• Title/Summary/Keyword: Crown%2C dental

Search Result 77, Processing Time 0.025 seconds

Study on the Casting Ability of Ni-Cr Alloys for Crown and Bridge (관교의치용 Ni-Cr 합금의 주조성에 관한 연구)

  • Lee, In-Kyu;Kim, Yun-Su
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.47-54
    • /
    • 1988
  • The purpose of this study is to evaluate the castability of Ni-Cr alloys for crown and bridge. New young, Hi-Crown and CB-80 which are widely used in dental laboratory were chosen, casting and increased the temperature of furnace 100$^{\circ}C$ of each 7 grades from 600$^{\circ}C$ to 1200$^{\circ}C$. The results are as follows : 1. CB-80 is the most prominent castability among the three Ni-Cr alloys which are Hi-Crown, New-young and Hi-Cr. 2. The good burning temperatures of casting for CB-8p are 900$^{\circ}C$, 100$^{\circ}C$ and 1100$^{\circ}C$ which are obtained four complate casting body of five former patterns. 3. The most proper burning temperature for three Ni-Cr alloys is 900$^{\circ}C$.

  • PDF

Research for the Standard Model of the Items of the National Qualification Examination for the Dental Technician (치과기공사국가시험 문항개발기준안연구)

  • Lee, Duck-Hye;Chung, In-Sung;Han, Chang-Sik
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.75-93
    • /
    • 2002
  • This research was preformed for the purpose of preparing the items of standard model of the national dental technician test base on the duty analysis of the dental technician. The results of the duty analysis for the dental technician follows. 1. The dental technician is a profession to make the oral function smooth through the dental supplement and equipment in a scientific method and the skilled technique. 2. The duty of the dental technician are determined as A. preparation for manufacture B. manufacture C. management of the place of the dental technology D. self-development. A. The field of "the preparation for manufacture" are determined as 1. to confirm work authorization 2. To confirm the working model, B. The field of "In manufacture" are determined as 1. to manufacture the temporary crown 2. to manufacture the inlay and crown & bridge prosthesis 3. to manufacture the porcelain fused metal crown prosthesis 4. to manufacture the all ceramic crown prosthesis 5. to manufacture the temporary denture prosthesis 6. to manufacture the partial denture prosthesis 7. to manufacture the complete denture prosthesis 8. to manufacture the attachment prosthesis 9. to manufacture implant prosthesis 10. to manufacture the removable orthodontic device, 11. to manufacture the fixed orthodontic device, 12. to manufacture the orthodontic study cast C. The field of "in management of the dental lab." are determined as 1. management 2. to control the dental lab. D. The field of "In the self-development" are determined as 1. to improve the professionalism 2. self-control. 3. The developing items selected under the duty evaluation of the dental technician are l7s in the manufacture preparation, 1,011s in the manufacture, 7s in the management for the dental technology, 5s in self-development, and in all together 1,040s

  • PDF

Corrosion of the non-beryllium dental casting Ni-Cr alloys for the denture base framework metal and the porcelain-fused-to-metal crown (베릴륨 불포함 치과 주조용 니켈-크롬 합금 중 금속의치상용 합금과 금속소부도재관용 합금의 부식에 관한연구)

  • Kim, Hong-Sik;Song, Jae-Sang;Park, Soo-Chul
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.337-344
    • /
    • 2012
  • Purpose: This study examined the corrosion level by alloy type and pH, and used the corrosion levels as the dental health data. The study utilized one Ni-Cr alloy for the full and removable partial denture metal frameworks and two Ni-Cr alloys for porcelain-fused-to-metal crown, among the non-beryllium dental casting non-precious Ni-Cr alloys. Methods: The alloy specimens were manufactured in $10cm^2$ and stored in the corrosive solution(pH 2.2-4.4) in the electrical water bath($37^{\circ}C$) for seven days. Afterwards, the metal ions were quantitatively analyzed using the ICP. Results: Of the three metal alloys, Bellabond-Plus$^{(R)}$alloy and SOLIBOND N$^{(R)}$alloy, with 22% or higher chrome chemical contents, had higher corrosion resistance than Jdium-100$^{(R)}$alloy with 20% chrome chemical content. In all three alloys, the corrosion of Ni was highest, and metal ion corrosion was higher in the pH 2.2 corrosive solution. Conclusion: Although Ni-Cr alloy was not very corrosive, a Ni-allergic patient should not have Ni-Cr alloy prosthesis. The Ni-Cr alloy for porcelain-fused-to-metal crown should be designed for the dental porcelain to cover the whole crown.

