• Title/Summary/Keyword: Cryogenic liquid

Search Result 412, Processing Time 0.028 seconds

Finite Element Analysis of the Corrugated Membrane of LNG Storage Tank for Its Geometric Design (LNG 저장탱크용 멤브레인 형상설계를 위한 유한요소해석)

  • 김성원;이성우;이중남
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.620-624
    • /
    • 1997
  • Corrugated membranes which are used as a means of liquid- and gas-sealing for a LNG storage tank and provide one of the most reliable primary barrier are the main component of in-ground membrane types for the assurance of high safety. It absorbs large thermal and mechanical deformations caused by ultra low temperature of LNG, -162 .deg.c, the cryogenic liquid and mechanical deformations caused by was carried out on crossing corrugation by commercial F.E code, ANSYS. This paper presents some of results in stress analysis of membranes performed for the purpose to investigate the strength of existing membrane for LNG storage tank designed by IHI,MHI, KHI and KGC expect for Technigaz eariy published. Based on these analytical studies,design criteria were estabilished and SHI original membranes having a high level of safety and fitting to larger capacities were developed.

  • PDF

Study of Partial Discharge Influence on AC Breakdown Strength of Laminated Ploypropylene Paper(PPLP) at Liquid Nitrogen (액체 질소에서의 반합성지 AC 파괴 강도에 미치는 부분 방전의 영향)

  • 안드레프;김수연;이인호;김도운;신두성;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.105-109
    • /
    • 2002
  • The short-term AC breakdown strength of laminated polypropylene insulating Paper (PPLP) has been studied for cold dielectric of high temperature superconductivity power cables. The design and operating conditions of the electrode system for studying of short-term breakdown strength of one-layer and multi-layer PPLP samples are discussed in liquid nitrogen(LN2) state. The influence of various operating factors (geometry and dimension of electrodes, speed of tested voltage, thickness of test sample) on the value of short-term AC breakdown strength at cryogenic temperature has been established.

Dielectric Characteristics of HTS Cable (고온초전도 케이블의 유전 특성)

  • Kwag, Dong-Soon;Kim, Hae-Jong;Cho, Jeon-Wook;Seong, Ki-Chul;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.64-68
    • /
    • 2002
  • According to the increasing power demand for the future construction of many underground cables will be required. However, construction of new ducts for power cables will be more difficult. Therefore, research work for realizing the high temperature superconducting(HTS) cable has advanced, where the development of electrical insulating system at cryogenic temperature is one of the major researches. For an electrical insulation design of HTS cable, it is important to understand not only breakdown but also partial discharge and dielectric loss($tan{\delta}$) in liquid nitrogen/paper composite insulation system. In this paper, we investigated breakdown characteristics in liquid nitrogen/paper composite insulation system for the application to HTS cable. And, we studied the breakdown characteristics of the multi-layer and butt gap of the insulation papers in liquid nitrogen. Also, we measured dielectric loss($tan{\delta}$) of the mini-model Cable made of TERLAM IPP.

  • PDF

Strain Characteristics of a 75 tonf-class Engine for Ground Firing Test (75톤급 엔진 지상 연소 시험 변형율 특성)

  • Yoo, Jaehan;Kim, Jinhyuk;Jeon, Seongmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.126-133
    • /
    • 2018
  • A liquid rocket engine experiences various static loads in flight, such as high pressures due to propellents, thrust and thermal loads due to cryogenic liquid oxygen and combustion gas with extreme vibration. During the engine development stage, structural analyses and investigation on the strain measured from ground firing tests are necessary for determining the structural reliability of the engine. In this study, the strain characteristics, obtained from the ground firing tests of a 75 tonf-class engine, were analyzed.

