• 제목/요약/키워드: Cross-flow type

검색결과 301건 처리시간 0.026초

자연하안조성을 위한 SWAT-K 모의치 기반 유황 분석 (Analysis of Flow Duration Based on SWAT-K Simulation for Construction of Natural Riparian)

  • 김남원;이정우;정일문;김지태
    • 한국환경과학회지
    • /
    • 제20권11호
    • /
    • pp.1457-1464
    • /
    • 2011
  • In this study, the method of estimating hydrologic information (water depth, submerged period etc.) on the proper selection of construction point and scale as well as vegetation type suggested for the design of natural riparian rehabilitation structure. Long-term comprehensive watershed model SWAT-K(Korea) was applied to this purpose. Flow duration analysis was conducted to analyze the hydrologic characteristics of Pyungchang watershed at which the 'bangtul' construction method was tested. For this purpose 20 years (1989-2008) rainfall runoff analysis was carried out. Based on the simulated daily streamflow data, flow duration curve was made to analyze the flow characteristics, and the water depth hydrograph was made to analyze the water depth distribution at the cross section. Finally, the information for the selection of proper vegetation according to the submerged period is suggested.

Development of a Plate-Fin Type Gas Turbine Recuperator

  • Kwak Jae-Su;Yang In-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제20권7호
    • /
    • pp.1068-1076
    • /
    • 2006
  • A plate-fin type recuperator for a gas turbine/fuel cell hybrid power generation system was designed, manufactured, and tested. Performance analysis shows that the performance of the system is directly affected by the performance of the recuperator. Therefore, the recuperator should be designed and manufactured carefully, and its performance should be tested and verified before it is integrated into the system. In this paper, the developing procedure including designing, manufacturing, and testing of a cross flow plate-fin type recuperator was presented. Performance test results showed that the design requirements of the recuperator were almost satisfied. Based on the test results, improved design to reduce the size of the recuperator was suggested.

수질 측정용 플로우 셀의 오염 모니터링을 위한 평면광도파로 센서 (PLC Optical Sensor for Contamination Monitoring on the Flow-Cell in the Water Quality Measurement System)

  • 한승헌;김태언;정행윤;기현철;김두근;김선훈
    • 한국전기전자재료학회논문지
    • /
    • 제32권6호
    • /
    • pp.472-476
    • /
    • 2019
  • We have proposed a novel planar lightwave circuit (PLC) optical sensor to monitor the contamination in a flow-cell where water is continuously supplied through a water quality measurement system. We designed a PLC chip with a V-shape waveguide and the simulated its function as a sensor for monitoring contamination in a flow-cell using a numerical the FDTD (finite-difference time-domain) analysis. A novel cross type of waveguide was introduced to make the PLC chip of the V-shaped waveguide. The fabricated PLC was cut into the cross waveguide. A change in the optical propagation loss of the PLC sensor was observed after immersing the PLC sensor into city water. It was determined that the propagation loss of the PLC sensor was 3 dB at a wavelength of $1.55{\mu}m$ in the city water for 15 days.

동심축 이중관 구조에서 유동기인진동 특성 고찰 (Investigation of FIV Characteristics on a Coaxial Double-tube Structure)

  • 송기남;김용완;박상철
    • 대한기계학회논문집A
    • /
    • 제33권10호
    • /
    • pp.1108-1118
    • /
    • 2009
  • A Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source of the order of $950^{\circ}C$ for nuclear hydrogen generation, which can produce hydrogen from water or natural gas. A primary hot gas duct (HGD) as a coaxial double-tube type cross vessel is a key component connecting a reactor pressure vessel and an intermediate heat exchanger in the VHTR. In this study, a structural sizing methodology for the primary HGD of the VHTR is suggested in order to modulate a flow-induced vibration (FIV). And as an example, a structural sizing of the horizontal HGD with a coaxial double-tube structure was carried out using the suggested method. These activities include a decision of the geometric dimensions, a selection of the material, and an evaluation of the strength of the coaxial double-tube type cross vessel components. Also in order to compare the FIV characteristics of the proposed design cases, a fluid-structure interaction (FSI) analysis was carried out using the ADINA code.

