• Title/Summary/Keyword: Cross-National

Search Result 7,519, Processing Time 0.035 seconds

Effects of a Telephone Follow-up Program on Patient Compliance, Urea Kinetic Modeling and Incidence of Infection in Patients with Continuous Ambulatory Peritoneal Dialysis (CAPD) (전화추후관리 프로그램이 복막투석환자의 치료지속이행, 투석적절도와 감염발생도에 미치는 효과)

  • Chon, Si-Ja;Shin, Sug-Kyun;Roh, Young-Sook;Lee, Suk-Jeong;Park, Ai-Hee;Park, Yang-Sook;Park, Young-Mi
    • Journal of Home Health Care Nursing
    • /
    • v.16 no.2
    • /
    • pp.98-107
    • /
    • 2009
  • Purpose: The objective of this study was to identify the effects of a telephone follow-up program on patient compliance, urea kinetic modeling and incidence of infection in patients with continuous ambulatory peritoneal dialysis (CAPD). Method: A pretest-posttest design with a nonequivalent control group was used to examine the effects of a telephone follow-up program for 12 weeks in a group of 39 CAPD patients. The telephone follow-up group of 17 patients received telephone follow-up 10 min once a week for 1 month and 10 min twice a month for 2 months during 12 weeks compared to control group of 22 who patients received usual care. Results: The telephone follow-up group showed no significant changes in patient compliance and urea kinetic modeling, although patients with CAPD receiving a telephone follow-up showed reduced incidence of exit site infection during the intervention compared with the control group. Conclusion: Telephone follow-up program for CAPD patients may decrease the incidence of exit site infection. Future studies with a larger sample be done utilizing diet and exercise reinforcement program combined with telephone follow-up as a nursing intervention for patients with CAPD.

  • PDF

Hindlimb Muscle Atrophy of Rat Induced by Neuropathic Pain (말초신경 손상에 의한 신경병증성 통증으로 유발된 쥐 뒷다리근 위축)

  • Choe, Myoung-Ae;Kim, Kyung-Hwa;An, Gyeong-Ju;Lee, Kyung-Sook;Choi, Jung-An
    • Journal of Korean Biological Nursing Science
    • /
    • v.10 no.1
    • /
    • pp.88-95
    • /
    • 2008
  • Purpose: The purpose of this study was to examine the effect of neuropathic pain by peripheral nerve injury on mass and Type I and II fiber cross-sectional areas on hindlimb muscles of the neuropathic pain model rat. Method: Adult male Sprague-Dawley rats (body weight 200-220 g) were assigned to one of two groups: a neuropathic pain group (n=7) that had a ligation of the left L5 spinal nerve, a control group (n=5), a naive rat without any procedures. Withdrawal threshold, activity, body weight and food intake were measured daily. At 8 days after neuropathic pain, all rats were anesthetized and the soleus and plantaris muscles were dissected from the both hindlimbs. Body weight, food intake, muscle weight and Type I and II fiber cross-sectional area of the dissected muscles were determined. Result: The neuropathic pain group showed a significant decreases (p<.05) as compared with the control rats, in diet intake, body weight, muscle weight and Type II fiber cross-sectional area of the left (affected side) soleus and plantaris muscles, and the right (unaffected side) muscle weight of plantaris and Type II fiber cross-sectional area of the soleus muscle. Conclusion: The hindlimb muscle atrophy occurs in both affected and unaffected side due to neuropathic pain by the peripheral nerve injury. The hindlimb muscle atrophy of the affected side is more pronounced than that of the unaffected side.

  • PDF

ESTIMATION OF ABSORBED DOSE IN OCCLUSAL RADIOGRAPHY (교합방사선사진 촬영시의 흡수선량 계측)

  • Yoo Young Ah;Choi Karp Shik;Lee Sang Han
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.103-112
    • /
    • 1990
  • The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-2l0 Head & Neck Section/sup R/, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70Kvp and 15mA, 1/4 second (8 inch cone) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  • PDF

Developing Customized Phantom for Korean Bone Density Using 3D Printing (3D 프린팅을 이용한 한국인 골밀도 맞춤 팬텀 개발)

  • Lee, Junho;Choi, Kwan-Yong;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.223-229
    • /
    • 2019
  • In order to reduce the radiation exposure dose of the patient and to obtain accurate diagnosis results, the quality control of the diagnostic radiation generator must be conducted periodically In particular, bone density test equipment could be influenced by many factors, and it is far more important because inaccurate measurement would eventually affect the result value. However, the cross-correction phantom of DXA equipment is poorly penetrated due to lack of awareness of the industry and the high cost. Therefore, this study developed a BMD phantom using a 3D printer and Korean BMD phantom with low cost by cross analyzing Korean BMD value from The Korean National Health and Nutrition Examination Survey and evaluated it. The L1, L2, and L3 BMD values of phantoms produced with the 3D printer were measured to be $0.887{\pm}0.006g/cm^2$, $0.927{\pm}0.006g/cm^2$, and $0.960{\pm}0.005g/cm^2$, at 215 mm height and $0.882{\pm}0.011g/cm^2$, $0.914{\pm}0.005g/cm^2$, $0.933{\pm}0.008g/cm^2$ at 155 mm height displaying statistically significant relevance. The result suggests that a proper quality control and cross calibration of DXA device be possible and expected to be an essential data for various medical phantom manufacture development using 3D printer.