A CLINICAL STUDY OF TRAUMATlC INJURIES OF ANTERIOR TEETH (전치부 외상에 대한 임상적 고찰)

  • Park, Sang-Duk
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.33-40
    • /
    • 1981
  • The more civilized, the more incidence had happened in our daily life, particularly in industrial factories, by traffic accident, and in sports, etc. in the dental field. The accidental trauma is usually involved the teeth and surronuding tissues. And the author intended to study of the traumatic injuries of anterior teeth by individual tooth, age, sex, cause of trauma, and how they were treated. The following results were obtained: 1. The patients with traumatic injuries of the anterior teeth were 1.8% among the total dental out-patients. 2. By the age group, the twenties was most frequent in both sexes, and the teenagers next. 3. The predominant causes of traumatic injuries in the dental field were traffic accident (23.4%), fighting (19.2%), falling (18.5%), and sports (7.3%). 4. In the classification of injuries of the teeth, uncomplicated crown fractures (31.2%), subluxations (14.7%), and the complicated crown fractures (13.2%) were presented. 5. By the individual tooth in the traumatic cases, the upper cental incisors were most frequently injuried (49.8%). 6. In the treatments fillings and endodontic treatments (33.2%), splints (13.5%), extractions (11.7%) were main after care method.

  • PDF

A study on the difference of Ceramic fracture strength according to the metal depth (금속의 두께가 도재의 파절강도에 미치는 영향)

  • Shin, Mu-Hak;Choi, Un-Jae;Kim, Yoong-Won
    • Journal of Technologic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.89-95
    • /
    • 2005
  • In the manufacture of ceramo-metal crown, difference of fracture strength according to the metal depth has been known to be an important influence on enough intensity and internal stress to endure an occlusion-pressure as well as aesthetics of rehabilitating similar colour such as natural teeth. Depth of ceramic material could be determined by that of metal in three groups: first case of thin depth, second case of thick depth, and third case of constant depth. For the enhancement of the fracture strength between metal and ceramic materials and aesthetic satisfaction, a study on the bonding force, fracture strength, and aesthetics have been required more. In this study, therefore metal coping were made in three groups of A, B and C by using both ceramic powder of Norithe and metal of Columbium, which have been used primarily in the market. A group was made in $0.2mm\times10mm\times10mm$, B group was made in $0.4mm\times10mm\times10mm$, and, C group was made in $0.8mm\times10mm\times10mm$, respectively. The number of metal coping in each group was 10, and total sample numbers used in this study were 30 metal copings. After these metal coping tissue were in the process of build-up in 1.5mm constant depth of porcelain, firing, and glazing, the fracture strength about each metal coping tissue was investigated using oil press. It was found that the average values of durable occlusion pressure for separation of ceramic material in the porcelain fused to metal crown (PFM) in the each group showed the increasing order of A group (30 bar), B group (42 bar), and C group (44 bar), respectively. Proper depth of metal coping in the PFM was considered to be 0.4mm in the B group because this metal size showed higher durable property to the occlusion pressure and better coupling strength in the ceramo-metal crown.

  • PDF

A Study on How Cyclic Casting of Base Metal Alloy for Dental Ceramic Crown May Effects upon Its Mechanical Properties and Microstructure (치과 도재용착 주조관용 비귀금속 합금의 반복주조가 기계적 특성 및 미세조직에 미치는 영향)

  • Choi, Un-Jae;Shin, Moo-Hak;Chung, Hee-Sun;Koh, Myoung-Won
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.9-20
    • /
    • 2003
  • Using a nickel-chrome casting alloy called 'Rexillium V' which is also available as base metal alloy for dental ceramic crown, 4 types of mixtures(A, B, C, D) with old and new metal were prepared for cyclic casting. The results of cyclic casting can be outlined as follows: 1. For Vickers hardness after casting, specimen A and D tended to have lower hardness in the course of cyclic casting, while specimen B and C tended to higher hardness. 2. The results of X-ray diffraction analysis showed that major crystal phase contained nickelchrome compounds and carbide. 3. The observation results of SEM photographs after cyclic casting show that there was a significant tendency to have similar structures among experimental groups. 4. The results of EDX analysis after cyclic casting showed that there were little differences in chemical composition between parent metal and base metal alloy. Although industrial nickel-chrome cast alloy did not show any significant change in material properties even through cyclic casting over several times, it is recommended that more there be more in-depth studies on how to detect any potential corrosion, discoloration and toxication of dental ceramic crown implanted in patient's oral cavity.

