• Title/Summary/Keyword: Cryogenic environment

Search Result 152, Processing Time 0.021 seconds

Sampling and Cryogenic Pulverization and Storage of Environmental Samples and Improvement of Operating Procedures in National Environmental Specimen Bank (국가환경시료은행 시료 채취, 분쇄, 저장과 개선방안 고찰)

  • Lee, Jangho;Lee, Jongchun;Kim, Myungjin;Han, Areum;Lee, Eugene;Bade, Rabindra;Kim, Minsung
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.6
    • /
    • pp.823-839
    • /
    • 2012
  • Environmental Specimen Banks (ESBs) are playing pivotal role in monitoring the effect of environmental pollution on the ecosystem based on the retrospective analysis of the representative samples collected regularly and stored in cryogenic condition. In Korea, National Environmental Specimen Bank (NESB) was established in 2009 and the standard operating procedures (SOPs) for sampling, and cryogenic milling and storage had been prepared during 2007-2010. Since then, the tentative SOPs for the seven kinds of specimens (shoots of Red Pine (Pinus densiflora) and Korean Pine (Pinus koraiensis), leaves of Mongolian Oak (Quercus mongolica) and Zelkova Tree (Zelkova serrata), eggs of Feral Pigeon (Columba livia var. domestica), muscles and organs of Common Carp (Cyprinus carpio), and Freshwater Bivalve (Unio (Nodularia) douglasiae)) have been put to test in the field and laboratory as well against the practicality and feasibility. The SOPs were improved by reflecting the findings from the research and the following discussion regarding the selection of specimen (Feral Pigeon suffering from a control management), sample size (a problem of decreasing number of sampling trees related to increasing sampling time) and period (a problem related to a bud growth), and sampling methods etc.. In addition, barcoding system for the management of the specimen information, and monitoring system of the cryogenic storage to regulate the optimum temperature and the liquid nitrogen level were also developed for the efficient and effective control of the samples. Lastly, the safety guide and emergency protocol were augmented to guarantee a safe work environment with the cryogenic facility. These improvements of the SOPs are expected to contribute to more stable operation of the NESB.

Study on Numerical Analysis for Structural Safety Verification of Overflow Preventer System for LNG Tank (LNG탱크 수위 넘침 방지 시스템의 구조 안전성을 검증하기 위한 수치 해석에 관한 연구)

  • Ryu, Young-Chun;Park, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.1801-1806
    • /
    • 2014
  • This paper proposed the design technology for the level meter of the overflow preventer system of LNG storage tank. The parts of LNG ship should be developed under considering the cryogenic environment. Therefore, we proposed the structure of level meter to prevent overflow of LNG tank using the numerical analysis method. The proposed level meter for the overflow preventer is manufactured and the performance is verified through international authorized inspection agency.

APPLICATION OF ACOUSTIC EMISSION FOR DIAGNOSIS OF QUENCH IN SUPER CONDUCTIVE MAGNET AT CRYOGENIC TEMPERATURE

  • Lee, Joon-Hyun;Lee, Min-Rae;Kwon, Young-Kin;Song, Bong-Min
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.160-165
    • /
    • 2007
  • It is well recently recognized that quench is one of the serious problems for the integrity of superconducting magnets, which is mainly attribute to the rapid temperature rising in the magnet due to some extrinsic factors such as conductor motion, crack initiation etc. In order to apply acoustic emission(AE) technique effectively to monitor and diagnose superconducting magnets, it is essential to identify the sources of acoustic emission. In this paper, an acoustic emission technique has been used to monitor and diagnose quenching phenomenon in racetrack shaped superconducting magnets at cryogenic environment of 4.2K. For these purposes special attention was paid to detect AE signals associated with the quench of superconducting magnets. The characteristics of AE parameters have been analyzed by correlating with quench number, winding tension of superconducting coil and charge rate by transport current.

