• 제목/요약/키워드: Cross spectrum

검색결과 370건 처리시간 0.025초

크로스 스펙트럼법을 사용한 음향 전달계의 임펄스 응답 추정에서 데이터에 거는 창 함수의 영향 (The Effect of an Window Function Weighted Datas with the Estimated Impulse Response of the Acoustic Transfer System Using Cross-Spectrum Method)

  • 송창용;이유현;김천덕;이채봉
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 2호
    • /
    • pp.147-150
    • /
    • 1999
  • 본 논문에서는 Cross-Spectrum법에 의한 임펄스 응답을 추정할 때의 창함수의 영향을 살펴본다. 여러종류의 창함수에 대해 전달함수의 지연시간과 창함수의 길이의 관계를 조사하고, 측정에 의해 비교 확인하였다. 음향 전달계의 임펄스 응답 추정치의 평가식을 이용하여 창함수중 Riesz 창함수의 추정 정확도가 대체로 양호함을 확인했다.

  • PDF

후향계단 주위의 난류 박리재부착유동에서의 벽압력변동의 통계적 특징 (Cross-Spectral Characteristics of Wall Pressure Fluctuations in Flows over a Backward-Facing Step)

  • 이인원;성형진
    • 대한기계학회논문집B
    • /
    • 제24권2호
    • /
    • pp.280-287
    • /
    • 2000
  • Laboratory measurements were made of wall pressure fluctuations in a separated and reattaching flow over a backward-facing step. An array of 32 microphones along the streamwise direction was utilized. Various statistical properties of pressure fluctuations were scrutinized. The main emphasis was placed on the flow inhomogeneity along the streamwise direction. One point statistics such as the streamwise distribution of rms pressure and autospectra were shown to be generally consistent with other studies. The coherences and wavenumber spectra in the streamwise directions were indicative of the presence of dual modes in pressure; one is the large-scale vortical structure in low frequency and the other is the boundary-layer-like decaying mode in high frequency.

심박변동신호의 시변파워스펙트럼 추정을 위한 Time-Frequency 알고리즘에 관한연구 ("A study on the Time-Frequency Algorithm to estimate time-varying Power Spectrum of Heart Rate Variability Signals")

  • 박찬석;이정환;이준영;김준수;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.185-186
    • /
    • 1998
  • The discrete Wigner-distribution(DWD) was implemented for the time-frequency analysis of heart rate variability signals. The smoothed cross-DWD was used to estimate time-varying power spectrum. Spurious cross-terms were suppressed using a smoothing data window and a Gauss frequency window. The DWD is very easy to implement using the FFT algorithm. Experiment show that the DWD follows well the instantaneous changes of spectral content of heart rate variability signals, which characterize the dynamics of autonomic nervous system response.

  • PDF

누설오차의 영향을 고려한 음향 인텐시티의 추정 (Sound Intensity Estimation with the Effect of Leakage Error from the Contaminated Data)

  • 안세진;정의봉;정호경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.1189-1194
    • /
    • 2002
  • Acoustic intensity is usually estimated by the cross-spectrum of acoustic pressure at two adjacent micrphones. The cross-spectrum calculated by digital Fourier transform technique will unavoidally have leakage error since the period of signal will not be usually coincident with record length. Therefore, the acoustic intensity estimated by the conventional r]n analyzer will show distorted value. In this paper the expression of the Fourier transformed data of a harmonic signal is formulated when there is leakage error. The method to elimate the effect of leakage error from the contaminated data is also proposed. Some numerical examples show the validation of the proposed method.

  • PDF

단일 주파수를 갖는 음향 인텐시티의 누설오차 개선 (Leakage Error Improvement of the Intensity with a single freqency)

  • 정의봉;안세진;정호경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1156-1161
    • /
    • 2001
  • Acoustic intensity is usually estimated by the cross-spectrum of acoustic pressure at two adjacent microphones. The cross-spectrum calculated by digital Fourier transform technique will unavoidally have leakage error since the period of signal will not be usually coincident with record length. Therefore, the acoustic intensity estimated by the conventional FFT analyzer will show distorted value. In this paper, the expression of the Fourier transformed date of a harmonic signal with a single frequency is formated when there is leakage error. The method to elimate the effect of leakage error from the contaminated data is also proposed. Some numerical examples show the validation of the proposed method.

  • PDF

An Experimental Study for Noise Reduction of the Cross-Flow Fan of the Room Air-Conditioners

  • Koo, Hyoung-Mo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.89-100
    • /
    • 2000
  • Present study explains some experimental results on the aerodynamic noise of the cross-flow fan usually installed in the indoor unit of the room air-conditioners and provides a simple reduction method of radiating sound to decrease the total noise level. The spectra of the noise of the cross-flow fan were analyzed by the spectral decomposition method to characterize the generated sound. The unsteady fluctuating flow field was also measured using the I-type hot-wire probe. Comparing the spectral characteristics of the sound and the flow velocity, a useful noise reduction method was proposed, which bounds the region with a fence where the flow fluctuations were noticeably changed in the same fashion as the source spectral distribution functions vary. To validate the proposed method for reducing noise generated by the cross-flow fan, the sound pressure levels of the cross-flow fan system were compared with and without the bounding fence for various flow rates.

