• 제목/요약/키워드: Cross-type

검색결과 2,925건 처리시간 0.027초

임펠러 직경비 및 리어가이더 형상변화가 횡류홴 성능에 미치는 실험적 연구 (Experimental Study on the Performance of a Cross-Flow Fan with Various Diameter Ratios of Impeller and Rearguider Shapes)

  • 김형섭;김동원;윤태석;박성관;김윤제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.391-396
    • /
    • 2003
  • A cross-flow fan relatively produces higher dynamic pressure at low speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. The performance of a cross-flow fan is influenced 25% by the impeller, 60% by the rearguider and the stabilizer, and 15% by the heat exchanger. At the low flow rate, there exist a rapid pressure head reduction, a noise increase and an unsteady flow against a stabilizer and a rearguider. The purpose of this study is to investigate the reciprocal relation among each parameter Experiments are conducted to study the effects of a rearguider and a diameter ratio of impeller on the performance analysis of a cross-flow fan. Comparing with the rearguider of radial type, the Archimedes type shows excellent results for various diameter ratios.

  • PDF

패션광고 유형과 패션브랜드 확장, 소비자 혁신성이 광고신뢰도에 미치는 영향 (Effects of type of fashion advertisement, brand extension and consumer innovativeness on advertising credibility)

  • 김선아;황선진
    • 복식문화연구
    • /
    • 제26권5호
    • /
    • pp.714-726
    • /
    • 2018
  • This study investigates the effects of the type of advertisement, brand extension, and consumer innovativeness on the credibility of fashion advertisements. The factorial design is constructed as a 2(type of fashion advertisement: general vs. cross-media) ${\times}2$(consumer innovativeness: high vs. low) ${\times}2$(the type of fashion brand extension: similar vs. dissimilar) three-way mixed design in which consumer innovativeness is the between-subjects variable. Subjects of this study included 210 men and women in their 20s and 30s who resid in Seoul and had SNS experiences. Frequency analysis, credibility analysis, three-way ANOVA, and simple interaction analysis were conducted using the SPSS 20.0 statistics package. The results are as follows: First, the type of fashion advertisement had a significant effect on advertising credibility. Cross-media advertisements had a more positive effect than general advertisements on all of the dependent variables. Also, the type of brand extension and consumer innovativeness showed significant effect on advertising credibility and the interaction effect between the type of fashion advertisement and consumer innovativeness was significant. Lastly, the effect of different types of brand extensions on advertising credibility showed a significant difference according to consumer innovativeness. Thus, a marketing strategy using cross-media advertising is proven to be effective in gaining consumer trust for a fashion brand.

Development of miniature bar-type structural fuses with cold formed bolted connections

  • Guan, Dongzhi;Yang, Sen;Jia, Liang-Jiu;Guo, Zhengxing
    • Steel and Composite Structures
    • /
    • 제34권1호
    • /
    • pp.53-73
    • /
    • 2020
  • A novel all-steel miniature bar-type structural fuse (MBSF) with cold formed bolted connections is developed in this study, which consists of a central energy dissipation core cut from a smooth round bar, an external confining tube and nuts. Three types of cross sections for the central energy dissipation core, i.e., triple-cut, double-cut and single-cut cross sections, were studied. Totally 18 specimens were axially tested under either symmetric or asymmetric cyclic loading histories, where the parameters such as cut cross sectional area ratio, length of the yielding portion and cross sectional type were investigated. Numerical simulation of 2 representative specimens were also conducted. An analytical model to evaluate the bending failure at the elastic portion was proposed, and a design method to avoid this failure mode was also presented. The experimental results show that the proposed MBSFs exhibit satisfactory hysteretic performance under both the two cyclic loading histories. Average strain values of 8% and 4% are found to be respectively suitable for designing the new MBSFs as the ultimate strain under the symmetric and asymmetric cyclic loadings.

