• Title/Summary/Keyword: Cross flow type

Search Result 302, Processing Time 0.026 seconds

NUMERICAL STUDY FOR THE FULL-SCALE ANALYSIS OF PLATE-TYPE HEAT EXCHANGER USING ONE-DIMENSIONAL FLOW NETWORK MODEL and ε-NTU METHOD (판형 열교환기 Full-scale 해석을 위한 1차원 유동 네트워크 모델 및 ε-NTU 모델의 수치적 연구)

  • Kim, Minsung;Min, June Kee;Ha, Man Yeong
    • Journal of computational fluids engineering
    • /
    • v.19 no.1
    • /
    • pp.47-56
    • /
    • 2014
  • Since a typical plate heat exchanger is made up of a huge number of unitary cells, it may be impossible to predict the aero-thermal performance of the full scale heat exchanger through three-dimensional numerical simulation due to the enormous amount of computing resources and time required. In the present study, a simple flow-network model using the friction factor correlation and a thermal-network model based on the effectiveness-number of transfer units (${\varepsilon}$-NTU) method has been developed. The complicated flow pattern inside the cross-corrugated heat exchanger has been modeled into flow and thermal networks. Using this model, the heat transfer between neighboring streams can be considered, and the pressure drop and the heat transfer rate of full-scale heat exchanger matrix are calculated. In the calculation, the aero-thermal performance of each unitary cell of the heat exchanger matrix was evaluated using correlations of the Fanning friction factor f and the Nusselt number Nu, which were calculated by unitary-cell CFD model.

Analysis of Flow Duration Based on SWAT-K Simulation for Construction of Natural Riparian (자연하안조성을 위한 SWAT-K 모의치 기반 유황 분석)

  • Kim, Nam-Won;Lee, Jeong-Woo;Chung, Il-Moon;Kim, Ji-Tae
    • Journal of Environmental Science International
    • /
    • v.20 no.11
    • /
    • pp.1457-1464
    • /
    • 2011
  • In this study, the method of estimating hydrologic information (water depth, submerged period etc.) on the proper selection of construction point and scale as well as vegetation type suggested for the design of natural riparian rehabilitation structure. Long-term comprehensive watershed model SWAT-K(Korea) was applied to this purpose. Flow duration analysis was conducted to analyze the hydrologic characteristics of Pyungchang watershed at which the 'bangtul' construction method was tested. For this purpose 20 years (1989-2008) rainfall runoff analysis was carried out. Based on the simulated daily streamflow data, flow duration curve was made to analyze the flow characteristics, and the water depth hydrograph was made to analyze the water depth distribution at the cross section. Finally, the information for the selection of proper vegetation according to the submerged period is suggested.

Development of a Plate-Fin Type Gas Turbine Recuperator

  • Kwak Jae-Su;Yang In-Young
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.7
    • /
    • pp.1068-1076
    • /
    • 2006
  • A plate-fin type recuperator for a gas turbine/fuel cell hybrid power generation system was designed, manufactured, and tested. Performance analysis shows that the performance of the system is directly affected by the performance of the recuperator. Therefore, the recuperator should be designed and manufactured carefully, and its performance should be tested and verified before it is integrated into the system. In this paper, the developing procedure including designing, manufacturing, and testing of a cross flow plate-fin type recuperator was presented. Performance test results showed that the design requirements of the recuperator were almost satisfied. Based on the test results, improved design to reduce the size of the recuperator was suggested.

PLC Optical Sensor for Contamination Monitoring on the Flow-Cell in the Water Quality Measurement System (수질 측정용 플로우 셀의 오염 모니터링을 위한 평면광도파로 센서)

  • Han, Seung Heon;Kim, Tae Un;Jung, Haeng Yun;Ki, Hyun Chul;Kim, Doo Gun;Kim, Seon Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.6
    • /
    • pp.472-476
    • /
    • 2019
  • We have proposed a novel planar lightwave circuit (PLC) optical sensor to monitor the contamination in a flow-cell where water is continuously supplied through a water quality measurement system. We designed a PLC chip with a V-shape waveguide and the simulated its function as a sensor for monitoring contamination in a flow-cell using a numerical the FDTD (finite-difference time-domain) analysis. A novel cross type of waveguide was introduced to make the PLC chip of the V-shaped waveguide. The fabricated PLC was cut into the cross waveguide. A change in the optical propagation loss of the PLC sensor was observed after immersing the PLC sensor into city water. It was determined that the propagation loss of the PLC sensor was 3 dB at a wavelength of $1.55{\mu}m$ in the city water for 15 days.