Operating Conditions Proposal of Bandgap Circuit at Cryogenic Temperature for Signal Processing of Infrared Detector and a Performance Analysis of a Manufactured Chip (적외선 탐색기 신호처리를 위한 극저온 밴드갭 회로 동작 조건 제안 및 제작된 칩의 성능 분석)

  • Kim Yon Kyu;Kang Sang-Gu;Lee Hee-Chul
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.12
    • /
    • pp.59-65
    • /
    • 2004
  • A stable reference voltage generator is necessary to the infrared image signal readout circuit(ROIC) to improve noise characteristics of signal originated from infrared devices, that is, to gain good images. In this paper, bandgap circuit operating at cryogenic temperature of 77K for Infrared image ROIC(readout integrated circuit) was first made. It demonstrates practical use possibility through taking measurements and estimations. Bandgap circuit is a representative voltage reference circuit. Most of bandgap reference circuits which are presented so far operate at room temperature, and their characteristic are not suitable for infrared image ROIC operating at liquid nitrogen temperature, 77K. To design bandgap circuit operating at cryogenic temperature, suitable circuit is selected and the parameter characteristics of used devices as temperature change are seen by a theoretical study and fitted at liquid temperature with considering such characteristics. This circuit has been fabricated in the Hynix 0.6um standard CMOS process, and the output voltage measured shows that the stability is 1.042±0.0015V over the temperature range of 60K to 110K and is better than bandgap circuits operated at room temperature.

Investigation of helium injection cooling to liquid oxygen chamber (헬륨분사를 통한 액체산소 냉각의 이론적 고찰 및 해석과 시험의 비교)

  • Gwon, O-Seong;Jo, Nam-Gyeong;Jeong, Yong-Gap;Lee, Jung-Yeop
    • Aerospace Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.134-142
    • /
    • 2006
  • Sub-cooling of cryogenic propellant by helium injection is one of the most effective methods for suppressing bulk boiling and keeping sub-cooled liquid oxygen before rocket launch. In order to design the cooling system, understanding of the limitations of heat and mass transfer is required. In this paper, an analytical model for the helium injection system is presented. This model's main feature is the representation of bubbling system using finite-rate heat transfer and instantaneous mass transfer concept. With this simplified approach, the effect of helium injection to liquid oxygen system under several circumstances is examined. Experimental results along with simulations of single bubble rising in liquid oxygen and bubbling system are presented with various helium injection flow rates, and with change of oxygen chamber pressure.

  • PDF

The discharge characteristics for various electrode shapes under negative high-voltagein in Liquid $SF_6$ ((-)전압 인가시 액체 $SF_6$의 전극형상에 따른 절연파괴특성)

  • Choi, Eun-Hyuck;Park, Kwang-Seo;Kim, Lee-Kook;Lee, Kwang-Sik;Do, Dae-Ho;Kim, Jong-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2085-2087
    • /
    • 2005
  • In this paper the experiments of insulation characteristics by temperature change of $SF_6$ gas and liquid $SF_6$ in model GIS(Gas Insulated Switchgear) were described. From this results, the breakdown voltage was increased with a drop of temperature and an increase of the inner pressure in model GIS. The ability of insulation in liquid $SF_6$ was higher than that of the highly pressurized $SF_6$ gas. A liquid $SF_6$ discharge characteristics was caused by bubble formed evaporation of liquid $SF_6$ and bubble caused by high electric emission. It is considered that these result are fundamental data for electric insulation design of superconductor and cryogenic application machinery which will be studied and developed in the future.

  • PDF

Thermal diffusion experiment of impulsive heat in subcooled liquid nitrogen (과냉 액체질소 내에서 순간적 열확산 실험)

  • Choi, J.H.;Ha, J.C.;Byun, J.J.;Chang, H.M.;Kim, H.M.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.65-70
    • /
    • 2006
  • Transient heat transfer caused by an impulsive heating in subcooled liquid nitrogen is investigated experimentally. This study is part of out ongoing efforts directed to a stable cryogenic cooling system lot superconducting fault current limiters (SFCL). A thin heater attached by epoxy on one surface of a GFRP plate is immersed in liquid-nitrogen bath at temperatures between 77 K and 55 K. A strong heat flux up to $150W/cm^2$ is generated lot 100 ms, and the temperature of the heater sulfate is measured as a function of time. The behavior of bubbles on the heating surface can be explained by comparing the measured temperature history for vertical and two horizontal (up and down) orientations. It is concluded that the subcooling of liquid nitrogen below 70 K is very effective in suppressing bubbles, resulting in better thermal protection and faster recovery from an impulsive heat.

