• Title/Summary/Keyword: Crush Force

Search Result 24, Processing Time 0.018 seconds

Reinforced Polymer/Clay Nanocomposite Foams with Open Cell Prepared via High Internal Phase Emulsion Polymerization (고내상 에멀션 중합에 의해 제조된 열린 기공을 갖는 고장도 고분자/점토 나노복합 발포체)

  • Song, In-Hee;Kim, Byung-Chul;Lee, Seong-Jae
    • Polymer(Korea)
    • /
    • v.32 no.2
    • /
    • pp.183-188
    • /
    • 2008
  • Reinforced open cell micro structured foams were prepared by the polymerization of high internal phase emulsions incorporating inorganic thickeners. Organoclays were used as oil phase thickener, and sodium montmorillonite was used as aqueous phase thickener. Rheological properties of emulsions increased as oil phase thickener concentration and agitation speed increased, due to the reduced drop size reflecting both competition between continuous and dispersed phase viscosities and increase of shear force. Drop size variation with thickener concentration could be explained by a dimensional analysis between capillary number and viscosity ratio. Upon the foams polymerized by the emulsions, compression properties, such as crush strength and Young's modulus were measured and compared. Among the microcellular foams, the foam incorporated with an organoclay having reactive group showed outstanding properties. It is speculated that the exfoliated silicate layers inside polystyrene matrix, resulting in nanocomposite foam, are the main reason why this foam has enhanced properties.

Diagnosis and Treatment of Occult Lisfranc Injury (족근 중족 관절 잠재의 손상에 대한 진단 및 치료)

  • Chung, Hyung-Jin;Park, Jae-Gu;Kam, Min-Cheol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.1
    • /
    • pp.34-39
    • /
    • 2013
  • Purpose: To evaluate the effectiveness of intraoperative stress test for diagnosis of occult Lisfranc injury. Materials and Methods: Between April 2009 and October 2012, 21 patients with occult Lisfranc injuries underwent intraoperative stress test and internal fixation. There were 11 males and 10 females with an average age of 45.3 years (range, 23~79 years). Injuries were caused by traffic accident in 10 cases, indirect force (twisting injury) in 8 cases, and crush in 2 cases, falling from a height in 1 case. Unstable injuries on stress radiograph in occult injury of Lisfranc joint were treated by open reduction or closed reduction and fixation with cannulated screw or K-wire. Radiological evaluation was assessed according to preoperative and postoperative diastasis between $1^{st}$ and $2^{nd}$ metatarsal base. Results: Assoicated injuries were 9 cases of metatarsal fractures, 6 cases of cuneiform fractures and 6 cases of both metatarsal and cuneiform fractures. Medial and middle column fixation was in 13 cases, and three columns fixation was in 8 cases. Initial diastasis between $1^{st}$ and $2^{nd}$ metatarsal base was 2.8 mm (1.3~4.7 mm) on AP radiograph and postoperative diastasis between $1^{st}$ and $2^{nd}$ metatarsal base was 1.2 mm (0.5~2.4 mm) on AP radiograph. Conclusion: Even there is no sign of clear Lisfranc injury, it is necessary to pay attention and give evaluation on circumstances of occult Lisfranc injuries with metatarsal or cuneiform fractures. Intraoperative stress test is helpful to diagnose an occult Lisfranc injury. For unstable injuries on stress radiographs of occult Lisfranc joint injury, operative treatment with open or closed reduction and internal fixation is useful method.

