• 제목/요약/키워드: Cross-Flow Velocity

검색결과 548건 처리시간 0.031초

익형의 기하학적 조건에 따른 축류팬의 성능에 관한 연구 (Effects of geometric conditions of blade on Performance of Axial Pan)

  • 안은영;김재원;정은주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 춘계 학술대회논문집
    • /
    • pp.25-29
    • /
    • 2005
  • Axial fan is used for the supplement of large amount of flows. Axial blowers show relatively high efficiency of the system. The present model of axial fan is for cooling a condenser in an air-conditioning unit that exhibits tendency toward compact size. In order to realize the compact model, the width of an axial blade should be cut down in axial distance. Main interest lies on the performance of the axial blowing system with blades having shorter chord length. One of the important design parameters for axial fan is the shape of the blades of it. Design of blades includes the cross-sectional shape and its dimension, including the chord length. We consider two types of blades; one is NACA airfoil with normal chord length and the other is with shortening chord length by $10\%$ of normal airfoil. Axial blower with the modified blades is essential for the compact model of an air-conditioner. The other design parameters are same in the two cases. Using a wind tunnel follows ASHRAE standards carries out evaluation of performance of the system. Detail of flows around the blades is prepared by velocity measurements using PIV. According to performance estimation, the axial blower with short chord blade show quite close to the performance results, including flow rate and pressure rise, of the standard one. The reason of the two similar results is that the flowpatterns depend on Reynolds number based on the chord length of a blade. In this investigation, the critical chord length is found, in which the flows near the airfoil are so unstable and the performance of the system is decreased. A series of figures is for the detail information on the flow.

  • PDF

$CO_{2}$이용 열펌프의 실외열교환기 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Outdoor Heat Exchanger for Heat Pump Using $CO_{2}$)

  • 장영수;이민규;안영산;김영일
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.101-109
    • /
    • 2005
  • The purpose of this study is to investigate the performance of outdoor heat exchanger for heat pump using carbon dioxide. Two types of fin and tube heat exchangers (2 rows for type A and 3 rows for B) are tested. Both heat exchangers have counter-cross flow and 1-circuit arrangement. Test results such as heat transfer rate, pressure drop characteristics and temperature distribution in the heat exchanger are shown with respect to mass flow rate of refrigerant and frontal air velocity For cooling mode, the minimum temperature difference between air and refrigerant of type B is smaller than that of type A by $1^{circ}C$, but the pressure loss of air side is much higher for type B by $29\%$. It is found that a large temperature gradient of carbon dioxide during gas cooling Process Promotes thermal conduction through tube wall and fins which results in degradation of heat transfer performance. For heating mode operation, type B heat exchanger shows higher heat transfer performance compared to type A. However, because pressure loss of refrigerant side of type B is much greater than that of type A, the refrigerant outlet pressure of type B becomes lower than that of type A.

인삼, 홍삼 및 발효 홍삼이 정상인의 뇌혈류, 평균혈압, 맥박수에 미치는 영향 (Effects of Korean Ginseng, Korean Red Ginseng and Fermented Korean Red Ginseng on Cerebral Blood Flow, Cerebrovascular Reactivity, Systemic Blood Pressure and Pulse Rate in Humans)