Investigation of FIV Characteristics on a Coaxial Double-tube Structure (동심축 이중관 구조에서 유동기인진동 특성 고찰)

  • Song, Kee-Nam;Kim, Yong-Wan;Park, Sang-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.10
    • /
    • pp.1108-1118
    • /
    • 2009
  • A Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source of the order of $950^{\circ}C$ for nuclear hydrogen generation, which can produce hydrogen from water or natural gas. A primary hot gas duct (HGD) as a coaxial double-tube type cross vessel is a key component connecting a reactor pressure vessel and an intermediate heat exchanger in the VHTR. In this study, a structural sizing methodology for the primary HGD of the VHTR is suggested in order to modulate a flow-induced vibration (FIV). And as an example, a structural sizing of the horizontal HGD with a coaxial double-tube structure was carried out using the suggested method. These activities include a decision of the geometric dimensions, a selection of the material, and an evaluation of the strength of the coaxial double-tube type cross vessel components. Also in order to compare the FIV characteristics of the proposed design cases, a fluid-structure interaction (FSI) analysis was carried out using the ADINA code.

Ecogeological Description of Sanyang Gotjawal, Jeju Island, Korea

  • Yi, Yun-Jae;Kim, Dae-Shin;Ko, Suk-Hyung;Lee, Keun Chul;Lee, Jung-Sook;Kim, Jong-Shik
    • Korean Journal of Environmental Agriculture
    • /
    • v.41 no.3
    • /
    • pp.217-221
    • /
    • 2022
  • BACKGROUND: Gotjawal forest on Jeju Island is characterized by uneven topography that developed as a result of freezing-thawing weathering process and irregular substrates caused by numerous lava-flow collapses. Sanyang Gotjawal, located in southwest of Jeju Island, is a well-developed forest with a long history. In addition to photographs, there is a need for a good way to describe the unique features of Gotjawal, including its geology and vegetation. METHODS AND RESULTS: We illustrated the area's natural features using Clip Studio Paint 1.12.0. To reveal its complexity, we separated the vegetation and geological features in the illustrations. CONCLUSION(S): We drew a cross-section of Gotjawal's unique layers, including lava flows. In addition to an eco-geological approach, we described the dominant vegetation and geological characteristics of the three forest layers (trees, shrubs, and herbs) in Gotjawal.

Environmental risk assessment of genetically modified Herbicide-Tolerant zoysiagrass (Event: Jeju Green21) (제초제저항성 들잔디(Zoysia japonica Steud.) 이벤트 Jeju Green21의 환경위해성평가)

  • Bae, Tae-Woong;Kang, Hong-Gyu;Song, In-Ja;Sun, Hyeon-Jin;Ko, Suk-Min;Song, Pill-Soon;Lee, Hyo-Yeon
    • Journal of Plant Biotechnology
    • /
    • v.38 no.2
    • /
    • pp.105-116
    • /
    • 2011
  • Transgenic zoysiagrass (Zoysia japonica Steud.) expressing the bar gene inserted in the plant genome has been generated previously through Agrobacterium tumefaciens-mediated transformation. The GM zoysiagrass (event: JG21) permits efficient management of weed control of widely cultivated zoysiagrass fields, reducing the frequency and cost of using various herbicides for weed control. Now we have carried out the environmental risk assessment of JG21 prior to applying to the governmental regulatory agency for the commercial release of the GM turf grass outside of test plots. The morphological phenotypes, molecular analysis, weediness and gene flow from each test plot of JG21 and wild-type zoysiagrasses have been evaluated by selectively analyzing environmental effects. There were no marked differences in morphological phenotypes between JG21 and wild-type grasses. The JG21 retained its stable integration in the host plant in T1 generation, exhibiting a 3:1 segregation ratio according to the Mendelian genetics. We confirmed the copy number (1) of JG21 by using Southern blot analysis, as the transgenic plants were tolerant to ammonium glufosinate throughout the culture period. From cross-fertilization and gene flow studies, we found a 9% cross-pollination rate at the center of JG21 field and 0% at distances over 3 m from the field. The JG21 and wild-type zoysiagrass plants are not considered "weed" because zoysiagrasses generally are not dominant and do not spread into weedy areas easily. We assessed the horizontal gene transfer (HGT) of the transgene DNA to soil microorganisms from JG21 and wild-type plants. The bar gene was not detected from the total genomic DNA extracted from each rhizosphere soil of GM and non-GM Zoysia grass fields. Through the monitoring of JG21 transgene's unintentional release into the environment, we found no evidence for either pollen mediated gene flow of zoysiagrass or seed dispersal from the test field within a 3 km radius of the natural habitat.