A Study on the Geometric Design Parameters for Optimization of Cooling Device in the Magnetocardiogram System (심자도 장비의 냉각장치 특성 최적화를 위한 기하 설계 변수 연구)

  • Lee, Jung-Hee;Lee, Young-Shin;Lee, Yong-Ho;Lim, Hyun-Kyoon;Lee, Sung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.2
    • /
    • pp.153-160
    • /
    • 2010
  • A magnetocardiogram (MCG) is a recording of the biomagnetic signals generated by cardiac electrical activity. Biomagnetic instruments are based on superconducting quantum interference devices (SQUIDs). A liquid cryogenic Dewar flask was used to maintain the superconductors in a superconducting state at a very low temperature (4 K). In this study, the temperature distribution characteristics of the liquid helium in the Dewar flask was investigated. The Dewar flask used in this study has a 30 L liquid helium capacity with a hold time of 5 d. The Dewar flask has two thermal shields rated at 150 and 40 K. The temperatures measured at the end of the thermal shield and calculated from the computer model were compared. This study attempted to minimize the heat transfer rate of the cryogenic Dewar flask using an optimization method about the geometric variable to find the characteristics for the design geometric variables in terms of the stress distribution of the Dewar flask. For thermal and optimization analysis of the structure, the finite element method code ANSYS 10 was used. The computer model used for the cryogenic Dewar flask was useful to predict the temperature distribution for the area less affected by the thermal radiation.

Sampling and Cryogenic Pulverization and Storage of Environmental Samples and Improvement of Operating Procedures in National Environmental Specimen Bank (국가환경시료은행 시료 채취, 분쇄, 저장과 개선방안 고찰)

  • Lee, Jangho;Lee, Jongchun;Kim, Myungjin;Han, Areum;Lee, Eugene;Bade, Rabindra;Kim, Minsung
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.6
    • /
    • pp.823-839
    • /
    • 2012
  • Environmental Specimen Banks (ESBs) are playing pivotal role in monitoring the effect of environmental pollution on the ecosystem based on the retrospective analysis of the representative samples collected regularly and stored in cryogenic condition. In Korea, National Environmental Specimen Bank (NESB) was established in 2009 and the standard operating procedures (SOPs) for sampling, and cryogenic milling and storage had been prepared during 2007-2010. Since then, the tentative SOPs for the seven kinds of specimens (shoots of Red Pine (Pinus densiflora) and Korean Pine (Pinus koraiensis), leaves of Mongolian Oak (Quercus mongolica) and Zelkova Tree (Zelkova serrata), eggs of Feral Pigeon (Columba livia var. domestica), muscles and organs of Common Carp (Cyprinus carpio), and Freshwater Bivalve (Unio (Nodularia) douglasiae)) have been put to test in the field and laboratory as well against the practicality and feasibility. The SOPs were improved by reflecting the findings from the research and the following discussion regarding the selection of specimen (Feral Pigeon suffering from a control management), sample size (a problem of decreasing number of sampling trees related to increasing sampling time) and period (a problem related to a bud growth), and sampling methods etc.. In addition, barcoding system for the management of the specimen information, and monitoring system of the cryogenic storage to regulate the optimum temperature and the liquid nitrogen level were also developed for the efficient and effective control of the samples. Lastly, the safety guide and emergency protocol were augmented to guarantee a safe work environment with the cryogenic facility. These improvements of the SOPs are expected to contribute to more stable operation of the NESB.