  • 정동원;홍진우;신원준;박영민;정재한;김창현;민인규;박성욱;정우상;박정미;고창남;조기호;문상관
    • 대한한의학회지
    • /
    • 제27권3호
    • /
    • pp.38-50
    • /
    • 2006
  • Objectives: The aim of this study was to evaluate the effects of Korean ginseng (KG), Korean red ginseng (KRG) and fermented Korean red ginseng (FKRG) extracts on cerebral hemodynamics and to compare distinction of each extract. Methods: Ten healthy male volunteers $(26.0{\pm}1.8yrs)$ participated in the study according to double-blind and cross-over protocols. Each volunteer was blindly administered 500mg of KG, KRG, FKRG extract or placebo (Dextrin). Blinded researchers measured changes of hyperventilation-induced cerebrovascular reactivity (CVR), mean blood flow velocity (MBFV) of middle cerebral arteries (MCAs) and corrected blood flow velocity at $P_{ETCO2}=40mmHg$ (CV40) using transcranial Doppler ultrasound (DWL Co., Germany). Researchers also observed changes of mean blood pressure (MBP), pulse rate (PR) and expiratory $CO_2$ using S/5 Collector (Datex-Ohmeda Co., Finland). The evaluation was performed at basal condition, and repeated at 1, 2, 3, 4 and 5 hours after administration. Results: MBFV and CV40 in the KRG group tended to rise at I hour after administration, while those of the FKRG group tended to rise at 2 hours after administration. CVR increased significantly after 1 hour in the KRG group (p=0.009) and after 2 hours in the FKRG group (p=0.035), respectively. The KG group showed increasing tendency at 4 hours after administration. No group showed significant difference from the placebo in changes of MBP and PR. Conclusions: It is suggested that KG, KRG and FKRG extracts have effects of enhancing CVR and thus of increasing cerebral blood flow in human subjects.

  • PDF

팬의 운전조건에 따른 종류식환기터널 내의 연기거동에 관한 전산유체역학연구 (Flow and smoke behavior of a longitudinal ventilation tunnel with various velocities using computational fluid dynamics)

  • 이주희;권영진;김동은
    • 한국터널지하공간학회 논문집
    • /
    • 제16권1호
    • /
    • pp.105-115
    • /
    • 2014
  • 터널내의 연기거동 및 대피안전성을 평가하기 위하여 수치해석을 수행하였다. 본 연구의 목적은 최근 더욱 길어지고 있는 장대터널의 화재로 인한 연기 및 온도 분포와 안전성을 평가할 수 있는 수치적 방법을 구현하는데 있다. 계산에 사용되는 컴퓨터자원을 최소화하기 위하여 모델로 선정한 터널의 전체길이인 3 km을 사용하는 대신 여러 개의 대피터널이 포함되는 1.5 km만을 해석영역으로 사용하였다. 터널내의 연기거동에 의한 대피자의 안전성을 평가하기 위하여 연기의 밀도에 의한 기시도와 바닥으로부터의 높이를 고려한 SE (smoke environment)값을 사용하였다. 공기 중에 포함된 연기의 밀도는 3차원 전산유체역학을 통하여 구하였다. 이러한 연기 거동에 영향을 미치는 온도분포를 정확하게 모사하기 위하여 터널 벽면을 단열 혹은 일정한 열유속(heat flux) 가정을 사용하는 대신 1차원 열전도(heat conduction)방정식을 이용하여 터널벽면의 온도를 계산하였다. 대피터널간의 거리가 가까울수록 대피자의 안전성은 높아지겠지만 상대적으로 건설비용이 증가하게 된다. 본 연구에서 대피터널의 길이는 250 m로 하였으며 화재 시 제연팬의 운전 조건을 3가지 (팬이 가동되지 않는 조건, 임계풍속이하조건, 임계풍속이상조건)로 나누어 연기의 거동과 온도분포를 고찰하였다. 그리고 화재가 발생한 시간부터 플래쉬오버가 발생한 시간까지의 연기의 거동과 대피자의 상황을 SE를 이용하여 고찰하였다.

정상 염수쇄기의 형상과 흐름 장의 물리적 특성 (The Physical Characteristics of the flow field and the Form of Arrested Salt Wedge)

