• Title/Summary/Keyword: Cross-sensitivity

Search Result 612, Processing Time 0.024 seconds

A PDMS-Coated Optical Fiber Bragg Grating Sensor for Enhancing Temperature Sensitivity

  • Park, Chang-Sub;Joo, Kyung-Il;Kang, Shin-Won;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.329-334
    • /
    • 2011
  • We proposed a poly-dimethylsiloxane (PDMS)-coated fiber Bragg grating (FBG) temperature sensor for enhancing temperature sensitivity. By embedding the bare FBG in a temperature-sensitive elastomeric polymer, the temperature sensitivity of the proposed structure could be effectively improved by 4.2 times higher than those of the conventional bare-type FBG sensors due to the high thermal expansion coefficient of the PDMS. We analyzed the temperature-sensitivity enhancement effect with the increased Bragg wavelength shift in our structure and dependence on the temperature sensitivity with respect to the cross-section area of the PDMS.

Typing of Staphylococcus hyicus subsp. hyicus by staphylococcin sensitivity (Staphylococcin 감수성(感受性)에 의한 Staphylococcus hyicus subsp. hyicus의 균형별(菌型別))

  • Park, Cheong-kyu
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.3
    • /
    • pp.387-391
    • /
    • 1993
  • Strains of Staphylococcus hyicus subsp. hyicus were compared and differentiated by staphylococcin sensitivity. Strains were tested by the cross-streaking method on brain heart infusion agar. From 31 staphylococcin producers, a typing set of 9 producers was selected and used to type all of the strains. All 81 strains of Staph hyicus subsp. hyicus tested were typable and were differentiated into 12 different sensitivity patterns. Strains of the same serotype from different sources could be further subdivided by their staphylococcin sensitivity patterns. Other staphylococcus species could also be typed by use of the 9 standard strains of Staph hyicus subsp. hyicus.

  • PDF

Parametric Analysis and Design Optimization of a Pyrotechnically Actuated Device

  • Han, Doo-Hee;Sung, Hong-Gye;Jang, Seung-Gyo;Ryu, Byung-Tae
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.3
    • /
    • pp.409-422
    • /
    • 2016
  • A parametric study based on an unsteady mathematical model of a pyrotechnically actuated device was performed for design optimization. The model simulates time histories for the chamber pressure, temperature, mass transfer and pin motion. It is validated through a comparison with experimentally measured pressure and pin displacement. Parametric analyses were conducted to observe the detailed effects of the design parameters using a validated performance analysis code. The detailed effects of the design variables on the performance were evaluated using the one-at-a-time (OAT) method, while the scatter plot method was used to evaluate relative sensitivity. Finally, the design optimization was conducted by employing a genetic algorithm (GA). Six major design parameters for the GA were chosen based on the results of the sensitivity analysis. A fitness function was suggested, which included the following targets: minimum explosive mass for the uniform ignition (small deviation), light casing weight, short operational time, allowable pyrotechnic shock force and finally the designated pin kinetic energy. The propellant mass and cross-sectional area were the first and the second most sensitive parameters, which significantly affected the pin's kinetic energy. Even though the peak chamber pressure decreased, the pin kinetic energy maintained its designated value because the widened pin cross-sectional area induced enough force at low pressure.

Development of an Electrical Capacitance Tomography Code for Analysis of Two-Phase Flow in the Rectangular Pipe (사각관 이상유동 분석을 위한 전기적 캐패시턴스 토모그라피 코드 개발)

  • Lee, Kyoung-Hwang;Lee, Jae-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.87-94
    • /
    • 2005
  • A computer code for Electrical Capacitance Tomography (ECT) is developed to sense the cross sectional phase distribution of two-phase flow in the rectangular pipe in which the tomography sensor furnished by the insulated wall, electrodes, and electric field screen. The computer code had two steps for the image reconstruction. In the forward projection step, the sensitivity matrix was constructed based on the electric field calculated by the finite difference method. In the backward projection step, the sensitivity matrix and the measured capacitances were used to reconstruct the cross sectional image. Several algorithms including LBP, TR, ITR, and PLI were employed to find the proper one for the two-phase flow analysis. Since the dielectric constant of the water in two-phase flow is sensitive to the thermal parameter such as, temperature and pressure, the developed code was evaluated to find their accuracy, speed of calculation, and sensitivity to the variation of the dielectric constant. It was found that the iterative methods are superior to the direct methods for the image reconstruction, and the PLI method was the best in the variation of the dielectric constants.