Stable Formation of Fruiting Body in Cordyceps bassiana

  • Lee, Je-O;Shrestha, Bhushan;Kim, Tae-Woong;Sung, Gi-Ho;Sung, Jae-Mo
    • Mycobiology
    • /
    • 제35권4호
    • /
    • pp.230-234
    • /
    • 2007
  • In order to breed a Cordyceps bassiana isolate that stably forms fruiting body in artificial cultivation, isolates derived from subculturing and single spores were tested through mating. From C. bassiana EFCC 783, three subcultured isolates EFCC 2830, EFCC 2831 and EFCC 2832 were obtained and fourteen single conidial isolates were obtained from these three subcultured isolates. Two different morphological types were found in the fourteen single conidial isolates. One type was able to form synnemata and another type was not able to form synnemata. Since switch of morphological type was not observed despite their continuous subculturing, cross was performed between the two types and the formation of fruiting body was examined. Ascospores were obtained from a selected fruiting body formed by hybrid of the cross. Self-cross and combinational cross of the ascospore-derived isolates generated hybrids that stably produce high quality fruiting body in artificial media.

파력발전용 횡류형 수력터빈의 노즐형상에 관한 연구 (A Study on the Nozzle Shapes of a Cross-Flow Type Hydro Turbine for Wave Power Generation)

  • 최영도;김창구;김유택;이영호
    • 한국유체기계학회 논문집
    • /
    • 제11권3호
    • /
    • pp.30-35
    • /
    • 2008
  • The purpose of this study is to examine the effect of nozzle shapes on the performance and internal flow characteristics of a cross-flow type hydro turbine for wave power generation. The performance of the turbine is calculated with the variation of rotational speed for 4 types of the nozzle shape using a commercial CFD code. The results show that nozzle shape should be designed considering available head of the turbine. Best efficiencies of the turbine by 4 types of the nozzle shape do not change largely but overall performances varies mainly by the nozzle width. The output power of the cross-flow type hydro turbine changes considerably by the nozzle shape and a partial region of stage 2 in the runner blade passage produces maximum regional output power in comparison with the other runner blade passage areas.

유무기 하이브리드 SiOC 박막의 화학적 이동에 대한 FTIR 스펙트라 분석 (Analysis of FTIR Spectra in Organic Inorganic Hybrid Type SiOC Films)

  • 오데레사
    • 대한전자공학회논문지SD
    • /
    • 제42권6호
    • /
    • pp.17-22
    • /
    • 2005
  • 유무기 하이브리드 SiOC 박막은 차세대 유력한 저유전상수를 갖는 박막이다. SiOC 박막의 결합구조는 FTIR 분석기를 이용하여 화학적 이동이 일어나는 것을 확인하여 분석하였다. 유기화학분야에서의 일반적인 화학적 이동은 red shift에 해당하지만, 하이브리드 타입의 SiOC 박막은 red shift 뿐만 아니라 특이한 경우에 해당하는 blue shift도 관찰되었다. 화학적 이동의 원인은 전기음성도가 큰 원소가 주변에 존재하는 수소결합사이의 상호작용 때문인데, SiOC 박막에서 blue shift는 전자를 많이 포함하는 메틸그룹이 증가함으로 생기는 기공을 만드는 원인을 제공한다. SiOC 박막의 결합구조 역시 2가지 유형의 화학적 이동에 따라서 cross-link 구조와 case-link 구조의 두 가지 유형으로 나타난다. 유량비와 증착할 때 주어지는 열에너지에 따라서 두 가지 결합구조를 나타낸다. cross-link 구조와 cross-link breakage 구조는 박막의 유전상수가 낮아지는 원인 서로 다르며 화학적 물리적인 특성 또한 다르게 나타나는 것을 증명하고 있다. Si-O-C cross-link 구조는 red shift의 원인이 된 수소결합에 의한 원자사이의 길이가 길어지는 효과에 의해 표면접착력이 개선되며, 유전상수 역시 감소하였다.

전산유체역학을 이용한 초저낙차 상황에서의 도립형 횡류수차의 해석 및 설계 최적화 (Computational Analysis of an Inverted-type Cross-flow Turbine for Ultra-low head Conditions)

  • 함상우;하호진;이정완
    • 한국기계가공학회지
    • /
    • 제18권4호
    • /
    • pp.76-86
    • /
    • 2019
  • The cross-flow turbine is a key hydraulic power system that is widely due to low costs, high efficiency, and low maintenance. In particular, the cross-flow turbine considered as the most suitable turbine for low head situations as it is known to operate down to 5 m of water head. However, the conventional cross-flow turbine is unsuitable for ultra-low head situations with less than a 3 m water head. In this study, we propose an inverted-type cross-flow turbine to overcome the limitations of conventional cross-flow turbines under ultra-low head situations. First, we described the limitations of conventional turbines and suggested a new turbine for the ultra-low head circumstances. Second, we investigated the performance of the new turbine using CFD analysis. Results demonstrated the effects of the design parameters, such as number of blades and rotor diameter ratio, on the performance of the suggested turbine. As a result, we developed an inverted-type cross-flow turbine with up to 60% efficiency under low water head conditions.