  • 이문옥
    • 한국해양학회지
    • /
    • 제25권2호
    • /
    • pp.62-73
    • /
    • 1990
  • 장방형 단면의 개수로를 사용하여 정상 염수쇄기가 존재하는 흐름 장의 유동특성 을 파악하기 위한 실험을 수행하였다. 염수쇄기는 전체적으로 매우 안정하여 목시 관측이 용이하였으나, 유속의 측정과 계면파의 관측에는 가시화수법을 이용하였다. 연 직방향의 밀도변화로부터 정의되는 밀도계면은 목시관측에 의한 계면의 대략 0.5 cm정 도 아래에 존재하였으며, 밀도분포는 Hlomboe 모델을 잘 만족하였다. 계면층은 난류강 도 (turbulent intensity)가 매우 극심한 영역으로서 그 두께는 총평균 Richardson수 가 증가함에 따라 감소하는 경향을 보였으며 상층의 약 16% 정도의 크기를 가졌다. 수 로의 횡단면상의 유속분포는 수로측변에 의한 마찰의 영향을 잘 반영하였고, 상층내에 서는 Reyonolds수가 커질수록 연직방향의 유속분포의 균질성이 증가하는 반면 하층은 대체로 방물형(parabolic type)에 가까운 분포를 보였다. 염수쇄기를 쇄기장(L/SUB o/)에 따라 하구부(x/L/SUB o/< 0.3,단 x는 하구로부터의 거리), 중앙부(0.3 0.7) 의 세 구간으로 나누어 생각하는 경우, 연행계수는 중앙부에서 작고 하구부와 선단부에서 크게 나타났다. 또한 하구부나 중앙부는 계면이 대체로 안정하여 내부표면장력파가 팔생하거나 전파하는 반면, 선단부는 매우 불안정 하여 cusping ripple 또는 bursting ripple과 같은 계면파가 발생하였다. 염수쇄기의 형상은 거의 진선적으로, densimetric Froude 수와 Reynolds 수와는 독립이었다.

  • PDF

다양한 첨단 유량 계측기기를 활용한 제주도 하천 유출 비교 분석 (Analysis and Comparison of Stream Discharge Measurements in Jeju Island Using Various Recent Monitoring Techniques)

  • 양성기;김동수;정우열;류권규
    • 한국환경과학회지
    • /
    • 제20권6호
    • /
    • pp.783-788
    • /
    • 2011
  • Different from the main land of South Korea, Jeju Island has been in difficulties for measuring discharge. Due to high infiltration rate, most of streams in Jeju Island are usually in the dried state except six streams with the steady base flow, and the unique geological characteristics such as steep slope and short traveling distance of runoff have forced rainfall runoff usually to occur during very short period of time like one or two days. While discharge observations in Jeju Island have been conducted only for 16 sites with fixed electromagnetic surface velocimetry, effective analysis and validation of observed discharge data and operation of the monitoring sites still have been limited due to very few professions to maintain such jobs. This research is sponsored by Ministry of Land, Transport and Maritime Affairs to build water cycle monitoring and management system of Jeju Island. Specifically, the research focuses on optimizing discharge measurement techniques adjusted for Jeju Island, expanding the monitoring sites, and validating the existing discharge data. First of all, we attempted to conduct discharge measurements in streams with steady base flow, by utilizing various recent discharge monitoring techniques, such as ADCP, LSPIV, Magnetic Velocimetry, and Electromagnetic Wave Surface Velocimetry. ADCP has been known to be the most accurate in terms of discharge measurement compared with other techniques, thus that the discharge measurement taken by ADCP could be used as a benchmark data for validation of others. However, there are still concerns of using ADCP in flood seasons; thereby LSPIV would be able to be applied for replacing ADCP in such flooded situation in the stream. In addition, sort of practical approaches such as Magnetic Velocimetry, and Electromagnetic Wave Surface Velocimetry would also be validated, which usually measure velocity in the designated parts of stream and assume the measured velocity to be representative for whole cross-section or profile at any specified location. The result of the comparison and analysis will be used for correcting existing discharge measurement by Electromagnetic Wave Surface Velocimetry and finding the most optimized discharge techniques in the future.

