A new method fast measure cryogenic vessel heat leakage

  • LI, Zheng-Qing;LI, Xiao-Jin;LIU, Mo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.24-28
    • /
    • 2020
  • Heat leakage is an important parameter to reflect heat insulated performance of cryogenic vessel. According to the current standard requirements, it needs to measure the daily evaporation rate to indicate heat leakage. The test needs-over 24h after cryogenic vessel in heat equilibrium as standard required, therefore test efficiency is poor and new efficient method is required to cut test time. First of all, the volume of instantaneous evaporated gas and heat leakage are calculated by the current standard corresponding to the maximum allowable daily evaporation rate of cryogenic vessel. Depending on the relationship between real daily evaporation rate and maximum allowable daily evaporation rate of cryogenic vessel, we designed a new test method based on the pressure changes over time in cryogenic vessel to determine whether its heat insulated performance meets requirements or not. Secondly, the heat transfer process was analyzed in measurement of cryogenic vessel, and the heat transfer equations of whole system were established. Finally, the test was completed in four hours; meanwhile the heat leakage and daily evaporation rate of cryogenic vessel are calculated basing on test data.

단열재가 극저온 용기의 내부지지대 구조설계에 미치는 영향 (A Study on Thermal Insulator Effect for Structure Design of Internal Support on Cryogenic Vessel)

  • 김두호;지현진;김기열;조성백
    • 한국군사과학기술학회지
    • /
    • 제14권3호
    • /
    • pp.524-531
    • /
    • 2011
  • The cryogenic vessel, storing a liquified solutions as LOX and $LN_2$, consists of a external vessel, internal vessel, thermal insulator and internal support. The internal support should be satisfied with mechanical strength not only to support weight of internal tank but also to maintain uniform space between external and internal tank in spite of external mechanical shock. However, excessive structure design of internal supports is able to increase the amount of heat conduction and the rate of vaporization. The thermal insulator, filled with space between a external and internal vessel, reduces the rate of heat transfer and guarantees the standing time of cryogenic vessel. Especially powder type of insulator has low thermal conductivity and reduce the specification of structure design. In order to evaluate the effect of insulator on structure design, the experiment set-up simulated cryogenic vessel was tested in shock environment according to thermal insulator. As a result, the behavior of internal support under external shock was understood and the design criteria was able to be suggested.

회전하는 극저온 시스템의 단열 특성에 관한 실험적 연구 (Experimental of the Rotaing Cryogenic System)

  • 이창규;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.7-13
    • /
    • 2000
  • A rotating cryogenic system was designed similar to the cooling system for the rotor of a superconducting generator. The experimental rotor has an inner vessel which simulates the winding space of an actual superconducting rotor, and a torque tube of comparable design. This paper describes the evaluation of the total heat leak into the inner vessel that leads to the study of the heat transfer characteristic of the rotating cryogenic system. To examine the insulation performance of the experimental rotor. temperature was measured at each part of the system at various rotaing speeds from 0 rpm to 600 rpm. Total heat leak into the inner vessel was calculated by measuring the boil-off rate of liquid helium. Conduction heat leak to the inner vessel was obtained by the vent tube, and radiation heat leak was calculated by subtracting the conduction heat lent from the total heat leak. There seemed to be no rotaional dependency of total heat leak at least up 600 rpm.

  • PDF

다단 성형 공정 시 고-Mn 강의 타원형 용기 헤드에서의 변형률 분포: 유한요소해석 (Strain Evolution in High-Mn Steel Ellipsoidal Vessel Head during Multi-forming Process: A Finite Element Analysis)

  • ;;최시훈
    • 소성∙가공
    • /
    • 제32권5호
    • /
    • pp.268-275
    • /
    • 2023
  • ISO 21029 cryogenic vessel is used to transport cryogenic fluids. High-manganese steel (High-Mn steel) is widely regarded as suitable for use at cryogenic temperatures. The conventional way of manufacturing an ellipsoidal vessel head involves incremental stretching, followed by a spinning process. In this study, an alternative method for forming an ellipsoidal vessel head was proposed. Finite element analysis (FEA) was used to theoretically examine the strain evolution during a multi-stage forming process, which involved progressive stretching, deep drawing, and spinning of High-Mn steel. The distribution of effective strain and strain components were analyzed at different regions of the formed part. The FEA results revealed that only normal strains were evident in the dished region of the vessel head due to the stretching process. However, the flange region experienced complex strain evolution during the subsequent deep drawing and spinning process.

Method applied to evaluate heat leakage of cryogenic vessel for liquid hydrogen

  • Li, Zhengqing;Yang, Shengsheng;Wang, Xiaojun;Yuan, Yafei
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권1호
    • /
    • pp.7-11
    • /
    • 2021
  • Cryogenic vessels are special equipment that requires periodic evaluation of their thermal insulation performance. At the current standard, the test is considered as the loss product or heat leakage of cryogenic vessel, which takes over 72 h to evaluate; consequently, a large amount of working medium is discharged to the environment in the process. However, hydrogen is flammable and explosive, and the discharged gas may be dangerous. If liquid hydrogen is replaced with liquid nitrogen before testing, the operation then becomes complicated, and the loss product or heat leakage cannot respond to the thermal insulation performance of cryogenic vessels for liquid hydrogen. Therefore, a novel method is proposed to evaluate the heat leakage of cryogenic vessels for liquid hydrogen in self-pressurization. In contrast to the current testing methods, the method proposed in this study does not require discharge or exchange of working medium in all test processes. The proposed method is based on one-dimensional heat transfer analysis of cryogenic vessels, which is verified by experiment. When this method is used to predict the heat leakage, the comparison with the experimental data of the standard method shows that the maximum error of heat leakage is less than 5.0%.