상악동 아래벽과 상악 대구치 치근사이 위치관계에 관한 방사선학적 연구 (A Radiologic Study of the Relationship of the Maxillary Sinus Floor and Apex of the Maxillary Molar)

  • 윤혜림;박창서
    • 치과방사선
    • /
    • 제28권1호
    • /
    • pp.111-126
    • /
    • 1998
  • In this study, radiographic evaluation was made using panoramic radiography and cross-sectional tomography of SCANORA/sup (R)/ in male and female adults in their 20's on the relationship between the maxillary sinus floor and the apex of the maxillary molar, to test the accuracy and effectiveness of the cross-sectional tomography, and to use this information in the assessment of preop. and postop. root canal treatment, apical surgery, extraction and implantology. Forty-one adults with an average age of 24.4 years were studied using panoramic radiography and cross-sectional tomography. In panoramic view and cross-sectional view, the position of the apices of maxillary molars were classified as separated, contacted, or protruded type; the general shape of the maxillary sinus floor was evaluated horizontally and vertically from cross-sectional tomography. The accuracy of each radiography was tested using maxilla from 5 fresh cadavers from the Anatomy Lab at Yonsei University Dental College, and panoramic view and cross-sectional tomography were taken in the same condition as with the patients. The results were as follows: 1. Panoramic view and cross-sectional view were taken in the maxilla specimen, and the actual distance between the maxillary sinus floor and the tooth apices were measured in the specimen; the median values of the distance from the tooth apices to the maxillary sinus floor in the panoramic view, cross-sectional view and in the actual maxilla specimen were 2.83 mm, 4.51mm, and 4.l5mm, respectively. In the cross-sectional view, the measured distance was close to the actual distance but in the panoramic view, the measured distance was far from the actual distance. 2. When the results of the panoramic view and cross-sectional view were compared, 40.5% of the results agreed with each other in the two radiographic methods and buccal roots of the 2nd molar were the closest to the maxillary sinus floor in the cross-sectional tomography. 3. In cross-sectional view, when the vertical relationship of the maxillary sinus floor and maxillary roots was assessed, in 1st molars, type II (the sinus floor that extends down to the buccolingual furcation area) was predominant, while in 2nd molars, type I (the sinus floor located above the level connecting the buccal and lingual apices) was predominant. In the horizontal relationship, in 1st molars, type II (the lowest floor of the maxillary sinus located in between the buccal and lingual roots) was predominant; in 2nd molars, type I (the lowest floor of the maxillary sinus located on the buccal side of the buccal roots) and type II appeared in similar frequency. In conclusion, the SCANORA/sup (R)/ cross-sectional tomography was more effective than the frequently used panoramic view, in that the relationship of the maxillary molars and maxillary sinus floor can be evaluated more accurately and the buccolingual cross-sectional view can also be observed. And maxillary sinus floor that was close to maxillary 2nd molar had tendency to be located on buccal side than that close to 1st molar. Therefore, cross-sectional tomography is an effective and accurate method to evaluate the position of the teeth in relation to the sinus floor preoperative and can be easily used to diagnose localized periapical lesions. Also, the image quality obtained was quite satisfactory.

