• Title/Summary/Keyword: Cross-Coupling Effect

Search Result 73, Processing Time 0.028 seconds

The association of oral diseases and chronic diseases in Korean adult population (우리나라 성인의 구강질환과 만성질환의 관련성)

  • Cheon, Hye-Won;Yu, Mi-Sun;Choi, Mi-Hye
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.2
    • /
    • pp.235-249
    • /
    • 2012
  • Objectives : The purpose of this research is to use data from the third year of the 4th National Health and Nutrition Examination Survey to study relationship between oral disease and chronic disease that generally persist from 6 months to over a year, or more specifically, circulatory disease, diabetes, and osteoporosis. Methods : Of the data from the third year of the 4th National Health and Nutrition Examination Survey, 7,893 adults over 19 years old who completed medical examination, health survey, and nutrition survey were selected as the final research subjects. Relationship between chronic disease and oral disease was analyzed by cross tabulation (2-test) and logistic regression analysis using SPSSWIN ver 18.0. Results : 1. Differences in the rate of prevalence of periodontal disease and the rate of prevalence of missing teeth were statistically significant with respect to age, gender, marital status, education level, residential area, income level, and occupation. Rate of prevalence of dental caries was statistically significant with respect to age, education level, and income level. 2. After examining the relationship between existence of chronic disease as diagnosed by doctor with oral disease, rate of prevalence of periodontal disease and missing teeth, hypertension, hyperlipidemia, stroke, myocardial infarction, angina, diabetes, and osteoporosis showed statiscally significant difference. 3. Examination of rate of prevalence of chronic disease with respect to oral disease, periodontal disease and missing teeth exerted statistically significant influence on hypertension, hyperlipidemia, stroke, myocardial infarction, angina, diabetes, and osteoporosis (p<0.05), while dental caries did not have statistically significant effect. 4. Analysis of coupling effect of periodontal disease and missing teeth on chronic disease showed that they were related in all chronic diseases examined in this study (hypertension, hyperlipidemia, stroke, myocardial infarction, angina, diabetes, and osteoporosis) (p<0.05). Conclusions : Periodontal disease and missing teeth were found to increase the rate of prevalence of chronic disease.

Design of 5'' True Color FED Driving System (5'' True Color FED 구동시스템 설계)

  • Shin, Hong-Jae;Kwon, Oh-Kyong;Kwack, Kae-Dal
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.5
    • /
    • pp.70-78
    • /
    • 2001
  • We have developed a novel driving system of 5' true color FED using voltage controlled PWM method which has current control effect. The proposed method has the advantage of voltage controlled pulse width modulation method and current control method. Also, we propose a new circuit model of FED subpixel for circuit simulation of FED driving circuits, considering some parasitic effects, i.e., cross talk, line coupling effect and leakage current to the adjacent cathode lines. Output stage of the data driving circuit is optimized using the proposed circuit model. In video data processing, FED controller uses the parallel processing of R.G.B input data, so duty ratio is maximized and brightness of FED increases. With this results, no noise and high quality performance is achieved in display of 5' true color FED.

  • PDF

The Effect of Zirconate Addition on the Joint Properties of Epoxy Adhesive for Car Body Assembly (차체 구조용 에폭시 접착제의 접합부 특성에 미치는 Zirconate 첨가효과)

  • Jeung, Eun-Taek;Lee, Hye-Rim;Lee, So-Jeong;Lim, Chang-Young;Seo, Jong-Dock;Kim, Mok-Soon;Kim, Jun-Ki
    • Journal of Welding and Joining
    • /
    • v.31 no.5
    • /
    • pp.71-76
    • /
    • 2013
  • The effect of zirconate having - NH functional group on the T-peel and lap shear strength of $CaCO_3$ containing structural epoxy adhesive for car body assembly was investigated. Curing behavior of epoxy adhesive samples were investigated by differential scanning calorimeter (DSC) techniques. The addition of zirconate up to 7.5 phr did not affect the curing mechanism of epoxy adhesive. While the small amount of zirconate addition less than 1.1 phr increased the cross-linking density, the excess addition of zirconate resulted in the increase of uncross-linked impurity. From the increase of T-peel and lap shear strength and the change of fracture mode from the adhesive failure to the mixed one, it was considered that the small addition of zirconate was effective in improving the adhesion strength of epoxy adhesive to the adherend and inorganic filler surfaces. The formation of uncross-linked impurity with the excess addition of zirconate was considered to decrease the joint strength by decreasing the cohesive strength of the cured epoxy.