회전하는 극저온 시스템의 단열 특성에 관한 실험적 연구 (Experimental investigation of the Rotating Cryogenic System)

  • 이창규;정상권
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.63-66
    • /
    • 2000
  • A rotating cryogenic system was designed similar to the cooling system for the rotor of a superconducting generator. The experimental rotor has an inner vessel which simulates the winding space of an actual superconducting rotor, and a torque tube of comparable design. This paper describes the evaluation of the total heat leak into the inner vessel that leads to the study of the jheat transfer characteristic of the rotating cryogenic system.

  • PDF

액체수소 저장탱크용 고효율 지지 시스템 개발 및 해석 (Development and Analysis of the Highly Efficient Support System in a Liquid Hydrogen Vessel)

  • 윤상국;박동훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권4호
    • /
    • pp.363-369
    • /
    • 2007
  • Probably the most significant heat transfer in the cryogenic liquid hydrogen storage tank from the atmosphere may occur through its support system. In this paper the efficient support system for the cryogenic storage vessel was newly developed and analysed. The support system was composed of a spherical ball as a supporter to reduce the contact area. which is located between two supporting SUS tubes inserted SUS and PTFE blocks. Numerical analyses for temperature distribution, and the thermal stress and strain of the support system were performed by the commercial codes FLUENT and ANSYS. The heat transfer rate of the supporter was evaluated by the thermal boundary potential method which can consider the variation of thermal conductivity with temperature. The results showed that the heat transfer rate through the developed supporter compared with the common SUS tube supporter was significantly reduced. The thermal stress and strain were obtained well below the limited values. It was found that the developed supporter can be one of the most efficient support systems for cryogenic liquid storage vessel.

Performance evaluation of 80 GHz FMCW Radar for level measurement of cryogenic fluid

  • Mun, J.M.;Lee, J.H.;Lee, S.C.;Sim, K.D.;Kim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.56-60
    • /
    • 2021
  • The microwave Radar used for special purposes in the past is being applied in various areas due to the technological advancement and cost reduction, and is particularly applied to autonomous driving in the automobile field. The FMCW (Frequency Modulated Continuous Wave) Radar can acquire level information of liquid in vessel based on the beat frequency obtained by continuously transmitting and receiving signals by modulating the frequency over time. However, for cryogenic fluids with small impedance differences between liquid medium and gas medium, such as liquid nitrogen and liquid hydrogen, it is difficult to apply a typical Radar-based level meter. In this study, we develop an 80 GHz FMCW Radar for level measurement of cryogenic fluids with small impedance differences between media and analyze its characteristics. Here, because of the low intrinsic impedance difference, most of the transmitted signal passes through the liquid nitrogen interface and is reflected at the bottom of the vessel. To solve this problem, a radar measurement algorithm was designed to detect multiple targets and separate the distance signal to the bottom of the vessel in order to estimate the precise position on the liquid nitrogen interface. Thereafter, performance verification experiments were performed according to the liquid nitrogen level using the developed radar level meter.

극저온액체 저장용기에서 열전도 차폐단의 영향 (Effect of Vapor-Cooled Heat Stations in a Cryogenic Vessel)

  • 김서영;강병하;최항집
    • 한국수소및신에너지학회논문집
    • /
    • 제9권4호
    • /
    • pp.169-176
    • /
    • 1998
  • Ni/MH 2차전지의 음극용 금속간화합물전극의 부식특성에 미치는 합금원소와 결합제의 영향을 조사하였다. 전극의 재료는 $(LM)Ni_{4.49}Co_{0.1}Mn_{0.205}Al_{0.205}$$(LM)Ni_{3.6}Co_{0.7}Mn_{0.3}Al_{0.4}$$AB_5$ type합금을 모재로 하였다. 여기에 Si sealant 또는 PTFE를 결합제로 첨가한 것과 원재료 분말에 구리를 20% 무전해도금한 것을 냉간 압착하여 전극을 제조하였다. 부식특성을 조사하기위해 탈공기된 6M의 KOH 용액에서 동전위법과 순환전위법을 이용하여 부식전류와 전류밀도를 측정하였다. 모재에 Co가 많이 함유되면 전극의 내식성을 향상시키고 Ni이 많이 함유되면 충전과 방전을 반복하는 동안에 전극의 안정성을 저하시켰다. 부식전류밀도는 Si sealant를 결합제로 사용한 전극의 경우가 PTFE를 사용한 전극의 경우보다 낮았고 Cu가 도금된 전극은 내식성에서 가장 우수하게 나타났다.

  • PDF

단열을 고려한 초저온 액체질소 저장 탱크의 지지대 용접부 설계 (Weldment Design of Supports for Cryogenic Storage Tank considering Insulation)

  • 최동준;오정택;정재현;조종래
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권1호
    • /
    • pp.131-136
    • /
    • 2008
  • The double-walled steel vessel with powder insulation in the space between the walls is used to minimize heat transfer by radiation and conduction in cryogenic storage tank. The vacuum required the insulation is much less extreme than with high-vacuum or multilayer insulations. The solid supports are used to bear the weight of the inner container. Thermal and structural analysis of the tank have been carried out to study the effect of vacuum and weldment geometry of the internal supports. Heat flux in wall is increased with increasing of thermal conductivity of perlite. Heat flux and stress of support is not affected by weldment geometry.