An Experimental Study of Tri-arc Rotating Detonation Engine Using Gaseous Ethylene/Oxygen (기체 에틸렌/산소 Tri-arc 회전 데토네이션 엔진 실험연구)

  • Lee, Eun Sung;Han, Hyung-Seok;Choi, Jeong-Yeol
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.25 no.1
    • /
    • pp.19-28
    • /
    • 2021
  • In rotating detonation engine(RDE), only the detonation wave is moving around the outer wall of the combustor. Neither a mechanical part nor flow is rotating in RDE. Thus, the RDE cross section is not necessary to be circular, but arbitrary closed section is possible. A RDE of tri-arc cross section is designed and As an example of an arbitrary cross sectioned RDE, a RDE of tri-arc cross section is designed in this study, and operational and performance characteristics were examined experimentally. The rotation of the detonation wave is confirmed by dynamic pressure sensor and high-speed camera, while the characteristics of the detonation wave were investigated at the concave and convex surfaces. In the present study, the thrust level of 17.0 N to 96.0 N was obtained depending on the mass flow rate.

Analysis of bed change based on the geometric characteristics of channel cross-sections (유로 단면의 기하학적 특성을 이용한 하상변화량 분석)

  • Ko, Joo Suk;Lee, Kyungsu;Kwak, Sunghyun;Lyu, Siwan
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.12
    • /
    • pp.1097-1107
    • /
    • 2020
  • A methodology has been proposed to understand the spatiotemporal changes of the river topography through the longitudinal change of the geometric characteristics of the cross-sections and the properties related thereto. Three-dimensional spatial information of the riverbed was obtained through the detailed bathymetry survey using an acoustic echo sounder for the reach from Gumi Weir to Chilgok Weir in the Nakdong river. Geometric informations for the reference sections were extracted using the acquired bathymetry survey data. By comparing the geometric properties for the reference sections, it was possible to catch the topographic characteristics and its changes over a reach of the channel. Through comparison with past survey data, it was also possible to quantitatively grasp the amount of change in cross-sectional area and volumetric change of riverbed. It is expected that a quantitative evaluation of river topography changes will be possible by applying the method proposed in this study.

Optimization Design of a Waterproof Seal Cross-Section of Automotive Electrical Connectors (자동차 전장 커넥터 방수시일 단면의 최적설계)

  • Kang, KyuTae;Lee, ChaeEun;Kim, HoKyung
    • Tribology and Lubricants
    • /
    • v.37 no.6
    • /
    • pp.224-231
    • /
    • 2021
  • Recently, the waterproofing performance of high-voltage connectors in automotive vehicles has attracted increased interest. In this study, an optimal cross-sectional shape was derived to obtain uniform contact pressure and strain by considering stress relaxation problems caused by initial tension when mounting a seal. A high strain of 52.1 was distributed in the round region, owing to excessive initial tension. The finite element method (FEM) analysis indicated that the strain corresponding to the optimal initial tensile was 11. We adopted six design factors to optimize the seal cross-section and three factors as the main design factors. An orthogonal arrangement table was prepared using Minitab. FEM analyses of 16 study models were conducted to determine the optimized model. The contact pressure of the optimization model is the most evenly distributed while satisfying the waterproof performance of 0.47 MPa. Compared to the initial model, the difference in strain decreases from 35.5% to 19.6%. Finally, the derived cross-sectional shape can reduce the strain of the round region by 33.8% and the differences in the contact pressure at the upper and lower surfaces by 42% and 76%, respectively.