Triazole Fungicides Sensitivity of Sclerotinia homoeocarpa in Korean Golf Courses

  • Lee, Ji Won;Choi, Jihye;Kim, Jin-Won
    • The Plant Pathology Journal
    • /
    • v.33 no.6
    • /
    • pp.589-596
    • /
    • 2017
  • Chemical management of dollar spot in turf may lead to the development of Sclerotinia homoeocarpa populations with reduced fungicide sensitivity. The objective of this study was to investigate resistance of S. homoeocarpa isolates to triazole fungicides and to test cross-resistance among three triazole fungicides. A total of 66 isolates of S. homoeocarpa were collected from 15 golf courses across Korea, and tested via in vitro sensitivity assay against hexaconazole, propiconazole and tebuconazole. $EC_{50}$ values of the isolates to these fungicides were distributed in the range of $0.001-1.1\;a.\;i.\;{\mu}g\;ml^{-1}$. Based on the $EC_{50}$ values, twelve representative strains were selected as sensitive isolates including control and insensitive isolates with respect to each fungicide. At a concentration of $0.1\;a.\;i.\;{\mu}g\;ml^{-1}$ for all fungicides, the selected strains were distinguished as sensitive or resistant isolates with the mycelial growth inhibition rate of 50% as the criterion. The $EC_{50}$ values of resistant strains exposed to hexaconazole, propiconazole and tebuconazole were 20-50 times, 50-70 times, and 77 times greater, respectively, than that of the control strains. Two isolates of S. homoeocarpa S0-41 and Sh14-2-1 showed sensitivity toward all the fungicides used, while two other isolates Sh7-5-1 and Sh2-1-1 showed resistance to all fungicides. Each isolate showed similar resistance to the three types of triazole fungicides, whereby cross-resistance of isolates was confirmed in the present study; all three triazole fungicide combinations displayed significant correlation coefficients equivalent to or greater than 0.8.

Sensitivity of Phytophthora infestans Isolates to Fungicides Metalaxyl and Ethaboxam in Korea

  • Kim, Byung-Sup;Zhang, Xuan-Zhe;Chung, Eun-Kyoung;Kim, Dal-Soo;Chun, Sam-Jae;Park, Woo-Bong
    • The Plant Pathology Journal
    • /
    • v.19 no.3
    • /
    • pp.143-147
    • /
    • 2003
  • Sensitivity of Phytophthora infestans isolates to fungicides metalaxyl and ethaboxam in Korea was examined with 260 isolates for 3 years (9 isolates in 2000,93 isolates in 2001, and 158 isolates in 2002). Both Al and A2 mating types were found from the isolates collected for 3 years. Al mating type was dominant in the population with 8 isolates (88.9%) in 2000, 84 isolates (89.4%) in 2001, and 138 isolates (87.3%) in 2002. Only some isolates from diseased tomatoes in Buyergun and diseased potatoes in Pyeongchanggun were of the A2 mating type. As for metalaxyl sensitivity, 77.0% of the isolates were moderately resistant with 8 isolates (88.9%) in 2000, 73 isolates (77.7%) in 2001, and 120 isolates (75.9%) in 2002. Meanwhile, those found resistant were 1 isolate (11.1%) in 2000, 16 isolates (17.0%) in 2001, and 33 isolates (20.9%) in 2002. Only 5 isolates (3.2%) were sensitive to metalaxyl in 2002. There was no significant difference in the sensitivity among years. As for ethaboxam, no isolate was able to grow at 5.0 $\mu\textrm{g}$ /ml, and only four isolates (1.5 %) grew at 1.0 $\mu\textrm{g}$ /ml with heavy retardation compared with the untreated control. Based on these 3-year results, the minimum inhibitory concentration (MIC) of ethaboxam to p. infestans was determined to be 0.2-1.0 $\mu\textrm{g}$ /ml. Results indicate that resistance development by p. infestans to ethaboxam is not likely to occur in the natural condition. furthermore, there was no indication of cross resistance between metalaxyl and ethaboxam because all the isolates, regardless of classification for their sensitivity to metalaxyl, were not able to grow at 5.0 $\mu\textrm{g}$ /ml of ethaboxam.