Ecogeological Description of Sanyang Gotjawal, Jeju Island, Korea

  • Yi, Yun-Jae;Kim, Dae-Shin;Ko, Suk-Hyung;Lee, Keun Chul;Lee, Jung-Sook;Kim, Jong-Shik
    • 한국환경농학회지
    • /
    • 제41권3호
    • /
    • pp.217-221
    • /
    • 2022
  • BACKGROUND: Gotjawal forest on Jeju Island is characterized by uneven topography that developed as a result of freezing-thawing weathering process and irregular substrates caused by numerous lava-flow collapses. Sanyang Gotjawal, located in southwest of Jeju Island, is a well-developed forest with a long history. In addition to photographs, there is a need for a good way to describe the unique features of Gotjawal, including its geology and vegetation. METHODS AND RESULTS: We illustrated the area's natural features using Clip Studio Paint 1.12.0. To reveal its complexity, we separated the vegetation and geological features in the illustrations. CONCLUSION(S): We drew a cross-section of Gotjawal's unique layers, including lava flows. In addition to an eco-geological approach, we described the dominant vegetation and geological characteristics of the three forest layers (trees, shrubs, and herbs) in Gotjawal.

제초제저항성 들잔디(Zoysia japonica Steud.) 이벤트 Jeju Green21의 환경위해성평가 (Environmental risk assessment of genetically modified Herbicide-Tolerant zoysiagrass (Event: Jeju Green21))

  • 배태웅;강홍규;송인자;선현진;고석민;송필순;이효연
    • Journal of Plant Biotechnology
    • /
    • 제38권2호
    • /
    • pp.105-116
    • /
    • 2011
  • Transgenic zoysiagrass (Zoysia japonica Steud.) expressing the bar gene inserted in the plant genome has been generated previously through Agrobacterium tumefaciens-mediated transformation. The GM zoysiagrass (event: JG21) permits efficient management of weed control of widely cultivated zoysiagrass fields, reducing the frequency and cost of using various herbicides for weed control. Now we have carried out the environmental risk assessment of JG21 prior to applying to the governmental regulatory agency for the commercial release of the GM turf grass outside of test plots. The morphological phenotypes, molecular analysis, weediness and gene flow from each test plot of JG21 and wild-type zoysiagrasses have been evaluated by selectively analyzing environmental effects. There were no marked differences in morphological phenotypes between JG21 and wild-type grasses. The JG21 retained its stable integration in the host plant in T1 generation, exhibiting a 3:1 segregation ratio according to the Mendelian genetics. We confirmed the copy number (1) of JG21 by using Southern blot analysis, as the transgenic plants were tolerant to ammonium glufosinate throughout the culture period. From cross-fertilization and gene flow studies, we found a 9% cross-pollination rate at the center of JG21 field and 0% at distances over 3 m from the field. The JG21 and wild-type zoysiagrass plants are not considered "weed" because zoysiagrasses generally are not dominant and do not spread into weedy areas easily. We assessed the horizontal gene transfer (HGT) of the transgene DNA to soil microorganisms from JG21 and wild-type plants. The bar gene was not detected from the total genomic DNA extracted from each rhizosphere soil of GM and non-GM Zoysia grass fields. Through the monitoring of JG21 transgene's unintentional release into the environment, we found no evidence for either pollen mediated gene flow of zoysiagrass or seed dispersal from the test field within a 3 km radius of the natural habitat.

순환식 병류형 곡물건조기 개발 (I) -시작기의 성능시험 - (Development of a Rice Circulating Concurrent-flow Dryer (I) - Performance Test of Pilot Scale Dryer -)

  • 한재웅;금동혁;한종규;김훈;홍상진
    • Journal of Biosystems Engineering
    • /
    • 제31권4호
    • /
    • pp.349-354
    • /
    • 2006
  • This study was performed to evaluate the performances for a concurrent flow rice dryer of pilot scale with devices for circulating rice. The pilot scale dryer with the capacity of 700 kg was developed to obtain design informations for the development of actual scale dryer of holding capacity of 10 tons. Three drying tests were conducted at two temperature levels of $100^{\circ}C\;and\;120^{\circ}C$, and two air flow rates levels of $28.5cmm/m^2\;and\;57.1cmm/m^2$. Drying conditions for Test-1, Test-2 and Test-3 were $100^{\circ}C\;-28.5cmm/m^2,\;120^{\circ}C-28.5cmm/m^2\;and\;120^{\circ}-57.1cmm/m^2}$ respectively. Drying rates were 0.73%(w.b./h) for Test-1, 0.90%(w.b./h) for Test-2 and 1.46%(w.b./h) for Test-3. The crack ratios of brown rice after drying ranged from 2.4% to 8.4%, and increased with the increase of drying rate and airflow rate. The energy consumptions were from 6,225 kJ/kg to 6,993 kJ/kg which was higher than that of conventional cross-flow rice circulating type dryer used in Korea. This results were due to the lower ambient air temperatures of $4.5^{\circ}C\;to\;13.4^{\circ}C$ during drying tests.

