation. Consequently, materials, representative test conditions, and engineering approach for the particular application are crucial to achieve the optimum result. The present work is based on energy cost balance for optimizing the thickness of insulated chambers, using foamed or multi layered cryogenic shell. The considered insulation is a uniformly applied outer layer whose thickness varies with the initial and boundary conditions of the studied vessel under steady-state radial heat transfer. An expression of the optimal insulation thickness derived from the total cost function and depending on the geometrical parameters of the container is presented.

적외선 우주망원경 냉각시스템 열설계 및 열침입량 측정 (Thermal Design and Heat Load Measurement of PSICS)

  • 양형석;김동락;이병섭;최연석
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.43-46
    • /
    • 2005
  • A Protomodel Space Infrared Cryogenic System (PSICS) cooled by a stirling cryocooler was designed. The PSICS has an IR sensor inside a cold box which is cooled by a stilting cryocooler with refrigeration capacity of 500mw at 80K in a vacuum vessel. It is important to minimize heat load for reducing background thermal noise. In order to design the cryogenic system of low heat load and to reduce heat load, we did several numerical analyses and tested using boil-off calorimetry with liquid nitrogen to measure the heat leak of the system. In this paper, we present the results obtained by thermal analysis and heat load measurement for designing the PSICS.

적층단열재의 열침입량 측정 (Measurement of Heat Leak through Multi-Layer Insulation)

  • 김동락;양형석;정원묵;이병섭;신필권;황시돌
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.39-42
    • /
    • 2005
  • In this paper, the thermal characteristics of multilayer insulation (MLI) were experimentally investigated by using boil-off calorimetry method for seeking optimum standards of thermal insulation conditions. It is necessary to design the thermal insulating efficiency for applying to cryogenic instruments such as HTS power cable system. It is well known that the thermal characteristics and heat transfer of MLI are greatly affected by various MLI structures such as the number of layers and layer density, etc. However, it is difficult to know the thermal characteristics of MLI correctly. The heat leak by MLI between room temperature and liquid nitrogen temperature was measured at various conditions using a cylindrical cryostat. The cryostat consists of two guard vessels located at both end sides and a test vessel between them. The guard vessels are also filled with liquid nitrogen to prevent radiation heat leak through the both end side of the cylindrical test vessel to measure the heat leak only through MLI.

Simple predictive heat leakage estimation of static non-vacuum insulated cryogenic vessel

  • Mzad, Hocine
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권3호
    • /
    • pp.25-30
    • /
    • 2020
  • The diminishing of heat leak into cryogenic vessels can prolong the storage time of cryogenic liquid. With the storage of cryogenic liquid reducing, the heat leak decreases, while the actual storage time increases. Regarding to the theoretical analysis, the obtained results seems to be constructive for the cryogenic insulation system applications. This study presents a predictive assessment of heat leak occurring in non-vacuum tanks with a single layer of insulation. A Radial steady-state heat transfer, based on heat conduction equation, is taken into consideration. Graphical results show the thermal performance of the insulation used, they also allow us to choose the appropriate insulation thickness according to the shape and diameter of the storage tank.

Specific Heat Measurement of Insulating Material using Heat Diffusion Method

  • Choi, Yeon-Suk;Kim, Dong-Lak
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.32-35
    • /
    • 2012
  • The objective of the present work is to develop a precise instrument for measuring the thermal property of insulating material over a temperature range from 30 K to near room temperature by utilizing a cryocooler. The instrument consists of two thermal links, a test sample, heat sink, heat source and vacuum vessel. The cold head of the cryocooler as a heat sink is thermally anchored to the thermal link and used to bring the apparatus to a desired temperature in a vacuum chamber. An electric heater as a heat source is placed in the middle of test sample for generating uniform heat flux. The entire apparatus is covered by thermal shields and wrapped in multi-layer insulation to minimize thermal radiation in a vacuum chamber. For a supplied heat flux the temperature distribution in the insulating material is measured in steady and transient state. The thermal conductivity of insulating material is measured from temperature difference for a given heat flux. In addition, the specific heat of insulating material is obtained by solving one-dimensional heat diffusion equation.

3MJ급 SMES용 HTS 전류리드부의 제작 및 성능평가 (Fabrication and Performance test of HTS current lead part of 3MJ SMES)

  • 심기덕;조전욱;김해종;배준한;김해준;성기철
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.7-9
    • /
    • 2003
  • A 3MJ class SMES was fabricated last year. And 1000A class current part for the SMES also was designed, fabricated and tested. The current lead was made of metal part(brass) and HTS lead Part. The lead is located in vacuum vessel and cooled down to belows the HTS lead's operating temperature. We made three types of current lead part and tested their performance. In this paper, the basic and conceptual type of current lead will be introduced. The lead was expected to have 1000A current capacity. But the test results was only 480A. After this test, based on the results we revised the shape of the lead and improved the connectivity between cryocooler and lead. In this paper, the design procedure and the results of performance test will be introduced.

  • PDF

저항형 한류기 운전조건에서의 과냉각 액체질소 특성 실험 (Experimental Investigation of the Subcooled Liquid Nitrogen for Resistive Superconducting Fault Current Limiter)

  • 조승연;김동락;양형석;정원묵;김도형;김혜림;현옥배
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.332-334
    • /
    • 2003
  • A subcooled liquid nitrogen cryostat is required for the cooling of a 6.6 ㎸, 200 A resistive type superconductive fault current limiter (SFCL). To help understand and design an appropriate cryostat for SFCL a prototype cryostat was fabricated and tested. Several states of subcooled liquid nitrogen were obtained by using cryocooler and helium gas. The temperature was uniformly distributed inside the liquid nitrogen vessel within the range of 0.4 K proving the effectiveness of the conduction cylinder.

  • PDF