  • PDF

에어컨용 직교류홴의 저소음화를 위한 실험적 연구 (An experimental study for noise reduction of the cross-flow fan of the room air-conditioners)

  • 구형모
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.871-879
    • /
    • 1999
  • Present study explains some experimental results on the aerodynamic noise of the cross-flow fan usually installed in the indoor unit of the room air-conditioners and provides a simple reduction method of radiating sound to decrease the total noise level. The spectrums of the noise of the cross-flow fan were analyzed by the spectral decomposition method to characterize the generated sound. The unsteady fluctuating flow field was also measured using the I-type hot-wire probe. Comparing the spectral characteristics of the sound and the flow velocity, a useful noise reduction method was proposed which bounds the region with a fence where the flow fluctuations were noticeably changed in the same fashion as the source spectral distribution functions vary. To validate the proposed method for reducing noise generated by the cross-flow fan, the sound pressure levels of the cross-flow fan system were compared of the experimental rig with and without the bounding fence for various flow rates.

  • PDF

근거리 음압의 공간 변환에 의한 음원의 음장 분포 해석 (Analysis of the Sound Source Field Using Spatial Transformation of the Sound Pressure in a Near-field)

  • 김원호;윤종락
    • 한국음향학회지
    • /
    • 제22권8호
    • /
    • pp.660-669
    • /
    • 2003
  • 본 논문은 음원 근처의 홀로그램 평면에서 측정된 음압에 대한 상호 파워 스펙트럼으로부터 홀로그램 평면에서의 음압 분포를 구하고 획득된 음장을 공간 변환하여 음원의 음장을 구하기 위한 이론을 설명하였으며, 홀로그램 평면에서의 상호 파워 스펙트럼으로부터 모든 지점에서의 음압을 구하기 위해 비선형 방정식에 대한 Taylor 급수를 전개하고 Newton-Raphson 법을 이용하여 계산하는 방법과 음원 영역으로의 역방향 전파시 발생되는 오차를 줄이기 위한 파수 필터를 제시하였다. 무한 배플 내의 원판형 진동체 수중 음원에 대한 모의실험을 통해 결과를 고찰하고 제시된 이론을 검증하였다.

선형예측부호화 스펙트럼을 이용한 유발이음청 방재파의 잠시측정 (Mesurement of Evoked Otoacoustic Emission Latency Using Linear Prediction Coding Spectrum)

  • 안정일;최진영;이건일
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권3호
    • /
    • pp.185-190
    • /
    • 1991
  • An automatized latency calculation method of an e-OAE(evoked otacoustic emission) is proposed. The e-OAE signal measured from a normal adult is averaged 1000 times to remove noises. This averaged signal is converted to digital signal and that is processed by IBM-AT computer for latency calculation. we separate the stimulated and the emitted signal on the time domain by a modified LPC (linear prediction coding) spectrum, and the latency is calculated by cross-correlation method. By proposed latency calculation method the latency is 7.9[ms] for normal adult. The performance of the proposed method is also compared with that of the auto-correlation and cross performance of the proposed method is also compared with that of the auto-correlation and cross-correlation method. The result show that the proposed method has same precision with the conventional methods and can automatically calculate latency without subjective observation.

  • PDF

Pulsed CW 신호를 사용하는 수중 음원의 위치 추정을 위한 시간지연차 추정법 (Position Estimation of Underwater Acoustic Source Using Pulsed CW Signal)

  • 최영근;손권;도경철;김기만
    • 한국음향학회지
    • /
    • 제23권7호
    • /
    • pp.514-520
    • /
    • 2004
  • 수중에서 음원의 위치 추정을 위해 적용되어지는 기법으로써 시간지연차 (TDOA : Time Difference Of Arrival) 추정, 빔 형성 기법, 고 분해능 기법 등이 있다. 본 논문에서는 상대적으로 적은 수의 센서를 사용하여 주파수 영역에서 시간 지연차 추정에 사용되는 MCPSP (Modified Cross Power Spectrum Phase) 함수를 이용하였다. 그러나 MCPSP 함수에 기반한 방법은 CW (Continuous Wate) 신호를 대상으로 할 경우 추정 성능이 크게 떨어진다. 이에 본 논문에서는 Pulsed CW신호를 사용하는 수중 음원의 위치를 추정하기 위해 단 구간 (short-time) 에너지 검출을 이용하여 핑(ping)의 경계 영역을 포함하는 세그먼트를 구성하고 이로부터 MCPSP 함수를 구하는 방법을 제안하였다. 제안된 방법의 성능에 대한 이론적인 접근과 함께 다양한 환경 하에서 분석이 이루어졌다.