무기 콜로이드 현탁액의 십자류 정밀여과에 의한 투과유속의 감소거동 (Flux Decline Behavior in Cross-flow Microfiltration of Inorganic Colloidal Suspensions)

  • 남석태;한명진
    • 멤브레인
    • /
    • 제15권4호
    • /
    • pp.338-348
    • /
    • 2005
  • 정밀여과 모세관 막을 이용한 무기 콜로이드 현탁액의 투과유속 감소특성을 검토하였다. 무기 현탁입자의 종류에 따른 투과거동은 알루미나 현탁액의 투과유속이 벤토나이트 현탁액보다 평균 2배정도 컸으며, 운전시간 경과에 따른 투과유속의 감소도 알루미나 현탁액이 벤토나이트 현탁액에 비하여 전체적으로 서서히 감소하는 경향을 보였다. 운전 시간 10분까지의 투과유속 감소율을 나타내는 초기투과유속 감소율은 벤토나이트 현탁액이 알루미나 현탁액보다 더 컸다. 막 투과유속 감소는 케익오염과 세공막힘오염에 기인하며, 막오염 형태에 있어 벤토나이트 현탁액의 세공막힘오염이 알루미나 현탁액 보다 현저히 크게 나타났다. 운전압력 $1.0\;kg_f/cm^2$에서 총 막오염에 대한 성분오염의 비율은 알루미나 현탁액의 경우 완전세공막힘 $9.35\%$, 표준세공막힘 $6.82\%$, 케익여과 $83.832\%$이었다. 순환흐름속도의 증가로 인해 투과유속은 증가하였고, 알루미나 현탁액은 $6.5\%$, 벤토나이트 현탁액은 $13.5\%$ 증가하였다. 세공크기가 $0.34\;{\mu}m$인 막의 투과유속은 세공의 크기가 $0.24\;{\mu}m$인 막보다 컸으며, 세공크기의 증가에 따른 투과유속은 알루미나 현탁액이 1.61배, 벤토나이트 현탁액이 1.76배 증가하였다.

Numerical Simulation of Cavitating Flows on a Foil by Using Bubble Size Distribution Model

  • Ito, Yutaka;Nagasaki, Takao
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.216-227
    • /
    • 2004
  • A new cavitating model by using bubble size distribution based on bubbles-mass has been proposed. Both liquid and vapor phases are treated with Eulerian framework as a mixture containing minute cavitating bubbles. In addition vapor phase consists of various sizes of vapor bubbles, which are distributed to classes based on their mass. The bubble number-density for each class was solved by considering the change of the bubble-mass due to phase change as well as generation of new bubbles due to heterogeneous nucleation. In this method, the bubble-mass is treated as an independent variable, and the other dependent variables are solved in spatial coordinates and bubble-mass coordinate. Firstly, we employed this method to calculate bubble nucleation and growth in stationary super-heated liquid nitrogen, and bubble collapse in stationary sub-cooled one. In the case of bubble growth in super-heated liquid, bubble number-density of the smallest class based on its mass is increased due to the nucleation. These new bubbles grow with time, and the bubbles shift to larger class. Therefore void fraction of each class is increased due to the growth in the whole class. On the other hand, in the case of bubble collapse in sub-cooled liquid, the existing bubbles are contracted, and then they shift to smaller class. It finally becomes extinct at the smallest one. Secondly, the present method is applied to a cavitating flow around NACA00l5 foil. Liquid nitrogen and liquid oxygen are employed as working fluids. Cavitation number, $\sigma$, is fixed at 0.15, inlet velocities are changed at 5, 10, 20 and 50m/s. Inlet temperatures are 90K in case of liquid nitrogen, and 90K and 1l0K in case of liquid oxygen. 110K of oxygen is corresponding to the 90K of nitrogen because of the same relative temperature to the critical one, $T_{r}$=$T/T_c^{+}$. Cavitating flow around the NACA0015 foils was properly analyzed by using bubble size distribution. Finally, the method is applied to a cavitating flow in an inducer of the LE-7A hydrogen turbo-pump. This inducer has 3 spiral foils. However, for simplicity, 2D calculation was carried out in an unrolled channel at 0.9R cross-section. The channel moves against the fluid at a peripheral velocity corresponding to the inducer revolutions. Total inlet pressure, $Pt_{in}$, is set at l00KPa, because cavitation is not generated at a design point, $Pt_{in}$=260KPa. The bubbles occur upstream of the foils and collapse between them. Cavitating flow in the inducer was successfully predicted by using the bubble size distribution.