Development of a Rice Circulating Concurrent-flow Dryer (I) - Performance Test of Pilot Scale Dryer - (순환식 병류형 곡물건조기 개발 (I) -시작기의 성능시험 -)

  • Han J.W.;Keum D.H.;Han J.G.;Kim H.;Hong S.J.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.4 s.117
    • /
    • pp.349-354
    • /
    • 2006
  • This study was performed to evaluate the performances for a concurrent flow rice dryer of pilot scale with devices for circulating rice. The pilot scale dryer with the capacity of 700 kg was developed to obtain design informations for the development of actual scale dryer of holding capacity of 10 tons. Three drying tests were conducted at two temperature levels of $100^{\circ}C\;and\;120^{\circ}C$, and two air flow rates levels of $28.5cmm/m^2\;and\;57.1cmm/m^2$. Drying conditions for Test-1, Test-2 and Test-3 were $100^{\circ}C\;-28.5cmm/m^2,\;120^{\circ}C-28.5cmm/m^2\;and\;120^{\circ}-57.1cmm/m^2}$ respectively. Drying rates were 0.73%(w.b./h) for Test-1, 0.90%(w.b./h) for Test-2 and 1.46%(w.b./h) for Test-3. The crack ratios of brown rice after drying ranged from 2.4% to 8.4%, and increased with the increase of drying rate and airflow rate. The energy consumptions were from 6,225 kJ/kg to 6,993 kJ/kg which was higher than that of conventional cross-flow rice circulating type dryer used in Korea. This results were due to the lower ambient air temperatures of $4.5^{\circ}C\;to\;13.4^{\circ}C$ during drying tests.

Development of a Direct-Connected Supersonic Combustor Test Facility (직결형 초음속 연소기 시험 설비 개발)

  • Yang, Inyoung;Lee, Kyung-jae;Lee, Yang-ji;Kim, Hyung-Mo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.290-293
    • /
    • 2017
  • A direct-connected, continuous type combustion test facility was developed to test a supersonic combustor model used in scramjet engines. The facility requirements were determined by assuming the flight speed of Mach 5, yielding the combustor inlet flow speed of Mach 2. Also the cross-section of the supersonic combustor under test was assumed as $32mm{\times}70mm$. As a result, the facility was designed to have the flow total pressure of 548 kPaA, total temperature of 1,320 K, and flow rate of 0.776 kg/s. The facility consists of a turbo type air compressor, electric air heater, vitiation air heater and a two dimensional facility nozzle to accelerate the flow to Mach 2. Also, an oxygen supply system was added to compensate the vitiation. The exhaust de-pressurization system is not added. Designed pressure, temperature, and flow rate were verified through the test operation of the facility.

  • PDF

Analytical Performance Evaluation of Pneumatic Nebulizers and Comparison of Their Characteristics (가압분무기의 성능 평가와 특성 비교)

  • Park, Chang Joon;Han, Myung Sub;Song, Sun Jin;Lee, Dong Soo
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.120-126
    • /
    • 2002
  • The analytical performance of four commercially-available pneumatic nebulizers(Meinhard, Cross-flow, Babington, ESI PFA) was evaluated using inductively coupled plasma-atomic emission spectrometry (ICP-AES) and ICP-mass spectrometry (ICP-MS) instruments. The performance of an inert concentric nebulizer and a modified conespray nebulizer, made in Korea Research Institute of Standards and Science (KRISS), is compared with that of the four commercial nebulizers. Variation of sample introduction efficiency was investigated as carrier argon pressure and sample uptake rate were changed. Variation of sensitivity, signal stability, blank intensity and oxide/hydride ratios were also studied when the nebulizers were connected to the ICP-MS and ICP-AES instruments. It was found that good analytical result such as high sensitivity, low blank, stable signal and so on can be obtained with judicious selection of the nebulizer depending on the type of sample, sample amount, type of analytical instrument and analyte.