Study on Mixing Condition of the Rubber Composite Containing Functionalized S-SBR, Silica and Silane : I. Effect of Mixing Temperature (변성 S-SBR Silica-Silane 고무복합체의 배합조건에 대한 연구 : I. 배합온도의 영향)

  • Jang, Suk-Hee;Kim, Wook-Soo;Kang, Yong-Gu;Han, Min-Hyun;Chang, Sang-Mok
    • Elastomers and Composites
    • /
    • v.48 no.2
    • /
    • pp.94-102
    • /
    • 2013
  • Characteristics of rubber mixture were evaluated in order to find the optimum mixing conditions of compounds containing silica and silane at various temperatures. With different mixing temperatures of 105, 120, 130, 140 and $160^{\circ}C$, the viscosity of the compound mixed at $105^{\circ}C$ showed a very high viscosity value. Compounds mixed the temperature range from at $120^{\circ}C$ to $140^{\circ}C$ showed lower viscosity than the compound mixed at $105^{\circ}C$. However, the difference was found to be small in those temperature ranges. On the contrary, at the mixing temperature of $160^{\circ}C$, the viscosity of compound increased again. Through the physical and dynamic observations, it was verified that at the mixing temperature below $120^{\circ}C$ only insufficient silica-silane reaction has been obtained. In addition, with the elevated mixing temperature of $160^{\circ}C$, Cross-linking occurred during mixing by the sulfur contained in coupling agent. In the temperature ranges from $120^{\circ}C$ to $140^{\circ}C$, because of the fast coupling reaction at higher temperature, it was thought to be more advantageous during reaction even though the trend of viscosity and dynamic mechanical property was not clear.

Investigation of visible light communication transceiver applicable to both of illumination and wireless communication (조명 및 무선통신이 동시에 가능한 가시광 송수신기에 관한 연구)

  • Song, Seok-Su;Kong, Young-Sik;Park, Jin-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4A
    • /
    • pp.219-226
    • /
    • 2012
  • We investigated the performance of a visible light communication (VLC) transceiver applicable to both of illumination and wireless communication. we considered the visibility of VLC, the easy connection for wireless communication and high-speed transmission and implemented VLC transceiver based on edge-emitting laser diode and silicon photodiode. The proposed VLC transceiver is designated to operate in a full duplex mode at high speed of 120 Mbit/s. The shielding method that is employed as a means to reduce the light cross coupling effect inside the VLC transceiver is proposed and its performance is experimentally measured. We also applied optical antenna to have the larger angle of field of view (FOV) to novel structure of VLC transceiver and examined and analyzed their bit error rate performance, photometric result with respect to the transmission distance, the coverage range and the tilt degree as transmission link characteristic between two transceivers without optical antenna and with optical antenna.

Design and Vibration Analysis of Tri-axis Linear Vibratory MEMS Gyroscope

  • Seok, Seyeong;Moon, Sanghee;Kim, Kanghyun;Kim, Suhyeon;Yang, Seongjin;Lim, Geunbae
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.235-238
    • /
    • 2017
  • In this study, the design of a tri-axis micromachined gyroscope is proposed and the vibration characteristic of the structure is analyzed. Tri-axis vibratory gyroscopes that utilize Coriolis effect are the most commonly used micromachined inertial sensors because of their advantages, such as low cost, small packaging size, and low power consumption. The proposed design is a single structure with four proof masses, which are coupled to their adjacent ones. The coupling springs of the proof masses orthogonally transfer the driving vibrational motion. The resonant frequencies of the gyroscope are analyzed by finite element method (FEM) simulation. The suspension beam spring design of proof masses limits the resonance frequencies of four modes, viz., drive mode, pitch, roll and yaw sensing mode in the range of 110 Hz near 21 kHz, 21173 Hz, 21239 Hz, 21244 Hz, and 21280 Hz, respectively. The unwanted modes are separated from the drive and sense modes by more than 700 Hz. Thereafter the drive and the sense mode vibrations are calculated and simulated to confirm the driving feasibility and estimate the sensitivity of the gyroscope. The cross-axis sensitivities caused by driving motion are 1.5 deg/s for both x- and y-axis, and 0.2 deg/s for z-axis.