  • PDF

실험과 해석을 통한 기포저감 시스템의 개발에 대한 연구 (A Study on the Development of Bubble Reduction System through Experimentation and Analysis)

  • 심우빈;유영철;박성영
    • 한국융합학회논문지
    • /
    • 제12권3호
    • /
    • pp.197-204
    • /
    • 2021
  • 본 연구는 유압기계에 사용되는 유압 시스템에서 기포를 저감시킴으로써 효율을 증대시키는 장치에 관한 것이다. 해외 상용품인 기포저감장치의 역설계를 진행하였고, 실험에 용이하게 제품들을 제작하였다. 작동성 실험을 위해 총 3종류의 시스템을 구성하였다. 해외 상용품을 Base Model로 설정하였고, 하강하는 유체의 표면적을 넓히기 위해 회전형 Rotator와 경사형 Rotator를 추가하였으며, 유체를 균등하게 분배해주기 위해 하단부에 슬롯이 파진 환형 균등분배 파트를 추가 적용하였다. 또한 내부 유동경향을 분석하였으며, 유체의 직선적인 흐름을 균등하게 분배시키는 시스템을 1차 개선 모델로 선정하였고, 설계 변수를 적용하여 추가 유동해석을 진행하였다. 1차 개선 모델을 바탕으로 경사형 Rotator의 각도가 45°일 때를 2차 개선 모델로 선정하였다. 이를 기준으로 환형 균등분배 파트의 출구너비를 변수로 설정한 결과, 환형 파트의 하단부 슬롯 직경이 10mm일 때 기포저감 효율이 가장 높았다. 최종적으로 Base Model 대비 평균 단면 유속이 147% 감소한 시스템을 최종 개선 모델로 도출하였다.

자연성기반 홍수완충공간 조성에 따른 홍수위 변화 분석 (Analysis of Flood Level Changes by Creating Nature-based Flood Buffering Section)

  • 류지원;지운;김상혁;장은경
    • 대한토목학회논문집
    • /
    • 제43권6호
    • /
    • pp.735-747
    • /
    • 2023
  • 최근 기후변화로 인한 극한홍수 피해가 급증하고 있어 기존의 홍수관리시설만으로는 홍수피해에 제대로 대응하기 어려운 상황에 직면하고 있다. 이에 본 연구는 이러한 문제에 대처하기 위해 홍수 관리의 자연성 기반 접근 방법 중 하나인 제방 후퇴 및 이설의 효과를 분석하였다. 이를 위해 1차원 수치모델 HEC-RAS를 사용하여 100년 빈도 홍수에 대한 홍수위 및 유속 변화 그리고 최대 홍수위 발생 시점에 대해 분석하였다. 식생 조성 등의 자연성기반 홍수완충공간의 조성 환경 특성을 고려한 조도계수의 선택은 홍수위 변화 분석 결과에 민감하기 때문에 엄격한 기준과 과학적 근거를 기반으로 하였다. 분석결과, 자연기반해법의 홍수완충공간 조성에 따른 홍수위 저감 효과는 상류 구간에서 더 크게 나타났으며, 최대 30 cm의 홍수위가 저감되었다. 일부 홍수터 확장구간에서는 국부적으로 홍수위가 상승하는 현상이 나타나며, 유속 변화는 확장된 통수단면적의 비율에 따라 다양하게 나타났다. 이를 통해 제방 후퇴와 홍수터 확장은 홍수 관리의 효과적인 대안으로 고려될 수 있을 것으로 기대되며, 홍수위 변화, 유속 변화 및 최고 수위 발생 시점에 대한 종합적인 설계가 필요할 것으로 판단된다.