Management of a traumatic anorectal full-thickness laceration: a case report

  • Fortuna, Laura;Bottari, Andrea;Somigli, Riccardo;Giannessi, Sandro
    • Journal of Trauma and Injury
    • /
    • v.35 no.3
    • /
    • pp.215-218
    • /
    • 2022
  • The rectum is the least frequently injured organ in trauma, with an incidence of about 1% to 3% in trauma cases involving civilians. Most rectal injuries are caused by gunshot wounds, blunt force trauma, and stab wounds. A 46-year-old male patient was crushed between two vehicles while he was working. He was hemodynamically unstable, and the Focused Assessment with Sonography for Trauma showed hemoperitoneum and hemoretroperitoneum; therefore, damage control surgery with pelvic packing was performed. A subsequent whole-body computed tomography scan showed a displaced pelvic bone and sacrum fracture. There was evidence of an anorectal full-thickness laceration and urethral laceration. In second-look surgery performed 48 hours later, the pelvis was stabilized with external fixators, and it was decided to proceed with loop sigmoid colostomy. A tractioned rectal probe with an internal balloon was positioned in order to approach the flaps of the rectal wall laceration. On postoperative day 13, a radiological examination with endoluminal contrast injected from the stoma after removal of the balloon was performed and showed no evidence of extraluminal leak. Rectosigmoidoscopy, rectal manometry, anal sphincter electromyography, and trans-stomic transit examinations showed normal findings, indicating that it was appropriate to proceed with the closure of the colostomy. The postoperative course was uneventful. The optimal management for extraperitoneal penetrating rectal injuries continues to evolve. Primary repair with fecal diversion is the mainstay of treatment, and a conservative approach to rectal lacerations with an internal balloon in a rectal probe could provide a possibility for healing with a lower risk of complications.

Optimization of Manufacturing Condition for Fried Garlic Flake and the Physicochemical Properties (튀긴 마늘 flake 제조조건의 최적화 및 이화학적 특성)

  • Kim, Kyeong-Yee;Lee, Eun-Kyung
    • Korean journal of food and cookery science
    • /
    • v.28 no.6
    • /
    • pp.805-811
    • /
    • 2012
  • This study was carried out in order to optimize the manufacturing condition of fried garlic flakes as well as to investigate the physicochemical properties of the flakes. Fried garlic flake samples were prepared as follows: garlic was sliced by a thickness of 1.5 mm, 2.0 mm, 2.5 mm, which were measured by a thickness gage. The samples were fried in vegetable oil under different temperatures of $140{\sim}150^{\circ}C$, $160{\sim}170^{\circ}C$ and $180{\sim}185^{\circ}C$. The compression strength depending on the height (h) was measured in order to find the thickness effect by the rheometer (force control: 50 N, h: 3.25 mm). Moreover, the sample with 1.5 mm thickness showed crisp phenomena of the split compared with the crush shape of the 2.0 mm and 2.5 mm thick samples. The result of strength for time dependence showed a sample with a thickness of 1.5 mm, which was measured 5~9 times more than the 2.0 mm and 2.5 mm thick samples. We thought the reason that the 1.5 mm sample had less response power equivalent to compression force than the other samples. Alliin has been found to affect the immune responses in the blood, it is a derivative of the amino acid cysteine and is also quite heat stable. The LC system with a UV detection at 210 nm consists of a separation on a Zorbax TMS column and isocratic elution with water and ACN as a mobile phase. The alliin contents of raw and fried garlic flake under $140{\sim}150^{\circ}C$, $160{\sim}170^{\circ}C$ and $180{\sim}185^{\circ}C$ were 18.10 mg/mL, 14.0 mg/mL, 11.6 mg/mL and 11.1 mg/mL, respectively. The decrement of alliin content under different temperature was a small quantity hence, we confirmed that the increasing manufacturing temperature was not affected by the alliin content. Examining for the particle structure of fried garlic flakes by a polarization microscope, the color of the sample treated at $160{\sim}170^{\circ}C$ was pure yellow. Furder, the fiber shaped particle, which has an effect on the tough texture, almost did not appear compared to the different temperature conditions. Finally, the sensory test for the preference of fried garlic flake under different conditions was carried out and the scores for various sensory characteristics were surveyed. According to the physicochemical measurements and sensory evaluation, we confirmed that the optimum manufacturing condition of fried garlic flake was 1.5 mm thick at a temperature of $160{\sim}170^{\circ}C$.