Optimal Design of Magnetically Levitated Flywheel Energy Storage System Based on System Stability Using Rigid-Body Model (강체모델 기반 시스템 안정성을 고려한 자기부상 플라이휠 에너지 저장장치의 최적 설계)

  • Kim, Jung-Wan;Yoo, Seong-Yeol;Bae, Yong-Chae;Noh, Myoung-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.3
    • /
    • pp.283-289
    • /
    • 2010
  • Owing to the increasing worldwide interest in green technology and renewable energy sources, flywheel energy storage systems (FESSs) are gaining importance as a viable alternative to traditional battery systems. Since the energy storage capacity of an FESS is proportional to the principal mass-moment of inertia and the square of the running speed, a design that maximizes the principal inertia while operatingrunning at the highest possible speed is important. However, the requirements for the stability of the system may impose a constraint on the optimal design. In this paper, an optimal design of an FESS that not only maximizes the energy capacity but also satisfies the requirements for system stability and reduces the sensitivity to external disturbances is proposed. Cross feedback control in combination with a conventional proportional-derivative (PD) controller is essential to reduce the effect of gyroscopic coupling and to increase the stored energy and the specific energy density.

Numerical simulation in time domain to study cross-flow VIV of catenary riser subject to vessel motion-induced oscillatory current

  • Liu, Kun;Wang, Kunpeng;Wang, Yihui;Li, Yulong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.491-500
    • /
    • 2020
  • The present study proposes a time domain model for the Vortex-induced Vibration (VIV) simulation of a catenary riser under the combination of the current and oscillatory flow induced by vessel motion. In this model, the hydrodynamic force of VIV comprises excitation force, hydrodynamic damping and added mass, which are taken as functions of the non-dimensional frequency and amplitude ratio. The non-dimensional frequency is related with the response frequency, natural frequency, lock-in range and the fluid velocity. The relatively oscillatory flow induced by vessel motion is taken into account in the fluid velocity. Considering that the added mass coefficient and the non-dimensional frequency can affect each other, an iterative analysis is conducted at each time step to update the added mass coefficient and the natural frequency. This model is in detail validated against the published test models. The results show that the model can reasonably reflect the effect of the added mass coefficient on the VIV, and can well predict the riser's VIV under stationary and oscillatory flow induced by vessel motion. Based on the model, this study carries out the VIV simulation of a catenary riser with harmonic vessel motion. By analyzing the bending moment near the touchdown point, it is found that under the combination of the ocean current and oscillatory flow the vessel motion may decrease the VIV response, while increase the excited frequencies. In addition, the decreasing rate of the VIV under vessel surge is larger than that under vessel heave at small vessel motion velocity, while the situation becomes opposite at large vessel motion velocity.

Bio-Derived Poly(${\gamma}$-Glutamic Acid) Nanogels as Controlled Anticancer Drug Delivery Carriers

