• 제목/요약/키워드: Cross flow heat exchanger

검색결과 76건 처리시간 0.017초

동심축 이중관 구조에서 유동기인진동 특성 고찰 (Investigation of FIV Characteristics on a Coaxial Double-tube Structure)

  • 송기남;김용완;박상철
    • 대한기계학회논문집A
    • /
    • 제33권10호
    • /
    • pp.1108-1118
    • /
    • 2009
  • A Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source of the order of $950^{\circ}C$ for nuclear hydrogen generation, which can produce hydrogen from water or natural gas. A primary hot gas duct (HGD) as a coaxial double-tube type cross vessel is a key component connecting a reactor pressure vessel and an intermediate heat exchanger in the VHTR. In this study, a structural sizing methodology for the primary HGD of the VHTR is suggested in order to modulate a flow-induced vibration (FIV). And as an example, a structural sizing of the horizontal HGD with a coaxial double-tube structure was carried out using the suggested method. These activities include a decision of the geometric dimensions, a selection of the material, and an evaluation of the strength of the coaxial double-tube type cross vessel components. Also in order to compare the FIV characteristics of the proposed design cases, a fluid-structure interaction (FSI) analysis was carried out using the ADINA code.

국산 막형 산화기 (OXYREX)의 체외순환 임상 성적 - 개심수술 40례 적용 - (Clinical Application of OXYREX Hollow Fiber Membrane Oxygenator)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • 제23권6호
    • /
    • pp.1049-1056
    • /
    • 1990
  • The OXYREX hollow fiber membrane oxygenator developed by joint work of KIST and Green Cross Medical company has been evaluated by experimental investigation and clinical application, In this oxygenator gas exchanges occur through small pores of 0.1pm size which are distributed on 70% of surface of polypropylene hollow fiber. The Oxyrex membrane oxygenator consists of 36 thousand hollow fibers and it has 3.3m2 of gas exchange surface. The Oxyrex membrane oxygenator has unique blood flow path: blood enters the oxygenator passes between the hollow fibers and exits through outlet ports, that provides low transmembrane pressure drop. In the animal experiment and in vitro investigations of Oxyrex oxygenator, it showed low transmembrane pressure difference, effective heat exchanger performance, stable gas transfer function and less blood trauma. The Oxyrex oxygenator been used from March, 1990, to October, 1990, in 40 patients undergoing open heart operations. In the clinical applications of Oxyrex, adequate oxygenation[PaO2, 283$\pm$70mmHg] and carbon dioxide removal[PaCO2, 27\ulcorner6mmHg]were maintained under the condition of FiO2: below 0.6, Hct; 25%, perfusion flow; 2.4 L/min, gas flow: 2.1 L/min. During maximum 365 minutes of cardiopulmonary bypass[CPB] time period, the Oxyrex oxygenator maintained stable condition of PaO2, PaCO2 respectively and it also kept low plasma hemoglobin level. The complement proteins C3 and CH50 were not significantly changed pre to post CPB. There were no complications related to the oxygenator during and after the CPB.

  • PDF

Development of a Plate-Fin Type Gas Turbine Recuperator

  • Kwak Jae-Su;Yang In-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제20권7호
    • /
    • pp.1068-1076
    • /
    • 2006
  • A plate-fin type recuperator for a gas turbine/fuel cell hybrid power generation system was designed, manufactured, and tested. Performance analysis shows that the performance of the system is directly affected by the performance of the recuperator. Therefore, the recuperator should be designed and manufactured carefully, and its performance should be tested and verified before it is integrated into the system. In this paper, the developing procedure including designing, manufacturing, and testing of a cross flow plate-fin type recuperator was presented. Performance test results showed that the design requirements of the recuperator were almost satisfied. Based on the test results, improved design to reduce the size of the recuperator was suggested.

전산유체역학을 이용한 직교류 미세관 관군의 전열 성능 해석 (Analysis of Heat Transfer Performance for Mini-Channel Tube Bundles in Cross flow using CFD)

  • 남기원;민준기;정지환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.491-499
    • /
    • 2010
  • 관군은 열전달기기에서 광범위하게 사용되고 있어서 전열성능 및 압력강하 특성은 오래전부터 다양한 연구가 진행되어왔다. 기존의 관군에 관한 실험 및 해석은 대부분 25~51mm 직경의 전열관을 이용하여 Reynolds 수 $8.000{\leq}Re{\leq}30.000$ 범위에서 수행되었으나 최근에는 직경 1mm 안팎의 미세관으로 관군을 만들어 열교환기의 밀집도를 높이려는 데 관심이 많다. 본 논문에서는 이전에 다루지 않았던 관 외경 1.5mm의 관군의 전열성능을 $3.000{\leq}Re{\leq}7.000$ 범위에서 전산유체역학을 이용하여 평가하고 기존의 연구 결과들과 비교하였다. 그 결과 튜브직경이 1.5mm인 관군의 열전달계수와 압력손실계수는 $3.000{\leq}Re{\leq}7.000$ 범위에서도 기존의 Zukauskas 상관식과 최대 4.7% 차이 이내로 일치하였다. 또한 튜브의 횡방향 간격을 줄여서 각 열의 전열성능을 높일 수 있음을 확인하였다.

유한요소법을 이용한 헤어핀 형 열 교환기의 튜브 확관에 대한 연구 (Study of Tube Expansion to Produce Hair-Pin Type Heat Exchanger Tubes using the Finite Element Method)

  • 홍석무;현홍철;황지훈
    • 소성∙가공
    • /
    • 제23권3호
    • /
    • pp.164-170
    • /
    • 2014
  • To predict the deformation and fracture during tube expansion using the finite element (FE) method, a material model is considered that incorporates the damage evolution due to the deformation. In the current study, a Rice-Tracey model was used as the damage model with inclusion of the hydrostatic stress term. Since OFHC Cu is not significantly affected by strain rate, a Hollomon flow stress model was used. The material parameters in each model were obtained by using an optimization method. The objective function was defined as the difference between the experimental measurements and FE simulation results. The parameters were determined by minimizing the objective function. To verify the validity of the FE modeling, cross-verification was conducted through a tube expansion test. The simulation results show reasonable agreement with the experiments. The design for a minimum diameter of expansion tube using the FE modeling was verified by a simplified tube expansion test and simulation results.

수평 실린더에서의 서리 생성에 대한 환경 변수들의 영향 (The Effect of Environmental Parameters on Frost Formation on a Horizontal Cylinder)

  • 이윤빈;류인상;노승탁
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.253-260
    • /
    • 2002
  • It is known that frost formation on surfaces of the heat exchanger seriously affects the performance of the refrigeration system. Accordingly, defrosting should follow, and effective defrosting is possible only when both analytic tools and comprehensive experimental data on frost formation are assailable. An experimental investigation was undertaken to characterize the effect of environmental parameters on frost formation on a horizontal cylinder in cross uniform flow. Several experiments were carried out with various environmental parameters such as inlet air temperature, inlet air humidity, air velocity and cooling surface temperature. Frost thickness, mass, surface temperature and cylinder inner and outer temperature were measured at front and rear positions of the cylinder. Thickness, mass, density, and effective thermal conductivity of the frost layer were obtained from measured data and effects of environmental parameters on the frost formation were analyzed. Data from experiments were correlated using dimensionless variables.