Daily Life Satisfaction in Asia: A Cross-National Survey in Twelve Societies

  • Inoguchi, Takashi;Basanez, Miguel;Kubota, Yuichi;Cho, Sung Kyum;Kheokao, Jantima;Krirkgulthorn, Tassanee;Yingrengreung, Siritorn;Chung, Robert;Cheong, Angus Weng Hin;Sandoval, Gerardo A. Jay;Deshmukh, Yashwant;Shaw, Kanyika;Yu, Ching-Hsin;Zhou, Baohua;Idid, Syed Arabi Bin Syed Abdullah;Gilani, Ijaz Shaffi;Gilani, Bilal I.
    • Asian Journal for Public Opinion Research
    • /
    • v.1 no.3
    • /
    • pp.153-202
    • /
    • 2014
  • Aside from political leaders' popularity rates and the stock exchange index of business firms, ordinary people are highly interested in aspects of daily life, such as housing, income, health, family, food, human relations and work. Cross-national opinion polls on daily-life satisfaction were carried out in Japan, South Korea, Thailand, Hong Kong, Macao, the Philippines, India, Myanmar, Taiwan, China, Malaysia and Pakistan in the fall of 2013 and winter 2014. The percent difference index (PDI) is formulated as the sum of two positive responses (satisfied and somewhat satisfied) minus the sum of two negative responses (dissatisfied and somewhat dissatisfied). Percent difference indices are given according to society and daily-life aspects. For our analysis to go beneath national average and to go beyond national borders, two lines of analysis are carried out. First, the distance between the level of satisfaction of the top and bottom quartiles is given for each society and according to each of the daily-life aspects. Second, the regional sum of satisfaction of the top quartiles and bottom quartiles are shown crossed by daily-life aspects. In this article we confine ourselves to preliminary comparative description and analysis. More solid and deep comparisons will be carried out by local polling leaders of 12 Asian societies in the succeeding issue of the Asian Journal of Public Opinion Research. Nevertheless, two key threads stand out from this preliminary comparisons. First, social relations (family and human relations) stand out as most satisfied aspects of life in most of twelve societies. Second, the need to go beneath national averages and beyond national borders in analyzing cross-national surveys is confirmed. The comparability and validity of cross-national surveys with varying sampling method and survey mode are briefly discussed toward the end of the article.

Difference of holding power of concrete weight used in shellfish shell fishery by its shape characteristics (패류껍질어업에서 사용 중인 멍의 형태적 특성에 따른 고정력의 차이)

  • LEE, Gun-Ho;CHO, Sam-Kwang;KIM, In-Ok;CHA, Bong-Jin;JUNG, Seong-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.54 no.1
    • /
    • pp.25-31
    • /
    • 2018
  • In this study, the differences of holding power according to the shape and weight distribution of concrete weight used in shellfish shell fishery were investigated through the experiments. To investigate the differences in shape, five bar-shaped concrete weights with the same length and different cross-sectional shapes were produced. The sectional shape of each weight was square, triangle, circle, small cross, and large cross (SQ, TR, CI, CR-S, CR-L). Ten rectangular parallelepiped weights with different bottom area and cross-sectional area were produced. To investigate the differences by the weight distribution, the holding power on the square model (SQ) with six 50 g weights at different positions was investigated. All the holding power was obtained by measuring the tensile force generated when the concrete weight was pulled at a constant speed on the sand. As a result, there were no differences in holding power between the ten rectangular weights. However, the experiment on weights with different cross-sectional shapes showed differences in holding power. The holding power was higher in the order of CR-L > CR-S > CI > TR > SQ. In the weight distribution test, the holding power was higher as the front side of the weight was heavier. Generally, the frictional force is the same even if the shape is different, when two objects have the same value in the weight and the roughness. On the other hand, it seems to have a large impact when the shape of the bottom is deformed in the course of pulling the object. Particularly, the larger the degree of protrusion like cruciform weights, the more the holding power increased while deeply digging the bottom. It is also likely that the holding power increases as the front weight increases.

Study on the production and management of aquatic animals : direct detection of Edwardsiella tarda using an enzyme linked immunosorbent assay (수생산물의 생산과 관리에 관한 기초연구 : ELISA법을 이용한 Edwardssiella tarda의 직접 검출)

  • Chung, Soon-Yoon;Sohn, Sang-Gyu;Chung, Joon-Ki;Huh, Min-Do;Jeong, Hyun-Do
    • Journal of fish pathology
    • /
    • v.10 no.2
    • /
    • pp.75-86
    • /
    • 1997
  • Solid phase enzyme linked immunosorbent assay (ELISA) was developed to detect the whole cells of Edwardsiella tarda from infected tissues of flounder. Cross-reaction test was performed by ELISA against fish pathogens such as A. hydrophila ATCC7966. V. anguillarum HYUFP5001, Y, ruckeri 11-4, E. ictaluri and Streptococcus sp. NG8206. Rabbit anti-E, tarda Edk-2 sera highly cross-reacted with A. hydrophila ATCC7966 and V. anguillarum HUFP5001. However, the cross-reaction was removed by using the anti-serum pre-adsorbed with A, hydrophila ATCC7966 FKC. The intra-species cross-reaction among E. tarda isolates was very high. ELISA with the whole cell antigens present in tissue homogenate appeared with highly decreased sensitivity, presumably by the co-coating of lipid or proteins in tissues. Thus, it would be necessary to use the infected tissue homogenates diluted more than 100 times with PBS for diagnosis. Interestingly, compared with the using of FKC antigen, the direct detection of viable cells in tissue homogenate showed more sensitive results with detection limit of $1{\times}10^3$ cells/ml in buffer or diluted tissue homogenate. Consequently, the ELISA method developed in this study was specific, rapid and sensitive for diagnosing edwardsiellosis.

  • PDF