Development of an Accelerometer for Measuring Low Frequency Vibration in Bridge (교량에서 발생하는 저주파진동 측정을 위한 가속도계 개발)

  • Park, K.J.;Choi, N.S.
    • Journal of Power System Engineering
    • /
    • v.7 no.2
    • /
    • pp.36-43
    • /
    • 2003
  • In this paper, the strain-gauge type accelerometer is developed. This type of accelerometer has simple structure and cost for manufacturing is cheap, compared with other types of accelerometer such as piezoelectric, capacitance and servo, etc. Also it is very sensitive to the low frequency vibration which is the prominent characteristics of the vibration occurring by vehicles moving across a bridge. Two prototype accelerometers are designed and manufactured based upon the FE(Finite Element) method and static and dynamic calibration tests are performed to check out the linearity, sensitivity and cross sensitivity, etc. Experimental results designate that the proposed accelerometer show reasonable performances compared to the commercial one.

  • PDF

Evaluation of Mechanical Properties of AZ31B for Sheet Metal Forming at Warm and High Temperature (온간, 열간 판재 성형을 위한 AZ31B의 기계적 성질 평가)

  • Choo D. K.;Kim W. Y.;Lee J. H.;Kang C. G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.256-259
    • /
    • 2004
  • In the present study, AZ31B sheets has a bad formability in room temperature, but the formability is improved significantly as increasing the temperature because of rolled magnesium alloy sheet has a hexagonal closed packed structure (HCP) and a plastic anisotropy. In this paper, after tensile test in various temperatures, strain rate, show the tensile mechanical properties, yield and ultimate strength, K-value, work hardening exponent(n), strain rate sensitivity(m). As temperature increased, yield, ultimate strength and K-value, work hardening exponent(n) are decreased but strain rate sensitivity(m) is increased. As cross-head-speed increased, yield, ultimate strength and K-value, work hardening exponent(n) are increased. And according to the temperature, how change the plastic anisotropy factor R. In addition, we observed how temperatures and cross-head-speed effect on microstructure.

  • PDF

Sensitivity Analysis for Flexural Behaviors of PSC Members (프리스트레스트 콘크리트 휨 부재의 민감도 해석)

  • Lee, Jon-Ja;Lee, Bong-Goo;Kim, Min-Joo;Lee, Yong-Hak
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.2
    • /
    • pp.183-194
    • /
    • 2002
  • A general procedure to evaluate the sensitivity of design variables to stresses and strains in PSC flexural members is proposed. To accomplish the purpose of this study, long-term losses including creep, shrinkage, and PS steel relaxation are formulated based on the equilibrium states of the deformed sectional geometry. Thereby, the formulation follows the basic steps which consider the fundamental formulas adopted by CEB-FIP, ACI, and KCI rather than the age adjusted effective modulus concept. Twenty-one design variable including the material and geometrical properties of concrete, nonprestressing steel and prestressing steel, and the geometry of the cross section are considered in the sensitivity analysis. The gradients of the stresses and strains needed for the sensitivity assessment are calculated in a closed format. The derived formulation is applied to the T-type section PSC beam with prestressing and nonprestressing steels for the sensitivity analysis. The analytically calculated sensitivity results are compared with those numerically calculated to ensure the validity of the proposed procedure.

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.