  • PDF

Evaluating the accuracy (trueness and precision) of interim crowns manufactured using digital light processing according to post-curing time: An in vitro study

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Kim, Dong-Yeon;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.89-99
    • /
    • 2021
  • PURPOSE. This study aimed to compare the accuracy (trueness and precision) of interim crowns fabricated using DLP (digital light processing) according to post-curing time. MATERIALS AND METHODS. A virtual stone study die of the upper right first molar was created using a dental laboratory scanner. After designing interim crowns on the virtual study die and saving them as Standard Triangulated Language files, 30 interim crowns were fabricated using a DLP-type 3D printer. Additively manufactured interim crowns were post-cured using three different time conditions-10-minute post-curing interim crown (10-MPCI), 20-minute post-curing interim crown (20-MPCI), and 30-minute post-curing interim crown (30-MPCI) (n = 10 per group). The scan data of the external and intaglio surfaces were overlapped with reference crown data, and trueness was measured using the best-fit alignment method. In the external and intaglio surface groups (n = 45 per group), precision was measured using a combination formula exclusive to scan data (10C2). Significant differences in accuracy (trueness and precision) data were analyzed using the Kruskal-Wallis H test, and post hoc analysis was performed using the Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. In the 10-MPCI, 20-MPCI, and 30-MPCI groups, there was a statistically significant difference in the accuracy of the external and intaglio surfaces (P<.05). On the external and intaglio surfaces, the root mean square (RMS) values of trueness and precision were the lowest in the 10-MPCI group. CONCLUSION. Interim crowns with 10-minute post-curing showed high accuracy.

A study on the fitness of the margin to recast with a Ni-Cr alloy for full cast crown (전부주조관용 Ni-Cr 합금 재주조에 따른 변연의 적합도에 대한 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • This experimental study was to determine the fitness on each cervical margin of recast using crown base metal alloy. The alloy used in this experimental study was a Ni-Cr alloy(Wirolloy, Bego, Germany) for the fabrication of full cast crown prosthesis. Twenty-five copings were divided into the five groups. And the group A, B, C, D and E were cording successively according to the frequency of recast to five times. Each specimen was recasted without adding new metal. The experimental results were as follows: 1. The group A and B showed good fitness had subtle differences in each cervical margin adaptation, in other words, the mesio and disto cervical margin showed worse adaptation than the bucco and linguo cervical margin. 2. The group C got good fitness in bucco and linguo cervical margins, but the mesio and disto cervical margin showed inaccurate fitness. And I could not get good casting bodies without adding new metal. 3. The group D and E showed bad fitness for each cervical margin. Therefore the group D and E lost its function as a dental restoration.

  • PDF

Mechanical Properties of Alumina-Glass Dental Composites Prepared from Aqueous-Based Tape Casting (수계공정에 의한 알루미나 테이프로 제조한 세라믹 인공치관용 알루미나 유리 복합체의 기계적 물성)

  • 이명현;김대준;이득용;이정훈;김창은
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.10
    • /
    • pp.1123-1131
    • /
    • 1999
  • Alumina-glass composites which are considered as the material of the choice for all dental crown was prepared by aqeous-based tape casting and sintering for 2h at 1120$^{\circ}C$ followed by glass infiltration for 2h at 1100$^{\circ}C$ Biaxial strength and fracture toughness of the composites were evaluated to determine the optimum composition of the tape as a function of the amount of constituent such as alumina binder and plasticizer. The strength and the fracture toughness of the alumina tape increased with increasing the contents of alumina and binder. These observations are consistent with in fluence of the constituents on mean alumuna particle distance in tapes suggesting that high strength of the glass infiltrated alumina composites is related to toughening by crack bowing. The biaxial strength and the fracture toughness of the composite containing the optimum constituent composition were 523 MPa and 3.3 MPa$.$1/2 respectively.

  • PDF

Cone-beam computed tomography for the assessment of root-crown ratios of the maxillary and mandibular incisors in a Korean population

  • Choi, Sung-Hwan;Kim, Jung-Suk;Kim, Cheol-Soon;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.47 no.1
    • /
    • pp.39-49
    • /
    • 2017
  • Objective: This retrospective, cross-sectional study aimed to establish reference data for normal crown and root lengths and the root-crown ratios (R/C ratios) for the mature maxillary and mandibular incisors in a Korean population by using cone-beam computed tomography (CBCT). Methods: We included 672 Korean patients (141 men and 531 women; mean age, $27.2{\pm}7.7years$) who underwent CBCT examinations during various dental treatments. Crown and root lengths and the R/C ratios of the maxillary and mandibular incisors were measured using CBCT data, which were analyzed to detect significant differences between demographic factors as well as sagittal and vertical skeletal or occlusal relationships. Results: Teeth of the same type in each half-arch were symmetrical. The mean R/C ratios varied from 1.1 to 1.2 for the maxillary incisors and from 1.3 to 1.4 for the mandibular incisors. Crown and root lengths were greater in men than in women, regardless of tooth type. Root lengths and R/C ratios for the mandibular incisors were significantly greater in patients with skeletal Class II malocclusion or an excessive overjet than in the other patients. The R/C ratios for the mandibular incisors were lower in patients with an open bite than in those with a normal or deep bite. Moreover, the R/C ratios for the mandibular incisors increased with age. Conclusions: The data obtained in our study can serve as reference values for crown and root lengths and the R/C ratios for the maxillary and mandibular incisors in the Korean population.