직결형 초음속 연소기 시험 설비 개발 (Development of a Direct-Connected Supersonic Combustor Test Facility)

  • 양인영;이경재;이양지;김형모
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.290-293
    • /
    • 2017
  • 스크램젯 엔진용 초음속 연소기 연구를 위한 직결형, 연속식 연소 시험 설비를 개발하였다. 비행체 속도 마하 5, 연소기 입구 유속 마하 2를 가정하고, 시험 대상 연소기의 유로 단면은 높이 32 mm, 폭 70 mm로 가정하여 설비 요구 조건을 결정하였다. 이에 따라 설비는 유동 전압력 548 kPaA, 전온도 1,320 K, 유량 0.776 kg/s로 설계하였다. 설비는 터보형 압축기, 전기 가열기 및 연소식 가열기와 그 하류에 유동 가속을 위해 장착한 마하 2의 2차원 노즐로 구성하였다. 노즐 상류에서 산소를 추가 공급하여 연소식 공기 가열에 의한 산소 감소를 보상하도록 하였다. 배기는 별도의 감압은 하지 않았다. 저압, 저유량에서의 시운전을 수행하였으며, 설계점 운전은 향후 계획 중에 있다.

  • PDF

가압분무기의 성능 평가와 특성 비교 (Analytical Performance Evaluation of Pneumatic Nebulizers and Comparison of Their Characteristics)

  • 박창준;한명섭;송선진;이동수
    • 분석과학
    • /
    • 제15권2호
    • /
    • pp.120-126
    • /
    • 2002
  • 유도결합 플라스마 질량분석기(ICP-MS)와 유도결합 플라스마 원자방출분광기 (ICP-AES)를 이용하여 상업적으로 유통되고 있는 4 종의 분무기(Meinhard, ESI PFA, Cross-flow, Babington)와 한국표준과학연구원(KRISS)에서 직접 제작한 분무기인 KRISS Inert 분무기와 KRISS conespray 분무기의 성능을 평가하였다. 각 분무기의 압력, 시료주입량의 변화에 따른 시료주입 효율을 조사하였으며 ICP-MS와 ICP-AES에 연결하였을 때 시료주입량의 변화에 따른 감도, 안정성, 바탕선 세기, 산화물과 수소화물의 생성 비율을 조사하였다. 시료의 종류, 시료 양의 제한성, 분석기기의 종류, 분석 원소에 따라 가장 적합한 분무기를 선택해야 높은 감도, 낮은 바탕값, 안정한 신호세기 등의 좋은 분석결과를 얻을 수 있음을 알 수 있었다.

네트워크형 터널의 환기해석 방법에 대한 기초연구-비 Hardy-Cross 방법을 중심으로 (A fundamental study on the ventilation analysis method for the network-type tunnel - focused on the none hardy-cross method)

  • 김효규;최판규;류지오;이창우
    • 한국터널지하공간학회 논문집
    • /
    • 제18권3호
    • /
    • pp.291-303
    • /
    • 2016
  • 최근 도시부 지하도로 건설에 따른 터널내 다양한 형태의 분기부가 설계되고 있으며, 이는 기존의 일자형 터널에서의 환기해석 방법과는 다른 해석방법을 요구하고 있다. 그러나 국내외 터널환기 해석방법중 네트워크형 터널에 대한 환기해석에 대한 방법은 설계기준으로 제시되지 않고 있으며, 주로 네트워크용 수치해석 프로그램에 의존하여 설계가 진행되고 있다. 본 연구에서는 수치해석적 방법이 아닌 특성화 방정식에 기초한 네트워크형 터널에 대한 환기해석 방법 중 설계기준으로 적합한 네트워크 모형을 고찰하였다. 기존의 Hardy-Cross 방법은 계산방법이 비교적 간단하고 수계산이 가능한 장점이 있어, 광산통기 및 터널환기 분야에서 폭넓게 적용되어 왔다. 그러나 Tayler 정리에 따른 절단오차 문제 및 대규모 네트워크 환경에서 mesh의 선택 알고리즘에 따른 수렴성 문제가 보고되고 있다. 따라서 본 연구에서는 비 hardy-cross 방법 중 mesh의 구성이 없이도 유량과 압력을 동시에 해석할 수 있는 gradient method로 네트워크형 터널에 대한 환기해석의 적용성을 고찰하였고, 더불어 네트워크형 터널에 대한 환기해석이 가능한 간편한 방법을 제시하는데 그 목적이 있다.