  • PDF

Disintegration of Cryogenic Jet in Super-critical Environment (초임계 환경으로 분사되는 극저온 제트의 분열)

  • Lee, Keonwoong;Kim, Dohun;Koo, Jaye
    • Journal of ILASS-Korea
    • /
    • v.18 no.3
    • /
    • pp.140-145
    • /
    • 2013
  • Sub/supercritical spray experiments were conducted, and cryogenic nitrogen and gaseous argon were selected for simulants. liquid nitrogen and gaseous argon were injected in subcritical case, and supercritical nitrogen and near-critical gaseous argon were injected in near-critical/supercritical cases. shadowgraph method was used to visualize spray, and analyzed about the breakup length. The breakup length was measured from numbers of Instantaneous shadowgraph Images from each case, and they were compared with momentum flux ratios and density ratios. It was observed that the relation between breakup length and momentum flux ratio was fitted into former experiment results. and the reasonable constant was suggested about the relation between breakup length and density ratio.

Application of Foil Gas Bearing to the 38kW, 100000 RPM Class High Speed Motor (38kW, 100000 RPM 고속모터에 대한 포일 가스 베어링 응용 개발)

  • Kim, Kyeong-Su;Park, Ki-Cheol;Kim, Seung-Woo;Lee, In
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.127-131
    • /
    • 2003
  • Foil gas bearing is a noncontact bearing operated by coupled interaction between hydrodynamic pressure of viscous fluid and elastic deformation of foil structure. It has valuable advantages, such as low power loss, long life, oilless environment and low vibration, over conventional bearings for the high speed applications. A high speed BLDC motor adopting the foil bearing has been developed. It is designed to have 38㎾ power at 100,000 RPM for a cryogenic cooler whose operating fluid is neon. In this paper, structural development details especially for the foil gas bearing and rotordynamics are presented.

  • PDF

Electrical Insulation Design of a 154kV-Class HTS Power Cable

  • Choi, Jin-Wook;Kwag, Dong-Soon;Choi, Jae-Hyeong;Kim, Hae-Jong;Cho, Jeon-Wook;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.2
    • /
    • pp.25-28
    • /
    • 2009
  • A 154kV class high-temperature superconducting (HTS) power cable system is developing in Korea. For insulation design of this cable, it is important that study on cryogenic electrical insulation design to develop the cold dielectric type HTS cable because the cable is operated under the high voltage environment in cryogenic temperature. Therefore, this paper describes a design method for the electrical insulation layer of the cold dielectric type HTS cable adopting the partial discharge-free design under ac stress, based on the experimental results such a ac breakdown strength, partial discharge inception stress, $V_{ac}$-t characteristics, $V_{imp}$-n characteristics, and impulse breakdown strength of liquid nitrogen/laminated polypropylene paper (LPP) composite insulation system in which the mini-model cable is immersed into pressurized liquid nitrogen.

Application of Acoustic Emission Technique for On-Line Monitoring of Quench in Racetrack Superconducting Coil at Cryogenic Environment (음향방출기법을 이용한 극저온 환경하에서 초전도 계자코일의 퀀칭탐지 적용에 관한 연구)

  • Lee, Min-Rae;Gwon, Yeong-Gil;Lee, Jun-Hyeon;Son, Myeong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.4 s.175
    • /
    • pp.858-865
    • /
    • 2000
  • It is well recently recognized that quench is one of the serious problems for the integrity of superconducting magnets, which is mainly attribute to the rapid temperature rising in the magnet due to some extrinsic factors such as conductor motion, crack initiation etc. In order to apply acoustic emission(AE)echnique effectively to monitor and diagnose superconducting magnets, it is essential to identify the sources of acoustic emission. In this paper, an acoustic emission technique has been used to monitor and diagnose quenching phenomenon in racetrack shaped superconducting magnets at cryogenic environment of 4.2K. For these purposes special attention was paid to detect AE signals associated with the quench of superconducting magnets. The characteristics of AE parameters have been analyzed by correlating with quench number, winding tension of superconducting coil and charge rate by transport current. In addition, the source location of quench in superconducting magnet was also discussed on the basis of correlation between magnet voltage and AE energy.