  • Bae, Hee Ho;Cho, Mi Young;Hong, Ji Hyeon;Poo, Haryoung;Sung, Moon-Hee;Lim, Yong Taik
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.12
    • /
    • pp.1782-1789
    • /
    • 2012
  • We have developed a novel type of polymer nanogel loaded with anticancer drug based on bio-derived poly(${\gamma}$-glutamic acid) (${\gamma}$-PGA). ${\gamma}$-PGA is a highly anionic polymer that is synthesized naturally by microbial species, most prominently in various bacilli, and has been shown to have excellent biocompatibility. Thiolated ${\gamma}$-PGA was synthesized by covalent coupling between the carboxyl groups of ${\gamma}$-PGA and the primary amine group of cysteamine. Doxorubicin (Dox)-loaded ${\gamma}$-PGA nanogels were fabricated using the following steps: (1) an ionic nanocomplex was formed between thiolated ${\gamma}$-PGA as the negative charge component, and Dox as the positive charge component; (2) addition of poly(ethylene glycol) (PEG) induced hydrogen-bond interactions between thiol groups of thiolated ${\gamma}$-PGA and hydroxyl groups of PEG, resulting in the nanocomplex; and (3) disulfide crosslinked ${\gamma}$-PGA nanogels were fabricated by ultrasonication. The average size and surface charge of Dox-loaded disulfide cross-linked ${\gamma}$-PGA nanogels in aqueous solution were $136.3{\pm}37.6$ nm and $-32.5{\pm}5.3$ mV, respectively. The loading amount of Dox was approximately 38.7 ${\mu}g$ per mg of ${\gamma}$-PGA nanogel. The Dox-loaded disulfide cross-linked ${\gamma}$-PGA nanogels showed controlled drug release behavior in the presence of reducing agents, glutathione (GSH) (1-10 mM). Through fluorescence microscopy and FACS, the cellular uptake of ${\gamma}$-PGA nanogels into breast cancer cells (MCF-7) was analyzed. The cytotoxic effect was evaluated using the MTT assay and was determined to be dependent on both the concentration and treatment time of ${\gamma}$-PGA nanogels. The bio-derived ${\gamma}$-PGA nanogels are expected to be a well-designed delivery carrier for controlled drug delivery applications.

The Effect of Nuclear Overhauser Enhancement in Liver and Heart $^{31}P$ NMR Spectra Localized by 2D Chemical Shift Technique (이차원 화학변위 기법을 이용한 간 및 심장 $^{31}P$ 자기공명분광에서의 Nuclear Overhauser 효과에 대한 연구)

  • Ryeom Hun-Kyu;Lee Jongmin;Kim Yong-Sun;Lee Sang-Kwon;Suh Kyung-Jin;Bae Sung-Jin;Chang Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.94-99
    • /
    • 2004
  • Purpose : To investigate the signal enhancement ratio by NOE effect on in vivo $^{31}P$ MRS in human heart muscle and liver. we also evaluated the enhancement ratios of different phosphorus metabolites, which are important in 31P MRS for each organ. Materials and Methods : Ten normal subjects (M:F = 8:2, age range = 24-32 yrs) were included for in vivo $^{31}P$ MRS measurements on a 1.5 T whole-body MRI/MRS system using $^1H-^{31}P$ dual tuned surface coil. Two-dimensional Chemical Shift Imaging (2D CSI) pulse sequence for $^{31}P$ MRS was employed in all $^{31}P$ MRS measurements. First, $^{31}P$ MRS performed without NOE effect and then the same 2D CSI data acquisitions were repeated with NOE effect. After postprocessing the MRS raw data in the time domain, the signal enhancements in percent were estimated from the major metabolites. Results : The calculated NOE enhancement for liver $^{31}P$ MRS were $\alpha-ATP\;(7\%),\;\beta-ATP\;(9\%),\;\gamma-ATP\;(17\%),\;Pi\;(1\%),\;PDE\;(19\%)$ and $PME\;(31\%)$. Because there is no creatine kinase activity in liver, PCr signal is absent. For cardiac $^{31}P$ MRS, whole body coil gave better scout images and thus better localization than surface coil. In $^{31}P$cardiac multi-voxel spectra, DPG signal increased from left to right according to the amount of blood included. The calculated enhancement for cardiac $^{31}P$ MRS were : $\alpha-ATP\;(12\%),\;\beta-ATP\;(19\%),\;\gamma-ATP\;(30\%),\;PCr\;(34\%),\;Pi\;(20\%),\;(PDE)\;(51\%),\;and\;DPG\;(72\%)$. Conclusion : Our results revealed that the NOE effect was more pronounced in heart muscle than in liver with different coupling to 1H spin system and thus different heteronuclear cross-relaxation.

  • PDF