  • PDF

Evaluation of the mechanical properties of current biliary selfexpandable metallic stents: axial and radial force, and axial force zero border

  • Wataru Yamagata;Toshio Fujisawa;Takashi Sasaki;Rei Ishibashi;Tomotaka Saito;Shuntaro Yoshida;Shizuka No;Kouta Inoue;Yousuke Nakai;Naoki Sasahira;Hiroyuki Isayama
    • Clinical Endoscopy
    • /
    • 제56권5호
    • /
    • pp.633-649
    • /
    • 2023
  • Background/Aims: Mechanical properties (MPs) and axial and radial force (AF and RF) may influence the efficacy and complications of self-expandable metallic stent (SEMS) placement. We measured the MPs of various SEMSs and examined their influence on the SEMS clinical ability. Methods: We evaluated the MPs of 29 types of 10-mm SEMSs. RF was measured using a conventional measurement device. AF was measured using the conventional and new methods, and the correlation between the methods was evaluated. Results: A high correlation in AFs was observed, as measured by the new and conventional manual methods. AF and RF scatterplots divided the SEMSs into three subgroups according to structure: hook-and-cross-type (low AF and RF), cross-type (high AF and low RF), and laser-cut-type (intermediate AF and high RF). The hook-and-cross-type had the largest axial force zero border (>20°), followed by the laser-cut and cross types. Conclusions: MPs were related to stent structure. Hook-and-cross-type SEMSs had a low AF and high axial force zero border and were considered safest because they caused minimal stress on the biliary wall. However, the increase in RF must be overcome.

간헐적인 낮은강도, 짧은기간의 운동부하가 뒷다리 부유쥐의 Type II근육에 미치는 영향 (Effect of intermittent low-intensity, short duration exercise on Type IImuscle of suspended rats)

  • 최명애;지제근;김은희
    • 대한간호학회지
    • /
    • 제25권2호
    • /
    • pp.193-209
    • /
    • 1995
  • The purpose of this study was to determine the effect of intermittent low - intensity, short duration exercise during hindlimb suspension on the mass, relative weight, myofibrillar protein content, cross-sectional area of Type I and Type II fibers and SDH activity in Type II(plantaris) muscle. To examine the effectiveness of intermittent low-intensity, short duration exercise on mass, myofibrillar protein content and fiber size, the hindlimbs of adult female Wistar rats were suspended(HS) and half of these rats walked on a treadmill for 45 min/day(9 min every 2h) at 5m /min and a 15$^{\circ}$grade (HS-EX). Plantaris wet weight was 19.67% significantly smaller(p<0.005) and relative plantaris weight was 6.25% smaller compared with those of control rats following seven days of hindlimb suspension. Plantaris wet weight and relative plantaris weight increased by 27.66%, 12.22% each through intermit-tent exercise during hindlimb suspension(p<0.005, p<0.05), moreover, plantaris wet weight and relative plantaris weight of the HS-EX rats were similar to those of control rats. Soleus wet weight and relative soleus weight decreased significantly by 31% and 22.0% in the HS rats(p<0.05). Soleus wet weight and relative soleus weight increased by 10.41%, 25.64% respectively through intermittent ex-ercise during hindlimb suspension, furthermore, soleus wet weight and relative weight of the HS-EX rats were closer to those of control rats. Myofibrillar protein content of plantaris and soleus decreased significantly by 51.49%, 59.65% each, following seven days of hindlimb suspension (p<0.005) Myofibrillar protein content of plantaris and soleus increased by 51.79%, 75.47% each with significance through intermittent exercise during hindlimb suspension(p<0.005). Myofibrillar protein content of plantaris and soleus in HS-EX rats was smaller than that of control rats. No change was observed in fiber type percentage following 1 week of hindlimb suspension or exercise during hindlimb suspension. The type I fiber cross-sectional area of both soleus and plantaris muscle was 18.72% and 41.07% lower in the HS than that of the controls (p<0.05, p<.001), that of both muscles was 6.60% and 29. 3% greater in the HS-EX than that of the HS rats. HS plus intermittent low- intensity short duration exercise resulted in Type I fiber cross-sectional area closer to the controls. Type II fiber cross-sectional area of both plantaris and soleus muscle was 22.45% and 22.58% sl nailer in the HS than in the controls, that of both muschles in the HS-EX was 14.10%, 5.78% greater than HS. Intermittent exercise during hindlimb suspension resulted in Type I, II fiber cross-sectional area closer to the control value. There was no change in SDH activity following 1week of hindlimb suspension or exercise during hindlimb suspension in the plantaris muscle. The results suggest that intermittent low intensity short duration exercise can ameliorate Type II muscular atrophy Induced by hindlimb suspension.

  • PDF