DC and impulse electrical breakdown characteristics of LPP in liquid nitrogen for a HTS DC cable (고온초전도 DC케이블용 LPP의 액체질소 중 DC 및 임펄스 절연파괴 특성)

  • Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Choi, Jae-Hyeong;Min, Chi-Hyun;Kim, Hae-Jong;Cho, Jeon-Wook;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.3
    • /
    • pp.52-56
    • /
    • 2007
  • A high temperature superconducting (HTS) DC cable is ideal for transmitting large blocks of electrical power over a long distance. However, it must be designed to operate reliably within the constraints of the electrical systems. Therefore, a study of the electrical insulation is important to develop a HTS DC cable because it is operated in a cryogenic high voltage environment. This paper discusses the dielectric constructions of the cable and summarizes the experimental results on the DC and impulse dielectric characteristics of the insulation material. in sheet form and mini-model cable configuration. This shows how to design such insulation to be operated reliably. These studies are essential for the insulation design of a HTS DC cable operated in cryogenic environment.

The Flow Behavior Characteristics of Methane with Phase Change at Low Heat Flux (저열유속에서 상변화를 수반하는 메탄의 유동거동특성)

  • Choi, Bu-Hong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.1
    • /
    • pp.96-103
    • /
    • 2014
  • A liquefied natural gas(LNG) in cryogenic liquid is converted back into gaseous form for distribution to residential and industrial consumers. In this re-gasification process, LNG supplies a plenty of cold thermal energy about $83.7{\times}10^4kJ/kg$. The LNG cold thermal energy is utilized for the re-liquefaction process of cryogenic fluids such as Nitrogen, Hydrogen and Helium, and ice manufacturing process and air-conditioning system in some advanced countries. Therefore, it is also necessary to establish the recovery systems of the LNG cold thermal energy around Incheon, Pyungtaek and Tongyung LNG import terminals in our country. Methane is used as working fluid in this paper, which is the major component of LNG over 85 % by volume, in order to investigate the flow behavior characteristics of LNG with phase change at low heat flux. This paper presents the effects of pipe diameters, pipe inclinations and saturation pressures on the flow boundaries of methane flowing in a cryogenic heat exchanger tube, together with those of nitrogen, propane, R11 and R134a. The outcomes obtained from this theoretical researches are also compared with previous experimental data. It was also found that the effect of pipe inclination on the methane flow boundaries was significant.

Evaluation of Thermal Performance and Mechanical Properties in the Cryogenic Environment of Basalt Fiber Reinforced Polyurethane Foam (현무암 섬유 보강 폴리우레탄폼의 열적 성능 및 극저온 환경에서의 기계적 특성 평가)

  • Jeon, Sung-Gyu;Kim, Jeong-Dae;Kim, Hee-Tae;Kim, Jeong-Hyeon;Kim, Seul-Kee;Lee, Jae-Myung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.4
    • /
    • pp.207-213
    • /
    • 2022
  • LNG CCS which is a special type of cargo hold operated at -163℃ for transporting liquefied LNG is composed of a primary barrier, plywood, insulation panel, secondary barrier, and mastic. Currently, glass fiber is used to reinforce polyurethane foam. In this paper, we evaluated the possibility of replacing glass fiber-reinforced polyurethane foam with basalt fiber-reinforced polyurethane foam. We conducted a thermal conductivity test to confirm thermal performance at room temperature. To evaluate the mechanical properties between basalt and glass-fiber-reinforced polyurethane foam which is fiber content of 5 wt% and 10 wt%, tensile and an impact test was performed repeatedly. All of the tests were performed at room temperature and cryogenic temperature(-163℃) in consideration of the temperature gradient in the LNG CCS. As a result of the thermal conductivity test, the insulating performance of glass fiber reinforced polyurethane foam and basalt fiber reinforced polyurethane foam presented similar results. The tensile test results represent that the strength of basalt fiber-reinforced polyurethane foam is superior to glass fiber at room temperature, and there is a clear difference. However, the strength is similar to each other at cryogenic temperatures. In the impact test, the strength of PUR-B5 is the highest, but in common, the strength decreases as the weight ratio of the two fibers increases. In conclusion, basalt fiber-reinforced polyurethane foam has sufficient potential to replace glass fiber-reinforced polyurethane foam.